A Study on the Enhancement of Fire Resistance Function in Primary Structure Department of Building Type Traditional Market  

Jang, Hye-Min (School of Architecture and Civil Engineering, Kyungpook National University)
Hwang, Jung-Ha (School of Architecture, Kyungpook National University)
Publication Information
Fire Science and Engineering / v.34, no.4, 2020 , pp. 87-95 More about this Journal
Abstract
This study evaluates the safety of an asylum through a fire simulation of building Type traditional markets. We derive the building's indoor temperature, use the observed variation in temperature gradient to calculate the temperature of the main structure, and finally compares the time required to attain the limit temperature of the structure its time of escape. To ensure improved security of the asylum, the government has proposed a fire-resistance improvement plan for the major structural parts of buildings are not safe with thickness of 0.01 m and 0.035 m. F.ire-resistance reinforcement for small - and medium-sized vehicles is more than 0.025 m, in thickness; moreover safety can be ensured for medium and large-sized vehicles fire using fire resistant reinforcement of over 0.035 m. Accordingly, in order to ensure the safety of an asylum, fire-resistant reinforcement measures may be considered.
Keywords
Building traditional market; Fire resistance performance; Structural safety; FDS; EURO-CODE;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 I. H. Koo, Y .C. Shin, Y. J. Kwon, H. Yoshihiko and O. Yoshifumi, "A Case Study on the Propagation Process of Market Fire in Korea: in the Case of the Sinjin Market Fire", Proceedings of 2010 Spring Annual Conference, Korean Institute of Fire Science & Engineering, pp. 43-47 (2010).
2 H. M. Jang, Y. H. Bae, J. Y. Son, W. H. Hong and J. H. Hwang, "Evaluation of Evacuation Safety According to the Floor Plan and Internal Layout of Building-type Traditional Markets", Journal of The Korean Society of Living Environmental System, Vol. 26, No. 3, pp. 321-331 (2019).   DOI
3 B. H. Kans, "Properties of High-heated Concrete", Magazine of the Korea Concrete Institute, Vol. 14, No. 2, pp. 17-23 (2002).   DOI
4 J. Spicer, R. Osiander, L. C. Aamodt and R. B. Givens, "Microwave Thermoreflectometry for Detection of Rebar Corrosion", Structural Materials Technology III: An NDT Conference, San Antonio, TX, SPIE, pp. 402-409 (1998).
5 C. W. Lim, K. I. Han, S. J Lee and D. W Lee, "Analysis and Reinforcement Method on the Damaged Structures of Fire", Magazine of the Korea Institute for Structural Maintenance and Inspection, Vol. 16, No. 1, pp. 45-54 (2012).   DOI
6 K. Min, "Structural Fire Design of Steel Structures Using Eurocodes", Journal of the Korean Association for Spatial Structures, Vol. 13, No. 3, pp. 19-25 (2015).
7 "Survey on the Management of Traditional Markets" (2010).
8 H. M. Jang, Y. H. Bae, J. Y. Son, W. H. Hong and J. H. Hwang, "Analysis of Required Safe Egress Time Reflecting the Floating Population of the Medium-sized Traditional Market Building Type", International Conference of Asia Institute of Urban Environment (2018).
9 Daegu Traditional Market Service Agency, "Traditional Market Data Service" (2013).
10 Y. K. Baek, "A Study on the Characteristics of Architectural Form in Urban Space", Master's Thesis, Soonchunhyang University (2014).
11 H. M. Jang, Y. H. Bae, J. Y. Son, W. H. Hong and J. H. Hwang, "A Study on the Occupant Load Factor of the Traditional Market in Daegu", SAREK Summer Annual Conference, pp. 398-401 (2018).
12 S. J. Park, J, S, Lee, D. H. Kang, E, H. Jung, H. S. Jun, S. B. Park and J. S. Lee, "A Study on the Walking Speed and Stretch by Age", Proceedings of 2007 Fall Conference of ESK, pp. 430-434 (2007).
13 J. W. Lim, S. K. Kim, T. W. Kim, S. G. Song, G. C Lee and S. Y. Seo, "FEA for Improving Fire Resistance Capacity of Reinforced Concrete Structures Strengthened with CFRP", Proceedings of the Korea Concrete Institute, Vol. 29 No. 2 pp. 680-680 (2017).