• Title/Summary/Keyword: 감마방사선

Search Result 993, Processing Time 0.022 seconds

Studies on the Preservation of Korean Rice by Gamma-irradiation(I) (감마선 조사(照射)에 의한 쌀 저장에 관한 연구(제1보))

  • Kim,, Hyong-Soo;Choi, Young-Rack
    • Korean Journal of Food Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.51-61
    • /
    • 1969
  • In order to eliminate the considerable loss of rice by insects, to protect the human body from toxin excreted by some microbes, and to promote the storage efficiency of rice by employing the irradiation, the following experiments were carried out. Two varieties of rice, Paldal and Nongkwang polished and unpolished by the conventional methods and were packaged in polyethylene bags. After irradiating to the doses of 6-400 Krad of gamma-radiation from a $Co-^{60}$ source the samples were stored at the room temperature $20^{\circ}C$ for 8 months. The effects of radiation in terms of the removal of insects and microbes and the changes of chemical components (such as moisture, amylose, free sugar, and rancidity) were determined monthly from march to October during the storage. 1) Infestation of insects was greatly influeneed by the packaging materials used. There was no infestation in rice being packaged in a polyethylene bag, while as the rice packaged in a straw sack was infested in two months of the storage. 2) Some yeast and molds survived 400 K rad of radiation. Sterilizing dose to inhibit reproduction and growth of microbes was presumed to be higher than 400 K rad. Yeast mainly were found on the surface of rice, but mold were embeded into rice kernels by mycelium. 3) Changes of moisture contents during storage was not affected by radiation but was by humidity of the storage room. 4) Amylose content in starch increased with increasing dose of radiation and with the length of storage time, indicating possible depolymerization of starch molecules. 5) Free reducing sugar content was not affected by radiation and decreased with storage time. 6) Rancidity also increased with does and storage time.

  • PDF

Detection of Radiation Induced Markers in Oranges Imported from the United States of America (미국산 오렌지의 Radiation Induced Marker 검색)

  • 조덕조;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • Radiation induced markers were investigated for the detection of irradiated oranges imported from America. In the DNA comet assay, the non-irradiated and irradiated samples showed the comets with long tails in both seed and flesh. Though this tendency was maintained for 6 weeks, identification of non-irradiated or irradiated samples was impossible. In the thermoluminescence (TL) measurement, the non-irradiated samples revealed a glow curve with low intensity at about 28$0^{\circ}C$, while the irradiated samples showed with higher intensity at around 18$0^{\circ}C$. There were no remarkable changes in detection properties for 6 weeks after irradiation. The TL ratio of area for TL$_1$ glow curve to TL$_2$ was below 0.1 for the non-irradiated samples and 0.5 or more for the irradiated ones during storage. In the electron spin resonance (RSR) measurement, irradiated oranges showed an unspecific central signal in all parts (seed, flesh and peel), so the detection for radiation treatment of oranges was impossible. Based on the results, DNA comet assay and ESR were not useful for the detection, but TL was appropriate to search radiation induced markers of oranges during storage period. The detectable period during storage is confirmed by sensory evaluation.

Detection Characteristics of TL, ESR and DNA Comet for Irradiated Peanuts by Origins (TL, ESR및 DNA Comet분석에 의한 원산지별 땅콩의 방사선 조사 검지 특성)

  • 이은영;정재영;조덕조;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.6
    • /
    • pp.1076-1081
    • /
    • 2001
  • Gamma-irradiated peanuts, Korean and Chinese origins, were investigated on detection properties by thermoluminescence (TL), electron spin resonance (ESR), and DNA comet assay (single cell gel electrophoresis). TL measurement showed that the non-irradiated sample revealed a glow curve with low intensity at about 25$0^{\circ}C$, while the irradiated samples showed higher intensity around at 18$0^{\circ}C$. TL ratio (TL$_1$/TL$_2$) of area for TL$_1$ glow curve to TL$_2$ was below 0.05 for the non-irradiated sample and 0.2 or more for the irradiated ones, thus identifying each other. ESR spectroscopy for the irradiated peanuts using outer skin showed negligible signals induced by irradiation, indicating ESR is little applicable to the detection of irradiated peanuts. In DNA comet assay, the non-sample had no or very short tails, whereas the irradiated samples revealed the cells with long tails. Significance in the increase of their lengths depending on irradiation dose (r=0.761/Korean, r=0.768/Chinese) was also found. There was no remarkable difference in detection properties by origins of samples in all determinations, It is concluded that TL analysis or DNA comet assay is suitable for detection of irradiated peanuts and a combined method is recommendable for enhancing the reliability of detection results.

  • PDF

Qualitative Evaluation of 2D Dosimetry System for Helical Tomotherapy (2차원 토모테라피 선량측정시스템의 정성적 평가)

  • Ma, Sun Young;Jeung, Tae Sig;Shim, Jang Bo;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.193-198
    • /
    • 2014
  • The purpose of this study is to see the feasibility of the newly developed 2D dosimetry system using phosphor screen for helical tomotherapy. The cylindrical water phantom was fabricated with phosphor screen to emit the visible light during irradiation. There are three types of virtual target, one is one spot target, another is C-shaped target, and the other is multiple targets. Each target was planned to be treated at 10 Gy by treatment planning system (TPS) of tomotherapy. The cylindrical phantom was placed on the tomotherapy table and irradiated as calculations of the TPS. Every frame which acquired by CCD camera was integrated and the doses were calculated in pixel by pixel. The dose distributions from the fluorescent images were compared with the calculated dose distribution from the TPS. The discrepancies were evaluated as gamma index for each treatment. The curve for dose rate versus pixel value was not saturated until 900 MU/min. The 2D dosimetry using the phosphor screen and the CCD camera is respected to be useful to verify the dose distribution of the tomotherapy if the linearity correction of the phosphor screen improved.

Development of Effective ${\gamma}$-ray and ${\beta}$-ray Detection Methods For Low-Level Radioactive Wastes (극저준위 방사성 폐기물을 위한 효율적인 ${\gamma}$-선 및 ${\beta}$-선 측정 방법 개발)

  • Kwak, Sung-Woo;Yeom, Yu-Sun;Kim, Ho-Kyung;Cho, Gyu-Seong;Park, Joo-Wan;Kim, Chang-Lak;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.393-398
    • /
    • 2001
  • The non-combustible RI wastes disposed of in hospital every year emit ${\gamma}$-ray or ${\beta}$-ray but their activities are very low to the extent of background. Development of more simple methods is needed because the conventional detection methods are so ineffective and complex. In this study, to solve this problem, detection method using efficiency curve for ${\gamma}$-ray emitting radioactive wastes measurement is proposed and experimental detection efficiency equation is also determined through HPGe's standard specimen measurement. For ${\beta}$-emitting radioisotopes detection, new measurement method using detection efficiency estimated by Monte Carlo simulation and SBD measurements is also proposed. According to the results of this paper, the unknown activity of low-level radioactive wastes without LSC requiring the preparation of standard sample and measurement for standard source detection efficiency could be determined efficiently and simply about ${\pm}17%$ in errors by using the theoretical detection efficiency and the SBD measurement result.

  • PDF

Effects of low dose gamma irradiation on the germination and physiological activity of old red pepper ( Capsicum annuum L.) seed (묵은 고추종자의 발아와 생리활성에 미치는 저선량 방사선조사 효과)

  • Kim, Jae-Sung;Back, Myung-Hwa;Lee, Hae-Youn;Lee, Young-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.409-415
    • /
    • 2001
  • To observe the stimulating effects of low dose gamma radiation on the germination and physiological activity of germinating seeds of old red pepper (Capsicum annuum L. cv Jokwang and cv. Hongkwang), seeds were irradiated at the dose of $2{\sim}50 Gy$. The germination rate of irradiation group was higher than that of the control. Especially it was highest at the early stage of induction. The germination rate at 7 days after sowing in Jokwang and Hongkwang cultivar was high as 74% and 11% at 4 Gy and 8 Gy irradiation group, respectively. The seedling height of Jokwang cultivar was noticeably high at 4 Gy irradiation group and that of Hongkwang cultivar at 8 Gy irradiation group. The protein contents of seedlings from seeds irradiated with low dose gamma radiation of Jokwang cultivar increased at the late stage of induction and that of Hongkwang cultivar at the early stage of induction. Catalase and peroxidase activities of seedlings from seeds irradiated with low dose gamma radiation of Jokwang cultivar increased at 4 Gy irradiation group and that of Hongkwang cultivar at 8 Gy irradiation group.

  • PDF

Irradiation Preservation of Korean Fishes -Part. II Radurization of Freshwater Species- (방사선(放射線) 조사(照射)에 의한 한국산(韓國産) 어류(魚類)의 품질보존(品質保存)에 관(關)한 연구(硏究) -제2보(第2報) 민물어종(魚種)(잉어 및 무지게 송어)의 방사선조사(放射線照射)-)

  • Chung, Jong-Rak;Kim, Su-Il;Lee, Min-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.161-171
    • /
    • 1976
  • The meat samples of carp (Cyprinus carpio, Linne) and rainbow trout (Salmo gairdnerii) packaged in aluminum pouches with polyethylene adjuvant were exposed to gamma radiation of doses up to 1.5 Mrad for the purpose of determining optimum dose range required to bring about a significant storage-life extension at refrigerated temperatures. The maximum permissible dose for carp was determined to be 1.5 Mrad and that for rainbow trout 0.2 Mrad, while the optimum dose was 0.25 Mard and 0.05 Mrad, respectively. By irradiating them at each optimum dose, the practical storage-life of carp could be extended from one week to five at both $0^{\circ}\;and\;5^{\circ}C$ and that of rainbow trout from one week to 3-4 weeks at $0^{\circ}C$ and from 3 days to 14 days at $5^{\circ}C$. The carp meat suffered from extensive drip loss during the post-irradiation storage and it could be reduced effectively by dipping the samples into 10% polyphosphate solution prior to the radurization treatment. The rainbow trout was highly radiosensitive, while carp appeard to one of promising species to be radurization treated for the purpose of extending storage-life at refrigerated temperatures.

  • PDF

A Study on the Radiation Source Effect to the Radiation Shielding Analysis for a Spent-Fuel Cask Design with Burnup-Credit (연소도이득효과를 적용한 사용후핵연료 수송용기의 방사선원별 차폐영향 분석)

  • Kim, Kyung-O;Kim, Soon-Young;Ko, Jae-Hoon;Lee, Gang-Ug;Kim, Tae-Man;Yoon, Jeong-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.73-80
    • /
    • 2011
  • The radiation shielding analysis for a Burnup-credit (BUC) cask designed under the management of Korea Radioactive Waste Management Corporation (KRMC) was performed to examine the contribution of each radiation source affecting dose rate distribution around the cask. Various radiation sources, which contain neutron and gamma-ray sources placed in active fuel region and the activation source, and imaginary nuclear fuel were all considered in the MCNP calculation model to realistically simulate the actual situations. It was found that the maximum external and surface dose rates of the spent fuel cask were satisfied with the domestic standards both in normal and accident conditions. In normal condition, the radiation dose rate distribution around the cask was mainly influenced by activation source ($^{60}Co$ radioisotope); in another case, the neutron emitted in active fuel region contributed about 90% to external dose rate at 1m distance from side surface of the cask. Besides, the contribution level of activation source was dramatically increased to the dose rates in top and bottom regions of the cask. From this study, it was recognized that the detailed investigation on the radiation sources should be performed conservatively and accurately in the process of radiation shielding analysis for a BUC cask.

Design of Two Layer Depth-encoding Detector Module with SiPM for PET (SiPM을 사용한 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 모듈 설계)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.319-324
    • /
    • 2019
  • A depth-encoding detector module with silicon photomultipliers(SiPMs) using two layers of scintillation crystal array was designed, and the position measurement capability was verified using DETECT2000. The depth of interaction of the crystal pixels with the gamma rays was tracked through the image acquired with the combination of surface treatment of the crystal pixels and reflectors. The bottom layer was treated as a reflector except for the optically coupled surfaces, and the crystals of top layer were optically coupled each other except for the outer surfaces so that the light sharing was made easier than the bottom layer. Flood images were obtained through the combination of specular reflectors and random reflectors, grounded and polished surfaces of crystal pixels, and the positions at which layer images were generated were measured and analyzed. The images were reconstructed using the Anger algorithm, whose the SiPM signals were reduced as the 16-channels to 4-channels. In the combination of the grounded surface and all reflectors, the depth positions were discriminated into two layers, whereas it was impossible to separate the two layers in the all polished surface combinations. Therefore, using the combination of grounded surface crystal pixels and reflectors could improve the spatial resolution at the outside of the field of view by measuring the depth position in preclinical positron emission tomography.

Design of a Depth Encoding Detector using Light Guides with Different Reflector Patterns for Each Layer (각 층별 반사체 패턴이 서로 다른 광가이드를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.31-36
    • /
    • 2023
  • Among imaging and treatment devices for small animals, positron emission tomography(PET) causes a change in spatial resolution within a field of view. This is a phenomenon caused by using a small gantry and a thin and long scintillation pixel, and detectors that measure the interaction depth are being developed and researched to solve this problem. In this study, a detector that measures the interaction depth was designed using several scintillator blocks and light guides with different reflector patterns. The scintillator block composed of 4 × 4 arrays of 3 mm × 3 mm × 5 mm scintillation pixels formed four layers, and a light guide was inserted in each layer to configure the entire detector. In order to check whether the interaction depth was measured, a gamma ray interaction was generated at the center of all scintillation pixels to acquire data and then reconstructed into a flood image. The reflector patterns of the light guides inserted between the layers were all different, so the positions of the scintillation pixels for each layer were formed in different locations. It is considered that even spatial resolution can be achieved over all regions of the field of view if all positions of the scintillation pixels thus formed are separated and used for image reconstruction.