• Title/Summary/Keyword: (C,1) mean

Search Result 4,885, Processing Time 0.033 seconds

Air Temperature Modification of an Urban Neighborhood Park in Summer - Hyowon Park, Suwon-si, Gyeonggi-do- (여름철 도시근린공원의 기온저감 효과 - 경기도 수원시 효원공원 -)

  • Park, Sookuk;Jo, Sangman;Hyun, Cheolji;Kong, Hak-Yang;Kim, Seunghyun;Shin, Youngkyu
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1057-1072
    • /
    • 2017
  • In order to investigate the effect of air temperature reduction on an urban neighborhood park, air temperature data from five inside locations (forest, pine tree, lawn, brick and pergola) depending on surface types and three outside locations (Suwon, Maetan and Kwonsun) depending on urban forms were collected during the summer 2016 and compared. The forest location had the lowest mean air temperature amongst all locations sampled, though the mean difference between this and the other four locations in the park was relatively small ($0.2-0.5^{\circ}C$). In the daytime, the greatest mean difference between the forest location and the two locations exposed to direct beam solar radiation (brick and lawn) was $0.5-0.8^{\circ}C$ (Max. $1.6-2.1^{\circ}C$). In the nighttime, the mean difference between the forest location and the other four locations in the park was small, though differences between the forest location and locations with grass cover (pine tree and lawn) reached a maximum of $0.9-1.7^{\circ}C$. Comparing air temperature between sunny and shaded locations, the shaded locations showed a maximum of $1.5^{\circ}C$ lower temperature in the daytime and $0.7^{\circ}C$ higher in the nighttime. Comparing the air temperature of the forest location with those of the residential (Kwonsun) and apartment (Maetan) locations, the mean air temperature difference was $0.8-1.0^{\circ}C$, higher than those measured between the forest location and the other park locations. The temperatures measured in the forest location were mean $0.9-1.3^{\circ}C$ (Max. $2.0-3.9^{\circ}C$) lower in the daytime than for the residential and apartment locations and mean $0.4-1.0^{\circ}C$ (Max. $1.3-3.1^{\circ}C$) lower in the nighttime. During the hottest period of each month, the difference was greater than the mean monthly differences, with temperatures in the residential and apartment locations mean $1.0-1.6^{\circ}C$ higher than those measured in the forest location. The effect of air temperature reduction on sampling locations within the park and a relatively high thermal environment on the urban sampling locations was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with a high sky view factor and surface types with high evapotranspiration potential (e.g. grass) showed the maximum air temperature reduction. In the urban areas outside the park, the low-rise building area, with a high sky view factor, showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, while in the nighttime the area with high-rise buildings, and hence a low sky view factor, showed high air temperature due to the effect of terrestrial (longwave) radiation emitted by surrounding high-rise building surfaces. The effect of air temperature reduction on the park with a high thermal environment in the city was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with high sky view factor and surface types (e.g., grass) with evapotranspiration effect showed maximum air temperature reduction. In the urban areas outside the park, the high sky view factor area (low-rise building area) showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, but in the nighttime the low sky view factor area (high-rise building area) showed high air temperature due to the effect of terrestrial (longwave) radiation emitted surrounding high-rise building surfaces.

Lead (Pb) Concentrations in Soil, Air and Fruits of Sweet Orange (Citrus sinensis L. Osbeck) in Selected Landuse in Port Harcourt Metropolis, Rivers State, Nigeria

  • Eludoyin, Olatunde Sunday;Odimegwu, Vitus Chinonso
    • Journal of Forest and Environmental Science
    • /
    • v.34 no.4
    • /
    • pp.284-292
    • /
    • 2018
  • The study investigated the concentrations of Pb in soil, air and fruit of C. sinensis in selected landuse types in Port Harcourt Metropolis, Rivers State, Nigeria. Five fruits of C. sinensis were collected randomly in residential, commercial, industrial and natural forest (control). The weight, length and width of the C. sinensis fruits were measured. A total of three soil samples were collected around the C. sinensis trees where the fruits were collected into well labeled polythene bags and thereafter taken to laboratory for analysis. Pb concentrations in C. sinensis and soil samples were analysed using atomic absorption spectrophotometer (AAS). The concentration of Pb in the air was measured for 14 days using Aeroquel 500. The significant relationship between Pb concentration in the C. sinensis fruits, soil and air was determined using Spearman's rank correlation. Findings showed that the mean weight and width of C. sinensis fruits were highest in the residential landuse while the mean length of C. sinensis fruits was highest in the industrial landuse. However, the mean Pb concentration in the C. sinensis fruit was highest in the industrial landuse ($0.46{\pm}0.15mg\;kg^{-1}$), commercial landuse ($0.33{\pm}0.09mg\;kg^{-1}$) and the least was found in the natural forest ($0.25{\pm}0.06mg\;kg^{-1}$). The mean Pb concentration in the soil was highest in the industrial landuse ($0.177{\pm}0.16mg\;kg^{-1}$) and commercial landuse ($0.121{\pm}0.10mg\;kg^{-1}$). However, the mean Pb concentration in the air was highest in the industrial landuse ($0.85{\pm}0.09mg\;kg^{-1}$) and followed by commercial landuse ($0.30{\pm}0.17mg\;kg^{-1}$). The correlations between the Pb concentration in the C. sinensis fruit and soil (r=0.768, p<0.05) and air (r=0.642, p<0.05) were significant. The study concluded that the Pb concentration in the C. sinensis fruits was higher than the WHO standard; hence people should be discouraged to consume them, especially those from the industrial and commercial areas.

A follow-up study of electrocardiographic changes following the corrective surgery for atrial septal defect in adult (성인에 있어서 심방중격결손증 교정수술후 심전도의 경시적 변화에 관한 연구)

  • Lee, Young-Thak;Chae, Hurn;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.241-250
    • /
    • 1987
  • We scrutinized the preoperative electrocardiographic and hemodynamic findings in adult atrial septal defects older than 15 years, and then followed up the postoperative electrocardiographic changes sequentially. In preoperative electrocardiographs, the mean PR interval [0.17 sec] was prolonged than normal adults [M;0.13,F;0.15], and the mean QRS axis [93.1*] was deviated to rightward than normal [M;63.7*,F;64.4*], and 122 cases of all 159 patients [77.8%] were in RAD quadrant. The QRS morphology was classified into three groups; a] crista supraventricularis hypertrophy, 25 cases, b] right ventricular outflow tract hypertrophy, 89 cases, c] right ventricular hypertrophy, 44 cases, and normal rs pattern, 1 case. Comparing the QP/QS, Pp/Ps, Rp/Rs in these three groups, Qp/Qs increased a] 2.65 to b] 2.97 and decreased b] 2.97 to c] 2.55, Pp/Ps increased a] 0.27 to b] 0.35 to c] 0.44, and Rp/Rs increased a] 0.1 to b] 0.14 to c] 0.2. In comparing the atrial fibrillation with sinus rhythm, the patient`s mean age was increased [26.4 to 45.7], the mean Qp/Qs was decreased [2.97 to 2.7], the mean Pp/Ps was increased [0.35 to 0.46], the mean Rp/Rs increased [0.14 to 0.2], and the QRS morphology was RVOT hypertrophy;7 cases, RVH;2 cases in all 11 cases. Therefore, the atrial fibrillation was appeared in progressed status. Increasing the mean pulmonary arterial pressure, size of the R` wave in Vl lead increased, and the QRS morphology tended to become severe patterns. Postoperatively, the PR interval shortened and QRS axis tended to normal axis quadrant, and size of R` wave decreased sequentially, atrial fibrillation disappeared in 4 cases. Conclusively, by use of the conventional surface electrocardiography, we could anticipate the hemodynamic changes and the prognosis at outpatient department.

  • PDF

Accuracy, Precision, and Validity of Fever Detection using Non-invasive Temperature Measurement in Adult Coronary Care Unit Patients with Pulmonary Catheters (폐동맥관을 부착하고 있는 심장수술 환자에 대한 비침습적 체온측정 방법의 정확도, 정밀도 및 발열감별 타당도)

  • Joo, Ga-Eul;Sohng, Kyeong-Yae
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.3
    • /
    • pp.424-433
    • /
    • 2012
  • Purpose: To investigate the accuracy, precision and validity of fever detection of tympanic membrane (TM), temporal artery (TA) and axillary temperature (AT) compared with pulmonary artery temperature (PA). Methods: Repeated-measures design was conducted for one year on 83 adult cardiac care unit patients with pulmonary artery catheters after open heart surgery. Sequential temperature measurements were taken three times at 20-minute intervals. Accuracy, precision, repeatability, and validity of fever detection were analyzed. Results: Mean pulmonary artery temperature was $37.04^{\circ}C$ (SD $0.70^{\circ}C$). The mean (SD) offsets from PA, with the mean reflecting accuracy and SD reflecting precision, were $-1.31^{\circ}C$ ($0.75^{\circ}C$) for TA, $-0.20^{\circ}C$ ($0.24^{\circ}C$) for TM, and $-0.97^{\circ}C$ ($0.64^{\circ}C$) for AT. Percentage of pairs with differences within ${\pm}0.5^{\circ}C$ was 9.6% for TA, 19.7% for AT, and 91.6% for TM. Repeated measurements with all three methods had mean SD values within $0.04^{\circ}C$. Sensitivity, specificity, and positive and negative predictive values of tympanic measurements were 0.76, 1.0, and 1.0, and 0.90, respectively. Conclusion: Results show that TM best reflects PA, and is most consistent, accurate, and precise. AT tends to underestimate PA, and TA is least accurate and precise. Therefore tympanic membrane measurement is a reliable alternative to other non-invasive methods of measuring temperatures.

Morphometric Study of the Nerve Roots Around the Lateral Mass for Posterior Foraminotomy

  • Hwang, Jae-Chan;Bae, Hak-Geun;Cho, Sung-Won;Cho, Sung-Jin;Park, Hyung-Ki;Chang, Jae-Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.358-364
    • /
    • 2010
  • Objective : Morphometric data on dorsal cervical anatomy were examined in an effort to protect the nerve root near the lateral mass during posterior foraminotomy. Methods : Using 25 adult formalin-fixed cadaveric cervical spines, measurements were taken at the lateral mass from C3 to C7 via a total laminectomy and a medial one-half facetectomy. The morphometric relationship between the nerve roots and structures of the lateral mass was investigated. Results from both genders were compared. Results : Following the total laminectomy, from C3 to C7, the mean of the vertical distance from the medial point of the facet (MPF) of the lateral mass to the axilla of the root origin was 3.2-4.7 mm. The whole length of the exposed root had a mean of 4.2-5.8 mm. Following a medial onehalf facetectomy, from C3 to C7, the mean of the vertical distance to the axilla of the root origin was 2.1-3.4 mm, based on the MPF. Mean vertical distances from the MPF to the medial point of the root that crossed the inferior margin of the intervertebral disc were 1.2-2.7 mm. The mean distance of the exposed root was 8.2-9.0 mm, and the mean angle between the dura and the nerve root was significantly different between males and females, at $53.4-68.4^{\circ}$. Conclusion : These data will aid in reducing root injuries during posterior cervical foraminotomy.

PAIR MEAN CORDIAL LABELING OF GRAPHS OBTAINED FROM PATH AND CYCLE

  • PONRAJ, R.;PRABHU, S.
    • Journal of Applied and Pure Mathematics
    • /
    • v.4 no.3_4
    • /
    • pp.85-97
    • /
    • 2022
  • Let a graph G = (V, E) be a (p, q) graph. Define $${\rho}\;=\;\{\array{{\frac{p}{2}}&p\text{ is even}\\{\frac{p-1}{2}}\;&p\text{ is odd,}}$$ and M = {±1, ±2, ⋯ ± 𝜌} called the set of labels. Consider a mapping λ : V → M by assigning different labels in M to the different elements of V when p is even and different labels in M to p - 1 elements of V and repeating a label for the remaining one vertex when p is odd. The labeling as defined above is said to be a pair mean cordial labeling if for each edge uv of G, there exists a labeling $\frac{{\lambda}(u)+{\lambda}(v)}{2}$ if λ(u) + λ(v) is even and $\frac{{\lambda}(u)+{\lambda}(v)+1}{2}$ if λ(u) + λ(v) is odd such that ${\mid}\bar{\mathbb{S}}_{{\lambda}_1}-\bar{\mathbb{S}}_{{\lambda}^c_1}{\mid}{\leq}1$ where $\bar{\mathbb{S}}_{{\lambda}_1}$ and $\bar{\mathbb{S}}_{{\lambda}^c_1}$ respectively denote the number of edges labeled with 1 and the number of edges not labeled with 1. A graph G for which there exists a pair mean cordial labeling is called a pair mean cordial graph. In this paper, we investigate the pair mean cordial labeling of graphs which are obtained from path and cycle.

ON PAIR MEAN CORDIAL GRAPHS

  • R. PONRAJ;S. PRABHU
    • Journal of Applied and Pure Mathematics
    • /
    • v.5 no.3_4
    • /
    • pp.237-253
    • /
    • 2023
  • Let a graph G = (V, E) be a (p, q) graph. Define $${\rho}=\{\array{{\frac{p}{2}} & \;\;p\text{ is even} \\ {\frac{p-1}{2}} & \;\;p\text{ is odd,}$$ and M = {±1, ±2, … ± ρ} called the set of labels. Consider a mapping λ : V → M by assigning different labels in M to the different elements of V when p is even and different labels in M to p - 1 elements of V and repeating a label for the remaining one vertex when p is odd. The labeling as defined above is said to be a pair mean cordial labeling if for each edge uv of G, there exists a labeling ${\frac{{\lambda}(u)+{\lambda}(v)}{2}}$ if λ(u) + λ(v) is even and ${\frac{{\lambda}(u)+{\lambda}(v)+1}{2}}$ if λ(u) + λ(v) is odd such that ${\mid}{\bar{{\mathbb{S}}}}_{\lambda}{_1}-{\bar{{\mathbb{S}}}}_{{\lambda}^c_1}{\mid}{\leq}1$ where ${\bar{{\mathbb{S}}}}_{\lambda}{_1}$ and ${\bar{{\mathbb{S}}}}_{{\lambda}^c_1}$ respectively denote the number of edges labeled with 1 and the number of edges not labeled with 1. A graph G for which there exists a pair mean cordial labeling is called a pair mean cordial graph. In this paper, we investigate the pair mean cordial labeling behavior of few graphs including the closed helm graph, web graph, jewel graph, sunflower graph, flower graph, tadpole graph, dumbbell graph, umbrella graph, butterfly graph, jelly fish, triangular book graph, quadrilateral book graph.

A study on the Heavy Metal Contents in Freshwater Fishes of the Mankyung River (만경강 담수어중 중금속 함량에 관한 연구)

  • Kim, Nam-Song
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.121-131
    • /
    • 1988
  • This study was performed to investigate the heavy metal contents of freshwater fishes. The samples of 24 species were collected at 7 areas located on the Mankyung River during September in 1987. And then the contents of lead, cadmium, copper and zine were analyzed by atomic absorption spectrophotometer. The results were summarized as follows ; 1. The mean value of lead, cadmium, and copper contents of fishes collected in the downstream were significantly higher than those of upstream. 2. The mean lead content of C. auratus was the highest $1.50{\pm}0.98{\mu}g/g$ in viscera and statistically significant difference from muscle content. 3. The mean cadmium content of C. auratus was the highest $0.087{\pm}0.054{\mu}g/g$ in viscera and significantly higher than that of muscle. 4. In the copper contents, the viscera of C. auratus was the highest $5.25{\pm}0.94{\mu}g/g$ and significantly higher than that of muscle, skeleton and gill. 5. The mean value of zinc content of C. auratus was shown the order of gill, skeleton, viscera and muscle.

  • PDF

Characteristics of Precipitation and Temperature at Ulleung-do and Dok-do, Korea for Recent Four Years(2005~2008) (최근 4년간(2005~2008) 울릉도와 독도의 강수 및 기온 특성)

  • Lee, Young-Gon;Kim, Baek-Jo;Park, Gil-Un;Ahn, Bo-Young
    • Journal of Environmental Science International
    • /
    • v.19 no.9
    • /
    • pp.1109-1118
    • /
    • 2010
  • Characteristics of precipitation and temperature in Ulleung-do and Dok-do were analyzed with hourly accumulated precipitation and mean temperature data obtained from Automatic Weather System(AWS) for latest four years(2005~2008). In Ulleung-do, total annual mean precipitation for this period is 1,574.4 mm, which shows larger amount than 1434.2 mm of whole Korean peninsula for latest 10 years(1999~2008) and 1,236.2 mm at Ulleung-do on common years(1971~2000), shows that the trend of precipitation gradually increases during the recent years. This amount is also 1.4 times larger than the total annual mean precipitation of 660.1 mm in Dok-do. Mean precipitation intensity(mm $h^{-1}$) at each time of a day in each month at Ulleung-do represents that the maximum values larger than $3.0\;mm\;h^{-1}$ were shown in May and on 0200 LST, whereas these were found in August and 0700 LST with $3.1\;mm\;h^{-1}$ in Dok-do. The difference of the precipitation amount and its intensity between Uleung-do and Dok-do is explained by the topological effect came from each covering area, and this fact is also identified from similar comparison of the precipitation characteristics for the islands in West Sea. The annual mean temperature of $14.0^{\circ}C$ in Dok-do is $1.2^{\circ}C$ higher than that of $12.8^{\circ}C$ in Ulleung-do. Trends of monthly mean temperature in both islands are shown to increase for the observed period.

Quality of Life among Breast Cancer Patients In Malaysia

  • Ganesh, Sri;Lye, Munn-Sann;Lau, Fen Nee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1677-1684
    • /
    • 2016
  • Background: Among the factors reported to determine the quality of life of breast cancer patients are socio-demographic background, clinical stage, type of treatment received, and the duration since diagnosis. Objective: The objective of this study was to determine the quality of life (QOL) scores among breast cancer patients at a Malaysian public hospital. Materials and Methods: This cross-sectional study of breast cancer patients was conducted between March to June 2013. QOL scores were determined using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30) and its breast cancer supplementary measure (QLQ-BR23). Both the QLQ-C30 and QLQ-BR23 assess items from functional and symptom scales. The QLQ-C30 in addition also measures the Global Health Status (GHS). Systematic random sampling was used to recruit patients. Results: 223 breast cancer patients were recruited with a response rate of 92.1%. The mean age of the patients was 52.4 years (95% CI = 51.0, 53.7, SD=10.3). Majority of respondents are Malays (60.5%), followed by Chinese (19.3%), Indians (18.4%), and others (1.8%). More than 50% of respondents are at stage III and stage IV of malignancy. The mean Global Health Status was 65.7 (SD = 21.4). From the QLQ-C30, the mean score in the functioning scale was highest for 'cognitive functioning' (84.1, SD=18.0), while the mean score in the symptom scale was highest for 'financial difficulties' (40.1, SD=31.6). From the QLQ-BR23, the mean score for functioning scale was highest for 'body image' (80.0, SD=24.6) while the mean score in the symptom scale was highest for 'upset by hair loss' (36.2, SD=29.4). Two significant predictors for Global Health Status were age and employment. The predictors explained 10.6% of the variation of global health status ($R^2=0.106$). Conclusions: Age and employment were found to be significant predictors for Global Health Status (GHS). The Quality of Life among breast cancer patients reflected by the GHS improves as age and employment increases.