• Title/Summary/Keyword: 강연선

Search Result 208, Processing Time 0.026 seconds

A Methodology for Monitoring Prestressed Force of Bridges Using OFS-embedded Stand (광섬유센서가 내장된 강연선을 이용한 교량의 장력 모니터링 방법)

  • Kim, Jae-Min;Kim, Hyun-Woo;Kim, Young-Sang;Kim, Jin-Won;Yun, Chung-Bang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.287-294
    • /
    • 2008
  • This study proposes a novel method for in service evaluation of tension force of a prestressed 7-wire strand which is frequently employed for retrofitting bridge superstructure. The smart strand is made by replacing the straight king wire of the strand with an instrumented steel tube in which the FBG sensor is embedded. Since the strain of the smart strand can easily be measured using the sensor, it is possible to monitor tension force of the strand during the service. For the sake of demonstrating effectiveness of the proposed strand, we came up with a 7.0m long prototype with 2 FBG sensors, and it is applied as an external tendon to a 6.4m long and 0.6 high RC T-shaped beam. A loading-unloading test has been carried out, and estimated tension forces using the smart strand are compared with measured forces by load cell. The comparison showed that the proposed smart tendon is useful and accurate for monitering tension force of the prestressed tendon.

Investigation on Applicability of 2400 MPa Strand for Posttensioned Prestressed Concrete Girders (포스트텐션 PSC 거더에 대한 2400 MPa급 강연선의 적용성 분석)

  • Park, Ho;Cho, Jae-Yeol;Kim, Jee-Sang
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.727-735
    • /
    • 2012
  • Recently, a high-strength strand of 2400 MPa was developed using domestic technologies. In 2011, KS D 7002 was revised to cover the newly developed high-strength strands to support their practical usage. Presently, however, discussions and evaluations are not sufficient on the mechanical properties of the strands and their performance in structural members. Also, there were no detailed reviews on the need to revise the current design code for practical use of the high-strength strands. In this study, flexural behavior of a member with the high-strength strands was estimated through sectional analysis and a review and comparison of the domestic and foreign design codes were conducted considering the analysis results. Also, the need for the revision of the design code was discussed. Such discussion especially focused on the estimation of the stress in strand, which related with various issues such as determination methods for yield point of strands, time-dependent loss of prestressing force, estimation of stress in strand at member failure, and net strain limit for ductile failure of member. The discussion revealed that some parts in the design code need a revision and the further studies are required.

Pullout Bond Characteristics of Untensioned Prestressing Strand (인장을 가하지 않은 PS강연선의 인발 부착특성)

  • Ha, Sang-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.101-108
    • /
    • 2008
  • The primary objective of this research is a study on the pullout bond characteristics of untensioned prestressing strand in concrete. The bond characteristics of untensioned prestressing strand in concrete differs from that of deformed reinforcing bar. In order to use and design untensioned prestressing strand as deformed reinforcing bar, a study for bond characteristics of the untensioned prestressing strand was progressed. Major test variables are embedment length ($10d_b{\sim}60d_b$), concrete cover (45mm, 70mm, 100m) and diameter of strands. (12.7mm : SWPC7, 9.3mm : SWPC7A) As a results, these showed that average bond stress was decreased as a growing the embedment length, and then showed that the bond performance of untensioned prestressing strand was improved if embedment length was above 60$60d_b$.

Feasibility Study of 2200MPa PS strand in terms of Wedge and Anchor Head (2200MPa급 PS강연선의 적용성 연구(쐐기와 앵커헤드))

  • Kim, Jin-Kook;Lee, Pil-Goo;Lee, Man-Seop
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.145-146
    • /
    • 2009
  • In this paper, feasibility tests of 2200MPa PS strand in terms of wedge and anchor head used currently for 1860MPa PS strand were performed. Static and fatigue tests for PT anchorage systems from 4 companies were conducted in compliance with ETAG013(European Technical Approval Guideline). The test results implied that some of them can be used for 2200MPa PS strand without improvement and some with small improvement.

  • PDF

Experimental Study on the Performance of Korean PS Anchorage System in terms of Load Transfer Test (한국형 PS정착구의 하중전달성능에 관한 연구)

  • Kim, Jin-Kook;Lee, Pil-Goo;Jang, Seok-Youn
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.37-38
    • /
    • 2009
  • In this paper, the load transfer test of Korean PS anchorage system was conducted for 1860MPa PS strand and 2200MPa PS strand. The test is in compliance with ETAG013. All the anchorage system tested satisfied the allowance criteria of the test for 1860MPa PS strand but only one of the anchorage systems for 2200MPa PS strand. In order to generally use 2200MPa PS strand to prestressed concrete structures, new anchorage systems shall be developed.

  • PDF

Effects of Diameter of Cylinder and the Number of Strand on the Bleeding of Cement Paste (실린더 직경과 강연선 개수가 시멘트 페이스트의 블리딩에 미치는 영향)

  • Lee, Jung-Soo;Koh, Kyung-Teak;Ahn, Gi-Hong;Kang, Su-Tae;Kwon, Seung-Hee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.1
    • /
    • pp.38-46
    • /
    • 2016
  • In this study, the bleeding tests were performed to investigate the effects of cement paste(w/c=0.42) on bleeding through varying the number of strand and the diameter of cylinder. The test variables were specified by differing the diameter of cylinder and the number of strand. The bleeding test was performed with respect to all diameter parameters by with or without strand. In addition, the number of strands were specified at four levels, 0, 1, 2, and 3 EA in case of 50 mm cylinder. In case of without strand, the bleeding rate was determined at low level under 2%. Moreover, all of the specimens had similar value in the measurement error. In case of with strand, maximum bleeding rate was 10%. As the diameter of cylinder decreased, the bleeding rate was decreased. The bleeding rate was altered rapidly in between 50 to 100mm of diameter. Even though bleeding rate was increased according to the increase in the number of strand, these tendency for bleeding rate was negligible with the measurement error.

Prestressing Effect of LNG Storage Tank with 2,400 MPa High-Strength Strands (2,400 MPa급 고강도 강연선이 적용된 LNG 저장탱크의 프리스트레싱 효과)

  • Jeon, Se-Jin;Seo, Hae-Keun;Yang, Jun-Mo;Youn, Seok-Goo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.999-1010
    • /
    • 2016
  • High-strength strands have been increasingly applied to recent actual structures in Korea. Structural effect of the increased spacing of sheaths was investigated in this study when the usual 1,860 MPa strands of an LNG storage tank are replaced with 2,400 MPa high-strength strands. First, finite element models of a cylindrical wall of an LNG tank were established and prestressing effect of the circumferential and vertical tendons was considered as equivalent loads. As a result of varying the tendon spacing and prestressing force with the total prestressing effect kept the same, the stress distribution required in design was obtained with the high-strength strands. Also, a full-scale specimen that corresponds to a part of an LNG tank wall was fabricated with 31 high-strength strands with 15.2 mm diameter inserted in each of two sheaths. It was observed that such a high level of prestressing force can be properly transferred to concrete. Moreover, an LNG tank with the world's largest 270,000 kl capacity was modeled and the prestressing effect of high-strength strands was compared with that of normal strands. The watertightness specifications such as residual compressive stress and residual compression zone were also ensured in case of leakage accident. The results of this study can be effectively used when the 2,400 MPa high-strength strands are applied to actual LNG tanks.

Development and Performance Experiment of Iso-tensioning System using Electrical Resistance Loadcell (전기저항식 로드셀을 이용한 균등긴장시스템 개발 및 성능실험)

  • Park, Won-Tae;Chun, Kyoung-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.220-226
    • /
    • 2016
  • Because MS(Multi-Strand) cables consist of many strands, a jacking force is applied to each strand one by one for cable construction. All strands should have an equal tensile force when the last one is wedged. This is the core technology for MS iso-tensioning. In this study, a new MS cable iso-tensioning system was developed for controlling and jacking the high-strength strands, with an ultimate tensile strength of 2,200MPa, for a stay cable of extra-dosed/cable-stayed bridges. The newly developed iso-tensioning system consists of electrical resistance load cells, hydraulic jacking devices, hydraulic pumps, and integrated controllers. Moreover, it is embedded with an algorithm that can control and predict the variations in tensile forces of the Master and Slave strands in real time. Actual experiments were carried out to verify the function and performance of the newly developed system. This system was applied successfully to the stay cable construction of 2nd Tae-in extra-dosed bridge in Gwangyang.

The Bond Characteristics of Strand in Ultra High Performance Concrete (강연선과 초고성능 콘크리트의 부착특성)

  • Park, Jong-Sup;Kim, Byong-Suk;Joh, Chang-Bin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.93-94
    • /
    • 2009
  • In this paper, the bond performance between prestressing strand and Ultra High Performance Concrete members are verified to collect the basis data of UHPC increased in practical uses recently. Concrete pouring direction, strand location and strand size were the main parameters of UHPC. As a result, the initial bond performances are influenced by all above parameters.

  • PDF

Measurement of Transfer Length for a Seven-Wire Strand with FBG Sensors (FBG 센서를 이용한 강연선 전달길이 측정)

  • Lee, Seong-Cheol;Choi, Song-Yi;Shin, Kyung-Joon;Kim, Jae-Min;Lee, Hwan-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.707-714
    • /
    • 2015
  • In this paper, an experimental program has been conducted to investigate transfer length in high strength concrete members pretensioned through a seven-wire strand with FBG sensors. To measure transfer length, five members were fabricated, which had a length of 3 m and a cross-section of $150{\times}150mm$. It was measured that the concrete compressive strength was 58MPa at pretensioning. Test results indicated that more precise and reliable measurement on the transfer length was attained with FBG sensors than conventional gauges attached on concrete surface. Through comparing the measured transfer length and predictions, applicability of several transfer length models in literature was investigated. This paper can be useful for relevant research field such as investigation on the bond mechanism of a seven-wire strand in concrete members.