• Title/Summary/Keyword: 가스 측정 방법

Search Result 823, Processing Time 0.029 seconds

A Study on the Destruction or Removal Efficiency of Toxic Gas Reduction Facilities in Semiconductor and Display Industries (반도체 & 디스플레이 업종에서 사용되는 독성가스 저감시설의 처리효율 측정방법에 관한 연구)

  • Jang, Sung-Su;Han, Jae-Kook;Cho, Hyun-Il;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.88-95
    • /
    • 2017
  • The usage of toxic gas in Korea is increasing in the development of high-tech industries such as semiconductors, displays and solar panels. The recent survey of domestic toxic gas consumption indicates an increase in annual average of 12.4 percent, but it is still focused on usage, and it is negligent in safety and treating the post. In September 2012, an accident occurred in Gu-mi involving hydrofluoric acid leak demonstrates the absence of safety management. Due to the incident, the government, industry and academia have been interested in chemical substances(toxic gas), and the government-led safety management has been established and implemented, but there are still a lot of safety blind spots. The purpose of this study is to develop effective measurement methods for the destruction or removal efficiency of gaseous materials emitted from the Scrubber used in the semiconductor and display industries. Also, this study demonstrated how toxic gas facilities can be applied without error by verification test for the measurement method guideline of the destruction or removal efficiency of the green-house gas reduction facility in the semiconductor and display industries used by the National Institute of Environmental Research and the UNFCCC, and suggested the differentiated measurement methods for toxic gas reduction facilities, and the third party certification for safety facilities is needed to prevent toxic gas accidents.

A Study on the development of gas metering valve system (가스 계량 밸브 시스템의 개발에 관한 연구)

  • Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.4
    • /
    • pp.200-204
    • /
    • 2014
  • LPG is used in the home would have to depend on the provider, because there is no method for measuring the capacitance. In addition, by measuring the gas capacities can not be known because of the LPG gas replacement time and requires an alarm for replacement. In this study, and that the gas capacities to the trusted user and the supplier, in order to know when it is time to change to LPG gas by applying a Hall effect sensor developed a gas capacities measurement the valve system.

A Technical Note on Monitoring Methods for Volcanic Gases (화산가스의 채취 및 분석에 대한 기술보고)

  • Lee, Seungyeol;Lee, Sangchul;Yang, Kyounghee;Jeong, Hoon Young
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.415-429
    • /
    • 2012
  • The monitoring methods for volcanic gases are divided into remote sensing and direct gas sampling approaches. In the remote sensing approach, COSPEC and Li-COR are used to measure $SO_2$ and $CO_2$, respectively, with FT-IR for detection of a range of volcanic gases. However, the remote sensing approach is not applicable to Mt. Baegdu, where the atmospheric contents of volcanic gases are very low as a result of the strong interaction of volcanic gases with the nearby surface water and groundwater. On the other hand, the direct gas sampling approach involves the collection of volcanic gases from volcanic vents or fumaroles and the subsequent laboratory analysis, thus making it possible to measure even very low levels of volcanic gases. The direct sampling approach can be subdivided into the evacuated bottle method and the flow-through bottle method. In applying both methods, sampling bottles typically contain reaction media to trap specific volcanic gases. For example, NaOH solution(Giggenbach bottle), $NH_4OH$ solution, and acid condensates have been experimented for volcanic gas sampling. Once taken from vents and fumaroles, the samples of volcanic gases are pretreated and subsequently analyzed for volcanic gases using GC, IC, HPLC, titrimetry, TOC-IC, or ICP-MS. Recently, there has been the increasing number of evidences on the potential volcanic activity of Mt. Baegdu. However, little technical development has been made for the sampling and analysis of volcanic gases in Korea. In the present work, we reviewed various volcanic gas monitoring methods, and provided the detailed information on the monitoring methods applied to Mt. Baegdu.

A Study on the Development of Remotely CP Potential Measuring Method by using Vehicle (차량을 이용한 원격전위 측정방법 개발에 관한 연구)

  • Ryou, Young-Don;Jo, Young-Do;Kim, Jin-Jun;Seo, Min-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.64-71
    • /
    • 2016
  • According to the urban gas business law, electrical corrosion prevention measures shall be installed to the buried gas pipelines and the pipe-to-soil potentials should be measured at the test box at least once a year. Most of the test boxes installed in urban area are usually located on the road where the vehicle travels, therefore, it is difficult to measure the CP potentials at the test boxes. That is, we need traffic control when carrying out the measurement of the CP potentials on daytime when the traffic is heavy, or we have to measure the potentials in the late night when the traffic is light. To solve these difficulties, we have studied remotely CP potential measuring method by using the patrol car. We have installed solid reference electrodes and data loggers under the test boxes on the site and received the CP potentials from the data loggers when the vehicle moves. It was difficult to send and receive the data because the data logger was located under the ground. We have applied 3 different method including 2 antenna systems to achieve best effective way in receiving the data. We have found the remote CP measuring method by using a car can save more 20 times of measuring time than conventional measuring methods.

Simulation of Exhaust Temperature of Gas Turbine Generator using Operating Data (운전데이터에 의한 가스터빈 발전기의 배기가스온도 계통 모델링 및 시뮬레이션에 관한 연구)

  • 우주희
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.176-180
    • /
    • 1999
  • 미지 플랜트의 인식방법은 크게 두 가지로 나눌 수 있으며, 하나는 연역적 방법으로서 대상 플랜트에 대한 열적·유체 역학적 법칙을 사용하여 물리적으로 모델을 수식화하는 방식이고, 다른 하나는 귀납적 방법으로서 측정된 입출력데이터에 의해 역으로 구조를 찾아가는 방식이다. 본 논문에서는 후자의 방법으로 가스터빈 발전소의 배기가스 온도계통 모델을 구하기 위해 현장에서 운전 데이터를 취득하였다. 그리고 컴퓨터 시뮬레이션을 통해 경험적으로 구현한 모델이 실제 운전데이터와 유사한 특성을 보임을 알 수 있었다. 이렇게 구현된 모델은 향후 발전소용 가스터빈 제어시스템을 새로이 구축하거나 튜닝하고자 할 때 배기가스 온도제어계통을 설계하는데 기초자료로 활용할 수 있다.

  • PDF

Simultaneous Determiniation of Ar/$N_2$Ratios in Groundwater (지하수에 용해된 질소, 아르곤 가스의 동시측정)

  • Kim, Euisik;Roy F. Spalding
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.1
    • /
    • pp.6-9
    • /
    • 1994
  • Previously reported Ar/N$_2$ratios in groundwater have been measured by single ion monitoring (Barnes et al., 1975; Vogel et al., 1981; Mariotti et al., 1988). The detector geometry and flared flight tube in VG Optima isotopic ratio mass spectrometer appeared to be fortuitously aligned for the simultaneous measurement of Ar/N$_2$ratios. Method development included mechanical adjustments to optimize the mass spectrometer for Ar/N$_2$ratio measurements followed by development of a preparation system for the extraction of air-saturated water samples. Samples containing known Ar/N$_2$ratios were used to assess accuracy and precision, and to test the applicability of methods for measurements of aqueous Ar/N$_2$ratios. The results indicated that the prepared air-saturated water samples were almost identical to the predicted Ar/N$_2$ratios (p <0.001). Groundwater samples were collected from on-going research sites, Shelton and Grand Island, Nebraska. Samples from the Grand Island sludge injection site form a lower boundary for worldwide reported Ar/N$_2$ratios. These lower Ar/N$_2$ratios can be explained by the production of nitrogen gas from this site, where denitrification was reported previously.

  • PDF

Estimation of heat release rate of liquid fuels by Oxygen consumption technique (산소 소모법에 의한 액체 연료의 열발생율 평가)

  • 한용식;김명배;최준석
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.31-37
    • /
    • 1998
  • The heat release rate of liquid fuels is estimated by oxygen consumption technique. This method is based on the generalization that the heat release rate of combustion per unit of oxygen consumed are approximately the same for most fuels commonly encountered in fires. The oxygen concentration is measured by analyzer of paramagnetic type. The concentrations of CO2 and CO gas are measured by analyzed of Infra-Rad type. Time delays of analyzers are ignored. Results acqired from measuring techniques of exhaust gas concentrations are compared with each other.

  • PDF

화재현장 연소가스 감지소자 감도성능검증 연구

  • Yu, Song-Hyeon;Choe, Mun-Su;Park, Sang-Tae;Hong, Seong-Ho;Yu, Sang-Pil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.128-129
    • /
    • 2013
  • 화재 현장에는 소방대원의 생명에 위협이 될 수 있는 다양한 연소가스가 발생하며, 소방대원의 안전에 다양한 연소가스의 농도를 실시간으로 측정하는 것은 매우 중요하다. 현재 무선통신 기술의 발달과 센서 기술의 발전으로 저전력, 소형의 센서를 이용하여 무선으로 화재현장의 온습도조건, 발생가스의 농도, 소방대원의 생체신호를 화재현장의 지휘센터로 보내주는 기술의 개발이 진행되고 있다. 이러한 추세에 맞추어 측정된 가스의 농도를 실시간으로 지휘센터로 송수신하는 기술의 연구가 활발히 진행 중이다. 본 연구는 화재환경에서 주로 발생되는 CO, NO2, NH3를 위주로한 고온의 환경에서 농도를 측정하기 위한 방법에 대한 연구이다.

  • PDF

The Experimental Study for the Smoke Optical Density and Toxic Gases of Sandwich Panel Insulations(Single Chamber Method) (샌드위치패널 단열재의 연기농도 및 연소독성가스에 대한 실험적 연구(연소챔버법))

  • Park, Soo-Young;Lee, Woo-Seok;Yeo, Han-Seung;Im, Hong-Soon
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.26-32
    • /
    • 2006
  • Nowadays in Korea, KS F 2271 has been using for the test of fire safety performance of sandwich panels. Smoke toxicity test is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice; however this method is not a quantitative way. This test result can be influenced by the health status of mice and test condition. Specific optical density can be quantitatively measured by ISO 5659-2 single chamber method and toxic gases can be quantitatively measured by FTIR analysis. In this study, specific optical density of sandwich panel insulations, which are widely used in Korea, were tested using the ISO 5659-2 single chamber test method and compared with each test. Also, in the second test of three tests for each specimen, FTIR analysis was performed and quantitative test results(HCl, $NO_2$, etc) were compared with each test result.

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.

  • PDF