References
- Bland, J. M., & Altman, D. G. (1986). Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, 8, 307-310.
- Brooks, S., Khan, A., Stoica, D., Griffith, J., Friedeman, L., Mukherji, R., et al. (1998). Reduction in vancomycin-resistant Enterococcus and Clostridium difficile infections following change to tympanic thermometers. Infection Control and Hospital Epidemiology, 19, 333-336. http://dx.doi.org/10.1086/647824
- Carroll, D., Finn, C., Judge, B., Gill, S., & Sawyer, J. (2004). A comparison of measurements from a temporal artery thermometer and a pulmonary artery catheter thermistor. American Journal of Critical Care, 13, 258.
- Cattaneo, C. G., Frank, S. M., Hesel, T. W., El-Rahmany, H. K., Kim, L. J., & Tran, K. M. (2000). The accuracy and precision of body temperature monitoring methods during regional and general anesthesia. Anesthesia and Analgesia, 90, 938-945. http://dx.doi.org/10.1097/00000539-200004000-00030
- Craig, J. V., Lancaster, G. A., Taylor, S., Williamson, P. R., & Smyth, R. L. (2002). Infrared ear thermometry compared with rectal thermometry in children: A systematic review. Lancet, 360, 603-609. http://dx.doi.org/10.1016/S0140-6736(02)09783-0
- Giuliano, K. K., Giuliano, A. J., Scott, S. S., MacLachlan, E., Pysznik, E., Elliot, S., et al. (2000). Temperature measurement in critically ill adults: A comparison of tympanic and oral methods. American Journal of Critical Care, 9, 254-261.
- Greenes, D. S., & Fleisher, G. R. (2001). Accuracy of a noninvasive temporal artery thermometer for use in infants. Archives Pediatrics & Adolescent Medicine, 155, 376-381. https://doi.org/10.1001/archpedi.155.3.376
- Hwang, J. S., & Sohng, K. Y. (1997). Comparison of rectal temperature with axillary and tympanic temperature. Journal of Korean Academy of Fundamentals of Nursing, 4, 351-358.
- Kenney, R. D., Fortenberry, J. D., Surratt, S. S., Ribbeck, B. M., & Thomas, W. J. (1990). Evaluation of an infrared tympanic membrane thermometer in pediatric patients. Pediatrics, 85, 854-858.
- Kimberger, O., Cohen, D., Illievich, U., & Lenhardt, R. (2007). Temporal artery versus bladder thermometry during perioperative and intensive care unit monitoring. Anesthesia and Analgesia, 105, 1042-1047. http://dx.doi.org/10.1213/01.ane.0000281927.88935.e0
- Kistemaker, J. A., Den Hartog, E. A., & Daanen, H. A. (2006). Reliability of an infrared forehead skin thermometer for core temperature measurements. Journal of Medical Engineering & Technology, 30, 252-261. http://dx.doi.org/10.1080/03091900600711381
- Koo, H. Y., & Son, J. T. (2005). Comparison of inguinal, rectal, axillary, and tympanic temperature in newborns. Korean Journal of Child Health Nursing, 11, 203-210.
- Koo, S. H., Jeong, M. S., Kim, K. A., Ko, S. Y., Lee, Y. K., & Shin, S. M. (2003). Comparison of body temperature measured by non-contact temporal artery thermometer with those by other methods in neonates. Korean Journal of Perinatology, 14, 409-415.
- Korean Society for the Study of Obesity. (2006, February). The Asia-Pacific perspective: Redefining obesity and its treatment. Seoul: Author. (Original work published 2000).
- Lawson, L., Bridges, E. J., Ballou, I., Eraker, R., Greco, S., Shively, J., et al. (2007). Accuracy and precision of noninvasive temperature measurement in adult intensive care patients. American Journal of Critical Care, 16, 485-496.
- Lee, W. H., & Jung, S. P. (1995). The validity of the tympanic membrane thermometer in detecting fever of the children. Korean Journal of Family Medicine, 16, 531-536.
- Marable, K., Shaffer, L. E., Dizon, V., & Opalek, J. M. (2009). Temporal artery scanning falls short as a secondary, noninvasive thermometry method for trauma patients. Journal of Trauma Nursing, 16, 41-47. http://dx.doi.org/10.1097/01.JTN.0000348069.71593.9d
- Myny, D., De Waele, J., Defloor, T., Blot, S., & Colardyn, F. (2005). Temporal scanner thermometry: A new method of core temperature estimation in ICU patients. Scottish Medical Journal, 50, 15-18. https://doi.org/10.1177/003693300505000106
- Park, C. W., & Park, S. N. (2007). Development of standard and improvement of reliability in body temperature measurement. Journal of the Korean Society for Precision Engineering, 24(9), 32-36.
- Potter, P. A., Perry, A. G., & Stockert, P. (2010). Basic nursing. St. Louis: Mosby Co
- Ronneberg, K., Roberts, W. O., McBean, A. D., & Center, B. A. (2008). Temporal artery temperature measurements do not detect hyperthermic marathon runners. Medicine and Science in Sports and Exercise, 40, 1373-1375. http://dx.doi.org/10.1249/MSS.0b013e31816d65bb
- Shiraki, K., Konda, N., & Sagawa, S. (1986). Esophageal and tympanic temperature responses to core blood temperature changes during hyperthermia. Journal of Applied Physiology, 61, 98-102. https://doi.org/10.1152/jappl.1986.61.1.98
- Siberry, G. K., Diener-West, M., Schappell, E., & Karron, R. A. (2002). Comparison of temple temperatures with rectal temperature in children under two years of age. Clinical Pediatrics, 41, 405-414. http://dx.doi.org/10.1177/000992280204100605
- Sohng, K. Y., Park, H. S., Hong, Y. H., Yun, E. J., Lee, K. Y., Cho, B. H., et al. (2009). Fundamentals of nursing. Seoul: Soomoonsa.
- Suleman, M. I., Doufas, A. G., Akca, O., Ducharme, M., & Sessler, D. I. (2002). Insufficiency in a new temporal-artery thermometer for adult and pediatric patients. Anesthesia and Analgesia, 95, 67-71. http://dx.doi.org/10.1097/00000539-200207000-00012
- Yoo, J. H., & Jo, H. S. (2009). Comparison of tympanic and axillary temperatures. Journal of Korean Academy of Fundamentals of Nursing, 16, 162-170.
- Yun, K. W., & Lim, I. S. (2005). A study for accuracy and usefulness of tympanic membrane and forehead thermometers. Korean Journal of Pediatrics, 48, 820-825.
Cited by
- 전정맥 전신마취하(下) 복강경 수술환자의 부위별 심부체온의 변화 평가 vol.22, pp.4, 2012, https://doi.org/10.7739/jkafn.2015.22.4.379
- 이마 체온의 진단정확도 vol.24, pp.2, 2012, https://doi.org/10.22650/jkcnr.2018.24.2.227
- Smart Patch for Skin Temperature: Preliminary Study to Evaluate Psychometrics and Feasibility vol.21, pp.5, 2012, https://doi.org/10.3390/s21051855