• Title/Summary/Keyword: 각도와 거리 설정

Search Result 56, Processing Time 0.022 seconds

The Accuracy of Stereo Digital Camera Photogrammetry (스테레오 디지털 카메라를 이용한 사진측량의 정확도)

  • Kim, Gi-Hong;Youn, Jun-Hee;Park, Ha-Jin
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.6
    • /
    • pp.663-668
    • /
    • 2010
  • In this study a stereo digital camera system was developed. Using this system, we can collect informations such as coordinates, lengths of all objects shown in the photo image just by taking digital photograph in field. This system has the advantage of obtaining stereo images with settled exterior orientation parameters, while the accuracy slightly worsen because in a close range photogrammetry with stereo digital camera system, the base line distance is restricted within about 1m. We took images with various exposure distances and angles to objects for experimental error assessment, and analyzed the affection of image coordinates errors.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

The Anode Heel Effect caused by changing the Angle of X-Ray Tube (X-선관 각도 변경에 따른 Anode Heel Effect)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.435-442
    • /
    • 2016
  • This study was an investigation of the anode heel effect caused by changing the angle of the x-ray tube. We established the following conditions for experimental measurements: 70 kV, 30 mAs, focus-detector distance of 100cm, and a collimator setting of $35{\times}43cm^2$. The measurement points were set up at the center of the collimator and extended to each side in intervals of 3.5cm, with points A1, A2, A3, A4, A5, A6 on the anode side and points C1, C2, C3, C4, C5, C6 on the cathode side. We measured the entrance surface dose from point A6 to point C6 with each point perpendicular to an x-ray tube. And we did the same when measuring different angles of the x-ray tube from 15 to 30 degrees for every point on the anode and cathode sides. Using perpendicular x-ray tube, we found that the entrance surface dose of the A5 point was three times higher than that of the C5 point. Thus, we conclude that if the anode side is placed near highly radiosensitive organs, then there will be less radiation exposure when using a perpendicular x-ray tube. When imaging using x-ray tube angles, an angle to the cathode side can reduce the gap of the entrance surface dose on both the anode and cathode sides. When imaging areas where there are differences in thickness between the upper and lower sides, the angle to the cathode side that is closer to the thicker area can reduce the gap of the entrance surface dose and capture a higher quality image.

Development of an Optical Range Finder for Surface Roughness Measurements (표면 요철 측정을 위한 광학적 거리 측정기 개발)

  • Eom, Jung-Hyun;Park, Hyun-Hee;Seo, Dong-Sun;Huh, Woong;Kim, Joon-Bum;Kim, Yon-Gon
    • Journal of IKEEE
    • /
    • v.2 no.1 s.2
    • /
    • pp.53-60
    • /
    • 1998
  • We develope a high repetition rate, short distance, optical range finder for surface roughness measurements of large structures, such as a highway road, etc. For range measurement based on a triangulation principle, we use a light emitting diode and an one dimensional Position sensitive photodetector for a light source and an angle detector of the reflected light at the object, respectively. The range finder has automatic power control and electrical background noise rejection capabilities which enable it to overcome variations of an object reflectance and to eliminate time-varying, as well as constant, background light noises. Our experimental results show less than ${\pm}1.5mm$ of measurement errors regardless of an object reflectance, for $22{\sim}38cm$ object ranges which are determined by considering the installation of the range finder and the depth of surface roughness.

  • PDF

Determination of the Required Minimum Spacing between Signalized Intersections and Bus-Bays (신호교차로와 버스정류장간 이격거리 산정에 관한 연구)

  • 하태준;박제진;임혜영
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.4
    • /
    • pp.73-82
    • /
    • 2002
  • The influence of bus stops near signalized intersections is one of the important factors which cannot be negligible in the analysis of the capacity of signalized intersections. Absence of consideration of bus bay can reduce capacity and increase the time that the stop of buses block other traveling vehicles. This influence is reflected by the bus blockage adjustment factor in KHCM, but the factor does not consider the course of each bus passing the intersection. Particularly, left turn buses have more influence on the capacity than the other buses and require the minimum length of the road for lane changes. All the existing criteria can apply only to arterial roads on which mostly traffic flows are continuous. And the criteria. which can determine the optimum location and the minimum distance between a signalized intersection and a bus bay, is not prepared and the related study is insufficient. Therefore, a theoretical formula is derived in this study being based on the theories which are avaliable to apply to the situation of signalized intersections.

Study on Close Microphone Techniques for Korean Traditional Musical Instruments (Gayageum, Haegeum, Daegeum, and Kkwaenggwari) (국악기 근접 마이크로폰 테크닉스를 위한 연구 (가야금, 해금, 대금, 꽹과리))

  • Han, Je-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.4753-4761
    • /
    • 2013
  • This study recorded the sound of Korean traditional musical instruments by considering the radiation characteristics of traditional Korean musical instruments and setting the diverse mounting angle and distance of microphone. By following recorded results, the study analyzes the optimum position of microphone and the characteristic of timbre through frequency range spectrum and repeated listening. This experiment of study is for technique of close microphone which is used in popular music, therefore it is recorded in the popular music recording studio. The study also suggests the optimum position for the microphone to record, and explains the difference of timbre at different position. The result of study will suggest the best technique of Close Microphone Techniques for Korean Traditional Musical Instruments not only to accurately express the beautiful and unique sound of traditional Korean musical instruments but also to obtain diverse timbre.

Dose Reduction According to Geometric Parameters of Digital Cerebral Angiography (두개부 혈관 조영검사 시 기하학적 특성에 따른 선량 감소 방안)

  • Park, Chan Woo;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.399-406
    • /
    • 2019
  • This study aims to find geometric parameters that the radiologist can change from time to time to reduce dose in angiography examinations. Depending on the geometric characteristics, the values calculated by effective dose were compared, while filming in fluoroscopy mode and Digital subtraction angiography, respectively. The study found that the lower the dose was in FPS mode, the lower the dose was reduced to 30-40%. Doses according to the X-ray angle were measured highest in AP View and lower as the angle went in the head direction. The greater the FOV, the higher the dose was 1.2-1.6 times, and the closer the distance between the X-ray tube and the table, the greater the dose was about 10%. Source-image intensifier distance (SID) get longer to 100 mm, dose of each fluoroscopy and Digital subtraction angiography increase up to 25-30%. In conclusion, various geometric characteristics in angiography examinations are parameters that can be applied by radiographers as frequently as possible, and appropriate geometric properties can be considered and applied in various situations, resulting in appropriate dose reduction.

Comparison of Kinematic Variables Between Elite Golfer and Novice During Golf Putting (골프 퍼팅 시 엘리트와 초보자들의 퍼팅 동작에 따른 운동학적 비교 분석)

  • Park, Jun-Sung;Lim, Young-Tae;Lee, Jae-Woo;Kwon, Moon-Seok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.789-796
    • /
    • 2019
  • The purpose of this study was to compare kinematic variables between elite golfer and novice during golf putting. 23 elite golfers and 19 novice were participated, and SAM Putt was used to collect kinematic variables. To identify main effect and interaction effect, it was performed Two-way Mixed ANOVA at a significant level of a .05. Elite and novice group, follow-through was significantly different and indicated main effect between distance and skill level. Impact, backswing, and loft angle were significantly different and showed main effect between skill level. Also, backswing rhythm and impact timing were significantly different and indicated main effect between skill level. Therefore, minimizing the movement of the wrist and keeping the putting strike rhythm may improve the putting ability.

Change of PAE according to Detector Measurement Method (검출기 측정방법에 따른 PAE값의 변화)

  • Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.307-311
    • /
    • 2010
  • The aim of this study is to investigate PAE, as the result of the test of kVp accuracy, according to detector measurement method. Based on the indicated value of 70kVp, each distance between a focus and a kVp meter was 100cm, 80cm and 60cm and the angle of X-ray tube was set on $5^{\circ},\;10^{\circ},\;15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ}$. Each indicated value, 60kVp, 70kVp, 80kVp, 90kVp and 100 kVp, was used compare Small focus with Large focus. As a result, PAE on the side of cathode was higher than it on the side of anode in the case of 100cm and PAE on the side of anode was higher in the case of 80cm and 60cm. The coefficient rate was stable both the side of cathode and anode in the case of 100cm and it was fluctuated in the case of 80cm and 60cm. PAE in the case of Small focus was higher than Large focus and it was disproportionate to an indicated value. Error rate was in inverse proportion to the indicated value.

Autonomous Navigation Power Wheelchair Using Distance Measurement Sensors and Fuzzy Control (거리측정 센서 스캐닝과 퍼지 제어를 이용한 전동 휠체어 자율주행 시스템)

  • Kim, Kuk-Se;Yang, Sang-Gi;Rasheed, M. Tahir;Ahn, Seong-Soo;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.329-336
    • /
    • 2008
  • Nowadays with advancement in technology and aging society, the number of disabled citizens is increasing. The disabled citizens always need a caretaker for daily life routines especially for mobility. In future, the need is considered to increase more. To reduce the burden from the disabled, various devices for healthcare are introduced using computer technology. The power wheelchair is an important and convenient mobility device. The demand of power wheelchair is increasing for assistance in mobility. In this paper we proposed a robotic wheelchair for mobility aid to reduce the burden from the disabled. The main issue in an autonomous wheelchair is the automatic detection and avoidance of obstacles and going to the pre-designated place. The proposed algorithm detects the obstacles and avoids them to drive the wheelchair to the desired place safely. By this way, the disabled will not always have to worry about paying deep attention to the surroundings and his path.

  • PDF