• Title/Summary/Keyword: 간섭검사

Search Result 196, Processing Time 0.029 seconds

Domestic Radio Waves Propagate Management and Control Systems Investigate the System Status (주요선진국 전파관리제도와 국내 전파관리 제도에 대한 조사)

  • Kim, Sung-Hong;Seok, Gyeong-Hyu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • There propagate use management paradigm in developed countries is changing as Command & Control ${\Rightarrow}$ Market Based ${\Rightarrow}$ Open Access ${\Rightarrow}$ Manage By Technology & Technical Analysis, that the policy response to environmental changes, such as a variety of new technologies. The emergence of service, the proliferation of propagation users It is to activate the market. However, the basic principles of radio management such that the change of paradigm be used to spread in a range that does not affect the interference, such as the horn is to be observed. Around the world in order to prevent the propagation and utilization Horn interference enacted regulations for managing the radio station, and also discipline.

Performance Analysis of 16 star-QAM with Diversity Reception in Microcell Systems (마이크로셀 시스템에서 다양성 기법을 도입한 16 star-QAM의 성능 해석)

  • 지수복;고봉진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1A
    • /
    • pp.1-9
    • /
    • 2000
  • This paper presents the error performance of 16 star-QAM with diversity reception in microcell systems in the presence of additive white Gaussian noise(AWGN) and cochannel interference. The differential detection of 16 star-QAM is split into phase detection and amplitude detection. This technique can reduce the degradation of error performance which is due to fading and the complexity of receiver. Diversity reception is proposed to improve the degradation of error performance due to fading. Equal gain and maximal ratio combinings were adopted for the phase detection and the amplitude detection, respectively. The performance of 16 star-QAM was evaluated for various of Rician factor K, maximum Doppler frequency f_DT, signal to cochannel interference ratio and diversity branch L.

  • PDF

Exophthalmometric values using White-light Scanning Interferometer (백색광 간섭계를 이용한 안구돌출값 측정)

  • Chang, Jung-Soo;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.175-178
    • /
    • 2017
  • The relative position of the eyeballs in the orbit can be a criterion for estimating multiple pathological conditions. Especially, it is useful to diagnose orbital fracture, thyroid eye disease, orbital tumor, and to evaluate the result of drug and surgical treatment. The Hertel and the Naugle exophthalmometer, which are typical measuring instruments used mainly to measure the protrusion of the eye, are inevitably error by the measurer. In this paper, we propose a method to increase the accuracy and repeatability of the measurement of eyeball exophthalmometric values by using a white light interferometer.

  • PDF

Clinical Applications of Intracoronary OCT (Invited Paper) (심혈관 OCT의 임상적 응용)

  • Ha, Jinyong;Kim, Jung-Sun;Hong, Myeong-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • The most common cause of a heart attack is known as coronary artery disease, which narrows the arteries and reduces the blood flow to the heart. To treat coronary artery stenosis, percutaneous coronary intervention (PCI) (a nonsurgical procedure to install a stent, which holds the artery wall open) is performed. Intracoronary optical coherence tomography (OCT) is a catheter-based, invasive optical imaging system. To determine whether PCI is appropriate, and to perform stent evaluation in a catheterization laboratory, OCT examinations are carried out. This review details the fundamental principles and technological status of intracoronary OCT imaging, and discusses the ongoing clinical applications to determine the benefits of OCT-guided PCI.

Study on the Radio Regulations of the ITU Radio Regulations institutions and developed countries before and after regulations (ITU의 전파관리제도와 주요선진국 전파관리 사전 사후 규제에 대한 연구)

  • Choi, Woo-Jin;Shin, Hyun-Shin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.553-560
    • /
    • 2016
  • There propagate use management paradigm in developed countries is changing as Command & Control $\Rightarrow$ Market Based $\Rightarrow$ Open Access $\Rightarrow$ Manage By Technology & Technical Analysis, that the policy response to environmental changes, such as a variety of new technologies. The emergence of service, the proliferation of propagation users It is to activate the market. However, the basic principles of radio management such that the change of paradigm be used to spread in a range that does not affect the interference, such as the horn is to be observed. Around the world in order to prevent the propagation and utilization Horn interference enacted regulations for managing the radio station, and also discipline.

A Measurement Method of Internal Defects of Pressure Vessles by Using Real-Time Holographic Interferometry (실시간 홀로그래픽 간섭법을 이용한 압력용기의 내부결함 측정법)

  • Moon, Sang-Joon;Kang, Young-June;Baik, Sung-Hoon;Kim, Cheol-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1233-1240
    • /
    • 1996
  • Conventional measurement methods using ultrasonic wave or x-ray, eddy current for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been utilized as the method of contact with objects to be inspected. For this reason these methods require relatively much time and inspection area is limited by the location of probe or film. But holograpic interferometry which is a non-contact optical measurement method using a coherent light source has an advantage that quantative measurement can be performed at a time. In this paper a new method using realtime holographic interfreometry and image processing for detecting internal flaws of pressure vessels is presented.

Technology of Non-destructive Stress Measurement in Spot Welded Joint using ESPI Method (ESPI법에 의한 스폿 용접부의 비파괴적 응력측정 기술)

  • 김덕중;국정한;오세용;김봉중;유원일;김영호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2000
  • In spot welded joint. Electronic Speckle Pattern Interferometry(ESPI) method using the Model 95 Ar laser a video system and an image processor was applied to measure the stress Unlike traditional strain gauges or Moire method, ESPI method has no special surface preparation or attachments and can be measured in-plane displacement with non-contact and real time. In this experiment, specimens are loaded in parallel with a load cell. The specimens are made of the cold rolled steel sheet with 1mm thickness, are attached strain. gauges. This study Provides an example of how ESPI has been used to measure stress and strain inspecimen. The results measured by ESPI are compared with the data which was measured by strain gauge method under tensile testing.

  • PDF

Tenodesis of Long Head of the Biceps Brachii Tendon with Bioabsorbable Interference Screw (체내 흡수성 간섭 나사를 이용한 상완 이두건 장두건 고정술의 임상적 결과)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Lee, Sang-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.78-83
    • /
    • 2007
  • Purpose: This study reports the clinical results of the tenodesis of long head of the Biceps brachii tendon with bioabsorbable interference screw by minimal open procedure. Materials and Methods: Ten cases of 10 patients (7 male, 3 female) were included in this study. The average age was 45.8 years old and the average period from the symptom onset to operation was 13.7 months. Average preoperative ASES score was 38.5. The causes of injury was; sports activities in 4 patients, unknown in 4 patients, industrial accident in 1 patient and traffic accident in 1 patient. The average follow up period was 12.1 months. Tenodesis with bioabsorbable interference screw by minimal open precedure was performed in all cases. Results: The ASES score improved to 87.5 at last follow up period and 6 cases had full range of motion of the shoulder. 4 cases had mild limited range of motion of the shoulder without any problem in normal daily activity. Conclusion: It was assumed that tenodesis of long head of the biceps brachii tendon with bioabsorbable interference screw by minimal open precedure was one of the good methods with good clinical results.

A correlation between bruxism and eccentric occlusal interferences (이갈이와 편심위 교합간섭의 상관관계 분석)

  • Lee, Ho-Sun;Kim, Mi-Gyeong;Jin, Soo-Yoon;Kim, Hee-Jung;Lee, Gyeing-je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.253-261
    • /
    • 2018
  • Purpose: The purpose of this study was to analyze correlation between bruxism and occlusal contacts on balancing side. Materials and Methods: The purpose of this study is to compare the difference of group function and balancing side occlusal contacts according to bruxism and sex, A total of 100 adults that aged 26-37 years (39 bruxers and 61 non-bruxers) were examined. The lateral excursion and balanced occlusal contacts were analyzed to determine the correlation with bruxism. The occlusal contacts were recorded by T-Scan system and articulating paper. Results: The group function was the highest in 61.5% of bruxers and 47.5% of non-bruxers. In comparison between males and females, group function was 58.9% in males and 37.0% in females. Occlusal contacts on non-working side occurred in 48 out of 100 patients. There were 51.2% of the cases in the bruxers and 46.0% in the non-bruxers. Statistically, there was no correlation between the bruxism and occlusal contacts on non-working side. There was no correlation between sex and balancing occlusal contacts. Conclusion: There was no significant correlation between bruxism and occlusal contacts on non-working side. The group function was the highest in bruxers when lateral excursion was occurred.

An implementation of 2D/3D Complex Optical System and its Algorithm for High Speed, Precision Solder Paste Vision Inspection (솔더 페이스트의 고속, 고정밀 검사를 위한 이차원/삼차원 복합 광학계 및 알고리즘 구현)

  • 조상현;최흥문
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.139-146
    • /
    • 2004
  • A 2D/3D complex optical system and its vision inspection algerian is proposed and implemented as a single probe system for high speed, precise vision inspection of the solder pastes. One pass un length labeling algorithm is proposed instead of the conventional two pass labeling algorithm for fast extraction of the 2D shape of the solder paste image from the recent line-scan camera as well as the conventional area-scan camera, and the optical probe path generation is also proposed for the efficient 2D/3D inspection. The Moire interferometry-based phase shift algerian and its optical system implementation is introduced, instead of the conventional laser slit-beam method, for the high precision 3D vision inspection. All of the time-critical algorithms are MMX SIMD parallel-coded for further speedup. The proposed system is implemented for simultaneous 2D/3D inspection of 10mm${\times}$10mm FOV with resolutions of 10 ${\mu}{\textrm}{m}$ for both x, y axis and 1 ${\mu}{\textrm}{m}$ for z axis. Experiments conducted on several nBs show that the 2D/3D inspection of an FOV, excluding an image capturing, results in high speed of about 0.011sec/0.01sec, respectively, after image capturing, with $\pm$1${\mu}{\textrm}{m}$ height accuracy.