• Title/Summary/Keyword: 건물구조체

Search Result 154, Processing Time 0.026 seconds

Thermal Performance of Wooden Building Envelope by Thermal Conductivity of Structural Members (목조건축물 구조부재의 열전도율에 따른 건물외피의 단열 성능)

  • Kim, Sughwan;Yu, Seulgi;Seo, Jungki;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.515-527
    • /
    • 2013
  • Building energy simulations which are mainly used in Korea have evaluated the building energy performance with the different thermal conductivity of construction materials. In order to evaluate the energy consumption accurately, the difference in thermal conductivity of the wood used in stud for wooden structure was confirmed from the each simulation. In addition, the thermal transmission of building members and the thermal bridge at the conjunction of building members according to thermal conductivity from each simulation programs were researched. The thermal conductivity of pine that has the largest variation among the energy simulations was applied to the thermal properties of studs in wooden structure. The maximum error between the maximum and minimum thermal transmission of roof, wall, and floor slab was $0.023W/m^2{\cdot}K$. Plus, that thermal bridge at Rafter junction on the roof, roof-wall joint, and floor slab-wall joint was $0.025W/m{\cdot}K$. The heat transfer image for changes in temperature and the heat exchange were analyzed by HEAT2 program. The distorted temperature lines were found around the insufficient insulated connection parts. It was predicted that the temperature at the distorted parts in the analyzed image was lower than that of the other portion of the other structures.

Experimental Study of System Identification for Seismic Response of Building Structure (건축구조물의 지진응답제어를 위한 시스템 식별의 실험적 연구)

  • 주석준;박지훈;민경원;홍성목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.4
    • /
    • pp.47-60
    • /
    • 1999
  • The stability and efficiency of structural control systems depend on the accuracy of mathematical model of the system to be controlled. In this study, state equation models of a small scale test structure and an AMD(active mass damper) are obtained separately using OKID(observer/Kalman filter identification) which is a time domain system identification method. The test structure with each floor acceleration as outputs is identified for two inputs - the ground acceleration and the acceleration of the moving mass of AMD relative to the installation floor - individually and the two identified state equation models are integrated into one by model reduction method. The AMD is identified with the motor control signal as an input and the relative acceleration of the moving mass as an output, and it is shown that the identified model has large damping ratio and phase shift. The transfer functions and the time histories reconstructed from the identified models of the test model and the AMD match well with those measured from the experiment.

  • PDF

Hysteresis Performance of CFT Columns subjected to Low Axial Force and Cyclic Lateral Loads (저축력과 반복수평력을 받는 콘크리트충전 강관기둥의 이력특성)

  • Choi, Sung Mo;Kang, Suk Bin;Kim, Dae Joong
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.207-217
    • /
    • 2003
  • The Concrete Filled Steel Tube (M) Column has excellent structural capacities that are in accordance with the interaction effect between the steel tube and concrete. CFT structure has been focussed on a struc tural system for high-rise buildings. The purpose of this study is to evaluate the strength and deformation capacities of CFT columns that are subject to constant axial and cyclic lateral load. The test parameters are diameters to the thickness ratio of the steel tube, axial load ratios, and the shapes of the tube. Total eighteen specimens were fabricated to clarify the energy absorption capacity of the CFT columns. Experimental results were summarized for their ultimate strengths and deformation capacities.

Bending Behaviour of Composite Slab Using a New-Shaped Steel Deck Plate and Expanded Metal (신형 데크플레이트와 철판망을 적용한 합성슬래브의 휨 거동)

  • Kim, Myoung Mo;Eom, Chul Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.403-412
    • /
    • 2003
  • The composite metal deck plate system has been widely used for office structures. Recently, however, the flat deck plate has been developed to apply the composite slab system to residential structures. Reduction in construction cost and time can be expected by using expanded metal instead of wire mesh as crack control reinforcements. This study proposed a composite slab system composed of a new-shaped steel deck plate and expanded metal. Twelve specimens were tested to evaluate the structural performance of the new composite slab system. The test results were summarized mainly in terms of maximum load carrying capacity and failure behaviors of each specimen.

Ag/Ta/glass 다층박막의 Ta seeding이 전기적 광학적 특성에 미치는 효과

  • Park, Seon-Ho;Jo, Hyeon-Cheol;Lee, Gi-Seon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.69-69
    • /
    • 2010
  • 현대 건축물에서 건물에너지의 손실은 대부분은 창호를 통하여 유출되어지고 있으며 에너지 절감을 위해서는 창호의 단열성을 향상시켜야한다. 저방사(Low Emissivity) 코팅유리는 건축물의 냉난방비용을 절약할 수 있는 대표적인 건축재료로써 외부에서 유입되는 태양광의 가시광선 영역은 높은 투과율을 가지면서 적외선 영역과 겨울철 실내 난방열을 반사하는 특징을 지니는 박막코팅기술이다. 이 코팅유리는 일반적으로 유전체/금속/유전체 다층박막 구조로 되어있으며, 유전체층은 내구성 증진과 금속층의 반사를 낮추어 투과율이 향상된다. 금속층은 적외선영역의 복사에너지를 반사하는 역할을 하며 전도성이 우수한 Ag 또는 Au, Pt 등을 이용하고 있다. Ag의 경우 산화물기판 위에 증착하였을 경우 island 성장을 하고 이들의 합체는 전기적, 광학적 특성에 큰 영향을 미치게 된다. 본 연구에서는 DC-sputtering법으로 제조된 Ag/glass, Ag/Ta/glass 박막을 제조하고 Ta seeding이 Ag의 전기적, 광학적 성질에 미치는 영향을 관찰하였다. 박막의 표면 미세구조는 FE-SEM(Field Emission Scanning Electron Microscope)과 AFM(Atomic Force Microscope)으로, 표면저항은 4 point probe로 분석하였다. 광투과율은 UV-Vis spectroscopy와 FT-IR로 측정하였으며 측정파장범위는 각각 200~1100nm와 1400~2400nm 이다.

  • PDF

Response scaling factors for nonlinear response analysis of MDOF system (다층건물의 비선형 반응해석을 위한 반응수정계수)

  • 한상환;이리형
    • Computational Structural Engineering
    • /
    • v.8 no.3
    • /
    • pp.103-111
    • /
    • 1995
  • Evaluating nonlinear response of a MDOF system under dynamic stochastic loads such as seismic excitation usually requires excessive computational efforts. To alleviate this computational difficulty, an approximation is developed in which the MDOF inelastic system is replaced by a simple nonlinear equivalent system(ENS).Me ENS retains the most important properties of the original system such as dynamic characteristics of the first two modes and the global yielding behavior of the MDOF system. The system response is described by the maximum global(building) and local(interstory) drifts. The equivalency is achieved by two response scaling factors, a global response scaling factor R/sub G/, and a local response scaling factor R/sub L/, applied to the responses of the ENS to match those of the original MDOF system. These response scaling factors are obtained as functions of ductility and mass participation factors of the first two modes of structures by extensive regression analyses based on results of responses of the MDOF system and the ENS to actual ground accelerations recorded in past earthquakes. To develop the ENS with two response scaling factors, Special Moment Resisting Steel Frames are considered. Then, these response scaling factors are applied to the response of ENS to obtain the nonlinear response of MDOF system.

  • PDF

A Study on the Enhancement of Fire Resistance Function in Primary Structure Department of Building Type Traditional Market (건물형 전통시장 화재발생시 피난안전성 확보를 위한 규모별 주요구조부 내화보강 연구)

  • Jang, Hye-Min;Hwang, Jung-Ha
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.87-95
    • /
    • 2020
  • This study evaluates the safety of an asylum through a fire simulation of building Type traditional markets. We derive the building's indoor temperature, use the observed variation in temperature gradient to calculate the temperature of the main structure, and finally compares the time required to attain the limit temperature of the structure its time of escape. To ensure improved security of the asylum, the government has proposed a fire-resistance improvement plan for the major structural parts of buildings are not safe with thickness of 0.01 m and 0.035 m. F.ire-resistance reinforcement for small - and medium-sized vehicles is more than 0.025 m, in thickness; moreover safety can be ensured for medium and large-sized vehicles fire using fire resistant reinforcement of over 0.035 m. Accordingly, in order to ensure the safety of an asylum, fire-resistant reinforcement measures may be considered.

A Study on the Fracture Resistance Characteristics of Post-Installed Anchor (후설치 앵커볼트의 파괴저항 특성에 관한 연구)

  • Kim, Doo Hwan;Hwang, Yun Sung;Cha, Young Min;Song, Kwan Kwon;Choi, Kyung Gyp
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.156-156
    • /
    • 2011
  • 중량물 혹은 철골구조물 등을 고정시키는데, 건축구조물의 철골기둥, 터빈 제네레이터 기기등을 콘크리트 구조물에 부착시키기 위해 널리 쓰인다. 1990년대 들어 국내 건물의 리모델링, 보수 및 유지관리의 증가에 따라 앵커의 사용량도 현저히 증가하고 있으나 대부분 고가의 외국산제품을 수입하고 있다. 현재 국내외에 주로 시행되는 앵커타입은 마찰형 앵커이나 마찰형 앵커와 달리 지압형 앵커의 경우, 외국에서는 이미 그 유효성에 대한 인식이 널리 퍼져있으며 각국의 지반조건에 적합한 설계법이 개발되었다. 그러나 국내의 경우 이러한 연구가 미진한 실정이며 이에 대한 연구가 절실한 상황이다. 본 연구에서는 중량물앵커(Heavy Duty Anchor)의 인장시험을 실시하여 내력을 규명하고 도출한 결과를 기존 시험연구 결과와 비교분석하여 기 제안된 이론식들과 사업경제성에대해 보다 깊이있고 정확한 적용성을 입증하는데 본 연구를 수행하였다. 시험을 통한 저강도 파괴시험의 결과 구조부재의 접합부에서 각 시험체마다 뽑힘파괴가 발생하였으며, 뽑힘파괴가 발생한 시험체는 앵커강재의 파괴력 또는 콘크리트의 콘파괴를 발생시키기에는 앵커슬리브의 확장력이 작게 작용되었다. 그 결과, 콘파괴 대신 구조부재의 접합부에서 뽑힘파괴가 발생되었으며 이를 통해 설계시, 앵커의 안정성을 증가시키기 위해 구조부재의 접합부를 연성적이며, 부가여력을 충분히 지니도록 설계하는 것이 효과적인 것으로 나타났다. 고강도 파괴시험의 결과 콘파괴가 발생되었음을 알 수 있는데, 본 시험에 사용된 앵커의 경우 정착위치가 구조물의 연단 모서리 거리와 너무 근접하여 앵커의 내력이 감소하게 되어 콘크리트의 콘강도가 발생되기 전에 먼저 파괴되었다. 따라서 설계시, 앵커의 파괴강도를 증가시키기 위해 앵커의 정착위치를 고려한 설치를 통해 앵커체결과정에서 적정 연단거리를 확보하는 것이 효과적인 것으로 나타났다. 앵커볼트 최소간격과 연단거리에 따른 파괴시험결과 앵커볼트의 간격이 허용범위 내에서 넓어질수록 불균등 부반력의 차는 감소하였으며, 최대 부반력도 감소하였다. 따라서 앵커의 파괴저항강도를 증가시키기 위해서는 허용범위 내에서 앵커볼트의 설치간격을 증가시키는 것이 효과적인 것으로 나타났다.

  • PDF

Development of the Pilot Type Machine for Automation of PHC Pile Cutting Work (PHC 파일 두부정리 자동화를 위한 파일롯타입 장비의 개발)

  • Lee Jeong-Ho;Park Sang-Jun;Jeong Myung-Hoon;Kim Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.173-181
    • /
    • 2003
  • During the last few years, the use of Pre-tensioned spun high strength concrete piles(PHC pile) has been gradually increased in many construction sites. Cutting work of the concrete pile is an important task to crush a part of pile head which is compressed with more than 800$\cal{kg}f/cm^2$. It is usually performed by a crusher and three to four skilled workers. Recent analysis results of the pile cutting work reveal that it frequently makes a lot of cracks which significantly reduce the strength of the pile and is labor-intensive work. The primary objective of this study is to propose conceptual designs for developing an automated pile cutting machine. It is anticipated that the development of the automated pile cutting machine would be able to bring improvements in safety, productivity, quality as well as cost saving.

Development of Ventilation Isolation Design and Material for Vibration Reduction of Road Passing through Buildings (건물을 통과하는 도로의 진동저감을 위한 방진설계 및 방진재 개발)

  • Lee, J.S.;Lee, J.H.;Kim, Dae-Hyeon;Yun, Eun-Jung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1123-1128
    • /
    • 2006
  • 철도 및 도로교통에 의한 건축구조물의 진동, 소음을 저감시킬 수 없는 PO-MAT(Polyurethane Mat) 제품과 다양한 건축물의 진동, 소음이 전달되는 상황에 적용되어 방진효과를 정확하게 예측하는데 사용될 수 있는 설계안을 개발하였다. 개발된 제품은 다공질의 폴리우레탄 탄성체의 조직으로 도로 및 철도의 교통진동의 방진과 연구실, 기계실, 공조실 등의 Floating Floor System 및 건축기초의 내진용으로 사용되고, 실제구조물에 적용하여 진동저감과 충격흡수, 소음저감 효과가 탁월함을 확인하였다.

  • PDF