• Title/Summary/Keyword: 가스관련 구조

Search Result 170, Processing Time 0.022 seconds

Shear Wave Velocity Structure Beneath White Island Volcano, New Zealand, from Receiver Function Inversion and H-κ Stacking Methods (수신함수 역산 및 H-κ 중합법을 이용한 뉴질랜드 White Island 화산 하부의 S파 속도구조)

  • Park, Iseul;Kim, Ki Young
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.2
    • /
    • pp.66-73
    • /
    • 2014
  • To estimate the shear-velocity ($v_s$) structure beneath the WIZ station on White Island in New Zealand, we applied receiver function (RF) inversion and H-${\kappa}$ stacking methods to 362 teleseismic events (Mw > 5.5) recorded during April 20, 2007 to September 6, 2013. Using 71 RFs with errors less than 20% after 200 iterative computations, we determined that the depth to Moho of $v_s$ = 4.35 km/s is $24{\pm}1km$ within a 15 km radius of the station. In an 1-d $v_s$ model derived by RF inversions, a 4-km thick low-velocity layer (LVL) at depths of 18 ~ 22 km was identified in the lower crust. This LVL, which is 0.15 km/s slower than the rocks above and below it, may indicate the presence of a deep magma reservoir. The H-${\kappa}$ stacking method yielded an estimate of the depth to the Moho of 24.5 km, which agrees well with the depth determined by RF inversions. The low $v_p/v_s$ ratio of 1.64 may be due to the presence of gas-filled rock or hot crystallizing magma.

The application and development of the Evaluation Indicators in accordance with the Planning Stages of Low-Carbon City -in relevance with the stage of urban planning establishment, design and operation of urban structure, management and maintenance- (저탄소 도시계획의 단계별 평가지표 설정 및 적용 연구 -도시계획 수립, 설계 및 운영, 유지·관리 단계를 중심으로-)

  • Oh, Deog-Seong;Sung, Jae-Wook;Lee, Seo-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4560-4571
    • /
    • 2013
  • Current global issue of climate change is growing and greenhouse gases occur in most cities. To solve the problem of climate change, the city should be changed to low-carbon structure. Low-carbon city planning is a step-by-step plan from the initial establishment, from design and operation of urban structure, to maintenance and management should be considered as an integrated whole process. Under this background, this study evaluated the whole process of low-carbon urban planning ways. For this step, divided into three steps and eight divisions, 30 sub-indicators are derived. Through domestic and foreign cases analysis studies and survey of the relevant experts, results were derived. In order to improve these points, in the intial planning establishment stage, planning of urban policy and institutional steps should be made and the plan should be appropriate to the local characteristics. In the design and operation of urban structure stage, detailed and feasible approach is needed and maintenance and management stage, participation of various stakeholders, including establishing governance and management practices could see the need.

Field Application and Maintenance of sidewalk concrete block for PV Power Generation (태양광 발전을 위한 보도형 콘크리트 블록의 현장 적용과 유지관리)

  • Kim, Bong-Kyun;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.75-83
    • /
    • 2019
  • In order to fulfill the obligation to voluntarily reduce greenhouse gas emissions under the Paris Climate Agreement, the proportion of coal and nuclear power generation is reduced worldwide and national efforts are being made to spread renewable energy including solar power generation. Korea also intends to increase the proportion of renewable energy generation to 30~35% by 2040 by introducing laws and regulations. In addition, while the country is trying to apply solar power generation to sidewalks and roads, there is no research related to it in Korea. Therefore, as a precedent study to develop solar power generation roads, solar power generation concrete blocks applicable to sidewalks and plazas were developed and the applicability was evaluated by constructing them on the site. As a result of indoor experiment, compressive strength was measured by 25.5~35.7MPa and flexural strength was measured by 5.1~10.5MPa, which showed that all domestic standards were satisfied. However, the higher the unit cement amount, the lower the strength was measured according to the mixing of the broken fine aggregate. The absorption rate was 5.7%, which satisfied the domestic standard of 7% or less. As a result of the freeze-thawing test, the reduction rate of the compressive strength after 100 cycles was up to 6.3%. As a result of measuring the settlement amount after construction, the maximum of 2.498mm was measured and irregular settlement occurred in the overall area, which is because the resolution of the sand layer was poor during construction. Maintenance techniques of sidewalk concrete block and solar panel need to be established more efficiently through long-term operation in the further.

Experimental Study on Combined Failure Damage of Bi-directional Prestressed Concrete Panel under Impact-Fire Loading (충돌 후 화재에 대한 이방향 프리스트레스트 콘크리트 패널부재의 복합 파괴손상에 관한 실험적 연구)

  • Yi, Na-Hyun;Lee, Sang-Won;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.429-440
    • /
    • 2014
  • Since the World Trade Center and Pentagon attacks in 2001, terror, military attack, or man-made disaster caused impact, explosion, and fire accident have frequently occured on civil infrastructures. However, structural behavior researches on major Prestressed Concrete (PSC) infrastructures such as bridges, tunnels, Prestressed Concrete Containment Vessel (PCCVs), and LNG tanks under extreme loading are significantly lacking. Especially, researches on possible secondary fire scenarios after terror, bombing, collision of vehicles and vessels on concrete structures have not been performed domestically where most of the past researches related to extreme loadings on structures focused on an independent isolated extreme loading scenario. Due to the outcry of public concerns and anxiety of potential terrorist attacks on major infrastructures and structures, a study is urgently needed at this time. Therefore, in this study, the bi-directional prestressed concrete $1400{\times}1000{\times}300mm$ panels applied with 430 kN prestressing force using unbonded prestressing thread bars were experimentally evaluated under impact, fire, and impact-fire combined loadings. Due to test site restrictions, impact tests were performed with 14 kN impactor with drop heights of 10m and 3.5 m to evaluate impact resistance capacity. Also, fire and impact-fire combined loading were tested using RABT fire loading curve. The measured residual strength capacities of PSC and RC specimens applied with impact, fire, impact-fire combined loadings were compared with the residual strength capacity of undamaged PSC and RC specimens for evaluation. The study results can be used as basic research data for related research areas such as protective design and numerical simulation under extreme loading scenarios.

Experimental Evaluation of Bi-directionally Unbonded Prestressed Concrete Panel Impact-Resistance Behavior under Impact Loading (충돌하중을 받는 이방향 비부착 프리스트레스트 콘크리트 패널부재의 충돌저항성능에 대한 실험적 거동 평가)

  • Yi, Na-Hyun;Lee, Sang-Won;Lee, Seung-Jae;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.485-496
    • /
    • 2013
  • In recent years, frequent terror or military attacks by explosion or impact accidents have occurred. Examplary case of these attacks were World Trade Center collapse and US Department of Defense Pentagon attack on Sept. 11 of 2001. These attacks of the civil infrastructure have induced numerous casualties and property damage, which raised public concerns and anxiety of potential terrorist attacks. However, a existing design procedure for civil infrastructures do not consider a protective design for extreme loading scenario. Also, the extreme loading researches of prestressed concrete (PSC) member, which widely used for nuclear containment vessel, gas tank, bridges, and tunnel, are insufficient due to experimental limitations of loading characteristics. To protect concrete structures against extreme loading such as explosion and impact with high strain rate, understanding of the effect, characteristic, and propagation mechanism of extreme loadings on structures is needed. Therefore, in this paper, to evaluate the impact resistance capacity and its protective performance of bi-directional unbonded prestressed concrete member, impact tests were carried out on $1400mm{\times}1000mm{\times}300mm$ for reinforced concrete (RC), prestressed concrete without rebar (PS), prestressed concrete with rebar (PSR, general PSC) specimens. According to test site conditions, impact tests were performed with 14 kN impactor with drop height of 10 m, 5 m, 4 m for preliminary tests and 3.5 m for main tests. Also, in this study, the procedure, layout, and measurement system of impact tests were established. The impact resistance capacity was measured using crack patterns, damage rates, measuring value such as displacement, acceleration, and residual structural strength. The results can be used as basic research references for related research areas, which include protective design and impact numerical simulation under impact loading.

Deformation History of Precambrian Metamorphic Rocks in the Yeongyang-Uljin Area, Korea (영양-울진 지역 선캠브리아기 변성암류의 변형작용사)

  • Kang Ji-Hoon;Kim Nam Hoon;Park Kye-Hun;Song Yong Sun;Ock Soo-Seok
    • The Journal of the Petrological Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.179-190
    • /
    • 2004
  • Precambrian metamorphic rocks of Yeongyang-Uljin area, which is located in the eastern part of Sobaegsan Massif, Korea, are composed of Pyeonghae, Giseong, Wonnam Formations and Hada leuco granite gneisses. These show a zonal distribution of WNW-ESE trend, and are intruded by Mesozoic igneous rocks and are unconformably overlain by Mesozoic sedimentary rocks. This study clarifies the deformation history of Precambrian metamorphic rocks after the formation of gneissosity or schistosity on the basis of the geometric and kinematic features and the forming sequence of multi-deformed rock structures, and suggests that the geological structures of this area experienced at least four phases of deformation i.e. ductile shear deformation, one deformation before that, at least two deformations after that. (1) The first phase of deformation formed regional foliations and WNW-trending isoclinal folds with subhorizontal axes and steep axial planes dipping to the north. (2) The second phase of deformation occurred by dextral ductile shear deformation of top-to-the east movement, forming stretching lineations of E-W trend, S-C mylonitic structure foliations, and Z-shaped asymmetric folds. (3) The third phase deformation formed I-W trending open- or kink-type recumbent folds with subhorizontal axes and gently dipping axial planes. (4) The fourth phase deformation took place under compression of NNW-SSE direction, forming ENE-WSW trending symmetric open upright folds and asymmetric conjugate kink folds with subhorizontal axes, and conjugate faults thrusting to the both NNW and SSE with drag folds related to it. These four phases of deformation are closely connected with the orientation of regional foliation in the Yeongyang-Uljin area. 1st deformation produced regional foliation striking WNW and steeply dipping to the north, 2nd deformation locally change the strike of regional foliation into N-S direction, and 3rd and 4th deformations locally change dip-angle and dip-direction of regional foliation.

Scheme on Environmental Risk Assessment and Management for Carbon Dioxide Sequestration in Sub-seabed Geological Structures in Korea (이산화탄소 해양 지중저장사업의 환경위해성평가관리 방안)

  • Choi, Tae-Seob;Lee, Jung-Suk;Lee, Kyu-Tae;Park, Young-Gyu;Hwang, Jin-Hwan;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2009
  • Carbon dioxide capture and storage (CCS) technology has been regarded as one of the most possible and practical option to reduce the emission of carbon dioxide ($CO_2$) and consequently to mitigate the climate change. Korean government also have started a 10-year R&D project on $CO_2$ storage in sea-bed geological structure including gas field and deep saline aquifer since 2005. Various relevant researches are carried out to cover the initial survey of suitable geological structure storage site, monitoring of the stored $CO_2$ behavior, basic design of $CO_2$ transport and storage process and the risk assessment and management related to $CO_2$ leakage from engineered and geological processes. Leakage of $CO_2$ to the marine environment can change the chemistry of seawater including the pH and carbonate composition and also influence adversely on the diverse living organisms in ecosystems. Recently, IMO (International Maritime Organization) have developed the risk assessment and management framework for the $CO_2$ sequestration in sub-seabed geological structures (CS-SSGS) and considered the sequestration as a waste management option to mitigate greenhouse gas emissions. This framework for CS-SSGS aims to provide generic guidance to the Contracting Parties to the London Convention and Protocol, in order to characterize the risks to the marine environment from CS-SSGS on a site-specific basis and also to collect the necessary information to develop a management strategy to address uncertainties and any residual risks. The environmental risk assessment (ERA) plan for $CO_2$ storage work should include site selection and characterization, exposure assessment with probable leak scenario, risk assessment from direct and in-direct impact to the living organisms and risk management strategy. Domestic trial of the $CO_2$ capture and sequestration in to the marine geologic formation also should be accomplished through risk management with specified ERA approaches based on the IMO framework. The risk assessment procedure for $CO_2$ marine storage should contain the following components; 1) prediction of leakage probabilities with the reliable leakage scenarios from both engineered and geological part, 2) understanding on physio-chemical fate of $CO_2$ in marine environment especially for the candidate sites, 3) exposure assessment methods for various receptors in marine environments, 4) database production on the toxic effect of $CO_2$ to the ecologically and economically important species, and finally 5) development of surveillance procedures on the environmental changes with adequate monitoring techniques.

  • PDF

Silicon thin films and solar cells by HWCVD (열선 화학 기상 증착법에 의한 실리콘 박막 및 태양전지 특성)

  • Kim Sang-Kyun;Lee Jeong Chul;Jeon Sang Won;Lim Chung Hyun;Ahn Sae Jin;Yun Jae Ho;Kim Seok Ki;Song Jinsoo;Park S-J;Yoon Kyung Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.205-208
    • /
    • 2005
  • 최근 열선 화학 기상 증착법(HWCVD)은 낮은 온도에서 TFT용 Poly Si 중착을 할 수 있다는 점과 실리콘 박막을 빠른 속도로 증착할 수 있다는 점에서 각광을 받고 있다. 본 연구에서는 HWCVD를 이용하여 태양전지를 제조하고 그 특성을 평가하였다. 조건에 따른 실리콘 박막의 특성 변화를 알기 위해 corning glass 및 실리콘 wafer에 다양한 조건에서 단위 박막(intrinsic layer)을 증착하였고 이 결과를 바탕으로 p/i/n 구조의 태양전지를 제조하였다. Ta 열선 온도는 1700-2000도였고 가스 원료인 $SiH_4$와 수소의 비율을 조절하면서 그 영향을 관찰하였다. 태양전지의 경우 p충과 n충은 PECVD로 증착하였으며 단위박막 및 태양전지 i충 증착시 기판과 열선간의 거리는 7cm, 기판 온도는 $200^{\circ}C$$250^{\circ}C$로 고정하였고 작업압력은 30mTorr였다. 단위 박막 특성 평가를 위해 암/광 전도도, SEM, Raman Scattering, FT-IR등을 사용하였으며 태양전지 특성 평가를 위해 I-V 및 Spectral response를 측정하였다. 열선 온도가 증가함에 따라 증착속도 및 결정화 분율은 증가하였다. 특히 비정질에서 결정질로 전이되는 구간은 매우 좁았으며 여러 분석 방법에서 일치되는 결과를 보였다. $SiH_4$ 유량이 늘어날수록 비정질이 결정질로 바뀌는 열선 온도가 증가하였으며 기판 온도가 낮을 경우 또한 결정으로 바뀌는 열선 온도가 증가하였다. 태양전지의 경우 열선 온도가 증가함에 따라 $V_{oc}$ 및 W가 낮아졌으며 $J_{sc}$, 는 증가하는 경향을 보였으며 결정질 비율이 증가하는 것을 관찰할 수 있었다. 이러한 경향은 quantum efficiency 결과에서도 확인할 수 있었다.용을 반복하면서 석재 내부와 외부의 암석 및 결정에 균열과 미세열극 등이 생성되어 석재 자체의 구조적 안정성에 영향을 주고 있다. 따라서 감은사지 석탑은 지리적 환경 차이로 인해 일반적인 환경의 석조물들과는 다른 형태의 풍화양상을 보이고 있어서 풍화양상 및 풍화형태에 대한 정확한 연구와 이해를 바탕으로 보존대책이 마련되어야 한다.되었다. 이런 모든 시편들을 각 탈염방법에 따라 탈염처리한 후 XRD와 SEM-EDS으로 분석한 결과 인철광과 침철광은 어떠한 변화도 보이지 않았고, 다만 적금광으로 동정된 시편만이 잔존하지 않았다. 철기 제작별 $Cl^-$ 이온 추출량과 탈염효과에 대한 비교 실험은 이온 크로마토그래피 분석 결과와 마찬가지로 단조 철제유물이 주조 철제보다 $Cl^-$ 이온을 많이 가지고 있었으며, 탈염 처리 후에는 $Cl^-$ 이온은 전혀 발견되지 않았다. 이상의 결과 $K_2CO_3$와 Sodium 용액은 탈염처리에서 가장 적합한 탈염처리 용액으로 알수가 있었으며 특히 어떠한 탈염 용액으로 유물을 처리한다 해도 철제유물에 생성된 부식물은 제거되지 않는다는 것을 알게 되었다. 따라서 보존처리자는 유물 표면의 부식 상태만을 보고 처리하기 보다는 철기제작물로 고려하여 처리하는 것이 필요하다. 또한 금속에 부식을 야기시키는 $Cl^-$ 이온과 부식물을 완전하게 제거하여 탈염처리를 하는 것이 유물 부식을 최대한 지연시킬 수 있는 것이라 생각된다.TEX>$88\%$)였다.(P=0.063). 결론: 본 연구에서는 MTHFR C/T & T/T 유전자 다형성이 위암의 발생과 그 위치에 대해 관련이 있는 것으로 여겨지고, 흡연력, 음주력과는 관련이 없는 것으로 여겨진다.험이 커지는 경향을 보였으나, 나이 및 병기, 종양의 크기, MD-BED $Gy_{10}$ 등의 예후 인자를 보정한 다변

  • PDF

Development of High Performance Curing Agent and Effective Dispersion Method of Nanomaterials (고성능 피막양생제 개발 및 나노물질의 분산방안 평가)

  • Son, Ho-Jung;Yoo, Byung-Hyun;Lee, Dong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.230-236
    • /
    • 2019
  • Recently, issues related to the quality of concrete have continuously resulted in surface quality problems, such as the exfoliation of concrete surfaces due to the cost reduction of cement and poor quality fine aggregate, scaling of surfaces caused by laitance, and plastic shrinkage cracks. Prompted by social issues, the application of a photo catalyst to road structures is being attempted to solve the environmental problems caused by fine dust and automobile exhaust. In this study, chemical admixtures were developed to improve the surface quality of concrete and to apply and distribute titanium dioxide in nanoscale sizes to provide basic data for the development of a photocatalyst-curing agent. As a result of the experiment, silicon and silane were reviewed as a raw material as a curing agent to develop a high performance curing agent with better film performance than conventional curing agents because they could form a film quickly on a fresh concrete surface. The distributed stability of the ultrasonic disperser showed the best performance through an outdoor test for four weeks to review the dispersion measures for the application of nanomaterials.

PECVD와 고상결정화 방법을 이용한 poly-SiGe 박막의 제조

  • 이정근;이재진
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.55.2-55
    • /
    • 1998
  • 다견정 심리판-거l르마늄(JXlly-SiGe)은 TFT(thin-film transistor)와 갇븐 소자 응용에 있어서 중요한 불칠이다 .. LPCVD (low pressure chemical vapor deposition) 방법으로 비정칠 SiGc (a-SiGe) 박막올 증 착시키고 고상결정화(SPC: solid-phase crystallization)시켜 poly-SiGc옹 얻는 것은 잘 알려져 있다. 그러 나 그러나 PF'||'&'||'pound;VD-SPC 방법올 이용한 poly-SiGc의 제조에 대해서는 아직 두드러지게 연구된 바 없다. 우리단 PF'||'&'||'pound;VD 방법으로 a-SiGc 박막올 증착시키고 고상캘정화시켜 poly-SiGc올 얻었 R며, :~ 결정성, G Gc 농도, 결정핍의 평끌 크기 눔올 XRD (x-ray diffraction) 방법으호 조사하였다. 특히 pr'||'&'||'pound;VD 증착시 가판온도,Gc 함유량 등이 고상화에 미치는 영향에 대해서 조사하였다. P PECVD 장치는 터보펌프콸 사용하여 71저진공이 2xlOlongleftarrow5 Torr에 이르렀다. 가판윤 SiOOO) 웨이퍼륜 사용하고 기판 온도는 약 150- 35()"C 사이에서 변화되었다. 증착가스는 SiH4, GcH4, 112 등흘 썼다. 증착 압력과 r.f 전력용 각각 O.25ToIT와 3W로 일정하게 하였다 .. Gc 함유량(x)은 x x=O.O-O.5 사이에서 변화되었다 .. PECVD모 증착된 SiGc 박막들은 고상결정화를 위해 $\theta$X)"(:: Nz 분위기에서 24시간동안, 혹은 5OO'C에서 4열간 가열되었다. 고상결정화 후 poly-SiGc 박막은 SiGc(Ill), (220), (311) XRD 피크들올 보여주었으며, 각 피 크들은 poly-Si에 비하여 왼쪽으로 Bragg 각이 이동되었고, Vegard’slaw에 의해서 x의 값올 확 인할 수 있었다. 이것온 RBS 결과와 열치하였다. 약 150-350'C 사이에서 변화된 기판온도의 범위 에서 증착온도가 낮올수콕 견정립의 크기는 대체로 증가하는 것으로 나타났다 .. XHD로 추정된 형 균 결정립의 크기는 최대 약 3$\alpha$1m 정도였다. 또한 같끈 샘플뜰에 대해서 기판온도가 낮올수록 증착속도가 증가함옴 확인하였다 .. Gc 함유량이 x=O.1에서 x=O.5로 증가함에 따라서도 결정립의 크기와 SiGc 증착속도는 증가하는 것으로 나타났다 .. Hwang [1] , Kim[2] 둥의 연구자들은 Gc 함유 량이 증가함에 따라 결정 립 크기가 캄소하는 것올 보고하였으냐, Tsai [3] 둥은 반대의 결과플 보 고하고 Ge 힘유량의 증가시 결정립 크기의 증가에 대해 Gc의 Si보다 낮은 융점 (melting point) 올 강조한 바 있다. 결정립 크기의 증가는 대체로 SiGe 중착속도의 증가와도 관련이 있음올 볼 때, poly-SiGc의 경우에도 polv-Si의 고상화에서와 같이 증착속도가 빠를수록 최종적언 결정럽의 크기가 커지는 것으로 이해될 수도 있다 .. PECVD 증착시 증착속도의 증가는 증착된 박딱에서의 무켈서도를 증 가시킬 수 있음올 고려하면, 이라한 결파플온 p이y-SiGc의 고상결정화에서도 ploy-Si의 고상결정 화에서와 마찬가지로 초기 박막에서의 구조직 무절서도가 클수록, 고상결정화 후 결정 립의 크기 가 커칠 수 있음올 보여준다고 생각휠 수 있다,

  • PDF