Analysis on the Effects of Sunshine Environment by Overpass Structure in Urban Areas (도시부 고가구조물에 의한 일조환경 영향분석)

  • Kum, Ki-Jung;Kim, Jong-Bo;Choi, Yong-Gil;Kim, Young-Jun
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.49-58
    • /
    • 2009
  • Current sunshine regulations of our country, focused on common houses and general construction, are failing to reflect adequately the characteristics of roads and elevated structures. Besides, researches are chiefly being conducted on a pitch between common houses and its diverse effects, neglecting clearance between a road or elevated structure and a residential area, environmental elements brought on by structures, such as sunshine difficulty, and their resultant factors Therefore, this study, focused on the sunshine environment of elevated structures adjacent to a residential district, as part of all roads and elevated structures, looked over currently used clearance adequacy level and analyzed the characteristics of structures in relation to an angle of direction. Then, clearance ratio by heights was calculated through a pitch by characteristics of a structure. With a view to minimize the sunshine difficulty that might occur in the future construction, it aims to propose the basic data needed for calculating the minimum clearance, while emphasizing the necessity for institutional alignment on structures.

  • PDF

Sensitivity Analysis for Active Control over Input Parameters in Tsunami Models (지진해일 모형 입력인자의 능동적 제어를 위한 민감도 분석)

  • Son, Sangyoung;Jung, Tae-Hwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.469-469
    • /
    • 2016
  • 본 연구에서는 지진해일 모의결과를 바탕으로 하여 지진해일모형 결과에 민감하게 작용할 수 있는 다양한 입력조건을 분석하였다. 우선 2004년 인도양 지진해일 모의를 위하여 다중격자체계를 갖추고 있는 COMCOT모형과 수심적분된 Boussinesq모형의 결합모형을 사용하였으며, 근해역에 지진해일 충격 및 피해산정 결과에 유효한 영향을 주는 입력인자를 파악하기 위하여 4가지의 시나리오를 설정하였다. 각 시나리오에서는 3개의 서로 다른 독립인자가 포함되었으며 이들은 배타적으로 결정되어 최소한의 시나리오로 다양한 분석이 가능하도록 하였다. 즉, 시나리오 1에서는 지진해일의 초기수면상태를 산정하기 위한 간략화된 단층모형을 적용하였고, 이 때 바닥마찰에 대한 고려는 배제되었다. 시나리오 2에서는 시나리오 1과 모든 조건은 동일하게 하였으나 유한단층 모형을 통해 초기수면상태를 산정하도록 하였다. 이처럼 유사하게 시나리오 3에서는 복잡한 지형 특성을 나타내는 몰디브 지역의 보다 정확한 해석을 위하여 몰디브 지역의 상세격자망을 추가적으로 다중격자체계에 포함시켰다. 마지막으로 바닥마찰항에 대한 민감도를 분석하기 위하여 시나리오 4에서는 바닥마찰항에 대한 고려를 포함시켰다. 또한, 4가지 시나리오 외에 결합모형의 성능을 평가하기 위하여, COMCOT모형만을 사용하는 시나리오를 추가적으로 설정하였다. 즉, 시나리오 1과 모든 조건은 동일하되 COMCOT모형만을 사용하도록 하였다. 설정된 조건에 따른 수치모의 결과, 지진해일 내습에 따른 해수위 변화는 각 시나리오별로 큰 차이를 보이지 않았으나, Boussinesq모형에 의한 지진해일의 동수역학적 거동은 COMCOT모형을 사용한 결과와 유의한 차이를 보였으며, 특히 파랑에 기인한 난류적 거동은 극명한 대조를 이루었다. 따라서, 본 연구결과를 통해 향후 파랑에 기인한 난류적 거동의 정확모의를 위해 수치해석에 따른 확산오차 및 바닥마찰항에 대한 면밀한 연구가 필요함을 시사하였다.

  • PDF

Inundation Pattern Analysis by Applying Flood Routing Model with Random Forest Regression (하도홍수추적 모형과 랜덤포레스트 회귀를 이용한 침수양상 분석)

  • Kim, Hyun Il;Kim, Byung Hyun;Han, Kun Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.398-398
    • /
    • 2020
  • 대도시 상류부에 위치한 댐의 과도한 방류 또는 급작스러운 붕괴는 대규모의 인명 또는 재산피해를 야기할 수 있으며, 다양한 댐 유입량 조건에 따른 침수양상을 파악하는 것은 수재해 대응능력 향상에 필수적이다. 그러나 다양한 과다한 댐 방류 또는 붕괴유량에 따른 침수 범위는 도시의 내수침수와 달리 매우 넓은 지형조건을 고려하며 침수 범위가 광범위하게 나타날 수 있다. 이는 다양한 댐 유입량 조건에 따른 침수 지도를 생성 및 파악하는데 어려움을 가중시키며, 특히 댐 운영에 따른 침수양상을 실시간으로 파악하는데 어려움을 가중시킨다. 본 연구에서는 저빈도부터 PMF(Probable Maximum Flood) 조건까지의 다양한 댐 유입량자료를 바탕으로, 1차원 하천홍수해석을 실시하였다. 연구 대상으로 팔당댐에 대한 댐 해석을 실시하였으며, 팔당댐 하류에 위치한 서울시에 대한 영향을 분석하였다. 1차원 해석 결과로 산정되는 각하도 단면 별 홍수위자료와 GIS을 연계하여 다양한 발생빈도를 나타내는 유입량에 대한 침수지도를 생성하였으며, 기존에 제시된 발생빈도에 따른 침수지도 외에 임의 빈도의 침수지도를 실시간으로 생성할 수 있는 랜덤포레스트 회귀 모형을 구축하였다. 위의 과정들을 통해 다양한 유입량 조건에 따른 연구대상 지역에서의 침수예상도를 분석할 수 있었으며, 서울시 전반적으로 나타날 수 있는 침수심의 공간적 분포를 파악할 수 있었다. 주어진 침수 지도를 이용하여 서울시에 대한 인구 및 건축물의 경제적 가치 자료를 이용하여 추가적인 홍수 위험도 분석이 가능할 것으로 보이며, 임의 빈도에 대하여 실시간으로 침수를 예측할 수 있는 랜덤포레스트와 연계할 수 있다. 제시된 방법론은 댐의 과다한 방류량과 붕괴 현상을 재현하며, 도시의 수재해 대응능력 향상을 위한 기초자료를 제공할 수 있을 것으로 보인다.

  • PDF

Joint Stiffness Evaluation in Jointed Plain Concrete Pavement (줄눈 콘크리트 포장의 줄눈강성 산정 연구)

  • Chon, Beom Jun;Lee, Seung Woo;Kwon, Soon-Min;Kim, Seong-Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1D
    • /
    • pp.49-54
    • /
    • 2009
  • The excellent load transfer at transverse joints ensures the high performance of jointed plane concrete pavements(JPCP). Load transfer efficiency(LTE) is affected by dowel-bars, aggregate interlock and types of underlying layers, and these factors have to be modelled adequately for a reasonable analysis of JPCP. Generally, the joint stiffness has been represented by a spring model for the shear transfer by aggregate interlock or dowels. However dowel-bars, aggregate interlock and types of underlying layers have not been considered together in the design of joints. In this study, the joint stiffness that considered those factors was presented by comparing LTE obtained using FWD(Falling Weight Deflectometer) with theoretical results obtained using the finite element analysis. In addition, the effects of temperature and concrete age, on the joint stiffness were investigated.

A Study on Sediment Transport Analysis and Long-term volatility of River Bed Analysis Using Hydraulic Geometry (수리기하 이론을 이용한 유사거동 분석 및 하상의 장기변동성 검토)

  • Kim, Hyeonseung;Yu, Hyeri;Kim, Dae-Hong;Paik, Kyungrock
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.204-204
    • /
    • 2022
  • 하천 내에서 하상변동은 치수나 생태계에 직간접적인 영향을 끼치는 것으로 알려져 있다. 하상변동의 예측을 위한 여러 가지 모델들이 존재하지만 하상변동의 양상을 직관적으로 파악하기에는 어려움이 있다. 최근 수행된 연구 결과에 따르면 하천의 수리 기하학적 형상이 부유사 농도와 유량과의 관계와 관련이 있는 것으로 밝혀졌다(Kim et al., 2018). 본 연구에서는 수리기하(Hydraulic Geometry) 이론을 이용하여 하천의 형상에 따른 유사거동과의 상관관계를 통해서 하상의 장기적 변동성을 직관적으로 유추할 수 있는 기법을 제시하고자 한다. 이를 위해 본 연구에서는 수리기하 이론에서의 수심과 폭을 나타내는 인자들을 이용하여 하천의 형상을 넓고 얕은 하천, 좁고 깊은 하천, 중간 정도의 하천으로 분류하였으며 흐름조건을 정상류와 부정류조건으로 분류하였다. 또한 하상경사와 하상재료의 입경 분포를 고려하여 자연하천에서 존재할 수 있는 다양한 하천형상에 대해 수치모의를 진행하였다. 기존의 Manning 공식에 수심, 유속만 고려한 것이 아닌 조도계수까지 고려하여 수리기하 이론을 접목시킴으로서 유속과 수심의 수리기하적 인자로 계산된 하상전단력의 수리기하적 인자가 수치모의를 통해 구한 값과 거의 일치하는 것을 확인하였다. 하천의 형상이 넓고 얕을수록 수리기하 관계로 표현한 하상전단력 인자가 작은 값을 나타냈으며 수리기하 관계로 표현한 부유사농도인자와 하상전단력 인자가 비슷한 양상을 띄는 것이 확인되었다. 이를 통해 하천이 기하학적 형상으로부터 하상의 변동성을 유추할 수 있었다. 실제 하천에 대한 검증은 금강 수계에 있는 미호천과 갑천을 대상으로 수행하였다. 수리기하적으로 표현하였을때 갑천은 미호천에 비해 넓고 얕은 하천에 속하는데 현재까지 관측된 자료를 이용하여 두 하천의 하상변동량을 비교해본 결과 갑천이 미호천에 비해 변동량이 적었으며 이는 위의 내용과 일치한 결과를 나타냈다.

  • PDF

Effects of Physical Factors on Urban Surfaces on Air Quality - Chang Chun, China as an Example - (도시표면의 물리적 요소가 대기질에 미치는 영향 - 중국 창춘을 사례로 -)

  • Jin, Quanping;Kim, Tae Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.5
    • /
    • pp.1-11
    • /
    • 2021
  • The purpose of this study is to find out the main factors affecting air quality in urban physical space factors, and provide clues for environmental improvement. Nine monitoring stations in China's industrial city, Changchun, collected AQI concentration data from January 1, 2018 to December 31, 2019. This paper analyzes the types and distribution characteristics of urban physical facilities within a radius of 300m with the detection station as the center. The monitoring station is divided into three groups, and the difference in floating dust concentration among the three groups in different seasons is analyzed. The results show that AQI concentration is the highest in spring and winter, followed by summer, and the lowest in autumn. The place with the highest concentrations of AQI in spring are F (93.00), D (91.10), I (89.20), in summer are D (69.05), A (67.89), B (84.44), in autumn are I (62.80), G (60.84), D (53.27), D (53.27), in winter are I (95.82), H (95.60), f (94.04). Through SPSS analysis, it shows that the air index in a space with a diameter of 600 meters is related to forest land, grassland, bare land, water space, tree height, building area (average value), and building volume (average value). According to the statistical analysis results of spring and winter with the most serious pollution, forest land area (43,637m2, 15.44%) and water surface area (18,736m2, 6.63%) accounted for the majority, and group 1 (A, B, C) with the least average building area (448m2, 0.17%) and average building volume (10,201m2) had the lowest pollution concentration. On the contrary, group 2 (D, E, F) had the highest AQI concentration, with less or no woodland (1,917m2, 0.68%) and water surface area (0m2, 0%), and the highest average building area (1,056m2, 0.37%) and average building volume (17,470m3). It is confirmed that the characteristics of the area with the highest AQI concentration are that the more the site ratio of tree height above 12m, the smaller the site ratio of bare land, and the lower the pollution degree. On the contrary, the larger the area of bare land, the higher the pollution degree. By analyzing the characteristics of nine monitoring stations in Changchun, it can be seen that the air quality brought by the physical characteristics of urban space is closely related to the above factors.

A study on the application of the agricultural reservoir water level recognition model using CCTV image data (농업용 저수지 CCTV 영상자료 기반 수위 인식 모델 적용성 검토)

  • Kwon, Soon Ho;Ha, Changyong;Lee, Seungyub
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.4
    • /
    • pp.245-259
    • /
    • 2023
  • The agricultural reservoir is a critical water supply system in South Korea, providing approximately 60% of the agricultural water demand. However, the reservoir faces several issues that jeopardize its efficient operation and management. To address this issues, we propose a novel deep-learning-based water level recognition model that uses CCTV image data to accurately estimate water levels in agricultural reservoirs. The model consists of three main parts: (1) dataset construction, (2) image segmentation using the U-Net algorithm, and (3) CCTV-based water level recognition using either CNN or ResNet. The model has been applied to two reservoirs G-reservoir and M-reservoir with observed CCTV image and water level time series data. The results show that the performance of the image segmentation model is superior, while the performance of the water level recognition model varies from 50 to 80% depending on water level classification criteria (i.e., classification guideline) and complexity of image data (i.e., variability of the image pixels). The performance of the model can be improved if more numbers of data can be collected.

Free Vibration Analysis of Thick Plate Subjected to In-plane Force on Inhomogeneous Pasternak Foundation (비균질 Pasternak지반 위에 놓인 면내력을 받는 후판의 진동해석)

  • Lee, Yong Soo;Kim, Il Jung;Oh, Soog Kyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.291-298
    • /
    • 2003
  • Recently, as the size of buildings structure becomes large increases, their mat area of building structure is supported or by an inhomogeneous foundation. This paper presents a vibration analysis on thick plates subjected to in-plane force is presented in this paper. The rectangular plate is isotropic, homogeneous, and composed of a linearly elastic material. A vibration analysis of the rectangular thick plate iwas done by useing ofarectangular finite element with 8 nodes and 9 nodes. In this study, the foundation was idealized as a Pasternak foundation model. A Pasternak foundation haves a shear layer on Winkler's model, which idealizes the foundation as a vertical spring. In order tTo analysze the vibration of a plate supported on by an inhomogeneous Pasternak foundation, the value of the Winkler foundation parameter of the central and border zones of the plate awere chosen as WFP1 and WFP2. (fFigure 4.). The Winkler foundation parameter of WFP1 and WFP2 is varied from 0 to 10, $10^2$, and $10^3$ and the shear foundation parameters is were 0, 5, and 10. The ratio of the in-plane force to the critical load iwas applied as 0.4 to 0.8

A Study of Effect of the Radiative Heat Flux on the Evacuation of Agents (화재에 의해 발생하는 복사열이 재실자의 피난거동에 미치는 영향에 관한 연구)

  • Bae, Sungryong;Kim, Jung-Yup;Shin, Hyun-Joon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • Recently, the safety assessments with using the various evacuation programs are performed for improving the performance of fire and evacuation safety in the building. Generally, the evacuation programs can simulate the human behavior in fire situation by applying the variation of the movement speed and Fractional Effective Dose (FED) index in the smoke. However, if the simulation is performed without optional setting around the fire, the agents do not avoid the fire and they move through the fire. Therefore in this study, we define the radiative repulsion force which exists between the fire and the agents. Moreover, we modify the Helbing's movement model by adding the radiative repulsion force. As a result of the modified movement model, all agents move around the fire and they do not enter the upper bound area of radiative heat flux, $2.4kW/m^2$. From these results, we verified the reliability of the modified movement model.

A Discussion on Determination of Suitable Size of Rain Tank Connected to Building Roof in Suwon District (건축물 지붕과 연결된 빗물저류조의 적정 규모 결정에 관한 고찰: 수원지역을 중심으로)

  • Noh, Huiseong;Ahn, Taejin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.161-169
    • /
    • 2022
  • In this study to estimate suitable size of rain tank in Suwon district, monthly rainfall, daily rainfall duration curve and daily rainy days have been analyzed. Annual rainwater consumption and daily average amount of storage with respect to size of rain tank have been calculated by applying continuity equations that take account of daily rainfall, daily consumptive use, storage of rain tank, It has been shown that above 50 mm of rainfall in the ordinance related to reclamation water may be inappropriate regulation if annual amount of rainfall captured, efficiency of utilized rainwater, number of days for utilized rain tank, daily average amount of storage and daily consumptive use have been considered. Thus, it has been shown that suitable size of rain tank should be determined considering reasonable daily consumptive use with respect to district, constructed cost of rain tank and benefit of rain tank constructed.