• Title/Summary/Keyword: 간극센서

Search Result 42, Processing Time 0.034 seconds

An Analytical Study on the Durability Standard of Ground Structures Monitoring Sensors (지반구조물 계측센서의 내구연한 기준에 대한 분석적 연구)

  • Woo, Jong-Tae
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.53-59
    • /
    • 2021
  • Purpose & Method: The purpose of this study is the theoretical study on the durability standard of ground structures monitoring sensors. A survey on the durability criteria for construction monitoring sensors of domestic construction companies and the income tax implementation regulations, the standard years of contents such as buildings and the standards of the Public Procurement Service for construction monitoring and construction machinery were analyzed. Result: The durability criterion such as the inclination meter and the strain gauge, which are purchased from the Public Procurement Service prior to installation on the ground structure, is 8 to 10 years. Conclusion: The actual durability analysis by comparing the reliability of various monitoring sensors installed in dams at home and abroad, As a result of comprehensive study on the loss and damage rate of the maintenance monitoring sensor installed in the tunnel, the proper durability period of the built-in type monitoring sensor such as domestic pore pressure meter and earth pressure meter installed in the structure or the ground is 5 to 8 years it seems reasonable.

Development of Ultrasonic Magnetostrictive Sensors System to Measure in Very High Temperatures (초고온 온도 측정을 위한 초음파 자왜 센서 시스템 개발)

  • 구길모;김상백;박치승;최종호;고덕영
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.66-74
    • /
    • 2001
  • The temperature measurement of yen high temperature core melt is of importance in LAVA (Lower-plenum Arrested Vessel Attack) experiment in which gap formation between core melt and the reactor lower head, and the effect of the gap on thermal behavior are to be measured. The delay time of ultrasonic wavelets due to high temperature is suggested. As a first stage, a molten material temperature was measured up to 2300℃. Also, the optimization design of the ultrasonic temperature sensor with persistence at the high temperature was suggested in this paper. And the utilization of the theory suggested in the reference〔1〕and the efficiency of the developed system are certified by performing experiments. This sensor welded magnetostrictive element and tungsten element will be able to measure a temperature range of 3000℃ hereafter.

  • PDF

Development of Fiber Optic Total Reflected Extrinsic Fabry-Perot Interferometric Sensor for Structural Strain Measurement (구조물의 변형률 측정을 위한 광섬유 TR-EFPI 센서의 개발)

  • Kwon, In-Bum;Choi, Man-Yong;Moon, Hahn-Gue;Kim, Min-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.96-105
    • /
    • 2000
  • Fiber optic TR-EFPI(total reflected extrtinsic Fabry-Perot interferometric) sensor was developed to measure the strain of structures, such as building, bridge, aircraft, etc. It has been difficult to distinguish the increase and decrease of the strain from the conventional fiber optic EFPI sensor because their signals only have a sinusoidal wave pattern related to the change of strain. Also, the absolute strain could not be measured by the simple fiber optic EFPI sensor. In this study, in order to measure the magnitude of strain with the direction of strain, the fiber optic sensor was simply constructed with the total reflected EFPI sensor probe. This probe was manufactured with a single mode fiber and a mirror coated fiber in a silica glass capillary tube. The output signal of this fiber optic TR-EFPT sensor can give the information about the magnitude and the direction of strain. The loading-unloading test was performed by the universal testing machine with alluminum beam specimen to compare the strain from fiber optic TR-EFPI sensor with the value from electrical strain gauge. In the result of this experiment. the strain from fiber optic TR-EFPI sensor had a good agreement with the values from the electrical strain gauge.

  • PDF

A Study on Previous Plan for Levee Leakage Monitoring Sensors (제방누수감지센서 설치를 위한 사전계획 연구)

  • Park, Kyoung-Won;Jung, Kwan-Su;Lee, Gwang-Man;Hwang, Eui-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.669-673
    • /
    • 2012
  • 제방안전성 모니터링은 제방파괴로부터 국민의 생명과 재산을 보호하는데 필요한 정보를 얻을 수 있는 하나의 방법이 될 수 있다. 근래에 미국은 2005년 허리케인 카타리나에 의해 2,000여명의 인명손실을 경험하였고 2011년 3월 일본은 도후쿠지역의 초강력 지진에 의한 쓰나미로 인해 수만명의 인명과 후쿠시마 원자력 발전소의 침수로 지금까지 방사능 누출 차단작업을 벌이고 있다. 국내에서는 4대강 복원사업으로 주요 국가 하천 구간에서 홍수 및 체제 불안정에 의한 제방붕괴사고위험이 현격하게 줄어들었으나 제방의 안전성은 더욱 강조되고 있다. 즉 신설된 보 주변, 배수통문 신설구간 그리고 제방누수 예상지점 등에서는 아직 안전한 상태라고 확신할 수 없으며 지속적인 모니터링이 요구된다. 따라서 본 연구에서는 광섬유를 이용하여 개발한 간극수압 및 온도 센서 등을 위험예상지점에 설치하고 정보시스템을 통하여 어떻게 관리 할 것인가에 대한 사전 검토를 계획하였다. 이를 위하여 제방에 센서를 설치하기 전에 주요 검토사항에 대하여 연구분석하였다. 주요 검토사항에는 설치하고자 하는 지점의 제방거동 메커니즘 예측, 왜 계측시스템을 설치하는지에 대한 목적에 대한 평가, 설치 지점의 제방의 토질공학적 문제점 파악, 모니터링 대상 매개변수 혹은 항목 선정, 조사대상 항목의 변화정도를 예측하여 거동 범위 확정, 적정 계측기기 설치 지점을 선청, 계측기기 선정, 자동화 혹은 실시간 정보시스템에 필요한 사항 결정, 관측에 영향을 미치는 인자들의 기록 계획, 정보의 타당성 확보를 위한 필요사항 정립, 비용의 결정, 장기 예측 계획, 정기 검 보정 및 관리 계획, 자료수집 및 관리계획, 자원의 공조 및 생애주기 비용 등을 포함하였다.

  • PDF

Optical Cap Sensor for Magneto-Optic Near-Field Recording (MO 근접장 기록을 위한 광학 갭 센서)

  • Yoon, Yong-Joong;Park, Jae-Hyuk;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.245-250
    • /
    • 2004
  • This paper proposes a new method of measuring an air interface distance between a solid immersion lens(SIL) applied magneto-optic technology and the disk surface. For applying near-field recording (NFR) technology to the magneto-optic storage devices for the next generation, it is positively necessary to maintain the small air gap under about 100㎚. We design an apparatus that consists of some optical components such as a prism, a polarizer and an analyzer. By using the Fresnel reflection coefficient equation, Jones matrices calculation and Malus's law, we establish a mathematical model for understanding the characteristics of the system. The simulations are based on the mathematical model and through the simulation results which is made with various cases we can estimate the performance of the new optical gap sensor system. Experimental results, which are also based on the mathematical model for specific cases, are in good agreement with simulated ones and demonstrate the possibility as the new optical gap sensor.

Thermal Transport Phenomena in the FET Typed MWCNT Gas Sensor with the 60 μm Electrode Distance (60 μm의 전극 간극을 갖는 FET식 MWCNT 가스센서에서 열 유동 현상)

  • Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.403-407
    • /
    • 2015
  • Generally, MWCNT, with thermal, chemical and electrical superiority, is manufactured with CVD (chemical vapor deposition). Using MWCNT, it is comonly used as gas sensor of MOS-FET structure. In this study, in order to repeatedly detect gases, the author had to effectively eliminate gases absorbed in a MWCNT sensor. So as to eliminate gases absorbed in a MWCNT sensor, the sensor was applied heat of 423[K], and in order to observe how the applied heat was diffused within the sensor, the author interpreted the diffusion process of heat, using COMSOL interpretation program. In order to interpret the diffusion process of heat, the author progressed modeling with the structure of MWCNT gas sensor in 2-dimension, and defining heat transfer velocity($u={\Delta}T/{\Delta}x$), accorded to governing equation within the sensor, the author proposed heat transfer mechanism.

Development of Intelligent Filler Wire Feeding Device for Improvement of Weld quality (용접부 품질향상을 위한 지능형 용접 와이어 공급 장치 개발)

  • Lee J.S.;Sohn Y.I.;Park K.Y.;Lee K.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.950-955
    • /
    • 2005
  • This paper describes an intelligent filler wire feeding device which can control 3- dimensional seam tracking and the filler wire speed by measuring the gap position and the joint gap width in laser welding. By means of visual sensor controlled filling the missing material into the joint gap and 3 dimensional seam tracking, lineup errors from manufacturing tolerances and the repeatability of lineup jigs and weld robot can be balanced and at an even seam quality which avoids weld defects. In this paper, we assessed weld quality in 2mm sheets of A16061 which had various gap width by using the intelligent filler wire feeding device.

  • PDF

Estimating Void Ratio Changes of a Pre-loading Site Using Bender Elements Sensors (벤더 엘리먼트 센서를 이용한 선행 재하공법 현장의 간극비 변화 추정)

  • Kim, Hak-Sung;Jung, Young-Hoon;Kim, Byung-Chul;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1110-1116
    • /
    • 2010
  • Void ratios are one of the key parameters for exact calculation of settlement of soft groundse. In the study, shear wave velocities of a soft ground were used to measure the field void ratio using bender elements sensors. The bender-element probes were installed in situ at the depths of 3, 5 and 8m on a pre-loading site near Incheon, Korea. During 90 days after installation, the changes of shear wave velocity and ground surface settlement were measured. The field void ratio was estimated from measured shear wave velocities. The void ratio estimated by the shear wave velocity measured by bender elements agrees well with the measured values in the field.

  • PDF

Design and Kinematic Analysis of the Reticle Stage for Lithography Using VCM (VCM을 이용한 리소그래피용 레티클 스테이지의 설계 및 기구학적 해석)

  • Oh, Min-Taek;Kim, Mun-Su;Kim, Jung-Han
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.86-93
    • /
    • 2008
  • This paper presents a design of the reticle stage for lithography using VCM(Voice Coil Motor) and kinematic analysis. The stage has three axes for X,Y,${\theta}_z$, those actuated by three VCM's individually. The reticle stage has cross coupled relations between X,Y,${\theta}_z$ axes, and the closed solution of the forward/inverse kinematics were solved to get an accurate reference position. The reticle stage for lithography was designed for reaching both high accuracy and long stroke, which was $0.1{\mu}m$ (X,Y)/ $1{\mu}rad({\theta}_z)$ accuracies and relatively long strokes about 2mm (X,Y) and 2 degrees(${\theta}_z$). Also this research presents a rotational compensation algorithm for the precision gap sensor for the stage. Simulation results show the overall performance of the whole algorithm and the improvement quantity of the rotational compensation algorithm.

Improvement in Underground Facilities Management Process ; Focused on the District Heating Facility (지하시설물 유지관리 업무프로세스 개선 방향에 관한 연구 ; 지역난방 시설을 중심으로)

  • Kim, Jung-Hoon;Lim, Si-Yeong
    • Spatial Information Research
    • /
    • v.17 no.3
    • /
    • pp.319-328
    • /
    • 2009
  • The growth of sensor and wireless communication technology enable us to monitor the status of things in real-time. There are many attempts to apply the real-time monitoring in various fields. Especially, the real-time monitoring in facility management fields has attracted much attentions recently. But it is difficult to apply recent technologies including sensor, wireless communication and Geospatial information technologies, etc, to the real situation directly. One of the reasons is that facility managers who are familiar with existing processes may resist the change induced by new technologies. So it is necessary to close the gap between new technologies and existing processes by improving the existing processes prior to putting them in the field. In this paper, we suggest the management process improvement focused on the district heating facilities.

  • PDF