• Title/Summary/Keyword: 감쇄 파라미터

Search Result 26, Processing Time 0.022 seconds

Optimal Time Scheduling Algorithm for Decoupled RF Energy Harvesting Networks (비결합 무선 에너지 하비스팅 네트워크를 위한 최적 시간 스케줄링 알고리즘)

  • Jung, Jun Hee;Hwang, Yu Min;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.2
    • /
    • pp.55-59
    • /
    • 2016
  • Conventional RF energy harvesting systems can harvest energy and decode information from same source as an Hybirid-AP (H-AP). However, harvesting efficiency is seriously dependent on distance between users and H-AP. Therefore, in this paper, we proposed a transmission model for RF harvesting consisting of information and power source separately called Decoupled RF Energy harvesting networks. Main purpose of this paper is to maximize energy efficiency under various constraints of transmit power from H-AP and power beacon (PB), minimum quality of service and quality of harvested power of each users. To measure proposed model's performance, we proposed optimal time scheduling algorithms for energy efficiency (EE) maximization using Lagrangian dual decomposition theory that locally maximizes the EE by obtaining suboptimal values of three arguments : transmit power of H-AP, transmit power of PB, frame splitting factor. Experiment results show that the proposed energy-efficient algorithms converge within a few iterations with its optimality and greatly improve the EE compared to that of baseline schemes.

Predicting Migration of a Heavy Metal in a Sandy Soil Using Time Domain Reflectometry (TDR을 이용한 사질토양에서의 중금속 이동 추정)

  • Dong-Ju Kim;Doo-Sung Baek;Min-Soo Park
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Recently, transport parameters of conservative solutes such as KCl in a porous medium have been successfully determined using time domain reflectometry (TDR) . This study was initiated to Investigate the applicability of TDR technique to monitoring the fate of a heavy metal ion in a sandy soil and the distribution of its concentration along travel distance with time. A column test was conducted in a laboratory that consists of monitoring both resident and flux concentrations of $ZnCl_2$in a sandy soil under a breakthrough condition. A tracer of $ZnCl_2$(10 g/L) was injected onto the top surface of the sample as pulse type as soon as a steady-state condition was achieved. Time-series measurements of resistance and electrical conductivity were performed at 10 cm and 20 cm of distances from the inlet boundary by horizontal-positioning of parallel TDR metallic rods and using an EC-meter for the effluent exiting the bottom boundary respectively. In addition. Zn ions of the effluent were analyzed by ICP-AES. Since the mode and position of concentration detected by TDR and effluent were different, comparison between ICP analysis and TDR-detected concentration was made by predicting flux concentration using CDE model accommodating a decay constant with the transport parameters obtained from the resident concentrations. The experimental results showed that the resident concentration resulted in earlier and higher peak than the flux concentration obtained by EC-meter, implying the homogeneity of the packed sandy soil. A close agreement was found between the predicted from the transport parameters obtained by TDR and the measured $ZnCl_2$concentration. This indicates that TDR technique can also be applied to monitoring heavy metal concentrations in the soil once that a decay constant is obtained for a given soil.

  • PDF

A Reference Spur Suppressed PLL with Two-Symmetrical Loops (기준 신호 스퍼의 크기를 줄인 두 개의 대칭 루프를 가진 위상고정루프)

  • Choi, Hyun-Woo;Choi, Young-Shig
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.5
    • /
    • pp.99-105
    • /
    • 2014
  • A reference spur suppressed PLL with two-symmetrical loops without changing the bandwidth which is optimized to suppress phase noise and reduce locking time has been designed. The principle of suppressing a reference signal spur is to stabilize the input voltage of voltage controlled oscillator (VCO). The proposed PLL consists of a phase-frequency detector(PFD) which has two outputs, two charge pumps(CP), two loop filters(LF), a divider and a VCO which has two inputs. Simulation results with $0.18{\mu}m$ CMOS process show that the reference spur is approximately suppressed to 1/2 of the reference spur in a conventional PLL. Even though there is a 5% process variation in the magnitude of R and C, the simulation result shows that the reference spur is still suppressed to 1/2 of the reference spur in a conventional PLL. The power consumption is 6.3mW at the power supply of 1.8V.

The Numerical Analysis of the Aeroacoustic Characteristics for the Coaxial Rotor in Hovering Condition (동축반전 로터의 제자리 비행 공력소음 특성에 관한 수치 해석적 연구)

  • So, Seo-Bin;Lee, Kyung-Tae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.8
    • /
    • pp.699-708
    • /
    • 2021
  • In this paper, the aerodynamic and aeroacoustic characteristics that vary depending on the rotation axial distance between the upper and lower rotor, which is one of the design parameters of the coaxial rotor, is analyzed in the hovering condition using the computational fluid dynamics. Aerodynamic analysis using the Reynolds Averaged Navier Stokes equation and the aeroacoustic analysis using the Ffowcs Williams ans Hawkings equation is performed and the results were compared. The upper and lower rotor of the coaxial rotor have different phase angle which changes periodically by rotation and have unsteady characteristics. As the distance between the upper and lower rotors increased, the aerodynamic efficiency of the thrust and the torque was increased as the flow interaction decreased. In the aeroacoustic viewpoint, the noise characteristics radiated in the direction of the rotational plane showed little effect by axis spacing. In the vertical downward direction of the axis increased, the SPL maintains its size as the frequency increases, which affects the increase in the OASPL. As the axial distance of the coaxial rotor increased, the noise characteristics of a coaxial rotor were similar with the single rotor and the SPL decreased significantly.

Performance Analysis of Multi-Carrier CDMA Trellis Coded 16 QAM System with Near/Far Effect in Frequency Selective Multipath Fading Channel (주파수 선택성 다중경로 페이딩 채널에서 Near/Far 영향을 받는 Multi-Carrier CDMA Trellis Coded 16 QAM 시스템의 성능해석)

  • 노재성;강희조;김춘길;김언곤;조성준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3A
    • /
    • pp.352-361
    • /
    • 2000
  • The performance of a multi-carrier CDMA system is analyzed considering frequency selective multipath fading and Near/Far effects. The number of multicarrier, multiuser, and arms of RAKE receiver, and the decay ratio of frequency selective multipath fading are used as a parameter for the performance analysis. More over, the distribution and the strength of multiuser interference are also considered. To evaluate the Near/Far effects in a multi-carrier CDMA system, three distribution models are assumed. In the first model, interference to carrier Ratio, I/C, ranges from -4 dB to 4dB, and at each 2 dB interval, 20 % of multiuser is assumed to be uniformly distributed. In the second one, I/C ranges from -2 dB to 2 dB, and 33.3% of multiuser is assumed to be equally dispersed at each 2dB interval. The third model is 0 dB of I/C, that is, with perfect power control, multiuser are assumed to be evenly located. In this paper, multi-carrier CDMA system adoption RAKE receiver is proposed to mitigate the frequency selective multipath fading. From the results, the third model(i.e. perfect power control) shows the best performance, and the narrower range of I/C causes the less effects to the desired signal, which reads to the better performance.

  • PDF

Channel characteristics of multi-path power line using a contactless inductive coupling unit (비접촉식 유도성 결합기를 이용한 다중경로 전력선 채널 특성)

  • Kim, Hyun-Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.799-804
    • /
    • 2016
  • Broadband powerline communication (BPLC) uses distribution lines as a medium for achieving effective bidirectional data communication along with electric current flow. As the material characteristics of power lines are not good at the communication channel, the development of power line communication (PLC) systems for internet, voice, and data services requires measurement-based models of the transfer characteristics of the network suitable for performance analysis by simulation. In this paper, an analytic model describing a complex transfer function is presented to obtain the attenuation and path parameters for a multipath power line model. The calculated results demonstrated frequency-selective fading in multipath channels and signal attenuation with frequency, and were in good agreement with the experimental results. Inductive coupling units are used as couplers for coupling the signal to the power line to avoid physical connections to the distribution line. The inductance of the ferrite core, which depends on the frequency, determines the cut-off frequency of the inductive coupler. Coupling loss can be minimized by increasing the number of windings around the coupler. Coupling efficiency was improved by more than 6 dB with three windings compared to the results obtained with one winding.