• Title/Summary/Keyword: * $_f$-Max(D)

Search Result 163, Processing Time 0.024 seconds

Design of a GaN HEMT 4 W Miniaturized Power Amplifier Module for WiMAX Band (WiMAX 대역 GaN HEMT 4 W 소형 전력증폭기 모듈 설계)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Heo, Yun-Seong;Yeom, Kyung-Whan;Kim, Kyoung-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.162-172
    • /
    • 2011
  • In this paper, a design and fabrication of 4 W power amplifier for the WiMAX frequency band(2.3~2.7 GHz) are presented. The adopted active device is a commercially available GaN HEMT chip of Triquint Company, which is recently released. The optimum input and output impedances are extracted for power amplifier design using a specially self-designed tuning jig. Using the adopted impedances value, class-F power amplifier was designed based on EM simulation. For integration and matching in the small package module, spiral inductors and interdigital capacitors are used. The fabricated power amplifier with $4.4{\times}4.4\;mm^2$ shows the efficiency above 50 % and harmonic suppression above 40 dBc for second(2nd) and third(3rd) harmonic at the output power of 36 dBm.

Analysis and Optimization of the CMOS Transistors for RF Applications with Various Channel Width and Length (CMOS 트랜지스터의 채널 폭 및 길이 변화에 따른 RF 특성분석 및 최적화)

  • Choi, Jeong-Ki;Lee, Sang-Gug;Song, Won-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.9-16
    • /
    • 2000
  • MOS transistors are fabricated and evaluated for RF IC applications such as mobile communication systems using 0.35m CMOS process. Characteristics of MOSFETs are analyzed at various channel length, width and bias conditions. From the analysis, cut-off frequency ($f_T$) is independent on channel width but maximum oscillation frequency ($f_{max}$) tends to derease as the channel width increases. As channel length increases, $f_T$ and fmax decrease. $f_T$ is 22GHz and fmax is 28GHz at its maximum value. High frequency noise performance is improved with larger channel width and smaller channel length at same bias conditions. NFmin at 2GHz is 0.45dB as a minimum value. From the evaluation, MOSFETs designed using 0.35m CMOS process demonstrated a full potential for the commercial RF ICs for mobile communication systems near 2GHz. And optimization methods of the CMOS transistors for RF applications are presented in this paper.

  • PDF

HEIGHT BOUND AND PREPERIODIC POINTS FOR JOINTLY REGULAR FAMILIES OF RATIONAL MAPS

  • Lee, Chong-Gyu
    • Journal of the Korean Mathematical Society
    • /
    • v.48 no.6
    • /
    • pp.1171-1187
    • /
    • 2011
  • Silverman [14] proved a height inequality for a jointly regular family of rational maps and the author [10] improved it for a jointly regular pair. In this paper, we provide the same improvement for a jointly regular family: let h : ${\mathbb{P}}_{\mathbb{Q}}^n{\rightarrow}{{\mathbb{R}}$ be the logarithmic absolute height on the projective space, let r(f) be the D-ratio of a rational map f which is de ned in [10] and let {$f_1,{\ldots},f_k|f_l:\mathbb{A}^n{\rightarrow}\mathbb{A}^n$} bbe finite set of polynomial maps which is defined over a number field K. If the intersection of the indeterminacy loci of $f_1,{\ldots},f_k$ is empty, then there is a constant C such that $ \sum\limits_{l=1}^k\frac{1}{def\;f_\iota}h(f_\iota(P))>(1+\frac{1}{r})f(P)-C$ for all $P{\in}\mathbb{A}^n$ where r= $max_{\iota=1},{\ldots},k(r(f_l))$.

Effect of additives and filling methods on whole plant corn silage quality, fermentation characteristics and in situ digestibility

  • Jiao, Ting;Lei, Zhaomin;Wu, Jianping;Li, Fei;Casper, David P.;Wang, Jianfu;Jiao, Jianxin
    • Animal Bioscience
    • /
    • v.34 no.11
    • /
    • pp.1776-1783
    • /
    • 2021
  • Objective: This project aimed to evaluate the effects of both different additives and filling methods on nutritive quality, fermentation profile, and in situ digestibility of whole plant corn silage. Methods: Whole plant corn forage harvested at 26.72% dry matter (DM) was chopped and treated with two filling methods, i) fill silos at one time (F1), ii) fill silos at three times (F3), packing samples into one/three silo capacity at the first day, another one/three capacity at the second day, then one/three at the third day, three replicates. For each replicate, samples were treated with three additives, i) control (CTRL, no additive), ii) Sila-Max (MAX, Ralco Nutrition Inc., Marshall, MN, USA), and iii) Sila-Mix (MIX, Ralco Nutrition Inc., USA). With three replicates of each secondary treatment, there were nine silos, 54 silos in total. Each silo had a packing density of 137.61 kg of DM/m3. All silos were weighed and stored in lab at ambient temperature. Results: After 60 d of ensiling, all items showed good silage fermentation under MAX filled one time or three times (p<0.01). Higher silage quality for all additives was obtained at filling one time than that filled three times (p<0.01). The highest DM and lowest DM loss rate (DMLR) occurred to MAX treatment at two filling methods (p<0.01); Digestibility of acid detergent fiber, neutral detergent fiber (NDF), and curde protein had the same results as silage quality (p<0.01). Yield of digestible DM and digestible NDF also showed higher value under MAX especially for filling one time (p<0.05). Conclusion: All corn silages showed good fermentation attributes (pH<4.0). The forage filled one time had higher silage quality than that filled three times (p<0.01). MAX with homofermentative lactic acid bacteria enhanced the lactic acid fermentation, silage quality and nutrient digestibility, and so improved the digestible nutrient yield.

Prognostic value of nodal SUVmax of 18F-FDG PET/CT in nasopharyngeal carcinoma treated with intensity-modulated radiotherapy

  • Lee, So Jung;Kay, Chul-Seoung;Kim, Yeon-Sil;Son, Seok Hyun;Kim, Myungsoo;Lee, Sea-Won;Kang, Hye Jin
    • Radiation Oncology Journal
    • /
    • v.35 no.4
    • /
    • pp.306-316
    • /
    • 2017
  • Purpose: To investigate the predictive role of maximum standardized uptake value ($SUV_{max}$) of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) in nasopharyngeal cancer patients treated with intensity-modulated radiotherapy (IMRT). Materials and Methods: Between October 2006 and April 2016, 53 patients were treated with IMRT in two institutions and their PET/CT at the time of diagnosis was reviewed. The $SUV_{max}$ of their nasopharyngeal lesions and metastatic lymph nodes (LN) was recorded. IMRT was delivered using helical tomotherapy. All patients except for one were treated with concurrent chemoradiation therapy (CCRT). Correlations between $SUV_{max}$ and patients' survival and recurrence were analyzed. Results: At a median follow-up time of 31.5 months (range, 3.4 to 98.7 months), the 3-year overall survival (OS) and disease-free survival (DFS) rates were 83.2% and 77.5%, respectively. In univariate analysis, patients with a higher nodal pre-treatment $SUV_{max}$ (${\geq}13.4$) demonstrated significantly lower 3-year OS (93.1% vs. 55.5%; p = 0.003), DFS (92.7% vs. 38.5%; p < 0.001), locoregional recurrence-free survival (100% vs. 50.5%; p < 0.001), and distant metastasis-free survival (100% vs. 69.2%; p = 0.004), respectively. In multivariate analysis, high pre-treatment nodal $SUV_{max}$ (${\geq}13.4$) was a negative prognostic factor for OS (hazard ratio [HR], 7.799; 95% confidence interval [CI], 1.506-40.397; p = 0.014) and DFS (HR, 9.392; 95% CI, 1.989-44.339; p = 0.005). Conclusions: High pre-treatment nodal $SUV_{max}$ was an independent prognosticator of survival and disease progression in nasopharyngeal carcinoma patients treated with IMRT in our cohort. Therefore, nodal $SUV_{max}$ may provide important information for identifying patients who require more aggressive treatment.

금속쐐기와 가상쐐기의 출력비교

  • 강위생
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.42-42
    • /
    • 2003
  • 목적 : 조사면 크기에 따른 금속쐐기와 가상쐐기에 의한 6 MV 와 15 MV 엑스선의 출력 및 상부와 하부 에 설치하는 금속쐐기의 출력을 비교하고자 한다. 대상 및 방법 : Varian Clinac21EX(미국)는 두부의 상부와 하부에 설치하는 각각의 금속쐐기와 제한기에 의한 가상쐐기 기능을 가지고 있다. 금속쐐기의 쐐기각은 네 가지 (15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$)이며 투과력에 무관하게 한 쐐기각에 대한 쐐기는 사하부는 각 1 개이고, 가상쐐기는 일곱 가지 ($10^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, 25$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$) 이다. 각 쐐기에 대하여 3$\times$3~20$\times$20 $\textrm{cm}^2$ 의 조사면 크기에서 6 및 15 MV 엑스선의 쐐기출력인수 (wedge field output factor)를 $d_{max}$와 10 $\textrm{cm}^2$ 깊이에서 측정하였다. 조사면크기와 측정깊이에 따른 쐐기출력인수의 변화추이를 관찰하였다. 쐐기출력인수 O $F_{Wdg}$는 다음과 같다. O $F_{Wdg}$(r)= $D_{Wdg}$(r)/ $D_{op}$ ( $r_{0}$) 여기서 $r_{0}$와 r은 각각 민조사면의 기준조사면크기, 쐐기조사면크기이다. 하부쐐기에 대한 상부쐐기의 출력인수의 상대적인 백분율 차이, %ROD=l00$\times$(O $F_{upWdg}$/O $F_{lowWdg}$ lowWdg/ - 1)를 구하였다. 조사면크기와 깊이에 따른 %ROD의 변화추이를 평가하였으며 쐐기 각각에 대하여 출력인수를 측정해야하는지 평가하였다. 결과 : 금속쐐기에 대한 쐐기출력인수는 방사선의 투과력과 깊이에 관계없이 조사면 크기가 커짐에 따라 증가하였으나 가상쐐기의 쐐기출력인수는 쐐기각이 작은 경우에는 조사면크기가 커짐에 따라 증가하다가 감소하였으며 최대값을 보이는 조사면크기는 쐐기각이 커짐에 반하여 감소하였으며 투과력에 관계없이 60。 쐐기에 대해서는 조사면 크기가 4 cm(A/P=1) 이상에서 조사면크기가 커짐에 따라 감소하였다. 6 MV 엑스선 에 대한 10 cm 깊이에서 15。 쐐기와 15 MV 엑스선에 대한 10 cm 깊이에서 45。 쐐기의 A/P 가 1.5보다 작은 조사면을 제외하고는 조사면의 크기가 커짐에 따라 %ROD는 감소하였다. $d_{max}$에서는 15。 쐐기와 30。 쐐기에 대해서는 %ROD가 음수였으며 절대값이 증가하였다. 이는 곧 조사면의 크기가 커짐에 따라 상부쐐기의 쐐기출력계수가 하부쐐기와 접근하고 드디어는 상부쐐기의 출력인수가 하부쐐기의 출력인수보다 작아질 수도 있다는 것을 의미하고 있다. 또한 %ROD 는 쐐기각이 클수록 변화가 컸으며, 조사면 크기가 커짐에 따라 10 cm 깊이에서보다 $d_{max}$에서 더 급하게 감소하였다. %ROD 는 6 MV 엑스선에 대해서는 -0.52~4.18 % 였고, 15 MV 엑스선에 대해서는 -0.44-4.18 % 였다. 결론 : 두 가지 투과력의 엑스선이 방출되는 선형가속기의 상하부 쐐기와 가상쐐기의 출력인수를 측정하여 비교하였다. 결과에서 얻어진 결론은 아래와 같다. 1. 조사면의 크기가 커짐에 따라 금속쐐기의 출력계수 는 증가하였으나 가상쐐기의 경우는 증가하다가 감소하거나 큰 쐐기각에 대해서는 감소만 하였다. 2. 상부쐐 기와 하부쐐기는 쐐기출력인수가 4% 이상 차이가 날 수 있으므로 독립적으로 측정하여 이용하여야 할 것이다.것이다.다.

  • PDF

RADIO AND RADIO ANTIPODAL LABELINGS FOR CIRCULANT GRAPHS G(4k + 2; {1, 2})

  • Nazeer, Saima;Kousar, Imrana;Nazeer, Waqas
    • Journal of applied mathematics & informatics
    • /
    • v.33 no.1_2
    • /
    • pp.173-183
    • /
    • 2015
  • A radio k-labeling f of a graph G is a function f from V (G) to $Z^+{\cup}\{0\}$ such that $d(x,y)+{\mid}f(x)-f(y){\mid}{\geq}k+1$ for every two distinct vertices x and y of G, where d(x, y) is the distance between any two vertices $x,y{\in}G$. The span of a radio k-labeling f is denoted by sp(f) and defined as max$\{{\mid}f(x)-f(y){\mid}:x,y{\in}V(G)\}$. The radio k-labeling is a radio labeling when k = diam(G). In other words, a radio labeling is an injective function $f:V(G){\rightarrow}Z^+{\cup}\{0\}$ such that $${\mid}f(x)=f(y){\mid}{\geq}diam(G)+1-d(x,y)$$ for any pair of vertices $x,y{\in}G$. The radio number of G denoted by rn(G), is the lowest span taken over all radio labelings of the graph. When k = diam(G) - 1, a radio k-labeling is called a radio antipodal labeling. An antipodal labeling for a graph G is a function $f:V(G){\rightarrow}\{0,1,2,{\ldots}\}$ such that $d(x,y)+{\mid}f(x)-f(y){\mid}{\geq}diam(G)$ holds for all $x,y{\in}G$. The radio antipodal number for G denoted by an(G), is the minimum span of an antipodal labeling admitted by G. In this paper, we investigate the exact value of the radio number and radio antipodal number for the circulant graphs G(4k + 2; {1, 2}).

뫼스바우어 분광학과 $\delta$ M plot을 사용한 Nanocomposite magnet의 자기특성 규명 연구

  • 한종수;김응찬;양충진;박언병
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.204-205
    • /
    • 2003
  • Nano 결정립 N $d_2$F $e_{l4}$B+F $e_3$B 복합상 자성 리본은 Extractive melt spinner의 wheel speed를 달리하여 제조하였다. 초기 조성은 N $d_4$F $e_{77.5}$ $B_{18.5}$이고, 이후 제조한 자성 리본의 자기특성은 VSM 및 AGM(Alternating gradient magnetometer)으로 측정하였다. wheel speed 1500rpm, $650^{\circ}C$에서 10분간 열처리한 자성 리본에서 $B_{r}$ = 11.73 kG, $_{i}$ $H_{c}$ = 3.082 kOe, (BH)$_{max}$ = 12.28 MGOe의 자기특성이 나타났다. 이러한 자기특성 원인 규명을 위해 $\delta$M plot과 뫼스바우어 분광학을 사용하였다. $\delta$M plot을 통해 exchange coupling은 초미세립 복합상의 잔류자속밀도에 큰 영향을 미치는 것으로 판단된다. 또한, 뫼스바우어 분광학을 통해 경자성상(N $d_2$F $e_{l4}$B)과 연자성상 F $e_3$B의 부피분율비가 7:3 정도일 때 가장 최적의 자기특성을 발현하였다. 이 경우에 초미세립 복합상의 상호작용력이 가장 크게 발현하는 것으로 판단된다.단된다..된다..된다..

  • PDF

Design of 24GHz Low Noise Amplifier for Automotive Collision Avoidance Radar (차량 충돌 예방 레이더 시스템-온-칩용 77GHz 고주파 전단부 설계)

  • Kim, Shin-Gon;Lee, Jung-Hoon;Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.815-817
    • /
    • 2012
  • 본 논문에서는 차량 충돌 예방 레이더 시스템-온-칩용 77GHz 고주파 전단부(RF front-end)를 제안한다. 이러한 고주파 전단부는 77GHz의 동작주파수를 가진 저 잡음 증폭기와 고주파 전력 증폭기로 구성된다. 이러한 회로는 TSMC $0.13{\mu}m$ 혼성신호/고주파 CMOS 공정 ($f_T/f_{MAX}=120/140GHz$)으로 설계되어 있다. 저잡음 증폭기의 경우 전압이득이 36dB로 최근 발표된 연구결과 중 가장 우수한 수치를 보였다. 전력 증폭기는 포화전력과 출력 $P_{1dB}$이 18dBm과 15dBm으로 기존 연구결과 중 가장 우수한 결과를 각각 보였다.

  • PDF

Design of 24GHz Mixer for Automotive Collision Avoidance Radar (차량 충돌 예방 레이더 시스템-온-칩용 24GHz 믹서 설계)

  • Kim, Cheol-Hwan;Kim, Shin-Gon;Lee, Jae-Hwan;Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.766-767
    • /
    • 2013
  • 본 논문에서는 차량 충돌 예방 레이더 시스템-온-칩용 24GHz 믹서(Mixer)를 제안한다. 이러한 회로는 24GHz의 동작주파수를 가지며, Gilbert 셀 구조로 구성된다. 이러한 회로는 TSMC $0.13{\mu}m$ 혼성신호/고주파 CMOS 공정 ($f_T/f_{MAX}=120/140GHz$)으로 설계되어 있다. 제안한 회로는 10.96dB의 변환이득으로 최근 발표된 연구결과 중 가장 우수한 수치를 보였다. 또한 7.62dBm의 우수한 IIP3의 특성과 -43.64dB의 입력/출력 반사손실 (S11/S22) 및 -49.3dB의 LO-RF간 격리 특성 (S12)으로 기존 연구결과 중 가장 우수한 결과를 각각 보였다.

  • PDF