• Title/Summary/Keyword: 건설안전교육

Search Result 228, Processing Time 0.027 seconds

Development and Effectiveness Analysis of Workshop Program for Child Safety Map Making (아동안전지도 제작을 위한 워크숍 프로그램 개발 및 효과분석)

  • Son, Dong-Pil;Lee, Kyung-Hwan;Chae, Han-Hee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.7
    • /
    • pp.109-117
    • /
    • 2019
  • Recently, child safety map making education has attracted attention as a way to reduce crimes against children. In Korea, the Ministry of Gender Equality and Family organized a child safety map making education program in 2011. The program's manual was revised in 2013 and the Ministry implemented it as a project to promote the rights of women and children. Child safety map making education aims to raise a child's understanding of their neighborhood, to have voluntary control and normal consciousness as a local inhabitant, to be aware of wrong behavior and crime, and to be part of creating a safe urban environment. However, when compared to educational programs in other major developed countries, the child safety map making education program in Korea currently does not improve a child's awareness of their surroundings. In this workshop study, we proposed and ran a new program to improve children's awareness of their environment based on the active participation of children in the existing safety map educational program. The workshop was held for 4 weeks for 48 students from 5th and 6th grade at Osan Daeho Elementary School. We analyzed this new program's effects with the following results. First, an analysis of the effects of the program on children's recognition of safe and dangerous spaces revealed that their understanding of these spaces increased by 30.4% after the workshop. The safety-related factor in the mind map key concept increased from 0.94 to 4.94, indicating that the children's perception of neighborhood risk and safety factors improved. Second, the analysis of the effects of the program on the children's coping ability in dangerous situations showed that their understanding of how to deal with dangerous situations increased by 11.3%. The children's understanding of facilities they could ask for help, such as police boxes and child safety guard houses, improved by 17.9%. Third, analysis of the effects of child safety map making education on children's understanding of their neighborhood, their perception of responsibility in the neighborhood, and their neighborhood attachment showed that these levels of children's understanding of the neighborhood improved by 6.0% after the workshop.

Establishment and Application Plan of Validation System for APR1400 Digital Control System (APR1400 디지털제어계통 검증시스템 구축 및 활용방안)

  • Kang, Sung-Kon;Ko, Do-Young;Ye, Song-Hae
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.429-430
    • /
    • 2008
  • 본 논문은 전기출력이 1400 MWe급으로 개발된 첨단 원자력 발전소인 APR1400(신형겨수로 1400) 제어계통에 적용되는 디지털시스템의 설계 및 성능 검증을 위해 개발 중인 디지털제어계통 검증시스템에 관한 것이다. APR1400 디지털제어계통은 발전소 출력 제어 및 안전운전과 관련 된 중요 기능들을 수행하며, 기존 원자력발전소와 달리 단일 디지털 Platform을 적용하고, Multi-Loop 개념과 네트워크을 적용하여 Controller와 케이블 수량을 줄인 특징을 가지고 있다. 이와 같을 설계는 지금가지 원자력발전소에는 적용된 적이 없기 때문에 사용자 측면에서는 디지털 제어 계통 설계 및 성능 관점에서의 검증을 위한 시스템이 요구되었다. 현재는 APR1400 시뮬레이터(발전소 모델링을 통한 모의시스템)를 이용한 검증시스템을 1차적으로 구축한 상태에 있으며, 시스템 전체 시험을 진행 중에 있다. 특히, 이번에 개발 중인 검증시스템은 구성이 간단하고 사용이 편리한 장점을 지니고 있을 뿐만 아니라 다양한 고장상황을 재현해 봄으로써 디지털제어계통의 성능을 확인해 볼 수 있는 특징을 보유하고 있다. 본 검증시스템의 활용방안으로는 첫째, 계통설계의 구현 가능성 관점에서의 확인시험을 수행하는 방안, 둘째, 발전소 시운전 착수 전 시운전요원 교육에 활용하는 방안, 셋째, 발전소 설계 변경 필요 시 설계 변경에 따른 영향 파악, 넷째, 디지털제어계통 유지보수 기술 습득 등에 효과적으로 활용 할 수 있을 것으로 본다. AFR1400 디지털제어계통은 현재 건설 중인 신고리 3,4호기 원자력발전소에 적용될 예정이며, 향후에는 해외 원자력 수출을 위한 기반기술로 활용될 수 있을 것으로 확신한다.

  • PDF

Planning and Establishment of Sejong City Smart City (세종시 스마트시티 구상 및 수립 방안)

  • Park, Jungsu;Jung, Hanmin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.161-163
    • /
    • 2021
  • This urban centralization is expected to develop rapidly, with 75% of the population living in the city by 2035. Large cities are becoming unsustainable due to side effects such as environmental pollution, severe traffic jams, excessive energy depletion, and destruction of the natural ecosystem. In addition, the happiness index of citizens of large cities is also falling because of high crime rates and safety accidents, the work-life imbalance caused by inequality and polarization, and overly competitive education. To solve this problem, Smart City, an IT-based future city model, was born. The Korean government is also actively attempting to improve urban competitiveness and promote sustainable development through efficient construction and operation of smart cities as a national focus project. To support the effort, we review the basic directions and strategies of Sejong City's Smart City service infrastructure based on the comprehensive national land plan, Smart City plan, and Smart City strategy plan.

  • PDF

Management of Automated Vacuum Waste Collection Systems in Suburban Apartment Complexes (신도시 아파트단지의 생활폐기물 자동집하시설 운용 및 관리실태)

  • Oh, Jeongik;Lee, Hyunjeong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.2
    • /
    • pp.56-62
    • /
    • 2016
  • The purpose of this research is to explore both on-site manager's and resident's assessment of the Automated Vacuum Waste Collection System (AVWCS) in suburban apartment complexes. In doing so, a self-administered questionnaire survey was conducted in 10 districts and their 11 apartment complexes in the Seoul Metropolitan Area. The main findings can be summarized as follows: the managers considered the AVWCS to be economically efficient and environmentally fiendly, and suggested that the system be managed in a more professional way, with an advanced technology and by more qualified technicians. The recommendation was related to residents' complaints and frequent mechanical failures frequently occurring in waste inlets and waste transport piping of the system. For residents using the system, the system was satisfactory, and should be necessarily improved with more user-friendly features. Further, most comments made by the residents were relevant to waste inlets such as safety, cleanliness, prompt repair, odor reduction, waste separation. It's of significant to train residents with how to properly use the system, which is expected to substantially fall a number of residents' complaints. Therefore, both professional management of AVWCS and regular workshops on how to utilize it are crucial in order to heighten its strengths.

Investigation on the Preparation Method of TiO2-mayenite for NOx Removal (질소산화물 제거를 위한 TiO2-mayenite 제조 방법에 관한 연구)

  • Park, Ji Hye;Park, Jung Jun;Park, Hee Ju;Yi, Kwang Bok
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.304-310
    • /
    • 2020
  • In order to apply a photocatalyst (TiO2) to various building materials, TiO2-mayenite was prepared in this study. The TiO2 was synthesized using the sol-gel method by fixing titanium isopropoxide (TTIP) and urea at a ratio of 1 : 1. Later, they were calcined in a temperature range of 400-700 ℃ to analyze the properties according to temperature. BET, TGA, and XRD were used to analyze the physical and chemical properties of TiO2. The nitrogen oxide removal test was confirmed by measuring the change in the concentration of NO for 1 h according to KS L ISO 22197-1. The prepared TiO2 samples exhibited an anatase crystal structure below 600 ℃, and TiO2 (urea)-400 showed the highest nitrogen oxide removal rate at 2.35 µmol h-1. TiO2-mayenite was prepared using two methods: spraying TiO2 dispersion solution (s/s) and sol-gel solution (g/s). Through BET and XRD analysis, it was found that 5-TiO2 (g/s) prepared by spraying a sol-gel solution has maintained its crystallinity even after heat treatment. Also, 5-TiO2 (g/s)-500 showed the highest removal rate of 0.55 µmol h-1 in the nitrogen oxide removal test. To prepare TiO2-mayenite, it was confirmed that mayenite should be blended with TiO2 in a sol-gel state to maintain the crystal structure and exhibit a high nitrogen oxide removal rate.

Compressive and Flexural Properties of Concrete Reinforced with High-strength Hooked-end Steel Fibers (고강도 후크형 강섬유로 보강된 콘크리트의 압축 및 휨 성능)

  • Wang, Qi;Kim, Dong-Hwi;Yun, Hyun-Do;Jang, Seok-Joon;Kim, Sun-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.209-217
    • /
    • 2021
  • This paper investigates the effect of high strength hooked-end steel fiber content and aspect ratio on the compressive and flexural performance of concrete. A total of ten mixtures were prepared and tested. Concretes with specific compressive strength of 30 MPa were reinforced with three different aspect ratios (l/d) of steel fibers 64, 67, and 80 and three different percentages of steel fibers 0.25, 0.50, and 0.75% by volume of concrete. Tensile strengths of steel fibers with l/d of 64, 67, and 80 are 2,000, 2,400, and 2,100 MPa, respectively. The compressive and flexural properties of plain and steel fiber-reinforced concrete (SFRC) mixtures were evaluated and compared. The experimental results indicated that the incorporation of high-strength hooked-end steel fibers had significant effects on the compressive and flexural performance of concrete. With the increase of steel fiber content, compressive performances, such as Poisson's ratio and toughness, of concrete were improved. The steel fibers with the least l/d of 67 resulted in a larger enhancement of compressive performances. The residual flexural strength, that is, post-cracking flexural resistance and toughness, of concrete is mainly depended on the dosage and aspect ratio of steel fibers. The residual flexural strength at serviceability (SLS) and ultimate limit state (ULS) defined in fib Model Code 2010 (MC2010) is increased as the fiber content and aspect ratio increase.

Effect of Phase Change Material on Hydration Heat of Mortar with Fly Ash and Blast Furnace Slag (상전이물질이 플라이애시 및 고로슬래그를 혼입한 모르타르의 수화발열에 미치는 영향)

  • Nam, Yi-Hyun;Jang, Seok-Joon;Kim, Sun-Woong;Park, Wan-Shin;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Phase change material(PCM) has the capacity to absorb or release energy in heat when the phase changes. This study conducted to investigate the effect of strontium-based PCM on the hydration heat and mechanical properties of mortar with fly ash and blast furnace slag. The amounts of PCM were 1%, 2%, 3%, 4%, and 5% by the cementitious materials weight. The tests about mortar flow, semi-adiabatic temperature rise, compressive and flexural strength tests were carried out for twelve types of mortar mixtures. The test results indicated that the use of PCM was effective to reduce hydration heat and retard hydration of mortar with industrial by-products. In particular, the heat generation rate of mortars with fly ash was lower than that of mortars with blast furnace slag. The compressive strength of mortar with fly ash and blast furnace slag were decreased with increasing PCM ratio.

Sick Building Syndrome in 130 Underground Workers (지하상가 근무자의 건강 장애에 관한 실태조사)

  • Joo, Ree;SaKong, Joon;Chung, Jong-Hak;Park, Sang-Whan;Kim, Dong-Hee;Kim, Dong-Min;Choi, Eun-Kyong;Cho, Hyun-Geon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.325-340
    • /
    • 1998
  • A cross-sectional study was conducted to evaluate the relationship between sick building syndrome(SBS) and the environmental factors affecting SBS on 130 underground workers and 60 controls. The study consisted of 1) a review of environmental condition 2) measurement of temperature, $O_2$, $CO_2$, CO, and formaldehyde and 3) a questionnaire survey of symptom prevalence and perception of environmental conditions using indoor Air Quality questionnaire recommended by National Institute for Occupational Safety and Health. Bronchitis and dust allergy were more prevalent in underground workers significantly(p < 0.05). Among the 18 symptoms related to the indoor air pollution, the experience rate of dry, itching or irritated eyes, sore or dry throat, chest tightness, tired or strained eyes and dry or itchy skin symptom was significantly different between the underground workers and controls. The diagnostic criteria of SBS was defined as at least 1 symptom is experienced 1-3 times a week during the last 1 month among 18 indoor air pollution related symptoms which can be relieved by moving out of the underground. Applying the criteria, the mean symptom score was significant higher in underground workers than controls significantly (p < 0.05). These resalts indicated that underground workers are under inappropriate ergonomic and physical condition and inadequate ventilation. Their experience rate of symptoms related to indoor air pollution and prevalence of SBS was significantly higher than controls. To reduce the prevalence of SBS of underground workers, the surveillance system of indoor air quality, restriction of using fuel in underground and legislative regulations for the environment are needed to establish a better indoor air quality. Early detection, treatment and prevention of SBS through medical attention is also needed.

  • PDF