• Title/Summary/Keyword: 간이 측정기

Search Result 263, Processing Time 0.036 seconds

Model Tests for the Applicability of various Testing Devices for Measuring Degree of Compaction (여러 가지 다짐평가 장비의 적용성에 대한 모형 시험)

  • Back, In-Chul;Yoo, Wan-Kyu;Kim, Byoung-Il;Kim, Ju-Hyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1152-1158
    • /
    • 2007
  • Although various fast and simple, testing devices have been developed in many countries such as the U.S, Japan, and European countries, these testing devices are not commonly used in Korea. In this study, compaction fur the field density test was carried out with a hand-guided vibrating roller. The results of the field density test were compared with those of the new testing devices such as the geogauge, soil impact hammer(CASPFOL), light falling weight deflectometer(LFWD), dynamic cone penetration(DCP). Regression analyses were conducted with the data from new testing devices. The analysis results showed that the correlation coefficients were high in the range of $70{\sim}95%$.

  • PDF

The development of a high level radiation detector for reactor inspection robot (원자로 검사 로봇용 고준위 방사선 측정기 구현)

  • Lee, Nam-Ho;Cho, Jai-Wan;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.278-280
    • /
    • 2005
  • 원자력발전소 내 원자로의 유지보수 작업을 수행하는 수중로봇은 고준위 방사선에 노출되고, 이로 인해 전자 장치의 오동작 및 고장이 유발될 수 있다. 따라서 허용 방사선량을 초과하지 않도록 피폭되는 누적 방사선량을 실시간으로 모니터링하는 장치가 필수적이다. 본 연구에서는 펄스형의 SiC 포토 다이오드와 선량 기억형인 MOSFET를 다중 방사선 센서로 사용하여 넘은 범위의 방사선 준위의 측정이 가능하고 측정 신뢰도가 향상된 고준위 방사선 측정기를 구현하였다. 이 장치는 측정 원리가 상이한 두 센서를 동일한 방사선 측정에 이용함으로써 방사선 측정의 안정성과 정확성이 향상된 것이 특징이다.

  • PDF

Determination of Surface Energy by Means of Home-Made Goniometer and Image Analyzing Software for Contact Angle Measurement (수제 접촉각 측정기와 영상 분석 프로그램을 이용한 표면에너지의 측정)

  • Cho, Seo-Rin;Cho, Han-Gook
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.4
    • /
    • pp.432-438
    • /
    • 2013
  • We report a contact angle goniometer that can be easily assembled and used in high school and general chemistry experiments. It consists of an LED flash, a sample stand, and a camera fixed on an optical bread board, and the sample area is covered to block light from outside with a box with holes on both sides. ImageJ, free image analyzing software and a JAVA plugin (Drop_analysis) were used to determine the contact angle of liquid drop resting on solid surface. The contact angles of various liquids were successfully measured on various surfaces. The solid surface energies have also been determined using the Owen-Wendt method from the contact angles of $H_2O$ and $CH_2I_2$. The results reasonably agree with the previously reported values, showing the surface characteristics and modification as well as the dispersive and polar contributions. These contact angle goniometer and method for determination of the contact angle and surface energy can be applied to observation of various surface properties including wettability, hydrophilicity, and water repelling. Students can learn how the surface properties are related to the intermolecular interactions and gain experience about the equilibrium between the related forces, optics, and mathematical derivations.

Use of Beam Transmissometer as an Indirect Measure of Suspended Sediment Concentration in the Estuarine Environment: Application and Problems (강하구에서의 부유물질농도 결정을 위한 광전도측정기의 이용 및 문제점)

  • KIM Seok-Yun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.6
    • /
    • pp.771-781
    • /
    • 1994
  • Monthly measurements made at 15 stations along the axis of the upper Neuse River estuary show a highly variable degree of correlation between concentration of suspended particulate material (SPM) and attenuation coefficient (c) of light as measured by transmissometer. Coefficients of determination along transect lines ranged from $0.12{\sim}0.93$ and calibration slopes ranged from $0.50{\sim}5.63$. When examined on a station-by-station basis, coefficients of determination ranged from $0.21{\sim}0.96$ and calibration slopes ranged from $1.04{\sim}4.94$. Surface calibrations made at individual stations over the full 13-month period were the most consistent of all observations and were considerably better than calibrations made using all of the stations on a given day. Organic content, which can dominate the suspended sediment load during some months, does not appear to explain the variations in reliability of the calibrations. However, an abundance of large aggregates with time-varying size and shape distributions may be partly responsible for variations in optical properties of the sediments, and thus may confound the relationship between SPM and c in the Neuse River estuary Time-varying calibrations to account for non-negligible changes in optical properties may not suffice in complex estuarine environments where the in situ particle dynamics are poorly understood. However, the best use of Beam Transmissometer will continue to be for applications such as detecting water-column events or for use in situations where wide error bars in establishing SPM concentrations are acceptable.

  • PDF

IN VITRO EVALUATION OF ACCURACY AND CONSISTENCY OF FOUR DIFFERENT ELECTRONIC APEX LOCATORS (4종 전자근관장측정기의 정확성과 일관성에 관한 in vitro 연구)

  • Cho, Jae-Hyun;Kum, Kee-Yeon;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.390-397
    • /
    • 2006
  • The purpose of this study was to evaluate the accuracy and the consistency of four different electronic apex locators in an in vitro model. Fourty extracted premolars were used for the study. Four electronic apex locators (EAL) were Root ZX, Smarpex, Elements Diagnostic Unit (EDU), and E-Magic Finder Deluxe (EMF). After access preparation, the teeth were embedded in an alginate model and the length measurements were carried out at '0.5' and 'Apex' mark using four EALs. The file was cemented at the location of the manufacturers' instruction (Root ZX, EDU, EMF: 0.5 mark, SmarPex: Apex mark). The apical 4mm of the apex was exposed and the distance from the file tip to the major foramen was measured by Image ProPlus (${\times}100$). The distance from the file tip to the major foramen was calculated at 0.5 and Apex mark and the consistency of 0.5 and Apex mark was compared by SD and Quartile of Box plots. In this study, Root ZX and EMF located the apical constriction accurately within ${\pm}0.5 mm$ in 100%, whereas SmarPex and EDU located in 90% and in 70% respectively. For Root ZX and EMF, there was no significant difference between the consistency of 0.5 and Apex mark. However, for the EDU and SmarPex, Apex mark was more consistent than 0.5 mark. From the evaluation of the consistency in this study, for Root ZX and EMF, both 0.5 and Apex mark can be used as a standard mark. And for EDU and SmarPex, the Apex mark can be recommended to be used as a standard mark.

Stability Evaluation on Measuring Water-soluble Chloride Anions from Iron Artifacts (철제유물의 수용성 염소이온 측정방법에 대한 안정성 평가)

  • Lee, Jae-Sung;Park, Hyung-Ho;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.397-406
    • /
    • 2010
  • The most ideal method to measure the water-soluble $Cl^-$ ion eluted from iron artifacts is conducting the analysis on desalting solution by Ion Chromatography. But most institutes related to cultural heritages use Cl meter by reason of lack of budget and experts. This study evaluated reliability and stability between Cl meter and Ion Chromatography by doing cross-validation with results from two methods to detect $Cl^-$ ion of desalting solution. From D.I water, extremely small quantities of $Cl^-$ ion was detected by the influence of remaining water-soluble $Cl^-$ ion at the electrode of Cl meter and water-soluble $Cl^-$ which remains in Sodium sesquicarbonate, components of reagent was detected as well. The first desalting solution had the most $Cl^-$ ions, $Cl^-$ ion slightly decreased from the second to the fourth desalting solution and tend to decrease again at the stage of dealkalified in D.I water. Each Cl meter has the standard deviation according to the measured numbers and the higher concentration of $Cl^-$ ion the desalting solution has, the wider the deviation is. But when the concentration of $Cl^-$ ion is low, it was stable to use Cl meter to detect the concentration of $Cl^-$ ion from iron artifacts because there is the small deviation, It is thought that conductivity meter method is not suitable for measuring $Cl^-$ ion, because the electrical conductivity of alkaline solution is too high to measure $Cl^-$ ion.

Robust Real-Time Visual Odometry Estimation for 3D Scene Reconstruction (3차원 장면 복원을 위한 강건한 실시간 시각 주행 거리 측정)

  • Kim, Joo-Hee;Kim, In-Cheol
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.4
    • /
    • pp.187-194
    • /
    • 2015
  • In this paper, we present an effective visual odometry estimation system to track the real-time pose of a camera moving in 3D space. In order to meet the real-time requirement as well as to make full use of rich information from color and depth images, our system adopts a feature-based sparse odometry estimation method. After matching features extracted from across image frames, it repeats both the additional inlier set refinement and the motion refinement to get more accurate estimate of camera odometry. Moreover, even when the remaining inlier set is not sufficient, our system computes the final odometry estimate in proportion to the size of the inlier set, which improves the tracking success rate greatly. Through experiments with TUM benchmark datasets and implementation of the 3D scene reconstruction application, we confirmed the high performance of the proposed visual odometry estimation method.

Development of Tilt angle measurement system of plastic thin-film using Position Sensitive Device (PSD를 이용한 플라스틱 박막 필름의 경사 각도 측정 시스템 개발)

  • Kim, Gi-Seung;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.134-138
    • /
    • 2021
  • Various types of precision plastic thin films are used widely in high-performance displays, such as smartphones. For plastic thin-films manufactured by the Roll-to-Roll process, the film thickness must be measured and managed while moving. In the Roll-to-Roll process, wrinkles are generated when tension is applied to the film, which causes an inclination on the optical axis of the thickness gauge, resulting in a loss of accuracy. Therefore, this study attempted to develop an optical interference tomography measurement system. In this study, the tilt angle of the film was measured to correct the measurement value error in the thickness gauge caused by the tilt of the film. The system was constructed so that the laser was irradiated on the tilted film, and the laser reflected from the film was formed on the PSD. The relationship between the tilt angle of the film and the output value of the PSD was obtained experimentally. Using this, a device to measure the tilt angle of the film was constructed, and angle measurements were taken at a speed of 250,000Hz.

Analysis of digital monitoring of TOC using a spectrometer in river (하천에서의 분광측정기를 이용한 TOC 디지털 모니터링 분석 연구)

  • Soo Bin Yoon;Chang Hyun Lee;Ho Soo Lee;Ye Lim Park;Young Do Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.195-195
    • /
    • 2023
  • 유기물오염은 호수와 하천에서 가장 흔히 나타나는 오염의 형태이다. 개발도상국에서는 하수처리시설이나 생활용수처리시설에서 유기물이 처리되지 않아 수중의 유기물함량이 증가하여 피해가 나타난다. 물환경보전법에 따라 유기물질을 측정하는 지표에는 BOD, COD, TOC가 있다. 그 중 BOD, COD 측정은 절차가 복잡하고 오래 걸리며, 생물분해가 불가능하거나 유독물질이 존재하는 유기물질인 경우에는 낮은 결과 또는 측정이 불가능하다. 이러한 이유로 환경부에서는 TOC중심관리로 전환되고 있다. 대부분의 수질항목 측정의 경우 현장시료를 채취하여 실험실에서 분석하는 수분석을 이용한다. 하지만 수분석의 경우 인력이 많이 투입되고 분석수가 한정적이며, 정교한 과학 장치를 갖춘 전문 실험실을 필요로 한다. 반면에 TOC는 짧은 시간 내에 측정이 가능하고, 안정적인 산화로 유기물질 총량을 정확하게 측정이 가능하다. 또한 위해성 물질을 발생시키지 않는 친환경적 방법이라 환경오염 감시에 많이 활용된다. 본 연구에서 분광측정기 중 하나인 S-CAN을 통해 하천의 TOC분석을 진행하였다. 대상지는 안동에 위치한 하천실험센터와 금호강 진천천으로 S-CAN측정과 채취한 시료의 수분석 결과를 비교하였다. 이를 통해 TOC측정 및 기기에 대한 정확도분석을 실시하였다. 본 연구를 통해 S-CAN을 활용한 TOC중심의 수질모니터링하여 수질의 특성을 탐구하고, TOC기초연구를 통한 유기물오염도 지표로서 해석할 수 있다. 수분석 자료를 활용한 정확도 비교를 통해 하천 TOC센서 측정 적용에 대한 기초자료 제공과 측정기기의 현장적용성을 판단 할 수 있다. TOC측정 및 분석을 통해 유기물질량을 실시간으로 정확하게 측정하게 되면 수질관리 효율성이 높아지고, 하천에 유입되는 유기물질량과 농도를 정확하게 파악하여 실효성 있는 정책 수립 및 효율적인 수질관리를 할 수 있다.

  • PDF

A Study on Analysis of Fine Dust Measuring System to Improve Quality of Life (삶의 질 향상을 위한 미세먼지 측정 시스템 분석 연구)

  • Lee, Kwang-Jae
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.6
    • /
    • pp.69-77
    • /
    • 2019
  • Among the many factors that threaten the improvement of public health and quality of life, the proportion of fine dust is not so small, and the kinds and causes of the dust are also diversified. However, the domestic measuring instrument is in the initial stage and the certification system is insignificant. Recognizing the threat of fine dust for a long time, the United States has established a protocol of measurement standards and measurement methods and applied the developed fine dust measuring device authentication system. Through this system, the United States is leading the world's fine dust industry, technology and market. The EPA, FRM and FEM of the fine dust-related protocol were analyzed to reduce the harmful effects of repeated fine dust every year. In addition, light scattering method and spectroscopy method which can measure in real time by measuring method were examined, and the types and characteristics of fine dust measuring instrument of international certification level were analyzed. Finally, development and service plan of the domestic fine dust measuring instrument are presented.