• Title/Summary/Keyword: 간접 부착법

Search Result 11, Processing Time 0.031 seconds

Effects of direct and indirect bonding techniques on bond strength and microleakage after thermocycling (직접 부착법과 간접 부착법이 열순환 후 부착강도와 미세누출에 미치는 영향에 대한 연구)

  • Ozturk, Firat;Babacan, Hasan;Nalcaci, Ruhi;Kustarci, Alper
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.393-401
    • /
    • 2009
  • Objective: The purpose of this study was to compare the shear bond strength (SBS) of brackets and microleakage of a tooth-adhesive-bracket complex bonded with a direct and an indirect bonding technique after thermocycling. Methods: Fifty non-carious human premolars were divided into two equal groups. In the direct bonding group a light-cured adhesive and a primer (Transbond XT) was used. In the indirect-bonding group, a light-cured adhesive (Transbond XT) and chemical-cured primer (Sondhi Rapid Set) were used. After polymerization, the teeth were kept in distilled water for 24 hours and thereafter subjected to thermal cycling (500 cycles). For the microleakage evaluation, 10 teeth from each group were further sealed with nail varnish, stained with 0.5% basic fuchsin for 24 hours, and examined under a stereomicroscope. Fifteen teeth from each group were used for SBS testing with the universal testing machine and adhesive remnant index (ARI) evaluation. Data were analyzed using the Mann-Whitney U test, Chi-square test, and Fisher's exact test. Results: There were no statistical differences on SBS and microleakage between the two bonding techniques. The indirect bonding group had a significantly lower ARI score. Bracket failures were obtained between enamel-resin interfaces. Conclusions: The type of bonding technique did not significantly affect the amount of microleakage and SBS.

Quantitative Evaluation of Machinability of Free-Cutting Phosphor Bronze Alloy by using a Piezoelectric Tool Dynamometer

  • Cho, Hoon;Lee, Byoung-Soo;Ryu, Ho-Yeun;Jo, Hyung-Ho
    • Journal of Korea Foundry Society
    • /
    • v.27 no.5
    • /
    • pp.217-220
    • /
    • 2007
  • 절삭특성은 재료를 원하는 형상으로 가공하기 위해 재료의 불필요한 부분을 제거할 경우 그 가공성이 쉽거나 어려움에 대한 정도로 전의될 수 있는데 동합금 소재의 절삭특성은 절삭시 발생된 칩의 형상이나 길이를 측정하거나 또는 공구계에 부착된 토오크 미터에 의해 절삭력을 간접적으로 측정하는 방법 등이 사용되어 오고 있다. 상기의 평가방 법은 절삭특성의 간접적인 평가방법이라는 한계와 정확도에 문제가 있는 실정이다. 본 연구에서는 압전형 공구동력계(Piezoelectric Tool Dynamometer)를 쾌삭인청동합금 피절삭물에 직접 부착하여 절삭가공시 절삭력은 정량적으로 직접 측정하고자 하였다. 쾌삭인청동합금의 소둔 열처리 시간이 증가할수록 결정립의 성장에 의한 연화현상과 납입자의 군집화(Clustering)는 관찰되었으나 그로 인한 절삭력 및 절삭에 필요한 에너지의 변화는 뚜렷하지 않았다.

Evaluation of Energy Dependency for Air Kerma Area Product by RQR Beam Quality and Indirect Calibration (RQR 선질에 따른 공기커마 면적선량계의 에너지 의존성 평가와 간접 교정)

  • Kim, Jung-Su;Kim, Sung-Hwan;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.769-776
    • /
    • 2018
  • According IEC 60601-1 ed3.1 and IEC 60601-2-45 regulation, diagnostic X-ray equipment should be display to measured and calculated air kerma area product. On the clinical X ray equipment, air kerma area product dosimeter would like to have an evidence for dosimeter accuracy and energy dependency. This study was performed to indirect calibration and energy dependency test for attached type air kerma area product (KAP) dosimeter by RQR standards beam quality. On the RQR5 beam quality, attached KAP dosimeter error showed -7.5%, respectably. On the RQR9 beam quality, attached KAP dosimeter error showed -10.4%, respectably. All RQR beam quality, average absolute error was $8.30%{\pm}2.85%$, respectably. On this study, attached KAP dosimeter was satisfied to IEC 60580 and AAPM TG 190. This calibration method of KAP dosimeter will help to performance maintain for clinical KAP dosimeter.

Direct and indirect bonding of wire retainers to bovine enamel using three resin systems: shear bond strength comparisons (부착 유지장치의 직, 간접 부착법에 따른 전단 접착력 비교)

  • Kwon, Tae-Yub;Meina, Hu;Antoszewska, Joana;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.447-453
    • /
    • 2011
  • Objective: We compared the shear bond strength (SBS) of lingual retainers bonded to bovine enamel with three different resins using direct and indirect methods. Methods: Both ends of pre-fabricated twisted ligature wires were bonded to bovine enamel surfaces using Light-Core, Tetric N-Flow, or Transbond XT. Phosphoric acid-etched enamel surfaces were primed with One-Step prior to bonding with Light-Core or Tetric N-Flow. Transbond XT primer was used prior to bonding with Transbond XT. After 24 hours in water at $37^{\circ}C$, we performed SBS tests on the samples. We also assigned adhesive remnant index (ARI) scores after debonding and predicted the clinical performance of materials and bonding techniques from Weibull analyses. Results: Direct bonding produced significantly higher SBS values than indirect bonding for all materials. The SBS for Light-Core was significantly higher than that for Tetric N-Flow, and there was no significant difference between the direct bonding SBS of Transbond XT and that of Light-Core. Weibull analysis indicated Light-Core performed better than other indirectly bonded resins. Conclusions: When the SBS of a wire retainer is of primary concern, direct bonding methods are superior to indirect bonding methods. Light-Core may perform better than Transbond XT or Tetric N-Flow when bonded indirectly.

Relation of Correlation about Rice quality related Characters in Condition storage of Unhulled rice (정조 저장조건에서 식미관련특성에 대한 상관성 정도)

  • Hwang, Pil-Seong;Lee, Jeom-Sig;Kim, Kee-Jong;Son, Jong-Rok;Chung, Won-Bok;Oh, Ju-Seong
    • Journal of Life Science
    • /
    • v.17 no.4 s.84
    • /
    • pp.510-514
    • /
    • 2007
  • This study was carried on cool and RT(room temperature) storage of unhulled rice. In RT storage of an analysis of coefficient relation, high significant positive coefficients were observed in toyo index and breakdown, setback and protein content. high significant negative coefficients were showed setback and breakdown, breakdown and protein content. In cool storage of an analysis of coefficient relation, high significant positive coefficients were observed in toyo index and amylose content and gelatinization start temperature and protein content and high significant negative coefficients were showed toyo index and whiteness, toyo index and gelatinization start temperature, gelatinization start temperature and amylose content. In RT storage of a path coefficient analysis, a highest positive direct influence was observed in amylose content and a highest negative direct influence was protein content. Positive indirect influence was high revealed breakdown and protein content and negative indirect influence was gelatinization start temperature and Mg/K ratio. In cool storage of a path coefficient analysis, a highest positive direct influence was whiteness and a highest positive indirect influence was gelatinization start temperature. Positive indirect influence was high revealed gelatinization start temperature and amylose content, negative indirect influence was whiteness and gelatinization start temperature. In RT storage of Multiple regression equation of Toyo index based on physicochemical properties of unhulled rice, a highest coefficient of determination was revealed among five facters of whiteness, protein content, Mg/K ratio, amylose content and gelatinization start temperature. In cool storage of Multiple regression equation of toyo index based on physicochemical properties of unhulled rice, highest coefficient of determination was revealed among five facters of moisture content, amylose content, gelatinization start temperature, breakdown and setback.

Availability Analysis of Safety Devices installed for Preventing Accidental Event in the LPG Refuelling Station (LPG충전소 안전장치의 사고방지 효과에 대한 정량적 분석)

  • Lee Jin-Han;Yu Kwang-Soo;Park Kyo-Shik
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.26-31
    • /
    • 2006
  • For the purpose of evaluating the availability of manifold safety devices installed in the LPG(Liquefied Petroleum Gas) refuelling stations, the quantitative analysis of the frequency on BLEVE(Boiling Liquid Expanding Vapor Explosion) scenario was performed. The amount of frequency reduction was the way of assessing safety devices availability. In this analysis, we could find out what sorts of safety devices are essential to satisfy acceptable social risk criteria and are prioritized to install in the future.

  • PDF

Long-term effects of chlorhexidine varnish treatment on microbial changes of dental plaque in orthodontic patients with fixed appliances (Chlorhexidine varnish 처치 후 고정식 교정장치 장착 환자의 치태내 균주 변화 양상에 대한 장기간 관찰 연구)

  • Chang, Young-Il;Yang, Won-Sik;Nahm, Dong-Seok;Kim, Tae-Woo;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.335-342
    • /
    • 2000
  • The authors observed the long term effects of chlorhexidine varnish treatment on microbial change of dental plaque in orthodontic patients with fixed appliances. The initial sample was 100 patients who were arranged to be treated with fixed orthodontic appliances. The final sample consisted of 21 patients who could be traced for 32 weeks after application of fixed orthodontic appliances. They were classified into the experimental group (12 patients) and the control group (9 patients). The experimental group was treated with chlorhexidine varnish once a week for 4 weeks before application of fixed orthodontic appliance. The control group was not treated with chlorhexidine varnish before application of fixed orthodontic appliance. The experimental group was treated once more after 20 weeks. The microbial changes of dental plaque were analysed by indirect immunofluorescence technique at pre-treatment, post-treatment 4, 8, 20, and 32 weeks. The results were as follows. 1. In the experimental group, streptococus mutans was significantly suppressed during experimental period. (p<0.01) But, in the control group, streptococcus mutans was significantly increased after placement of fixed orthodontic appliances during experiment period. (p<0.05) 2. Streptococcus sanguis, Streptococcus mitis, Actinomyces viscosus, md Actinomyces naeslundii did not show significant change between the experimental and the control group during experiment period. So, if we treat the orthodontic patients with chlorhexidine varnish before application of fixed appliances, we may suppress the major cariogenic bacteria, Streptococcus mutans, selectively for long period.

  • PDF

A Study on Tension for Cables of a Cable-stayed Bridge Damper is Attached (댐퍼가 부착된 사장교의 케이블 장력에 관한연구)

  • Park, Yeon Soo;Choi, Sun Min;Yang, Won Yeol;Hong, Hye Jin;Kim, Woon Hyung
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.609-616
    • /
    • 2008
  • Recently, many ocean bridges that connect land to island or island to island have been constructed along with the improvement of the nation's economy. Long-span bridges can be categorized as suspension bridge, cable-stayed bridge, arch bridge and truss bridge. In this study, correction with respect to construction error can be presented on site through the monitoring of the cable tension change of real structure for four major construction stages so that construction accuracy, including the management of profiles, can be improved. A vibration method, the so-called indirect method that uses the cable's natural frequency changes from the acceleration sensor installed on the cable, is applied in measuring cable tension. In this study, the estimation formula for the effective length of cable with damper is presented by comparing and analyzing between actual measurement and analysis result for the change of the cable's effective length. By the way, it is known that the reliability of estimating cable tension by applying the former method that uses the net distance from damper to anchorage is low. Therefore, for future reference of the maintenance stage, the presented formula for estimating the effective length of cable can be used as a reference for the rational decision-making, such as the re-tensioning and replacement of cable.

A Study on the Contribution of Exterior Devices to Running Resistance in High-Speed Trains (고속열차 외부장치에 의한 주행저항 기여도 연구)

  • Oh, Hyuck Keun;Kwak, Minho;Kwon, Hyeok-bin;Kim, Sang-soo;Kim, Seogwon
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.4
    • /
    • pp.309-316
    • /
    • 2015
  • The contribution of exterior devices such as bogie fairings and pantographs to running resistance was estimated on the basis of coasting tests at up to 350 km/h with the help of the Korean Next Generation High speed train (HEMU-430X). In order to assess the reduction of air resistance by nose car's bogie fairing, coasting tests were conducted with a removable bogie fairing at various speed ranges. And, the contribution of the pantograph to air resistance was also estimated with coasting tests that include the pantograph's rising and descent modes. The linear regression method was used to examine decelerations from time-velocity data and the equation of resistance to motion is proposed from the deceleration data. From the aerodynamic term of the equation of resistance to motion, the contribution to air resistance by nose car's bogie fairing and pantograph was estimated. The results show that the air resistance was reduced by about 3.8% by the nose car's bogie fairing. And, the 3.9% increase of air resistance by the pantograph (open knee mode) has been found.

Application of 3D printer in dental clinic (치과 진료실에서 3D 프린트의 활용)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.82-96
    • /
    • 2018
  • 3D printing is a process of producing 3d object from a digital file in STL format by joining, bonding, sintering or polymerizing small volume elements by layer. The various type of 3d printing is classified according to the additive manufacturing strategies. Among the types of 3D printer, SLA(StereoLithography Apparatus) and DLP(Digital Light Processing) 3D printer which use polymerization by light source are widely used in dental office. In the previous study, a full-arch scale 3d printed model is less precise than a conventional stone model. However, in scale of quadrant arch, a 3d printed model is significantly precise than a five-axis milled model. Using $3^{rd}$ Party dental CAD program, full denture, provisional crowns and diagnostic wax-up model are fabricated by 3d printer in dental office. In Orthodontics, based on virtual setup model, indirect bracket bonding tray can be generated by 3d printer. And thermoforming clear aligner can be fabricated on the 3d printed model. 3D printed individual drilling guide enable the clinician to place the dental implant on the proper position. The development of layer additive technology enhance the quality of 3d printing object and shorten the operating time of 3D printing. In the near future, traditional dental laboratory process such as casting, denture curing will be replaced by digital 3D printing.