• Title/Summary/Keyword: 건축물 화재

Search Result 688, Processing Time 0.028 seconds

A Study on Analysis and Problems of Deliberation to Change the Present Condition Around Cultural Properties - Focusing on the Cultural Properties of Standard Establishment for Change the Present Condition - (문화재 주변 현상변경허가 신청안 분석 및 문제점에 관한 연구 - 현상변경허용기준 수립 문화재를 중심으로 -)

  • Kim, Dong-Chan;Lim, Jin-Kang
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.1
    • /
    • pp.22-30
    • /
    • 2012
  • The purpose of this study of deliberation results to Change the Present Condition of Gyeonggi-do Designated Cultural Properties established Acceptable Standards of Change the Present and its disposal of the fire, Accordingly to minimize the complaints of neighbors cultural property and Decision of Change the Present Condition to maintain the consistency of that is the purpose of this study and The results of the study are as follows First, 82 of proposals with tangible cultural monuments and 56% and 50% each accounted for the majority. 84% of the individual applicant, the application uses 94% of the construction, application facility houses the highest percentage of 40%. Approved and reconsideration results, while the largest number of monuments, rejected the result was the most frequent types of cultural property. and Building height, the highest was filed. Second, the results of deliberation voted two of the most frequently voted 36.5% to 48.7%, 14.6% is the reconsideration. The main reason for the decision passed Cultural minimal impact surrounding landscape, and the application of the buildings surrounding the site have voted in determining the existence of many affected. The main reason for rejection of the decision and voted to determine the cultural assets, compared to inhibition surrounding area of application architecture is characterized by large-scale. The main reason for reconsideration of the decision after a site survey was the most frequent reconsideration. Third, the primary consideration only if you applied a full half of 82 is 47.5% of cases. Consequences of the two manatgo voted the same, assuming the number of agenda items, the more the decision was rejected, and reconsideration. Fourth, the application area committee areas and cultural phenomenon in the conservation area be applied to each 33.7% and 20.2% was most common. Compared with rejection and reconsideration if the various sections of the application has passed. and When applied to the conservation area there were passed. Cultural committee rejected the decision, if applied to areas were most prevalent, reconsideration of the decision was similar in the two areas. Fifth, the size of the construction of buildings collapsed as a result, you voted in rejection have changed. and Voted to reject the results from the increase in building area when changing a lot of decisions have affected the results.

Micromorphological Characteristics of Buddhist Temple Woods Treated with Eire-retardant (방염 처리 고목재의 미생물 분해의 미시형태적 특징)

  • Wi, Seung Gon;Kim, Ik-Joo;Park, Young Man;Kim, Yoon Soo
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.27-34
    • /
    • 2001
  • Following the recommendations made by the cultural authorities the wooden cultural properties (WCP) had been treated with fire-retardants for fire protection. However, visual inspections of some of the WCPs treated with fire-retardants showed microbial decay. The work was extended to examine the micromorphological characteristics of the WCPs in a Buddhist temple which had been treated with fire-retardant. Microscopic examination showed the presence of typical soft rot cavities along the length of microfibrils in the secondary wall. Bacterial attack was also observed by scanning and transmission electron microscopy. It is interesting that the decay patterns observed in the Buddhist temple were very similar to those observed in the waterlogged woods. Presumably chemicals in the fire-retardants used rendered the wood susceptible to attack by soft-rot and bacterial decay by causing an increase in the moisture content of wood. Further studies are needed to investigate the effect of fire-retardants used currently on the hygroscopicity and the strength of wood materials in the WCPs. Microbial attacks caused degradation of the secondary cell walls and in some cases also of the middle lamella. In addition, the cell walls in the outer parts of wood were also degraded due to weathering, and cell separation occurred from total disintegration of the middle lamella.

  • PDF

Analysis of Ambivalence Differences among Groups for Temporary Firefighting Facilities of Workers at Construction Sites (공사현장 근로자의 임시소방시설에 대한 집단 간 Ambivalence 차이분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.765-778
    • /
    • 2021
  • The purpose of this study is to prevent fire accidents in advance by deriving prior knowledge among groups about temporary fire-fighting facilities of workers at construction sites and devising appropriate improvement measures. The findings are as follows.First, in the case of fire extinguishers, statistical attention was paid to the contractor, supervisor, partner worker and fire extinguisher manager between designations. 87% of fire managers and 70% of facility supervisors said fire extinguisher management managers needed to be designated for each type of construction, which requires designation of fire extinguisher management managers, frequently checking and relocating. Second, in the case of simple fire extinguishing facilities, statistical attention was paid to the application of penalties for unauthorized use of fire extinguishing facilities with construction companies, supervisors, and business partners.Third, in the case of emergency alarm measures, statistical attention was paid to the application of emergency alarm sound to temporary broadcasting facilities with construction works, supervisors, and business partners.Fourth, in the case of induction, statistical attention was paid to the application of connection between construction works, supervisors, and partner workers, such as passage guidance, emergency lighting, etc.It was found that 65% of construction workers and 55% of electrical workers had different applications such as aisle guidance and emergency lighting for each type of business partner. In order to resolve blind spots such as evacuation zone guidance due to the structure of the building, it is necessary to easily distinguish the direction of the entrance door from a long distance by applying it in conjunction with passage guidance lights and emergency lighting.

Development of Truck Shipment Incident Emergency Response System for Transporting Hazardous Materials Using GPS (GPS를 이용한 수송사고 조기경보시스템 개발(1단계 : 국내외 사례조사와 개발방법제시))

  • Oh Se-Chang;Cho Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.1 no.1
    • /
    • pp.79-88
    • /
    • 2002
  • As a part of NERI:;, Truck Shipment Safety Information is divided into Optimal Route Guidance system and Emergency Response system. This study which is for developing of Truck Shipment Incident Emergency Response System intends to prevent or early response damage caused by incidents through realtime monitoring about the position and the state of Hazard material transport truck. For this, we divide it into three scenarios; realtime monitoring, management of incidents, information provision to related organizations and present functional requirements and architecture coming with each scenario. As a result of the first step among total three steps, it would able to not only realtime management of trucks but also guide for auto-enforcement or management about illegal act like dumping scrapped material. It is now under examination about position of detection and technology of communication to application. From now on, it is expect to test in the range of Metropolitan after selecting appropriate technology.

  • PDF

Evaluation of the Smoke Characteristics of Some Plastics in an Enclosed Compartment (밀폐된 구획 내 일부 플라스틱류의 연기 특성 평가)

  • Ji-Sun You;Kyeong-Sin Kang;Jae-Sung Lee;Yeong-Jin Chung
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.421-425
    • /
    • 2023
  • The smoke properties of some plastics were investigated, including polymethyl methacrylate (PMMA), polycarbonate (PC), polyvinyl chloride (PVC), and polyacetal. For smoke density, related values of static smoke characteristics were measured using a smoke density tester according to ISO 5659-2. In addition, combustion with and without flame was measured independently. Under the condition of radiant heat of 50 kW/m2 using the flame method, the measured value of the maximum specific optical density (Dm) of smoke showed the lowest value for PMMA (401.26) and the highest value for PVC (1345.04). In addition, PMMA (262.82) was the lowest and PVC (1385.43) was the highest in the measured Dm of smoke under the condition of radiant heat of 50 kW/m2 in the non-flame method. Smoke generation during combustion of the object is significantly affected by the radiant heat flux, and carbonizable plastics showed a higher amount of smoke than non-carbonizable plastics during combustion. Polymers with aromatic groups in the main polymer chain generated a large amount of smoke because a large amount of char was generated due to thermal decomposition.

Evaluation of Physical Property and Material Characteristics for Stained Glass in the Yakhyeon Catholic Church, Korea (약현성당 스테인드글라스의 재료학적 특성과 물성평가)

  • Cho, Ji Hyun;Lee, Chan Hee;Kang, Myeong Kyu
    • Journal of Conservation Science
    • /
    • v.32 no.3
    • /
    • pp.425-436
    • /
    • 2016
  • The Yakhyeon catholic church (Historic Site No. 252 in Korea) that was constructed in 1892 has been the first western brick structure to ever have existed and one of the most important historical materials in the Korean modern architecture. After a fire had broken out at the catholic church in 1998, the stained glass on the back wall, the slab glass (dalle de verre) introduced by Lee Nam Guy in 1974, was repaired in 1999 because of singe scorch and water leakage. An analysis of the coloration elements showed that yellow, red and green included Zn, K and Cd, respectively. The glass of red contained Se, dark green contained Mn and Cr, and blue contained Pb and S. According to material analysis, the masonry joint was identified dolomite ($CaMg(CO_3)_2$) and calcite ($CaCO_3$), which was observed plate, columnar, rhombic and square of crystalline particles. Meanwhile, ultrasonic velocity in the stained glass recorded low speed in the middle and lower right of the window (an average of 4,130 m/s). And the joint was measured the lowest physical properties of the top left and middle of the window (an average of 2,053 m/s). This study have showed that extensive physical damage was founded to the left and middle rather than the right side. In this respect, more research in needed to conserve the correlation between color and physical properties.

A Study on Analysis of Characteristics Combustion of Floor Covering Materials (바닥내장재의 연소특성 분석에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong;Kim, Hyun-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we analyzed the combustion characteristics of four different floor covering materials(wood, monorium, laminatedpaper, and varnish-laminated paper) with regard to their ignitibility, thermal characteristics and flame retardancy by using an ignition temperature tester, a dual cone calorimeter, a thermogravimetric analyzer and limited oxygen index, for their fire risk assessment. According to the result, monorium had the lowest ignition temperature of $325^{\circ}C$ and the laminated paper and the varnish-laminated paper promptly ignited before 7s. Further, the wood showed the largest total heat release of $100MJ/m^2$, and the varnish-laminated paper showed the highest peak heat release rate. From the thermogravimetric analysis, it was shown that all specimens underwent rapid weight loss at $300{\sim}400^{\circ}C$. The limit oxygen indices of the laminated paper and the varnish-laminated paper were in the range of 20~21%, while it was 34% for wood. This study enabled us to confirm that wood, laminated paper and varnish-laminated paper have a relatively short ignition time and are easy to burn but they all have low heat release. In contrast, wood showed the lowest fire risk among them and had excellent flame retardancy but with high heat release.

Analysis of Building Emergency Evacuation Process with Interactions in Human Behaviors (화재 시 재실자 행동의 상호 작용을 고려한 건물 피난 행태 분석)

  • Choi, Minji;Park, Moonseo;Lee, Hyun-Soo;Hwang, Sungjoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.6
    • /
    • pp.49-60
    • /
    • 2013
  • Evacuation process has been considered as one of the most important elements to be managed in public facilities. Although the importance is highlighted through numerous literatures, disaster evacuation planning, particularly fire accidents, faces a number of human behavior related limitations for a similar application to different types of facilities/occupants. To overcome the obstacles including complexity in human behaviors, a number of simulation techniques with limited consideration on human behaviors are utilized to predict foreseeable problems in evacuation process. Therefore, this research aims to propose system dynamics models incorporating human behaviors considering different types of occupants under disaster evacuation events. Analysis on emergent human behaviors such as group forming and interactions under urgent situation are conducted based on the main stream theories in social science field. The results suggest the influences of human behavior factors including cooperative intention, information sharing, and mobility change to evacuation behavior. The implications are expected to provide safety consideration at planning/designing phase of buildings and help facility safety managers for evacuation planning with more realistic management approaches.

A Comparative Study on the Effect of Fire Retardancy of the Plywood Treated by Ammonium Sulphate and Monoammonium Phosphate (황산암모늄과 제 1 암모늄처리(處理) 합판(合板)의 내화효과에 관(關)한 비교연구(比較硏究))

  • Lee, Phil-Woo;Kim, Cheol-San
    • Journal of the Korean Wood Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.23-30
    • /
    • 1983
  • This experiment was carried out for diminishing the material loss and the damage of human life due to the fire disaster by treating plywood with fire retardant chemical solution. At this study, we observed and measured chemical retention, burning point, maximum flame length, flame exausted time, carbonized area, and weight loss of plywood treated by each solution of ammonium sulphate [$(NH_4)_2SO_4$] and monoammonium phosphate [$NH_4H_2PO_4$]. Obtained results at the study may be summarized as follows: 1. In case of monoammonium phosphate-treated plywood, every tested item of fire retardancy was shown more excellent at the 25% chemical concentration and shown also at 9 hours treatment except maximum flame length compared with ammonium sulphate-treated plywood. 2. However in case of ammonium sulphate-treated plywood, 6 hours treatment of fire retardancy was better than 9 hours treating time. 3. Monoammonium phosphate was generally better than ammonium sulphate in every tested item.

  • PDF

Properties of rin Resistance of High Performance Concrete with Varying Contents of Polypropylene Fiber and Specimen Size (폴리프로필렌 섬유의 혼입률 및 부재크기 변화에 따른 고성능 콘크리트의 내화 특성)

  • 한천구;양성환;이병열;황인성;전선천
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.449-456
    • /
    • 2002
  • Recently, the application of high strength and high performance concrete has been gradually increased as an important construction material for high rise and huge scaled construction. However, high performance concrete has undesirable characteristics of spalling subjected to high temperature due to its dense microstructure content. A spalling by fire brings surface failure and falling off concrete member. It is considered that spalling by fire should be taken into account for the safety of the concrete structure under fire. Therefore, in this paper, tests are carried out using high performance concrete containing polypropylene(PP) fiber in order to improve the fire resistance performance. PP fiber contents and member sizes are varied. According to experimental results, as for the influence of PP fiber contents, all the test specimens without PP fiber show entire failure in W/C of 35%, while they show nearly sound shape except some kinds of surface fracture in W/C of 55%. When PP fiber is contained more than 0.07%, favorable prevention effects of spatting by fire are obtained. As for the effects of test specimens size, it tends to increase the possibilities of spatting by fire as test specimens become larger. And spatting by fire at the edge of test specimens occurs more frequently than at the surface of test specimens. Residual compressive and tensile strength shows 45∼65 % of its original strength at W/C of 35%, and 30∼40% at W/C of 55 %.