• Title/Summary/Keyword: 감쇄 보정

Search Result 49, Processing Time 0.023 seconds

A Study on Direction Finding Technique for Array with Faulty Elements (결함소자를 갖는 어레이를 위한 방향 탐지 기법에 관한 연구)

  • Kim, Ki-Man;Youn, Dae-Hee;Cha, Il-Whan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.71-75
    • /
    • 1997
  • In this paper, some problems that occur from faulty elements in a direction finding system composed of the linear array are studied and the method which improves the performance is proposed. The fault element means the sensor that has no output or highly reduced gain than other normal sensors. In the case of the presence of faulty elements, the performance of the conventional the spatial spectrum subject to a constraint. The corrected spatial spectrum is obtained by this vector. The computer simulations have been performed to study the performance of the proposed method. We have compared the proposed method with the subaperture processing method of one of the previous works.

  • PDF

System gamma and color temperature correction in low gray level of LCD device by using PLCC model (PLCC모델을 이용한 시스템감마와 저계조의 색온도 보정방법)

  • Kim, Young-Kook;Dhamija, Rohit;Jeon, Byeung-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.262-263
    • /
    • 2008
  • LCD 디바이스는 그 동작원리와 전기-광학적 특성에 의해 CRT와는 다른 감마곡선 특성을 갖고 있다. 대부분의 LCD디스플레이 디바이스들의 감마곡선은 CRT와는 달리 일관성을 갖지 않을 뿐 더러 흑백계조입력을 기준으로 하는 감마보정을 위해 RED, GREEN, BLUE 입력값을 세부적으로 조정할 때 각 계조입력에 대한 상관색온도가 일정한 값을 갖지 않아 LCD의 특성에 대한 모델링과 보정에 어려움이 있다. 또한, 애플사의 맥머신 그리고 실리콘 그래픽스사의 시스템과 같이 소정의 감마값을 전제로 해당 시스템의 내부참조테이블(internal look-up table)이 설계되어 각기 다른 시스템감마를 가지는 장치들에 의해 인코딩되어진 영상출력신호의 경우, 동일한 시스템을 갖추거나 시스템감마에 대한 역감마특성을 가진 디스플레이장치가 아닌 환경에서는 원본영상에 대한 왜곡은 더욱 커질 수 있다. 특히, 낮은 흑백계조입력에서의 색온도의 경우, 파장에 따라 서로 다른 감쇄성능을 가진 일반적인 컬러필터의 특성에 의한 누설광(light leakage)에 의해 결정되며, 이로 인해 색온도가 특정한 객을 띄는 현상이 발생한다. 본 논문에서는 LCD디스플레이의 감마곡선을 여러 가지 시스템감마에 대응할 수 있는 감마곡선예 일치시키고, 계조선형성을 동시에 개선하기 위하여 입력 디지털값과 삼자극치간 관계를 나타내는 여러 가지 컬러모델링 방법 중에서 PLCC(Piecewise Linear Interpolation assuming Constant Chromaticity coordinates)모델을 적용하고, 목표로 하는 감마곡선과 색온도를 만족하기 위한 새로운 입력값을 구한 후 이를 컬러참조테이블(color look-up table)예 적용하는 방법과 저계조에서의 색온도를 목표색온도에 근접시키는 방법을 제안한다.

  • PDF

Egomotion Compensation of a Humanoid Robot by Using Stereo Vision (스테레오 비전을 이용한 휴머노이드 로봇의 자기 움직임 보정)

  • Kang, Tae-Koo;Park, Gwi-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.257-258
    • /
    • 2008
  • 지능형 로봇에서 환경인식과 이러한 환경에 따른 행동 결정 능력은 로봇이 필수적으로 갖추어야 할 기능이다. 특히 상체의 움직임이 많은 휴머노이드 로봇에서 비전기반의 높은 환경에 대한 인식 기능을 위해서는 전처리 단계로 로봇 자체의 움직임을 감쇄 시켜주는 기능이 필수적이다. 본 논문에서는 Gaussian 모델과 Wavelet을 사용하여 추적하고자 하는 영역을 추출하고 PCA와 FNCC를 이용하여 움직임을 상쇄시키는 방법을 제안한다. 본 방법은 기존의 픽셀 단위로 움직임을 분석하는 방법에 비하여 간단하면서도 우수한 성능을 보인다. 본 시스템을 제작한 로봇에 적용한 결과 보다 높은 인식 성능을 얻을 수 있었다.

  • PDF

양전자 방출 단층기

  • 나종범;조장희;노용만
    • 전기의세계
    • /
    • v.38 no.8
    • /
    • pp.26-31
    • /
    • 1989
  • PET는 다른 nuclear imaging system(SPECT등)과는 달리 기계적 collimator가 필요없이 전자적 collimation을 할 수 있고 이런 collimation역할로 인하여 SPECT보다 감도(sensitivity)가 좋고 또한 전체 영상영역에 걸쳐 해상도와 감도가 균일하며 감쇄상수의 보정이 쉽다. 기존 X선 CT나 NMR-CT에 비해 해상도와 신호대 잡음비가 떨어짐에도 불구하고 PET 시스템 독특한 장점은 영상 자체가 단순한 영상을 재현하는 것이 아니라 인체내의 생태학적 또는 생리학적인 변화에 대한 정량적 분석이 가능하다는데 있다. 즉, $^{11}$ C, $^{13}$N, $^{15}$ O, $^{18}$ F와 같은 물질은 인체내에 생리적현상과 매우 밀접한 관계를 가지고 있어 이들 물질의 분포나 변화를 제공하는 것은 다른 의료 영상기기와 뚜렷이 구별되는 점이라 할 수 있다. 따라서 앞으로 분해 능력이 2-3mm의 PET시스템의 개발은 임상은 물론 의료연구용으로 매우 유용할 것이며 종래의 NMR과 X선 CT 와는 다른 보완적인 정보를 제공하는 영상시스템으로써 의료산업계의 발전에 크게 기여를 할 것이라고 본다.

  • PDF

Design of a microstripe line ceramic dielectric filter (마이크로스트립라인 세라믹 유전체필터 설계)

  • Ko, Hee-Youl;Kim, Chung-Hoi;Kang, Byung-Don;Koo, Bon-Keup
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.712-715
    • /
    • 2012
  • 본 논문에서는 EM 시뮬레이터를 이용하여 LTE2300 대역의 마이크로스트립 라인 대역여파기를 설계하고 시편을 제작하였다. 중심주파수 2300MHz, 대역폭 350MHz, 삽입손실 1.5dB, 감쇄는 1930MHz와 2690MHz에서 15dB 이상, 1000MHz에서 60dB 이상으로 설계하였다. 또한 반사손실은 15dB로 설계하였다. 구현은 유전율 9.8인 알루미나 유전체에서 하였으며, 전송선로와 접지는 silver paste를 사용하였다. EM 시뮬레이션을 통해 얻은 결과값과 이를 통해 실제 제작된 시편의 보정값을 얻어 data base화 하였으며, 좋은 재현성을 얻을 수 있음을 확인하였다. 특히 일반적으로 마이크로스트립 라인 필터의 제작에 적용되는 에칭 또는 포토리소그라피 대신 레이저를 이용하여 패턴을 구현하였으며, 이 또한 우수한 특성과 재현성을 보여주었다.

  • PDF

비상 베타선량계의 에너지에 따른 피부 선량평가 알고리즘 개발

  • 조천형;이원근;김종수;윤석철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.63-68
    • /
    • 1996
  • 열형광 선량계(TLD)를 사용한 피부 선량평가는 베타선의 에너지를 구분함으로 정확히 평가된다. 이는 차폐체에 의한 감쇄효과를 이용하는 방법으로 본 논문에서는 7개의 두께가 다른 알루미늄 차폐체를 사용하였고, TLD로는 미국 Teledyne Isotopes사의 LiF$_{7}$ 선량계를 채택하였다. 비상 베타 선량계의 베타선에 대한 특성실험을 위해 한국 원자력연구소가 확보 하고 있는 PTB 표준선원인 $^{90}$ Sr/ $^{90}$ Y (E$_{max}$=2.27MeV, E$_{avg}$=0.8MeV), $^{204}$Tl(E$_{max}$=0.76MeV, E$_{avg}$=0.26MeV), $^{147}$ Pm (E$_{max}$= 0.225MeV, E$_{avg}$=0.06MeV)에 대한 조사를 하였다. 이런 결과로 비상 베타 선량계의 표준 베타선원에 대한 보정계수와 소자별 반응비를 구할 수 있었고, 이것을 이용하여 미지의 베타선원에 대하여 정확한 선량평가를 하기위한 알고리즘을 개발하였다.

  • PDF

감쇄위상변위마스크를 사용하는 메탈레이어 리토그라피공정의 오버레이 보정

  • 이우희;이준하;이흥주
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.05a
    • /
    • pp.159-162
    • /
    • 2004
  • Problems of overlap errors and sidelobe printing by the design rule reduction in the lithography process using attenuated phase-shifting masks(attPSM) have been serious. Overlap errors and sidelobes can be simultaneously solved by the rule-based correction using scattering bars with the rules extracted from test patterns. Process parameters affecting the attPSM lithography simulation have been determined by the fitting method to the process data. Overlap errors have been solved applying the correction rules to the metal patterns overlapped with contact/via. Moreover, the optimal insertion rule of the scattering bars has made it possible to suppress the sidelobes and to get additional pattern fidelity at the same time.

  • PDF

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

Modal Analysis of the Vector Triggering Random Decrement Function (벡터 트리거조건에 의한 Random Decrement 함수의 모우드 해석)

  • 정범석;이외득
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.209-218
    • /
    • 2002
  • The Vector Random Decrement technique has been developed as an efficient method for transforming ambient responses into free decays of linear structures. It is shown that the VRD functions nay contain as much information about the modes as the really measured free decay responses. In this paper, the theory of the VRD technique is extended by applying the concept of the mode shape ratio into the Ibrahim Time Domain modal parameter identification algorithm. The VRD function is not shifted in the correction procedures for constant time shifts of the proposed VRD technique. Thus, a number of points equal to the largest of the time shifts used in the vector triggering condition are not deleted. In the VRD functions, any influence of the input to the system is averaged out. The proposed technique is compared with the traditional VRD technique by assessment of the modal parameters. The applicability of the VRD technique has been justified through a simulation study and a study of the response of a laboratory beam model subject to ambient loads.

The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters (PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화)

  • Shin, Gyoo-Seul;Dong, Kyeong-Rae
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2007
  • Purpose : There is difference between PET and PET/CT method on their transmission image for attenuation correction. The CT image is used for attenuation correction on PET/CT and the parameters of CT may be affected on PET image. We performed the phantom study to evaluate whether the change of CT parameters(kilovolts peak and milliampere) affect standardized uptake value(SUV) on PET image. Material and Method: The data spectrum lung phantom containing diluted [18F]fluorodeoxyglucose ([18F]FDG) solution(1.909 mCi for phantom 1, $913\;{\mu}Ci$ for phantom 2) was used. The CT images of phantom were acquired with varying parameters (80, 100, 120, 140 for kVp, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 for mA). The PET images were reconstructed with the each CT images and SUVs were compared. Result : The SUVs of phantom 1 reconstructed with each 80, 100, 120 and 140 kVp showed $12.26{\pm}0.009$, $12.27{\pm}0.005$, $12.27{\pm}0.006$ and $12.27{\pm}0.009$, respectively. The SUVs of phantom 2 revealed $4.52{\pm}0.043$, $4.53{\pm}0.004$, $4.52{\pm}0.007$ and $4.52{\pm}0.005$ with elevation of voltage. There was no statistically significant difference of SUVs between groups based on various kVp. Also SUVs of phantom 1 and 2 showed no significant change with elevation of milliampere in CT parameter. Conclusion : The parameters of CT did not significantly affect SUV on PET image in our study. Therefore we can apply various parameters of CT appropriated for clinical conditions without significant change of SUV on PET CT image.

  • PDF