Browse > Article

The Experimental Study for the Smoke Optical Density and Toxic Gases of Sandwich Panel Insulations(Single Chamber Method)  

Park, Soo-Young (방재시험연구원)
Lee, Woo-Seok (방재시험연구원)
Yeo, Han-Seung (방재시험연구원)
Im, Hong-Soon (방재시험연구원)
Publication Information
Fire Science and Engineering / v.20, no.4, 2006 , pp. 26-32 More about this Journal
Abstract
Nowadays in Korea, KS F 2271 has been using for the test of fire safety performance of sandwich panels. Smoke toxicity test is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice; however this method is not a quantitative way. This test result can be influenced by the health status of mice and test condition. Specific optical density can be quantitatively measured by ISO 5659-2 single chamber method and toxic gases can be quantitatively measured by FTIR analysis. In this study, specific optical density of sandwich panel insulations, which are widely used in Korea, were tested using the ISO 5659-2 single chamber test method and compared with each test. Also, in the second test of three tests for each specimen, FTIR analysis was performed and quantitative test results(HCl, $NO_2$, etc) were compared with each test result.
Keywords
Sandwich panel insulation; ISO 5659-2 single chamber test; Specific optical density; Toxic gases; FTP Code;
Citations & Related Records
연도 인용수 순위
  • Reference
1 FTP Code, International Code for Appoication of Fire Test Procedures, Res.MSC.61(67)
2 화재연소생성물의 독성, 일본 화재연소생성물 독성조사연구위원회, 소화 62
3 ISO 5659-2, Plastics - Smoke Generation - Part 2 : Determination of Optical Density by a Single Chamber Test, ISO(2002)
4 방화재료팜플랫, 일본건설재료학회(1993)
5 KS M ISO 5659-2, 플라스틱-연기발생-제2부 : 단일 전소 체임버 시험에 의한 광학밀도의 측정, 한국표준협회(2002)
6 KS F 2271, 건축물의 내장재료 및 구조의 난연성 시험방법, 한국표준협회(1998)