• Title/Summary/Keyword: 건물하중

Search Result 437, Processing Time 0.027 seconds

Response Analysis and crack Pattern Evaluation of Two Story Masonry Structure under the seismic Load (2층 조적조의 지진하중에 의한 거동해석 및 균열평가)

  • 김희철;이경훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.179-190
    • /
    • 1998
  • All brick masonry buildings are constructed without any structural limitation under earthquake load, in Korea. However, it is necessary to evaluate response for seismic loads since the number of earthquake occurances in Korea is increasing. In this paper, the load resisting capacities of brick masonry buildings are investigated by finite element analysis method and the response due to seismic load are analyzed by applying 0.12g earthquake load. It was observed that the two story masonry building is not safe under the 0.12g earthquake load, especially at the first floor. The cracks were occurred under the bond beam and around the openings due to the stress concentration.

  • PDF

Effect of Dampers on Preventing Progressive Collapse in Steel Frames (감쇠기가 철골조 건물의 연쇄붕괴 방지에 미치는 효과)

  • Lee, Seung-Jun;Choi, Hyun-Hoon;Kim, Jin-Koo;Huynh, Chanh Trung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.154-157
    • /
    • 2010
  • 본 논문에서는 비선형 동적해석법을 이용하여 감쇠기의 적용이 철골조 건물의 연쇄붕괴 방지에 미치는 영향을 평가하였다. 단자유도 구조물에서 감쇠비의 변화에 따라 폭발하중이 구조물의 응답에 미치는 영향을 분석하였고, 15층 3경간 철골조 건물에서는 일정한 감쇠비 하에서 경간을 6m, 9m, 12m로 달리 하면서 감쇠기 설치 효과를 비교하였다. 단자유도 시스템의 경우 감쇠비가 증가 할수록 폭발하중에 의한 진동이 빠르게 감소하고 변위의 감소폭도 커지는 경향을 보였다. 15층 철골조 건물에서도 역시 감쇠기를 설치할 경우 수직 처짐 및 초기 진동을 제어하는 효과가 있었다. 구조물의 경간이 증가하여 수직 변위가 증가 할수록, 감쇠기에 의해 소산된 에너지도 증가하기 때문에 수직 처짐 제어효과가 큰 것으로 나타났다.

  • PDF

Co-rotational Plane beam-Dynamic tip load를 이용해 외팔보 진동에 영향을 미치는 요인 분석과 지진 상황 시 건물의 면진 주기 설정

  • Jo, Seong-Bae;Mun, Byeol
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.269-273
    • /
    • 2015
  • 처음 에디슨 경진대회를 준비할 때 업로드 되어 있는 다양한 프로그램을 보면서 어떤 주제를 선정할 지 고민을 하던 중, 눈에 들어온 프로그램은 서울대학교에서 제작한 Co-rotational Plane beam-Dynamic tip load이란 프로그램이었다. 위 프로그램은 한쪽 단이 고정된 외팔보(cantilever beam)의 끝단에 하중을 시간에 관련된 함수(sin, cos)로 주어 각 절점에서의 변위(X, Y), 속도 그리고 가속도를 알려주는 프로그램이다. 우리는 이 프로그램을 이용해서 외팔보 끝단의 진동 형태와 주기가 어떤 요인(단면의 모양, 재료의 성질, 가하는 하중의 진동수 등)에 의해서 변하는지 분석할 수 있었다. 거기서 더 나아가 하중을 실제 지진상황에서의 크기와 유사하게 주고 위 프로그램에서의 보의 거동(진동 주기, 진동 변위 등)을 건물의 거동이라 가정했을 때 면진 주기를 얼마로 설정해야하는지도 알 수 있었다.

  • PDF

Comparison of Order Reduction Methods for Seismic Analysis (지진해석을 위한 차수축소기법의 비교)

  • Han, Jeong-Sam;Kwon, Ki-Beom
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.739-742
    • /
    • 2011
  • 일반적으로 고층건물이나 교량 등의 지진하중 하에서의 내진 성능 향상을 위해서는 과도지진해석을 수행하는 것이 필요하다. 본 논문에서는 이러한 지진해석을 수행하는데 Krylov 부공간 축소기법을 이용하는 것을 제안하고 기존의 모드중첩법을 이용한 축소기법과 비교하였다. 해석에서 지진하중은 El Centro Earthquake (1940)의 데이터를 이용하였으며 고층건물 모델을 이용하여 두 방법을 정확성과 효율성 측면에서 비교한 수치결과를 제시하였다.

  • PDF

S3D

  • 소프트웨어센터
    • Computational Structural Engineering
    • /
    • v.2 no.3
    • /
    • pp.43-45
    • /
    • 1989
  • 건축구조물의 삼차원 거동을 해석하기 위한 S3D는 한국과학기술원 이동근 교수에 의하여 개발되었으며 소프트웨어센터를 통하여 보급되고 있다. 보와 기둥 및 전단벽 등으로 구성된 건축구조물의 삼차원 거동을 효율적으로 해석하기 위하여 S3D에는 여러가지의 특수한 기법이 사용되고 있으며 개인용 전자계산기를 사용하여 사무소건물, 아파트 호텔, 병원 및 학교건물 등과 같이 규칙적인 형태를 대형 건축 구조물에 대한 삼차원 거동을 짧은 시간내에 해석 할 수 있도록 개발되었다. 우리나라의 내진설계 기준에 의한 지진하중 산정 및 층간변위, 우발비틀림 모멘트 등이 손쉽게 계산될 수 있으며 풍하중 등의 횡력에 대한 해석도 가능하다.

  • PDF

자기유변유체 댐퍼를 이용한 대형구조물의 반능동제어

  • 윤정방;구자인;김상범;전준보
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.127-132
    • /
    • 2001
  • 자기유변유체감쇠기를 이용한 반능동 제어 시스템은 최근에 개발되어 승용차의 승차감 향상을 위한 진동제어에 사용되고 있다. 본 연구에서는 바람, 지진, 파랑 등에 대한 대형구조물의 진동제어를 위한 MR 감쇠기의 적용성을 분석하기 위하여, 미국 토목학회에서 제안한 76층 건물의 풍하중에 대한 진동제어에 관한 Benchmark Problem에 대하여 수치모의 해석을 수행하였다. 연구결과로부터, 풍하중에 대한 고층 건물의 진동제어를 위하여 MR 감쇠기를 이용한 반능동 제어의 성능은 능동형 동조질량 감쇠기의 성능과 유사함을 확인할 수 있었다.

  • PDF

Seismic Behavior of Steel Structure with Added Viscoelastic Dampers under Strong Earthquake Ground Motions (점탄성 감쇠기를 설치한 강구조 건물의 강지진 하중에 의한 거동 연구)

  • Oh, Soon Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.111-120
    • /
    • 1993
  • This paper summarizes an experimental and analytical study on the application of viscoelastic dampers as energy dissipation devices in structural applications. It can be concluded the viscoelastic dampers are effective in reducing excessive vibrations of structures under strong earthquake ground motions. It is also found that the modal strain energy method can be used to reliably predict the equivalent structural damping, and the seismic response of a viscoelastically damped structure can be accurately estimated by conventional modal analysis techniques. Based on the above studies, a design procedure for viscoelastically damped structures is presented. This design procedure fits naturally into the conventional structural design flow chart by including damping ratio as an additional design parameter.

  • PDF

Excitation and System Identification of a Full-Scale Five-Story Structure for the Application of Viscoelastic Dampers (점탄성 감쇠기 적용을 위한 실물크기 5층 건물의 가진 및 시스템 식별)

  • 민경원;이상현;김진구;이영철;이승준;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.1-7
    • /
    • 2003
  • Excitation and system identification are carried out for a full-scale five-story structure to obtain fundamental data which will be used for the design of viscoelastic dampers, The hybrid mass driver(HMD) installed on the fifth floor was employed as external exciter to provide excitation for the building, Each floor response was measured and processed to find out where and how the viscoelastic dampers are located and designed. The sine-sweep and white noise loadings were applied to the structure by the HMD to obtain dynamic characteristics such as natural frequencies, damping ratios, and modes, The identified building was experimentally investigated again with the designed viscoelastic dampers installed at inter-stories to obtain the response behavior in the companion paper.

Experimental study on the tunnel behavior induced by the excavation and the structure construction above existing tunnel (기존터널 상부지반 굴착 후 구조물 설치에 따른 터널거동에 관한 실험적 연구)

  • Cha, Seok-Kyu;Lee, Sangduk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.3
    • /
    • pp.640-655
    • /
    • 2018
  • Recently, the construction of the urban area has been rapidly increasing, and the excavation work of the ground has been frequently performed at the upper part of the existing underground structures. Especially, when the structure is constructed after the excavation of the ground, the loading and unloading process in the ground under the excavation basement can affect the existing underground structures. Therefore, in order to maintain the stability of the existing underground structure due to the excavation of the ground, it is necessary to accurately grasp the influence of the excavation and the structure load in the adjoining part. In this study, the effect of the excavation of the ground and the new structure load on the existing tunnel was experimentally implemented and the influence of the adjacent construction on the existing tunnel was investigated. For this purpose a large testing model with 1/5 scale of the actual size was manufactured. The influence of ground excavation, width of the load due to new structure, and distance between centers of tunnel and of excavation on the existing tunnel was investigated. In this study, it was confirmed that the influence on the existing tunnel gets larger, as the excavation depth get deeper. At the same distance, it was confirmed that the tunnel displacement increased up to three times according to the increase of the building load width. That is, the load width influences the existing tunnel larger than the excavation depth. As the impact of the distance between centers of tunnel and of excavation, it was confirmed that tunnel crown displacement decreased by 48%. The result showed that a tunnel is located in the range of 1D (D: tunnel diameter) from the center of excavation, the effect of excavation is the largest.