• Title/Summary/Keyword: 건축물 화재안전

Search Result 300, Processing Time 0.026 seconds

Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System (급기가압 제연설비의 내부 유동특성에 대한 수치해석)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.52-58
    • /
    • 2017
  • This study investigated the pressure difference distribution and the flow characteristics among room, ancillary room, and stair case by carrying out the numerical simulations on the air flow inside the pressurized air supply smoke control system. Numerical simulations were conducted to analyze pressure and velocity distribution of compartments by pressurized air supply for the air-leakage test facility which was built to measure the effective leakage area. In this study, the leakage of air was considered by locating the narrow slit onto fire door and window of room. Simulated results using this method precisely followed the previous experimental results for the pressure differences between the stair case and ancillary room. Predicted results showed that the local leakage of air rarely affected the overall flow pattern and pressure distribution. Although the average velocity over the door between room and ancillary room satisfied the regulation for fire safety, it was certified the unsafe outflow to ancillary room could be occurred in the local position such as the upper part of the door.

A Toxicity Evaluation for the Toxic Gases of Building Finish Materials (건축물 마감재료 연소가스에 의한 독성평가)

  • Cho, Nam-Wook;Cho, Dong-Ho;Oh, Eun-Ha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.129-140
    • /
    • 2012
  • Smoke toxicity is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice. This test result can be influenced by the health status of mice and test condition. In acute inhalation toxicity test of hazardous gas, no typical clinical findings and histopathologic abnormalities were observed. Tracheitis and bronchitis as well as acute lung inflammation around terminal bronchiole in some mouse of the highest dose group. Through this study, we established the method for inhalation toxicity test of hazardous gas as well as the SOP of inhalation toxicity test. However, in the future studies, the concentration control methods for inhalation technologies on hazardous gas will be needed to improve continuously and also further studies on other gas inhalation toxicity will be needed to conduct.

The Effect of Photoluminescent Exit Path Markings in Evacuation from Buildings (건축물 내에서 축광유도타일이 피난에 미치는 영향)

  • Hur, Man-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.67-72
    • /
    • 2005
  • This study is intended to examine the effect of photoluminescent exit path markings in the event of failure of both the power and back-up power to the lighting and illuminated exit sign. To achieve the purpose, the test house was exhibited in Fire EXPO '05. 520 visitors were examined from May 26-29, 2005. The results of this study are as follows; The evacuation from buildings in dark conditions showed that 70% of men and 72% of women were crawled along the wall. Meanwhile, 88% of men and 83% of women were evacuated with ordinary walking in photoluminescent exit path markings. The photoluminescent exit path markings located on public buildings floors will aid in evacuation from buildings in the event of failure of the power to the lightings and illuminated exit signs.

A Study on the Character and Walking Velocity of Crowd Going up Stairs (계단에서 올라가는 군집보행의 속도에 관한 조사 및 특성에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.72-77
    • /
    • 2011
  • The effort of transferring some parts of urban functions to the underground space is growing trend among modem cities because of the limit of horizontal land use, the rise of land value, the diversification of human desire, etc. Thus, the basement of building and the subway station have deepened. It calls our attention to safety about evacuation from the underground space to the ground. Until now, the study about crowding walk in stairs has been progressed, focusing on the crowding walk that is going down the stairs, and there is no study about crowding walk that is going up the stairs. This study measured walking pace by crowd density that is going up the stairs in the subway station stairs making one-way movement of crowd. The actual survey showed that the mathematical relation 'V=0.638-0.0949p' determines going up walking velocity at a gradient of $23^{\circ}$, and the mathematical relation will be 'V=0.597-0.1067p' at a gradient of $30^{\circ}$, when it is converted, based on the average walking velocity of crowd by the slope of the stairs which is recommended by Architectural Institute of Japan.

A Study on the Properties of Fire Endurance and Spalling of High Performance RC Column with the Finishing and Covering Material (고성능 RC 기둥의 마감재 변화에 따른 폭열 및 내화특성에 관한 연구)

  • Han, Cheon-Goo;Hwang, Yin-Seong;Ji, Suk-Won;Kim, Kyoung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.143-152
    • /
    • 2006
  • High performance concrete(HPC) has been widely used in high-rise building. The HPC has several benefits including high strength, high fluidity and high durability. However, spalling is susceptible to occur in HPC and HPC also tends to be deteriorated in the side of fire resistance performance at fire. This paper investigated the spalling prevention of high performance RC column. Control concrete showed severe failure and a case of concrete with fire enduring spraying material exhibited more severe spalling failure than even control concrete. In addition, concrete with fire enduring paint reported the most favorable spalling resistance effect for preventing spall, compared with other concrete covered with finishing materials, such as fire enduring spraying material, gypsum board, marble board and fire enduring PC board. Meanwhile, concrete adding 0.1% of PP fiber demonstrated spalling resistance performance after 3hours load bearing test.

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.

Real-Time Location Identification of Indoor Rescuees at Accident Sites and Location-Based Rescue Response (사고 현장 실시간 실내 인명 위치확인 및 구조대응 연구)

  • Ko, Youngjoo;Shin, Yongbeom;Yoo, Sangwoo;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.46-52
    • /
    • 2021
  • In this study, the on-site location identification and response system was proposed by accurately checking the location information of rescue requesters in the buildings using the smartphone Wi-Fi AP. The location server was requested to measure the strength of the Wi-Fi AP at least 25 times at 8 different building location points. And the accuracy of the position and the error range were checked by analyzing the coordinate values of the received positions. In addition, the response time was measured by changing the conditions of location information in three groups to compare the response time for saving lives with and without location information. The minimum and maximum error values for the eight cases were found to be at least 4.137 m and up to 14.037 m, respectively, with an average error of 9.525 m. Compared to the base transceiver station (BTS) based position error value of 263m, the range could be reduced by up to 93%. When the location information was given, it took 10 minutes and 50 seconds to save lives; however, when there was no location information at all, rescue process took more than 45 minutes. From this research effort, it was analyzed that the acquisition of the location information of rescuees in the building using the smartphone Wi-Fi AP approach is effective in reducing the life-saving time for on-site responses.

A study on damage prediction analysis for styrene monomer fire explosion accidents (스티렌 모노머 화재폭발사고 피해예측 분석에 관한 연구)

  • Hyung-Su Choi;Min-Je Choi;Guy-Sun Cho
    • Industry Promotion Research
    • /
    • v.9 no.2
    • /
    • pp.37-44
    • /
    • 2024
  • This study selected the worst-case scenario for fireball and vapor cloud explosion (VCE) of a styrene monomer storage tank installed in a petrochemical production plant and performed damage prediction and accident impact analysis. The range of influence of radiant heat and overpressure due to fireball and vapor VCE during the abnormal polymerization reaction of styrene monomer, the main component of the mixed residue oil storage tank, was quantitatively analyzed by applying the e-CA accident damage prediction program. The damage impact areas of radiant heat and explosion overpressure are analyzed to have a maximum radius of 1,150m and 626m, respectively. People within 1,150m of radiant heat of 4kW/m2 may have their skin swell when exposed to it for 20 seconds. In buildings within 626m, where an explosion overpressure of 21kPa is applied, steel structures may be damaged and separated from the foundation, and people may suffer physical injuries. In the event of a fire, explosion or leak, determine the risk standards such as the degree of risk and acceptability to workers in the work place, nearby residents, or surrounding facilities due to radiant heat or overpressure, identify the hazards and risks of the materials handled, and establish an emergency response system. It is expected that it will be helpful in establishing measures to minimize damage to workplaces through improvement and investment activities.

Strength Evaluation of High-Strength Concrete Specimens within Reinforcing Bars (철근이 포함된 고강도 콘크리트 공시체의 강도평가)

  • Ko, Hune-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.92-97
    • /
    • 2018
  • Recently, the safety issue of high-rise concrete buildings damaged by fire, helicopter collisions, earthquakes, and faulty construction has attracted a great deal of interest. It is essential to know the strength of the concrete in order to accurately evaluate its safety for the reinforcement of these buildings. The core drilling method is considered to be the most effective method of assessing the compressive strength of concrete. However, it is very difficult to retrieve the core without the reinforcing bars, because buildings made with high-strength concrete are overcrowded with reinforcing bars. These reinforcing bars are often present in the core specimens, but there are few research studies and no regulations concerning the assessment of the strength of the concrete for high-strength core specimens within reinforcing bars. The purpose of this study is to investigate the effects of the reinforcement arrangement on the strength of the concrete and to present the quantitative values. To complete this research, the compressive strengths of different types of concrete with two different strengths (40 MPa and 60 MPa), two reinforcing bar diameters (10 mm and 12 mm), and 15 types of specimens with or without reinforcement arrangements were prepared and tested. As a result, the strength of the cylinders whose volume is less than or equal to the reinforcement volume of $53.1cm^3$ (about 4 - 13 mm) was predicted to have a low value of up to 60% of the strength of the cylinders without reinforcement.

A Study on the Performance and the Improving Methods of the Building Fire Compartment under the Domestic Fire Safety Regulations (국내 방화규정에 따른 건축물 방화구획 성능 및 개선방안에 관한 연구)

  • Chun, Woo-Young;Lee, Kwang-Won;Lee, Ji-Hee;Kim, Wha-Jung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.19-24
    • /
    • 2008
  • Recently, the buildings have gradually become higher, more massive and more complex with high growth of economy and varieties of the patterns of people's living. Therefore we study a performance and Improving Methods of the fire compartment as a measure to minimize the damage of the people and property from the fire. Currently, under the economic crisis situation, we do not consider about prevention of disaster safety enough; safety investment evasion, safety carelessness, and management relaxation etc. Also in the aspect of regulation system, industrial technology and plan engineering, Korean techniques of preventing fire disasters are far behind of other advanced nations. At this point, we are in need of improving about it. When considering like this situation, we need more studies on the practical improvement in order to assure fire prevention for buildings. The fire compartment prevent from magnifying the fire to the wide area by compartment into specific area. From this, it is possible to minimize fire damage and property and secure emergency exit for life safety. This fire compartment has primary function to extinguish fire easily, and the openings and penetrations are important passage which makes the smoke and fire go away from the fire area to the contiguous space. This study suggests improving methods of domestic fire compartment efficiency standard through comparative analysis of overseas advanced provision and domestic provision about base element of the building fire prevention.

  • PDF