• Title/Summary/Keyword: 감쇠 용량

Search Result 52, Processing Time 0.027 seconds

Study of Integrated Optimal Design of Smart Top-Story Isolation and Building Structures in Regions of Low-to-Moderate Seismicity (중약진지역 구조물과 스마트 최상층 면진시스템의 통합최적설계에 대한 연구)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.13-20
    • /
    • 2013
  • In order to reduce seismic responses of a structure, additional dampers and vibration control devices are generally considered. Usually, control performance of additional devices are investigated for optimal design without variation of characteristics of a structure. In this study, multi-objective integrated optimization of structure-smart control device is conducted and possibility of reduction of structural resources of a building structure with smart top-story isolation system has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions. The integrated optimal design method proposed in this study can provide various optimal designs that presents good control performance by appropriately reducing the amount of structural material and damping device.

Estimation of Structural Properties from the Measurements of Phase Velocity and Attenuation Coefficient in Trabecular Bone (해면질골에서 위상속도 및 감쇠계수 측정에 의한 구조적 특성 평가)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.661-667
    • /
    • 2009
  • Trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were used to investigate correlations of phase velocity and attenuation coefficient with structural properties in trabecular bone. Trabecular separation (Tb.Sp) of the 7 trabecular-bone-mimicking phantoms ranged from 300 to $900\;{\mu}m$ and volume fraction (VF) from 1.6% to 8.7%. Phase velocity and attenuation coefficient of the phantoms were measured by using a through-transmission method in water, with a matched pair of broadband unfocused transducers with a diameter of 12.7 mm and a center frequency of 1 MHz. Phase velocity and attenuation coefficient at 1 MHz decreased almost linearly with increasing Tb. Sp and increased almost linearly with increasing VF. The simple and multiple linear regression models with phase velocity and attenuation coefficient as independent vanables and Tb.Sp and VF as dependent variables demonstrated that the coefficients of determination for the prediction of VF were higher than those for the prediction of Tb.Sp. The results obtained in the trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were consistent with those in human trabecular bone suggesting that the structural properties can be estimated from the measurements of phase velocity and attenuation coefficient in trabecular bone.

On the Damping Effects of Helmet Safety with a Corrugation Damper using Taguchi's Optimization Design (다구찌 설계법을 이용한 주름댐퍼를 갖는 헬멧안전의 감쇠효과에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.34-40
    • /
    • 2008
  • Using the finite element method and Taguchi's design technique, the displacement in vertical direction, von Mises stress, and strain energy of the corrugation damper have been analyzed as functions of the extruded length and the thickness of the corrugation damper, and the upper and lower corner radii of the damper. The optimized profile design elements of a corrugation damper are very important for increasing a strain energy absorption capacity of a helmet structure, which is attacked by impulsive external forces. In this study, the optimized design data based on the Taguchi's method was computed as a corrugation damper length of L = 20 mm, a damper thickness of t = 2 mm, the upper corner radius of $R_1=4\;mm$, and the lower corner radius of $R_2=3\;mm$. The optimized design parameters of a corrugation damper indicated that the thickness and extruded length of a corrugation damper may affect to increase the strain energy, which absorbs the impact forces of the helmet.

  • PDF

Characterization and correction of bemding deformation in pizeoelectric ceramics displacement (길이변조용 압전소자의 휨 측정과 보정)

  • 김재완;남승희;한재원
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.300-304
    • /
    • 2001
  • We suggest a method to measure and correct bending deformation in piezoelectric ceramics displacement. The angle and direction of the bending deformation are measured by monitoring the position of a laser beam reflected on a mirror which is attached to the piezoelectric ceramics with the uncertainty of the angle measurement of $0.36\mu$rad. We divided the electrode of a piezoelectric ceramic into 3 parts and connected 3 capacitors to each electrode in order to apply different voltage to each electrode with one voltage supplier. The deformation was corrected by adjusting the capacitance of each capacitor and was reduced to 6.3%, comparing to the uncorrected case. By using this corrected piezoelectric ceramic to modulate the length of the ringdown cavity, the fluctuation of the decay time caused by the change in optic axis of the cavity was removed.emoved.

  • PDF

Multi-objective Integrated Optimization of Diagrid Structure-smart Control Device (다이어그리드 구조물-스마트 제어장치의 다목적 통합 최적화)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.69-77
    • /
    • 2013
  • When structural design of a tall building is conducted, reduction of wind-induced lateral displacement is one of the most important problem. For this purpose, additional dampers and vibration control devices are generally considered. In this process, control performance of additional devices are usually investigated for optimal design without variation of characteristics of a structure. In this study, multi-objective integrated optimization of structure-smart control device is conducted and possibility of reduction of structural resources of a tall building with additional smart damping device has been investigated. To this end, a 60-story diagrid building structure is used as an example structure and artificial wind loads are used for evaluation of wind-induced responses. An MR damper is added to the conventional TMD to develop a smart TMD. Because dynamic responses and the amount of structural material and additional smart damping devices are required to be reduced, a multi-objective genetic algorithm is employed in this study. After numerical simulation, various optimal designs that can satisfy control performance requirement can be obtained by appropriately reducing the amount of structural material and additional smart damping device.

Application of Smart Base Isolation System for Seismic Response Control of an Arch Structure (아치구조물의 지진응답제어를 위한 스마트 면진시스템의 적용)

  • Kang, Joo-Won;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2011
  • Base isolation system is widely used for reduction of dynamic responses of structures subjected to seismic load. Recently, research on a smart base isolation system that can effectively reduce dynamic responses of the isolated structure without accompanying increases in base drifts has been actively conducted. In this study, a smart base isolation system was applied to an arch structure subjected to seismic excitation and its control performance for reduction of seismic responses was evaluated. In order to make a smart base isolation system, 4kN MR dampers and low damping elastomeric bearings were used. Seismic response control performance of the proposed smart base isolation system was compared to that of the optimally designed lead-rubber bearing(LRB) isolation system. To this end, an artificial ground motion developed based on KBC2009 design response spectrum was used as a seismic excitation. Fuzzy control algorithm was used to control MR damper in the smart base isolation system and multi-objective genetic algorithm was employed to optimize the fuzzy controller. Based on numerical simulation results, it has been shown that the smart base isolation system can drastically reduce base drifts and seismic responses of the example arch structure in comparison with LRB isolation system.

Fuzzy Control of Smart TMD using Multi-Objective Genetic Algorithm (다목적 유전자알고리즘을 이용한 스마트 TMD의 퍼지제어)

  • Kang, Joo-Won;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.69-78
    • /
    • 2011
  • In this study, an optimization method using multi-objective genetic algorithm(MOGA) has been proposed to develop a fuzzy control algorithm that can effectively control a smart tuned mass damper(TMD). A 76-story benchmark building subjected to wind load was selected as an example structure. The smart TMD consists of 100kN MR damper and the natural period of the smart TMD was tuned to the first mode natural period of the example structure. Damping force of MR damper is controlled to reduce the wind-induced responses of the example structure by a fuzzy logic controller. Two input variables of the fuzzy logic controller are the acceleration of 75th floor and the displacement of the smart TMD and the output variable is the command voltage sent to MR damper. Multi-objective genetic algorithm(NSGA-II) was used for optimization of the fuzzy logic controller and the acceleration of 75th story and the displacement of the smart TMD were used as objective function. After optimization, a series of fuzzy logic controllers which could appropriately reduce both wind responses of the building and smart TMD were obtained. Based on numerical results, it has been shown that the control performance of the smart TMD is much better than that of the passive TMD and it is even better than that of the sample active TMD in some cases.

Study of Characteristics of Smart Base Isolation System with MR Damper for Regions of Low-to-Moderate Seismicity (중약진지역에 대한 MR 감쇠기로 구성된 스마트 면진시스템의 특성연구)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.325-336
    • /
    • 2012
  • Smart base isolation systems developed for structures in high seismic regions cannot be directly applied to structures in regions of low-to-moderate seismicity, such as Korea. Therefore, the problems that occur by applying the smart base isolation system for high seismic regions to the structures in regions of low-to-moderate seismicity have been investigated in this study. To this end, a five-story building is used as an example, and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes are simulated for ground motions in regions of high and low-to-moderate seismicity. Based on numerical simulation results, the MR damper capacity that can provide good control is quite different among regions of high and low-to-moderate seismicity. Moreover, it is noted that the properties of a smart base isolation system for the regions of low-to-moderate seismicity should be carefully designed because the base isolation effects of the smart base isolation system for high seismic regions deteriorate when it is applied to the structures in regions of low-to-moderate seismicity.

Modified Decentralized Bang-Bang Control Seismically Excited Structures Using MR Dampers (지진하중을 받는 구조물의 수정된 분산뱅뱅 제어기법을 이용한 MR Damper 제어)

  • Cho, Sang-Won;Kim, Byung-Wan;Kim, Woon-Hak;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.417-423
    • /
    • 2002
  • Magnetorheological(MR) 댐퍼는 적은 용량의 전력을 사용하고 반응속도가 빠른 장점 때문에 구조물의 내진제어에 적당하여, 근래에 주목받고 있는 새로운 장치이다. MR 댐퍼는 반능동 제어 장치로써, 능동 질량감쇠기와는 다른 특성을 갖는다. 즉 필요한 제어력을 제어신호로 직접 생성해 낼 수 없는 대신에 MR 댐퍼의 입력전원을 제어하여 간접적으로 제어한다. 따라서 MR 댐퍼의 반능동 제어장치로써의 특성을 고려하는 효과적인 제어기법이 요구된다. 그러므로 본 연구에서는 지진에 대한 구조물의 응답을 줄이기 위해서, MR댐퍼를 제어할 수 있는 반능동 제어기법을 Lyapunov 안정성 이론을 바탕으로 제안하고자 한다. 제안방법을 검증하기 위해, 전단형 MR 댐퍼를 1층과 2층에 설치한 수치예제를 수행하였다.

  • PDF

무선 메쉬 네트워크 구축 및 보안 기술 현황

  • Lee, Yong;Lee, Goo-Yeon
    • Review of KIISC
    • /
    • v.18 no.2
    • /
    • pp.40-48
    • /
    • 2008
  • 미래의 광대역 무선망은 고주파수의 대역을 사용하여 신호의 감쇠가 높고, 높은 multi-path fading효과를 가지므로 전력제어가 필요하고 사용자에게 넓은 대역폭을 제공할 것으로 예측한다. 이를 위해 셀의 크기가 줄게 되고 BS의 수가 증가하여 네트워크 설치비용도 증가하게 될 것이다. 무선 메쉬 네트워크는 이런 문제를 해결하여 망구축과 운영을 쉽게 하고 영역 확장과 용량 확장을 유연하게 하며 저비용의 무선 bakhaul로 높은 신뢰성을 제공하는 특성을 가진다. 무선 메쉬 네트워크는 노드와 노드간의 무선 멀티-홉 통신을 이용하여 끊김 없는 연속적인 연결을 제공하는 네트워크 기술이다. 이 기술은 메쉬 라우터와 메쉬 클라이언트라는 노드로 구성되며 각 노드는 라우터인 동시에 호스트로 동작할 수 있다 앞서 언급한 바와 같이 자가 구성, 자가 복구의 능력을 가지고 저 비용으로 신뢰성 있는 네트워크 구축을 제공하기 때문에 무선랜이나 WiMAX, WPAN 등에서 채택되고 있다. 이 논문에서는 메쉬 네트워크의 구조와 특징을 자세히 설명하고 IEEE 802.11s와 IEEE 802.16j에서 진행되는 무선 메쉬 네트워크 관련 표준화를 살펴본 후 관련업체에서의 메쉬 네트워크 관련 개발 현황과 실제 구축 현황을 설명하고자 한다. 또한 무선 메쉬 네트워크에서 발생하는 여러 가지 보안 문제와 적용기술들을 짚어 보고자 한다.