• Title/Summary/Keyword: 가스측정시스템

Search Result 475, Processing Time 0.025 seconds

Evaluation of Freshness of Chicken Meat during Cold Storage Using a Portable Electronic Nose (휴대용 전자코를 이용한 계육의 냉장 중 신선도 평가)

  • Lee, Hoon-Soo;Chung, Chang-Ho;Kim, Ki-Bok;Cho, Byoung-Kwan
    • Food Science of Animal Resources
    • /
    • v.30 no.2
    • /
    • pp.313-320
    • /
    • 2010
  • The purpose of this study was to evaluate the freshness of chicken meat during 19 d of storage at $4^{\circ}C$ using a portable electronic nose. The portable system consisted of six different metal oxide sensors and a moisture sensor. Determination of volatile compounds with gas chromatography-mass spectrometry, total bacterial count (TBC), and 2-thiobarbituric acid reactive substances (TBARS) monitored the quality change of the samples. These results were compared with the results measured by the electronic nose system. TBC and TBARS measurements could be separated into five groups and seven groups, respectively, among ten groups. According to principal component analysis and linear discriminant analysis with the signals of the portable electronic nose, the sample groups could be clearly separated into eight groups and nine groups, respectively, among ten groups. The portable electronic nose demonstrated potential for evaluating freshness of stored chicken.

Effects of Non-ionic Surfactant Tween 80 on the in vitro Gas Production, Dry Matter Digestibility, Enzyme Activity and Microbial Growth Rate by Rumen Mixed Microorganisms (비이온성 계면활성제 Tween 80의 첨가가 반추위 혼합 미생물에 의한 in vitro 가스발생량, 건물소화율, 효소활력 및 미생물 성장율에 미치는 영향)

  • Lee, Shin-Ja;Kim, Wan-Young;Moon, Yea-Hwang;Kim, Hyeon-Shup;Kim, Kyoung-Hoon;Ha, Jong-Kyu;Lee, Sung-Sil
    • Journal of Life Science
    • /
    • v.17 no.12
    • /
    • pp.1660-1668
    • /
    • 2007
  • The non-ionic surfactant (NIS) Tween 80 was evaluated for its ability to influence invitro cumulative gas production, dry matter digestibility, cellulolytic enzyme activities, anaerobic microbial growth rates, and adhesion to substrates by mixed rumen microorganisms on rice straw, alfalfa hay, cellulose filter paper and tall fescue hay. The addition of NIS Tween 80 at a level of 0.05% increased significantly (P<0.05) in vitro DM digestibility, cumulative gas production, microbial growth rate and cellulolytic enzyme activity from all of substrates used in this study. In vitro cumulative gas production from the NIS-treated substrates; rice straw, alfalfa hay, filter paper and tall fescue hay was significantly (P<0.05) improved by 274.8, 235.2, 231.1 and 719.5% compared with the control, when substrates were incubated for 48 hr in vitro. The addition of 0.05% NIS Tween 80 to cultures growing on alfalfa hay resulted in a significant increase in CMCase (38.1%), xylanase (121.4%), Avicelase (not changed) and amylase (38.2%) activities after 36 h incubation. These results indicated that the addition of 0.05% Tween 80 could greatly stimulate the release of some kinds of cellulolytic enzymes without decreasing cell growth rate in contrast to trends reported with aerobic microorganism. Our SEM observation showed that NIS Tween. 80 did not influence the microbial adhesion to substrates used in the study. Present data clearly show that improved gas production, DM digestibility and cellulolytic enzyme activity by Tween 80 is not due to increased bacterial adhesion on the substrates.

Study on the channel of bipolar plate for PEM fuel cell (고분자 전해질 연료전지용 바이폴라 플레이트의 유로 연구)

  • Ahn Bum Jong;Ko Jae-Churl;Jo Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.15-27
    • /
    • 2004
  • The purpose of this paper is to improve the performance of Polymer electrolyte fuel cell(PEMFC) by studying the channel dimension of bipolar plates using commercial CFD program 'Fluent'. Simulations are done ranging from 0.5 to 3.0mm for different size in order to find the channel size which shoves the highst hydrogen consumption. The results showed that the smaller channel width, land width, channel depth, the higher hydrogen consumption in anode. When channel width is increased, the pressure drop in channel is decreased because total channel length Is decreased, and when land width is increased, the net hydrogen consumption is decreased because hydrogen is diffused under the land width. It is also found that the influence of hydrogen consumption is larger at different channel width than it at different land width. The change of hydrogen consumption with different channel depth isn't as large as it with different channel width, but channel depth has to be small as can as it does because it has influence on the volume of bipolar plates. however the hydrogen utilization among the channel sizes more than 1.0mm which can be machined in reality is the most at channel width 1.0, land width 1.0, channel depth 0.5mm and considered as optimum channel size. The fuel cell combined with 2cm${\times}$2cm diagonal or serpentine type flow field and MEA(Membrane Electrode Assembly) is tested using 100W PEMFC test station to confirm that the channel size studied in simulation. The results showed that diagonal and serpentine flow field have similarly high OCV and current density of diagonal (low field is higher($2-40mA/m^2$) than that of serpentine flow field under 0.6 voltage, but the current density of serpentine type has higher performance($5-10mA/m^2$) than that of diagonal flow field under 0.7-0.8 voltage.

  • PDF

Analysis of Spatial and Vertical Variability of Environmental Parameters in a Greenhouse and Comparison of Carbon Dioxide Concentration in Two Different Types of Greenhouses (온실 환경요인의 공간적 및 수직적 특성 분석과 온실 종류에 따른 이산화탄소 농도 비교)

  • Jeong, Young Ae;Jang, Dong Cheol;Kwon, Jin Kyung;Kim, Dae Hyun;Choi, Eun Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This study was aimed to investigate spatial and vertical characteristics of greenhouse environments according to the location of the environmental sensors, and to investigate the correlations between temperature, light intensity, and carbon dioxide (CO2) concentration according to the type of greenhouse. Temperature, relative humidity (RH), CO2, and light sensors were installed in the four-different vertical positions of the whole canopy as well as ground and roof space at the five spatial locations of the Venlo greenhouse. Also, correlations between temperature, light intensity, and CO2 concentration in Venlo and semi-closed greenhouses were analyzed using the Curve Expert Professional program. The deviations among the spatial locations were larger in the CO2 concentration than other environmental factors in the Venlo greenhouse. The average CO2 concentration ranged from 465 to 761 µmol·mol-1 with the highest value (646 µmol·mol-1) at the Middle End (4ME) close to the main pipe (50Ø) of the liquefied CO2 gas supply and lowest (436 µmol·mol-1) at the Left Middle (5LM). The deviation among the vertical positions was greater in temperature and relative humidity than other environments. The time zone with the largest deviation in average temperature was 2 p.m. with the highest temperature (26.51℃) at the Upper Air (UA) and the lowest temperature (25.62℃) at the Lower Canopy (LC). The time zone with the largest deviation in average RH was 1 p.m. with the highest RH (76.90%) at the LC and the lowest RH (71.74%) at the UA. The highest average CO2 concentration at each hour was Roof Air (RF) and Ground (GD). The coefficient of correlations between temperature, light intensity, and CO2 concentration were 0.07 for semi-closed greenhouse and 0.66 for Venlo greenhouse. All the results indicate that while the CO2 concentration in the greenhouse needs to be analyzed in the spatial locations, temperature and humidity needs to be analyzed in the vertical positions of canopy. The target CO2 fertilization concentration for the semi-closed greenhouse with low ventilation rate should be different from that of general greenhouses.

Effect of Ventilating System on the Performance of Broiler Chicks in an Environmental Controlled Cage House (무창계사의 환기 시스템이 케이지 사육 육계의 초기 생산성에 미치는 영향)

  • HwangBo J.;Hong E.C.;Lee B.S.;Bae H.D.;Lee S.J.;Cho S.B.;Kim H.K.;Kim J.H.;Park B.S.;Song J.I.
    • Korean Journal of Poultry Science
    • /
    • v.33 no.1
    • /
    • pp.57-63
    • /
    • 2006
  • This study was conducted to investigate the effect of ventilating system of environmental controlled broiler house on broiler production. Three hundred eighty four broiler chicks (Hubbard, mean live weight of $44.5{\pm}2.0g/bird$) were reared for 2 wk. The results of the present study were summarized as follows : 1. Ammonia gas production was lower in the second and the third floors of cages compared with first floor of cages 13.5 and 13.5 vs 14.6 ppm, respectively). The observations of ammonia production in the morning and afternoon were similar. The production of carbon dioxide was not different between morning and afternoon, but it was tended to decrease in the forth floor of cages due to a fresh air 2. A wind velocity in the enclosed house was similar across lower, middle and upper section (0.57m/sec, 0.22m/sec and 0.04msec, respectively). In order to maintain an optimal air flow velocity in the cages, the duct entrance was punched, and then the air flow was full-round in the overall space in the cage. 3. Daily liveweight gain, feed intakes, and feed efficiency were not significant differences among treatments during whole experimental period (P>0.05). Therefore, the present results showed that temperature, moisture and atmosphere controlling were desirable, and air flew evenly in the cage.

The Construction and Application of Planning Support System for the Sustainable Urban Development (지속가능한 도시개발을 위한 계획지원시스템의 구축과 활용에 관한 연구)

  • Lee, Hee-Yeon
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.1 s.118
    • /
    • pp.133-155
    • /
    • 2007
  • The sustainable urban development has emerged as a new paradigm of urban studies in recent years. A review of the literature of land use and transport policies in relation to sustainable development reveals a consensus that the main objectives of sustainable strategy should decrease the numbers and length of journeys, and change the land use pattern towards mixed use and high density. However, there is a lack of empirical research as to what types of policies might influence effectively the reduction in the energy consumption and emission of $CO_2$. in order to sustain urban development. This paper tries to construct the conceptual structure of the PSS(planning support system), which is designed to the simulation of the probable effects of policies and planning of different kinds in cities, and evaluate the sustainablilty level according to construct the structure of the PSS(planning support system), which is designed to the simulation of the probable effects of policies and planning of different kinds in cities, and evaluate the sustainablilty level according to the alternative scenarios. The PSS is composed of three components (input-modeling-output). The core of PSS is integrating land use-transport-environment modeling. The advantages of integrating land use-transport-environment modeling are well known, but there are very few such integrated modeling packages in practice. So this paper tries to apply TRANUS software, which is an integrated land use and transport model. The TRANUS system was calibrated to city of Yongin for the base year. The purpose of the application of TRANUS to Yongin is to examine the operability of TRANUS system in Korea. From the outputs and results of operating the system, TRANUS may be effectively used to evaluate the effects of alternative sustainable urban development policies, since sustainablilty indicators can be extracted from several aspects such as land use consumption, total trips, distance and cost, energy consumption, ratio of transport split.

Evaluation of Thermal Catalytic Decomposition of Chlorinated Hydrocarbons and Catalyst-Poison Effect by Sulfur Compound (염소계 탄화수소의 열촉매 분해와 황화합물에 의한 촉매독 영향 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Yang, Chang-Hee;Kim, Mo-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.577-583
    • /
    • 2007
  • To overcome certain disadvantages of past typical control techniques for toxic contaminants emitted from various industrial processes, the current study was conducted to establish a thermal catalytic system using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst and to evaluate catalytic thermal destruction of five chlorinated hydrocarbons[chlorobenzene(CHB), chloroform(CHF), perchloroethylene (PCE), 1,1,1-trichloroethane(TCEthane), trichloroethylene(TCE)]. In addition, this study evaluated the catalyst poison effect on the catalytic thermal destruction. Three operating parameters tested for the thermal catalyst system included the inlet concentrations, the incineration temperature, and the residence time in the catalyst system. The thermal decomposition efficiency decreased from the highest value of 100% to the lowest value of almost 0%(CHB) as the input concentration increased, depending upon the type of chlorinated compounds. The destruction efficiencies of the four target compounds, except for TCEthane, increased upto almost 100% as the reaction temperature increased, whereas the destruction efficiency for TCEthane did not significantly vary. For the target compounds except for TCEthane, the catalytic destruction efficiencies increased up to 30% to 97% as the residence time increased from 10 sec to 60 sec, but the increase of destruction efficiency for TCEthane stopped at the residence time of 30 sec, suggesting that long residence times are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Conclusively, the current findings suggest that when applying the transition-metal catalyst for the better destruction of chlorinated hydrocarbons, VOC type should be considered, along with their inlet concentrations, and reaction temperature and residence time in catalytic system. Meanwhile, the addition of high methyl sulfide(1.8 ppm) caused a drop of 0 to 50% in the removal efficiencies of the target compounds, whereas the addition of low methyl sulfide (0.1 ppm), which is lower than the concentrations of sulfur compounds measured in typical industrial emissions, did not cause.

Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types (축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가)

  • Kim, K.Y.;Choi, H.L.;Ko, H.J.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.283-294
    • /
    • 2004
  • Air quality in the livestock waste compost pilot plant at the Colligate Livestock Station was assessed to quantity the emissions of aerial contaminants and evaluate the degree of correlation between them for different operation strategies; with the ventilation types and agitation of compost pile, in this study. The parameters analyzed to reflect the level of air quality in the livestock waste compost pilot plant were the gaseous contaminants; ammonia, hydrogen sulfide, and odor concentration, the particulate contaminants; inhalable dust and respirable dust, and the biological contaminants; total airborne bacteria and fungi. The mean concentrations of ammonia, hydrogen sulfide, and odor concentration in the compost pilot plant without agitation were 2.45ppm, 19.96ppb, and 15.8 when it was naturally ventilated, and 7.61ppm, 31.36ppb, and 30.2 when mechanically ventilated. Those with agitation were 5.50ppm, 14.69ppb, and 46.4 when naturally ventilated, and 30.12ppm, 39.91ppb, and 205.5 when mechanically ventilated. The mean concentrations of inhalable and respirable dust in the compost pilot plant without agitation were 368.6${\mu}g$/$m^3$ and 96.0${\mu}g$/$m^3$ with natural ventilation, and 283.9${\mu}g$/$m^3$ and 119.5${\mu}g$/$m^3$ with mechanical ventilation. They were also observed with agitation to 208.7${\mu}g$/$m^3$ and 139.8${\mu}g$/$m^3$ with natural ventilation, and 209.2${\mu}g$/$m^3$ and 131.7${\mu}g$/$m^3$ with mechanical ventilation. Averaged concentrations of total airborne bacteria and fungi in the compost pilot plant without agitation were observed to 28,673cfu/$m^3$ and 22,507cfu/$m^3$ with natural ventilation, and 7,462cfu/$m^3$ and 3,228cfu/$m^3$ with mechanical ventilation. They were also observed with agitation to 19,592cfu/$m^3$ and 26,376cfu/$m^3$ with the natural ventilation, and 18,645cfu/$m^3$ and 24,581cfu/$m^3$ with the mechanical ventilation. It showed that the emission rates of gaseous pollutants, such as ammonia, hydrogen sulfide, and odor concentration, in the compost pilot plant operated with the mechanical ventilation and with the agitation of compost pile were higher than those with the natural ventilation and without the agitation. While the concentrations of inhalable dust and total airborne bacteria in the compost pilot plant with the natural ventilation and with the agitation, the concentrations of respirable dust and total airborne fungi in the compost pilot plant with the mechanical ventilation and agitation were higher than those with the natural ventilation and without the agitation of compost pile. It was statistically proved that indoor temperature and relative humidity affected the release of particulates and biological pollutants, and ammonia and hydrogen sulfide were believed primary malodorous compounds emitted from the compost pilot plant.

DNA damages with Fpg/Endo Ⅲ FLARE Assay in cynomolgus monkeys exposed to stainless steel welding fume (용접흄 흡입노출 영장류에서 Fpg/Endo Ⅲ FLARE Assay를 이용한 DNA 손상 및 회복)

  • Rim, Kyung Taek;Kim, Soo Jin;Chung, Yong Hyun;Kim, Hyeon Yeong;Maeng, Seung Hee;Yu, Il Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.272-281
    • /
    • 2007
  • 선박제조업을 비롯한 운송업 및 건축업 등의 다양한 분야에서 용접기술이 이용되어 옴에 따라 용접근로자들에 대한 산업보건학적 관심이 높아지고 있다. 노출정도가 다양하기는 하지만 용접흄은 6가 크롬을 비롯한 금속화합물과 유해가스, 화학물질 등을 복합적으로 포함하고 있는 스테인레스 스틸 용접흄에 대한 유전독성영향을 평가하기 위하여 흡입챔버를 이용, 실험동물인 영장류에 스테인레스 스틸 용접흄을 노출시키고 혈액 내 lymphocytes에 생성된 용접흄 노출농도 및 시간별 DNA 손상정도 및 그 회복효소를 측정함으로써, 유해성이 완전하게 확인되지 않은 용접흄에 노출되어 나타날 수 있는 암을 비롯한 심각한 건강영향을 예방하기 위한 각 지표들을 찾아 그 유용성을 비교하고자 하였다. 영장류를 노출시키기 위해 robotic arm을 장치한 영장류 흡입노출 시스템을 개발하였으며, 이 노출 시스템을 이용하여 수컷 영장류 6마리에 대해 용접흄 노출시험을 실시하였는데 실험군은 대조군 2, 저농도 ($31mg/m^3$) 노출군 2, 고농도 ($63mg/m^3$) 노출군 2마리로 구성하였고, 1일 2시간씩 일주일에 5일 동안 용접흄에 노출시켰다. 노출 농도는 지속적으로 모니터링 하였고, 노출과정 중에 영장류의 혈액을 채취하여 lymphocytes를 분리, 단세포 DNA 손상을 선별하기 위해 DNA 손상회복 효소인 E. coli formamidopyrimidine-DNA glycosylase (Fpg)와 endonuclease Ⅲ (Thymine Glycol-DNA glycosylase) 투여와 Comet asaay (single cell gel electrophoresis, 단세포겔전기영동기법)를 결합시켜 이용하는 Fpg/Endo III FLARE 분석법을 사용하였다. Fpg enzyme에 의한 olive tail moment값의 변화는 16주 노출군부터 노출부검(34주)군 까지 노출농도가 높아짐에 따른 olive tail moment 기하평균 값의 양 반응관계를 보기는 어렵지만, 고농도군의 경우 27주 노출군에서 가장 높은 olive tail moment 값을 보이고 이후 차츰 감소하였다. 한편 16주에서 22주까지의 노출기간에서는 대조군에 비해 노출군에서 DNA손상정도(olive tail moment값)는 모두 유의하게 높았으나, 6, 12, 18, 25, 31, 33, 35주간 노출하였을 때는 다른 결과를 보였다. 각 실험군의 Fpg enzyme에 의한 tail length값의 분포를 살펴볼 때, 저농도군 및 고농도군에서 27주간 노출하였을 때 가장 높은 tail length 값을 보이고 이후 차츰 감소하는 경향을 보였다. 또한 16, 22주간 노출하였을 때 대조군에 비해 노출군에서 tail length 값이 유의하게 높았으나, 20주간에서만 양 반응관계가 관찰되었고, 다른 주간에서는 양 반응 및 기간 반응관계를 나타내지는 않았다. Endo III enzyme에 의한 olive tail moment값의 변화는 기간별 노출군에서 대조군에 비해 높은 DNA손상정도(olive tail moment값)를 나타내는 결과들이 있었지만, 10, 12, 16, 22, 25, 31주간 노출하였을 때 등 상당수 노출기간에서 반응관계를 나타내지는 않았다. 각 실험군의 Endo III enzyme에 의한 tail length값의 분포를 살펴볼 때, 18, 20, 27, 33주간 노출하였을 때 대조군에 비해 노출군에서 tail length 값이 조금 높았지만, 양 반응 및 기간 반응관계를 보이지 않았고 수치의 크기가 불규칙하게 변화하였다. 즉, DNA에 있어 산화된 pyrimidine을 형성하여 손상된 부위의 염기를 제거함으로써 AP site (abasic site)를 만들고 이들이 Comet assay를 통해 break로 전환된 것을 포함한 DNA손상을 측정하기 위하여 endonuclease III (Endo III)를 첨가시킨 Endo III FLARE 분석법을 실시한 결과, 본 연구에서 나타난 결과는 용접흄 노출 영장류에서 Olive tail moment 및 tail length 공히 노출량 및 노출기간 반응관계를 볼 수 없었다. Endo III FLARE 분석법을 통한 산화적 DNA 손상지표는 영장류에 적용하기에는 적응반응현상으로 대조군과 유의한 차이도 관찰할 수 없었고 더욱이 역으로 대조군에서의 자연발생적 수치가 더 높아질 수 있어 용접흄 노출 영장류의 모니터링 지표로 사용하기에는 제한점이 있었다.

Characteristics of Seepage Water and Groundwater in a Coastal LPG Storage Cavern of Jeonnam (전남 해안 LPG 저장공동 유출수와 주변 지하수의 수질특성)

  • Lee, Jin-Yong;Choi, Mi-Jung;Kim, Hyun-Jung;Cho, Byung-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.4
    • /
    • pp.33-44
    • /
    • 2009
  • Water curtain of an underground LPG storage cavern is a facility to prevent leakage of high pressure gases, for which groundwater should flow freely towards the cavern and groundwater level also must be stably maintained. In this study, in order to evaluate qualities of seepage water and surrounding groundwater of an underground LPG storage cavern in Yeosu, 4 rounds of samplings, field measurements and laboratory analyses (February, May, August, October of 2007) were conducted. According to field measurements, pH was weak acidic to neutral but it gradually increased with time. Electrical conductivity (EC) of groundwater near a salt stack showed very high values between 10.47 and 38.50 mS/cm. Dissolved oxygen (DO) showed a very wide range of 0.20~8.74 mg/L and a mean of oxidation-reduction potential (ORP) was 159 mV, which indicated an oxidized condition. Levels of $Fe^{2+}$ and $Mn^{2+}$ were mostly less than 3 mg/L. All of seepage waters showed a Na-Cl type while only groundwater near the salt stack showed a Na-Cl type with a high total dissolved solid. The other groundwaters exhibited typical $Ca-HCO_3$ types. Levels of aerobic bacteria were mostly very high (573-39,520 CFU/mL). Based on the analyses of these hydrochemistry and biological characteristics, it is concluded that there are no particular problems in groundwater and seepage water, which not causing a trouble in the cavern operation. However, both for control of bio-clogging and for sustainable operation of the water curtain system, a regular hydrochemical and microbiological monitoring is required for the seepage water and surrounding groundwater.