• Title/Summary/Keyword: 가뭄 대비

Search Result 268, Processing Time 0.031 seconds

The Effect of Drought Simulated by Discharge Control on Water Quality and Benthic Diatom Community in the Indoor Experimental Channel (인공하천에서 유량감소로 모사한 가뭄효과가 수질 및 부착돌말류 군집에 미치는 영향)

  • Park, Hye-Jin;Kim, Baik-Ho;Kong, Dong-Soo;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.1
    • /
    • pp.129-138
    • /
    • 2012
  • We investigated an ecological impact of drought simulated by discharge depletion on the water quality and benthic diatom community in the indoor experimental channel. As artificial substrates slide-glass was installed in acrylic channel for 16 days. Channels were supplied continuously with eutrophic lake water with a discharge rate of 6 L $min^{-1}$ in duplication during the colonized period. And then during the discharge depletion period, three discharge rates were provided: NDF (No depletion of flow rate (Control): 6 L $min^{-1}$), LDF (Low depletion of flow rate: 3 L $min^{-1}$) and HDF (High depletion of flow rate: 1 L $min^{-1}$). Environmental factors in the water, such as suspended solid, Chl-$a$ and nutrients concentration, were measured with periphytic algae including AFDM (ash free dry matter), Chl-$a$ concentration and cell density at 1-day intervals. Light intensity increased significantly with discharge depletion (F=229.5, p= 0.000). $NH_4$-N concentration was highest at HDF. Suspended solid in outflowing water decreased at HDF (88%), LDF (97%) and NDF (99%), compared to inflowing water (100 %). Chl-$a$ in substrates increased more than two times at LDF and HDF than NDF (F= 8.399, p=0.001). Also AFDM and benthic diatom density increased significantly at LDF and HDF than NDF (F=9.390, p=0.001; F=6.088, p=0.007). In all experimental groups, $Aulacoseira$ $ambigua$, $Achnanthes$ $minutissima$ and $Aulacoseira$ $granulata$ were dominant species accounting for greater than 10% of benthic diatom density. The most dominant species, $A.$ $ambigua$ was highest at LDF, followed by HDF and NDF (F=8.551, p=0.001). In conclusion, the effect of drought simulated by discharge depletion in an artificial stream ecosystem caused significant changes on water quality and benthic diatom biomass. This result provides a useful data to understand the effect of draught on stream ecosystem in situ.

Vulnerability assessment on the location of industrial complex considering climate change -Focusing on physical and economic features of province·industrial complex - (산업단지의 입지적 요건을 고려한 기후변화 취약성 평가 - 지자체 및 산업단지의 물리적·경제적 특성에 집중하여 -)

  • Kim, Yoonjung;Lee, Dongkun;Seo, Changwan;Ryu, Jieun;Chae, Yeora;Baek, Gyounghye;Bae, Chae-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.627-637
    • /
    • 2013
  • 기후변화가 산업단지에 미치는 영향은 지자체에까지 확산될 수 있으며 물리적, 경제적인 영향이 미쳐지므로 어떠한 물리적, 경제적 변수에 의해 산업단지의 피해가 초래되는지 규명될 필요가 있다. 따라서 본 연구는 국가 산업단지를 대상으로 산업단지 및 입지 시군구의 물리적, 경제적 특성을 기반으로 한 기후변화 취약성 평가를 수행하고 산업단지 입지에 영향을 미치는 시간, 공간별 극한기후를 규명하고자 하였다. 산업단지의 극한기후에 의한 취약성은 IPCC에서 제안한 상향식 취약성 평가 방법을 따라 분석되었으며 전력요구도, 위험지역유무 등 단지의 물리적 입지조건과 입지 지자체의 기반시설 현황, 지자체와 산업단지의 경제적 특성 등이 평가 기준으로 연구되었다. 기후노출, 민감도, 적응 능력의 항목별 가중치와 항목내 변수들의 가중치 분석에 AHP가 적용되었다. 본 연구는 홍수, 가뭄, 혹서, 혹한, 해수면상승에 대해 취약 입지 시군구를 밝혔고 홍수와 가뭄, 혹서와 혹한별로 대비되는 취약성 결과가 나옴을 고찰하였다. 또한, 각 극한기후별로 적응능력 함양이 시급한 시군구를 밝혀 지자체 차원의 노력이 필요한 시군구를 규명하였다. 서울시 금천구는 산업단지 입지에 가장 취약한 지역으로 나타났으며 홍수, 혹한에서 높은 취약성을 보임이 분석되었다. 한편, 극한기후의 발생에도 불구하고 전반적으로 낮은 취약성을 보인 산업단지 입지 지자체는 광주광역시, 전라북도 익산, 제주시 등으로 분석되었다. 따라서 본 연구는 산업단지의 업종에 따라 적합하지 않은 입지 지역을 규명하였으며 향후 산업단지 입지의 잠재 기후변화 영향을 고려한 의사결정을 지원할 수 있다.

Analysis of groundwater level change using groundwater monitoring network in Miryang area. (지하수관측망을 이용한 밀양지역의 지하수 변화 분석)

  • Baek, Mi Kyung;Sim, Gyu Sung;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.221-221
    • /
    • 2019
  • 기후변화로 인한 가뭄대비가 상시체제가 된 요즈음, 농업용수의 안정적인 공급을 위하여 가뭄 등의 비상시 지표수는 물론이고 지하수의 공급 가능량에 대해서도 국가적 관리가 필요한 실정이다. 지하수관리를 위해 국가 최상위 계획인'지하수관리기본계획(2012~2021)'이 수립되었고, 지하수의 장기적인 수량, 수질 관리를 위해 국가지하수관측망, 지역지하수관측망(보조지하수관측망), 수질측정망, 해수침투관측망 등 광역과 지역단위로 크게 나누어 지하수관측이 이루어지고 있다. 국가지하수관측망은 지하수법에 의거하여 전국의 주요지점(2016년 말 기준 412개소)에 관측소를 설치하여 수위 및 수질의 변동실태를 광역적으로 분석함이 목적이며, 보조지하수관측망은 국가지하수관측망과 연계하고 보완하기 위한 기능으로서, 지역별 주요 관측지점의 수위, 수질자료를 획득하며, 2018년 9월 현재 3,429개소가 설치되어있다. 본 연구에서는 지역지하수 관측망 중 경남밀양지역에 설치된 관측정 31개소에 대해 수위와 수질을 장기 분석하였다. 밀양지역의 보조지하수관측망 설치는 지하수관리계획의 하부계획인'경상남도 지하수관리계획(2015~2025)'에 의거 2012년에 6개소의 관측공이 설치를 시작으로, 2013년 7개소, 2014년 10개소, 2015년 8개소를 설치하여 총 31개소의 설치를 완료하였고, 2016년부터 2019년 현재까지 전체 관측정 31개소에 대하여 관측 운영 중이다. 본 연구에서는 2013년 1월~2019년 1월까지 지역의 누적강수량과 지하수위 및 수질변화를 관측하였다. 전 관측정에 대해 수위(GL.m), 수질(온도, EC)은 1시간 주기로 관측하였으며, 연 2회 생활용수 기준(19항목)의 수질검사를 실시하고, 지하수성분의 지질학적 기원분석을 위한 양음이온 분석을 연 1회 실시하였다. 관측정의 양수능력 변화관측을 위해 대수성 시험을 연 1회 실시하였고, 관측정의 특성상 장기간 미사용 관정이므로 최적의 상태유지를 위해 연1회 공내세척을 실시하였다. 또한, 관측정의 지형별 차이를 분석하기 위해 관측정의 설치위치를 산악, 강변, 기타 지역으로 구분하고, 각각의 대표관정에 대해 지형에 의한 서로 다른 영향을 분석하였고, 관측정의 심도별 변화를 알기위해 동일지역에 충적, 안반 관측정을 따로 설치하고 관측하여 지표수와 지하수의 심도별 영향의 차이를 분석하였다. 동일지역의 관측결과 평균 5m이하의 수위변화를 보이나, 5m 이상의 수위변동을 보이는 관측망은 15년 14개소 17년 19개소로 증가추세를 보이며, 이는 주로 밀집된 시설하우스 단지의 수막재배를 위한 겨울철 지하수 사용량 증가가 원인인 것으로 판단된다. 밀양지역은 강변지역에 밀집된 시설하우스단지의 동절기 수막재배를 위한 지하수 과다사용으로 수위급감 및 수량부족현상이 반복되고 있어, 예방과 대책강구를 위해 지표수의 함양과 지하수사용량의 상관관계 분석과 자료축적 및 추가연구를 위한 장기관측이 요구된다.

  • PDF

Assessment of Water Circulation and Hydro-characteristics with LID techniques in urbanized areas (도시지역에 적용된 LID 기법의 강우시 수문특성 및 물순환 평가)

  • Choi, Hyeseon;Hong, Jungsun;Jeon, Minsu;Geronimo, Franz Kevin;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.191-198
    • /
    • 2019
  • High impervious surfaces increase the surface runoff during rainfall and reduces the underground infiltration thereby leading to water cycle distortion. The distortion of water cycle causes various urban environmental problems such as urban flooding, drought, water pollutant due to non-point pollution runoff, and water ecosystem damage. Climate change intensified seasonal biases in urban rainfall and affected urban microclimate, thereby increasing the intensity and frequency of urban floods and droughts. Low impact development(LID) technology has been applied to various purposes as a technique to reduce urban environmental problems caused by water by restoring the natural water cycle in the city. This study evaluated the contribution of hydrologic characteristics and water cycle recovery after LID application using long-term monitoring results of various LID technology applied in urban areas. Based on the results, the high retention and infiltration rate of the LID facility was found to contribute significantly to peak flow reduction and runoff delay during rainfall. The average runoff reduction effect was more than 60% at the LID facility. The surface area of the LID facility area ratio(SA/CA) was evaluated as an important factor affecting peak flow reduction and runoff delay effect.

An analysis of effects of seasonal weather forecasting on dam reservoir inflow prediction (장기 기상전망이 댐 저수지 유입량 전망에 미치는 영향 분석)

  • Kim, Seon-Ho;Nam, Woo-Sung;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.7
    • /
    • pp.451-461
    • /
    • 2019
  • The dam reservoir inflow prediction is utilized to ensure for water supply and prevent future droughts. In this study, we predicted the dam reservoir inflow and analyzed how seasonal weather forecasting affected the accuracy of the inflow for even multi-purpose dams. The hindcast and forecast of GloSea5 from KMA were used as input for rainfall-runoff models. TANK, ABCD, K-DRUM and PRMS models which have individual characteristics were applied to simulate inflow prediction. The dam reservoir inflow prediction was assessed for the periods of 1996~2009 and 2015~2016 for the hindcast and forecast respectively. The results of assessment showed that the inflow prediction was underestimated by comparing with the observed inflow. If rainfall-runoff models were calibrated appropriately, the characteristics of the models were not vital for accuracy of the inflow prediction. However the accuracy of seasonal weather forecasting, especially precipitation data is highly connected to the accuracy of the dam inflow prediction. It is recommended to consider underestimation of the inflow prediction when it is used for operations. Futhermore, for accuracy enhancement of the predicted dam inflow, it is more effective to focus on improving a seasonal weather forecasting rather than a rainfall-runoff model.

Assessment of climate disaster vulnerability of Gangwon-do based on RCP 8.5 climate change scenario (RCP 8.5 기후변화시나리오 기반 강원도 기후 재난취약성 평가)

  • Lee, Hyeon Ji;Jeung, Se Jin;Kim, Byung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.335-335
    • /
    • 2022
  • 남한상세 기후변화 전망보고서(2021)는 2100년대 강원도 강수량이 현재보다 19% 증가하고, 평균기온이 현재보다 6.5℃ 상승할 것으로 공표했다. 강원도는 영동지역과 영서지역으로 분리돼 기후 차이가 분명하다. 기상청 ASOS 데이터(1986~2020)를 이용해 기후 특성을 확인한 결과 영동지역 강수량은 1,463mm, 평균기온은 10.5℃, 상대습도는 66%로 분석됐고, 영서지역 강수량은 1,307mm, 평균기온은 11℃, 상대습도는 68%로 분석됐다. 영동지역 강수량이 영서지역 강수량보다 약 156mm 더 많으며, 이는 영동지역에서 큰 규모의 우심 피해가 발생할 가능성이 존재함을 의미한다. 강원도 평년 우심 피해 현황을 살펴본 결과 영동지역은 5회(피해액: 62억 원), 영서지역은 24회(피해액: 62억원)가 발생했다. 이는 미래로 갈수록 더 심해질 것으로 판단되며, 이런 기상 재난을 객관적으로 판단할 수 있는 기준이 필요하다. 이에 본 연구에서는 기후변화에 따른 강원도 기후 재난취약성을 평가했다. 이를 위해 기후변화 위험성, 기후변화 민감도, 기후변화 적응능력 지표를 활용해 기후변화 취약성 지표를 선정했다. 기후변화 위험성 지표는 홍수(CWD, Rx5day, R30mm), 가뭄(CDD, SU, TX90p), 폭염(SU, TR, TN90p), 한파(ID, TX10p, FD)로 RCP 8.5 기후변화시나리오를 ETCCDI 지수에 적용했다. 기후변화 민감도와 기후변화 적응능력 지표는 국가통계포털, 강원통계정보, WAMIS에서 자료를 수집해 선정했다. 또한 재난취약성 지표를 4단계(Very Low, Low, High, Very High)로 구분했다. 홍수 취약성 평가 결과 2090년대 원주시, 춘천시, 횡성군이 Low에서 Very High로 단계가 격상됐다. 가뭄 취약성 평가 결과 2090년대 양양군, 영월군, 정선군이 Very Low에서 Very High로 단계가 격상됐다. 폭염 취약성 평가 결과 2090년대 삼척시, 태백시, 영월군이 Very Low에서 Very High로 단계가 격상됐다. 한파 취약성 평가 결과 삼척시, 태백시, 영월군이 High에서 Very Low로 단계가 격하됐다. 고로 강원도는 기후 재난취약성 평가 결과에 따른 미래 기후변화를 대비하고, 각 지역 특성에 맞는 복원력 관점 기후 재난 관리가 필요하다고 사료된다.

  • PDF

Effects of Atmospheric factors on Local Adaption Rearing Test Results of Superior Breeding Combination of Silkworms (기상요소가 누에 우량교배조 지역적응시험의 작황에 미치는 영향)

  • Sohn, Bong-Hee;Kang, Pil-Don;Ryu, Kang-Sun;Jung, I-Yeon;Kim, Yong-Soon;Kim, Kee-Young;Kim, Mi-Ja
    • Journal of Sericultural and Entomological Science
    • /
    • v.49 no.2
    • /
    • pp.51-55
    • /
    • 2007
  • Investigation of atmospheric data and rearing results was conducted to analyze the effects of atmospheric factors such as temperature and precipitation on silkworm in 8 rearing places in which local adaptation test was being conducted with different mulberry growth condition, soil and atmosphere during spring and autumn rearing season of 2006. The atmospheric characteristics of spring rearing time are as follows. The average temperatures of young silkworm, old silkworm, mounting were $17.7^{\circ}C$, $19.8^{\circ}C$, $21.5^{\circ}C$ respectively, and $1^{\circ}C$ higher than normal year. The precipitation of young silkworm, old silkworm, mounting were 15.1 mm, 6.9 mm, 7.0 mm, respectively, and 22.9 mm lower than normal year in old silkworm and mounting. The daylight hours in larval stage was 1.7 hour shorter than normal year, but no difference in mounting. Thus precipitation was lower and temperature was higher than normal year in 2006. The rearing results of 2006 were 1 kg lower than normal year in cocoon yields per 10,000 3 rd molted larvae, single cocoon weight and cocoon shell percentage were a little higher. The atmospheric characteristics of spring rearing season are as follows. The average temperatures of young silkworm, old silkworm, mounting were $25.1^{\circ}C$, $20.5^{\circ}C$ and $19.9^{\circ}C$ respectively, temperature in young silkworm was $1^{\circ}C$ higher than normal year, and temperature in old silkworm was $1.3^{\circ}C$ lower than normal year. The precipitation of young silkworm, old silkworm, mounting were 110.2 mm, 4.6 mm, 3.7 mm, respectively and there were little differences compared to normal year. The atmospheric condition of 2006 which was similar to normal year did not affect the autumn rearing results of 2006. Namely, the single cocoon weight and cocoon shell weight were not different from normal year, and the same was cocoon shell percentage.

Improvement and Evaluation of Multi-purpose Dam Operation Rule Considering Climate Change (기후변화를 고려한 다목적댐 운영기준 개선 및 평가)

  • Kim, Hyung-San;Park, Jin-Hyeog;Kang, Shin-Uk;Jang, Su-Hyung
    • Journal of Wetlands Research
    • /
    • v.21 no.spc
    • /
    • pp.9-15
    • /
    • 2019
  • Rainfall patterns are changing due to climate change, the frequency of drought occurrence is shortening, and the operation of the multi-purpose dams is also changing. The importance of preventing water shortage of multi-purpose dams in advance and operation for stable water supply is increasing. In this study, we developed and evaluated the operational criteria reflecting climate change scenarios based on the operational criteria currently applied to multi-purpose dams. Standard water volume lines reflecting climate change were found to increase 34% on average, as a result of evaluation with the existing standard, it was analyzed that water supply would not be difficult if the multi-purpose dam operation standard reflecting climate change was applied. The results of this study are expected to be helpful for the establishment of multi-purpose dams reflecting climate change.

Analysis of Optimal Evacuation Route for Flood Disaster (홍수재난에 대한 최적 대피경로 분석)

  • Kim, Kyong-Hoon;Park, Jae-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.2
    • /
    • pp.169-177
    • /
    • 2018
  • There is a lot of loss of life due to natural disasters. In particular, flood damage caused by heavy rainfall in urban areas causes serious damage. Therefore, in this study, we conducted a study on the optimal evacuation route for safe evacuation of urban areas. We set up a methodology by reviewing Flo-2D model and A* algorithm. A Flo-2D model was used to derive the hazardous area, and we selected the starting points with many people and suggested ways to select safe evacuation sites. And the route was derived from the starting point to the safe evacuation point by using the A * algorithm. This study could be used not only for evacuation route but also for road maintenance and evacuation facilities.

Evaluation of Stored Rainwater Quality and Economic Efficiency at Yangdo Elementary Rainwater Harvesting System (양도 초등학교 빗물이용시설의 수질 및 경제성 평가)

  • Kim, Kiyoung;Park, Hyunju;Kim, Tschungil;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.333-341
    • /
    • 2014
  • To supply substitution water, $2m^3$ of capacity of rainwater harvesting system is designed calculating rainfall, catchment area and LPCD and has a effects to 34.4% of substitution water supply and 237 days of service day. Rainwater of drinking water quality was judged to be suitable except for bacteria problem, however, groundwater is exceeded in nitrate nitrogen, the evaporation residue and also bacteria, which means that the rainwater is suitable for use as water supply. In addition, to consider cost-benefit ratio, economic analysis conducted. The result is that B/C ratio of RWHS (10 years) is 1.70. It means total benefit is bigger than cost. Except to social factor in this study, there are a variety of benefit such as flood or drought prevention, educational effects inspiring water conservation awareness.