• Title/Summary/Keyword: 감도비

Search Result 440, Processing Time 0.028 seconds

Minimization of power penalty using chirp parameter for 2.5 Gbps, 8 channel, 400 km optical link system with dispersion and SPM (분산과 SPM이 존재하는 2.5Gbps, 8채널 400km 광 링크 시스템에서의 처핑 계수를 이용한 수신 감도 저하의 최소화)

  • 이병호;박영일;김익상;채창준;이병호
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.250-253
    • /
    • 1997
  • The effect of dispersion in optical transmission system changes according to chirp and SPM. Chirp depends on the modulation condition of an external modulator. SPM is proportional to signal power. In this paper, we analyzed the pulse broadening due to SPM and chirp in the system with dispersion by using Split Step Fourier Method and calculated the optimum chirp parameter for 400 km transmission system. Experimental results are presented also.

  • PDF

On the Calibration of Impact Hammer Sensitivity (충격 해머의 감도보정)

  • 한상보
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.71-74
    • /
    • 1991
  • 구조물의 진동특성을 파악하기 위한 실험적 모우드 해석법에서 기진력을 제 공하는 한 방법으로 힘 측정기가 부착된 해머를 이용한 충격시험기법이 널 리 사용되고 있다. 충격해머 시험의 유용성은 기진력의 에너지가 정현파 기 진력의 경우처럼 특정 주파수대에 산재해 있는 것이 아니라 가용 주파수 영 역내에 연속적으로 분포해 있다는 점이며 이러한 충격력은 가용 주파수 범 위내에 있는 모든 고유진동형을 여가시킬 수 있다는 장점이 있다. 충격헤머 가 가지고 있는 동적특성은 구조물을 가진시키는 선형충격량의 크기를 결정 하며, 이는 다시 충격력의 크기와 가용 주파수 범위를 결정하게 된다. 일반 적으로 가진주파수 범위는 해머의 질량에 반비례하고 충격해드의 경도에 비 례하는 것으로 알려져 있다. 해머의 질량 자체가 충격력의 크기를 좌우하기 도 하므로, 가진력의 크기를 고려하여 해머의 질량이 선택되며 충격헤드는 충격시간을 조절하기 위하여 적절히 선택된다. 충격해머에 장착된 힘측정기 의 감도는 해머질량과 충격헤드의 질량 변화에 영향을 받게 되는데, 충격 시 험시 측정되는 값은 해머에 부착되어 있는 힘측정기에 가해지는 힘인 반면 구조물에 가해지는 기진력은 충격해드와 구조물사이에 발생되는 힘이다. 이 두 힘의 비는 해머 및 충격해드의 질량효과에 따라 좌우된다. 주어진 충격시 험에서 충격해머의 질량효과를 정확히 조건에 따라 감도보정을 해 주어야 한다. 충격해머의 감도보정에 대해서는 문헌[2]에 잘 나타나 있다. 본 논문에 서는 전압감도에 미치는 영향을 파악하고자 질량 효과를 고려한 수학적 모 형을 제시하고 그 모형의 타당성을 실험을 통해 검정하고자 한다.방법 을 제시하였다. 이와 아울러 제어계의 환경변화에 따른 파라메타의 변화에 적응적으로 응답이 가능해야 하는 적응 소음제어 시스템에서, 음향궤환과 함 께 필히 고려해야 하는 부가적인 전달함수의 영향을 고려한 능동 소음제어 에 대해 연구하였다. 경량화 추세에 따라 지반이나 케이싱이 경량이거나 유연하여 회전축과 동적으로 연성된 경우 회전축-베어링-지반으로 이루어진 2중구조의 회전축 계 동특성을 해석할 수 있는 프로그램을 개발하므로서 회전 기계류의 진동 전반에 걸친 문제점에 대한 그 원인과 현상을 명확히 분석하여 국내의 전기 계류의 보다 신뢰성있는 설계 및 제작자료를 확보하는데 기여할 수 있게 하 였다.존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다. 장비 내에서 반복 시행한 평균값의 차이는 대체적으로 유의한 차이가 없었으나, 다른 장비에서 반복 시행한 장비간의 사이에는 유의한 차이가 있는 경우가 더 많았다. 따라서 , MRS 검사를 소뇌나 뇌교의 어떤 절환에 적용하기 전에 각 장비 마다 정상 기준치를 반드시 얻은 후에 이상여부를 판 정하는 것이 필수적이라고 생각된다.EX> 이상이 적절한 진단기준으로 생각되었다. $0.4{\;}\textrm{cm}^3$ 이상의 좌우 부피차를 보이는 모든 증례에서 육안적으로도 해마위축이 뚜렷이 나타났다. 결론 : MR영상을 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다

  • PDF

Electrical Resistivity Methods in Korea (한국의 전기비저항탐사)

  • Kim, Hee-Joon
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.473-483
    • /
    • 2006
  • Although application of electrical methods in Korea began with observation of self potentials before World War II, the methods were developed slowly by the beginning of 1980's when a major burst of development activity took place. DC resistivity methods are applied in Korea more to geotechnical problems rather than to environmental ones unlike other developed countries. As with every other branch of technology, the evolving speed of the silicon chip and of streaming data to hard disk has revolutionized data collection and noise reduction processing. The last two decades saw major advances in data collection, processing, and interpretation of electrical data. Development of smooth-model two-dimensional (2D) resistivity inversion is one of the most visible changes to geophysical interpretation of the last 40 years and is now routinely applied to apparent resistivity data. The ability to represent resistivities in section rather than pseudosection view has revolutionized interpretation. Although calculation of sensitivities for general electromagnetic problems require numerous forward modelings, DC resistivity methods can enjoy computational efficiencies if sources and receivers occupy the same position, and previously intractable 3D inversion is now becoming available.

Fabrication of the Three Dimensional Accelerometer using Bridge Combination Detection Method (브리지조합 검출방식을 이용한 고온용 3축 가속도센서 제작)

  • Son, Mi-Jung;Seo, Hee-Don
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.196-202
    • /
    • 2000
  • In this paper, we proposed the new bridge combination detection method for three dimensional piezoresistive silicon accelerometer, and the accelerometer with SOI structures was fabricated by bulk micromachining technology for using higher temperature than $200^{\circ}C$. The sensitivities of fabricated accelerometer for X, Y and Z-axis acceleration were about 8mV/V G, 8mV/V G and 40mV/V G. The nonlinearity of the output voltage was 1.6%FS and cross-axis sensitivity was within 4.6%. We confirmed that the three bridges detection method is very simple and the output characteristics of this accelerometer were similar to arithmetic circuit method accelerometer. The temperature characteristics of SOI structure accelerometer showed high operating temperature and good stability. And the temperature coefficient of offset voltage and sensitivity were $1033ppm^{\circ}C^{-1}$ and $1145ppm^{\circ}C$ respectively.

  • PDF

Ammonia Gas Sensing Characteristics of ZnO Based Thin Film Sensor Doped with $MoO_3$ ($MoO_3$를 첨가한 ZnO 박막 센서의 암모니아 가스 검지 특성)

  • Kim, Sung-Woo;Choi, Woo-Chang;Choi, Hyek-Hwan;Lee, Myong-Kyo;Kwon, Tae-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.24-31
    • /
    • 1999
  • Ammonia gas sensors were fabricated with ZnO-based thin films grown by RF-magnetron sputtering method. The films which were doped with $MoO_3$ catalysts of various weight percents were grown in different sputtering gases to fabricate the sensors with a high sensitivity, low working temperature and rapid response time. To improve electrical stability, the films were aged in various conditions. The sensors doped with the catalysts and grown in oxygen sputtering gas showed the improvement of sensitivity. These exhibited the increase of surface carrier concentration and electron mobility. The sensor with 0.875wt.% $MoO_3$ catalysts showed the maximum sensitivity of 70 in ammonia gas concentration of 160 ppm at a working temperature of $300^{\circ}C$. The sensor which is aged at $330^{\circ}C$ for 72hrs in oxygen ambient exhibited tourer sensitivity of 57, but more stable properties, excellent linearity.

  • PDF

Sensitivity Enhancement of Shadow Moiré Technique for Warpage Measurement of Electronic Packages (반도체 패키지의 굽힘변형 측정을 위한 그림자 무아레의 감도향상 기법연구)

  • Lee, Dong-Sun;Joo, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.3
    • /
    • pp.57-65
    • /
    • 2015
  • Electronic packages consist of various materials, and as temperature changes, warpage occurs because of the difference in coefficient of thermal expansion. Shadow $moir{\acute{e}}$ is non-contact, whole field measurement technique for out-of-plane displacement. However, the technique has low sensitivity above $50{\mu}m/fringe$, it is not adequate for the warpage measurement in some circumstance. In this paper, by applying phase shifting process to the traditional shadow $moir{\acute{e}}$, measurement system having enhanced sensitivity of $12.5{\mu}m/fringe$ is constructed. Considering Talbot effect, the measurement is carried out in the half Talbot area. Shadow fringe pattern having four times enhanced sensitivity is obtained by the image process with four shadow fringes. The measurement technique is applied to the fibered package substrate and coreless package substrate for measuring warpages at room temperature and at about $100^{\circ}C$.

$NO_2$ gas sensing properties of $SnO_2$ thin films dopped with Pd and CNT (Pd 및 CNT 첨가에 따른 $SnO_2$ 박막의 이산화질소 감지특성)

  • Kim, H.K.;Lee, R.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.4
    • /
    • pp.101-106
    • /
    • 2008
  • The $SnO_2$ thin films doped with Pd and CNT as $NO_2$ gas sensor were prepared by spin coating and then the $NO_2$ gas response of these films were evaluated under $1ppm{\sim}5ppm\;NO_2$ concentration and operating temperature of $200^{\circ}C$. It was found that the sensor resistance was increased with $NO_2$ exposure and $NO_2$ concentration. The 3wt% Pd doped sample showed a sensitivity of 26.5 which was 10 times higher than that of pure $SnO_2$. And also the sensitivity of CNT doped sample increased with CNT content and it had 72 when 0.225 wt% of CNT was added under 5ppm $NO_2$ concentration.

  • PDF

Enhanced Detection Sensitivity of Surface Plasmon Resonance Biosensing Based on Colocalized Target Molecules and Evanescent Fields (생체분자와 필드의 동시국소화를 통한 플라스몬 센서의 감도향상 연구)

  • Lee, Won-Ju;Oh, Young-Jin;Kim, Dong-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.198-203
    • /
    • 2011
  • We have conducted a theoretical study to improve the detection limit of a surface plasmon resonance (SPR) sensor by co-localizing plasmonic fields and target molecules of interest. The fields were localized by nanograting antennas, while target molecules that participate in a molecular interaction were assumed to be co-localized by angled evaporation of a dielectric mask layer on the nanograting antennas. We have performed the evaluation using an overlap integral between distributions of plasmon fields and molecules and confirmed the correlation of the overlap with the sensitivity of an SPR sensor. Based on the calculated sensor characteristics, it was found that the sensitivity, if the fields and molecules are co-localized, can be as much as ten times that of non-colocalized structure.

A Study on the Development of Electrophotographic Photoreceptor by Dye Sinsitized System (색소증감계를 이용한 전자사진 감광체개발에 관한 연구)

  • Jeong, Eun-Sil;Kim, Yeong-Sun;Jeong, Pyeong-Jin
    • Korean Journal of Materials Research
    • /
    • v.3 no.5
    • /
    • pp.505-513
    • /
    • 1993
  • To make the electrophotographic photoreceptor that srnsirizes for panchromatic matcrial, the dying element of sunfasr yellow which has an absorption ivavclength at near 400nm, and $\alpha,\beta$-copper phthalocyaninc dying elements with 700nm absorption wavelength were adsorbed and then dispersed onto the zine oxide(Zn0). In ordcr to characterize rhe change In sensitivity the various binders and different mole ratio of ZnO to binder were employed in here. It was found rhat the optimum sensitivity was obtained with 5.5 ratio. I;rom the measurements of electrostatic and spectral sensitivity, it was found that the maximum photographic properties were obtained for mixing the sunfast yellow and $\beta$-copper phthalocyaninr. In this case the electrophotographic sensiri\ity was found to he $E{1:2}$= 1440 lux . sec. And also the spectral sensitivity shows that it had a good properties for panchromatic matcrial.

  • PDF

Conjugate Gradient Least-Squares Algorithm for Three-Dimensional Magnetotelluric Inversion (3차원 MT 역산에서 CG 법의 효율적 적용)

  • Kim, Hee-Joon;Han, Nu-Ree;Choi, Ji-Hyang;Nam, Myung-Jin;Song, Yoon-Ho;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 2007
  • The conjugate gradient (CG) method is one of the most efficient algorithms for solving a linear system of equations. In addition to being used as a linear equation solver, it can be applied to a least-squares problem. When the CG method is applied to large-scale three-dimensional inversion of magnetotelluric data, two approaches have been pursued; one is the linear CG inversion in which each step of the Gauss-Newton iteration is incompletely solved using a truncated CG technique, and the other is referred to as the nonlinear CG inversion in which CG is directly applied to the minimization of objective functional for a nonlinear inverse problem. In each procedure we only need to compute the effect of the sensitivity matrix or its transpose multiplying an arbitrary vector, significantly reducing the computational requirements needed to do large-scale inversion.