• 제목/요약/키워드: ($(Gd\

검색결과 1,156건 처리시간 0.026초

인위적 기원 가돌리늄(gadolinium)의 해양 유입 연구 동향 및 향후 연구 방향 (Anthropogenic Gadolinium (Gd) Inputs into the Ocean: Review and Future Direction)

  • 김인태
    • Ocean and Polar Research
    • /
    • 제43권3호
    • /
    • pp.165-178
    • /
    • 2021
  • Gadolinium (Gd), one of a rare earth element (REE), has been widely used worldwide since the 1980s, as a resource material for contrast agents injected into examiners of magnetic resonance imaging (MRI) test. The organic complexed form of Gd shows an extremely stable behavior in natural environment (water), so is known that the artificial Gd from medical uses is not removed from the waste water treatment plant (WWTP) and eventually introduced into the ocean through the estuary. Since the 1990s, some previous studies have often been conducted on Gd anomalies in natural water and their effects an artificial origin from land or metropolitan areas, but little research has been potential impacts on the ocean water. In this paper, we review and introduce recent studies related to Gd anomaly in natural water and related marine effects, and also propose the future research directions.

트레드밀 운동이 고지혈증 흰쥐의 혈액 성분과 항산화효소 및 활성산소에 미치는 영향 (The Effects of Treadmill Exercise on Blood components, Antioxidant enzymes and Reactive Oxygen in Hyperlipidemic Rats)

  • 정병옥;장상훈;방현수
    • 대한물리의학회지
    • /
    • 제8권1호
    • /
    • pp.71-78
    • /
    • 2013
  • PURPOSE: The purpose of this study was to investigate the effects of treadmill exercise on blood components and antioxidant system in hyperlipidemic rats. METHODS: Three weeks old male rats were randomly assigned into General diet(GD, n=10), High fat Diet(HD, n=10), and High fat diet+Treadmill exercise(HDT, n=10) groups. Treadmill exercise consisted of the treadmill running 5 times per week during 6 weeks(30 min/time for first 3 weeks and 60 min/time the other 3 weeks). RESULTS: The levels of triglyceride and total cholesterol were increased in HD group compared with GD group, and recovered to level of GD group by treadmill exercise(p<.05). Plasma glucose and insulin concentrations were increased in HD group compared with GD group, and recovered to level of GD group by treadmill exercise(p<.05). Glutathione(GSH) and glutathione reductase(GRD) concentrations were decreased in HD group compared with GD group, and these decreases returned to the level of GD group by treadmill exercise(p<.05). Xanthine oxidase(XO) and malondialdehyyde (MDA) concentrations were increased in HD group compared with GD group, and these increases retuned to the level of GD group by treadmill exercise(p<.05). CONCLUSION: This study showed that treadmill exercise application were effective treatment strategy on hyperlipidemia. Therefore, it could be considered as a treatment method in the patients with hyperlipidemia disease. Treadmill exercise, Hyperlipidemia, Blood components.

SiO2 나노 입자로 코팅된 형광체 분말을 이용한 Gd2O3 : (Li, Eu) 필름 제조 (Synthesis of Gd2O3 : (Li, Eu) Films using Phosphor Powders Coated with SiO2 Nano Particles)

  • 박중철
    • 대한화학회지
    • /
    • 제47권6호
    • /
    • pp.619-624
    • /
    • 2003
  • 졸겔법을 사용하여 $Gd_{1.9-x}Li_{0.1}Eu_xO_3$(x=0.02, 0.05, 0.08, 0.12) 형광체 분말을 합성하였다. 형광체 입자의 표면을 나노 크기의 $SiO_2$(입자크기${\thickapprox}30 nm$)로 코팅한 후 스핀-코팅법으로 유리 기판에 형광체 막을 제작하였다. 유리의 연화온도인 $700^{\circ}C$ 부근에서 융착 되는 $SiO_2$ 나노 입자들에 의해 $Gd_{1.9-x}Li_{0.1}Eu_xO_3$ 입자들은 유리 기판 표면 위에 강하게 융착 되었다(>9H, 연필 경도계). 본 연구에서 채택한, 형광체 막을 제조하는 간단하고 비용이 저렴한 이 방법은 디스플레이장치의 응용 분야에 적용될 수 있을 것으로 생각한다.

균일침전법으로 제조한 플라즈마 디스플레이용 적색 형광체 (Y,Gd)$_2$O$_3$: Eu의 발광특성 (Photoluminescent properties of red phosphor (Y,Gd)$_2$O$_3$: Eu for plasma display panel synthesized by homogeneous precipitation method)

  • 김유혁;김좌연
    • 한국결정성장학회지
    • /
    • 제10권6호
    • /
    • pp.400-406
    • /
    • 2000
  • 전구체인 (Y,Gd,Eu)(OH)$CO_3$.$H_2O$$900^{\circ}C$에서 열처리하여 얻은 분말을 플라즈마 디스플레이용 적색 형광체 $(Y,Gd)_2O_3$: Eu를 제조하기 위하여 이용하였다. 크기가 대략 1$\mu\textrm{m}$의 구형 형광체 $(Y,Gd)_2O_3$: Eu는 위의 분말에 소량의 융제를 첨가하여 $1350^{\circ}C$에서 2시간 소성하면 얻을 수 있다. 제조된 형광체의 발광 스펙트럼은 여기원이 254 nm와 147 nm인 파장에서 측정하였으며 최적인 활성제의 농도는 254 nm 하에서는 15 몰 %, 147 nm에서는 10 몰 %로 결정되었다. 또한 발광세기를 비교한 결과 BaCO$_3$, $AlF_3$$Li_3PO_4$$BaCO_3$가 가장 우수한 것으로 나타났다. 최적화된 형광체 $(Y,Gd)_2O_3$: Eu의 상대 휘도 및 색좌표는 상용품인 $Y_2O_3$: Eu 보다 개선되는 것으로 평가되고 있다.

  • PDF

In-vitro investigation of the mechanical friction properties of a computer-aided design and computer-aided manufacturing lingual bracket system under diverse tooth displacement condition

  • Kim, Do-Yoon;Ha, Sang-Woon;Cho, Il-Sik;Yang, Il-Hyung;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제49권2호
    • /
    • pp.73-80
    • /
    • 2019
  • Objective: The purpose of this study was to compare the static (SFF) and kinetic frictional forces (KFF) of a computer-aided design and computer-aided manufacturing lingual bracket (CAD/CAM-LB) with those of conventional LB (Con-LB) and Con-LB with narrow bracket width (Con-LB-NBW) under 3 tooth displacement conditions. Methods: The samples were divided into 9 groups according to combinations of 3 LB types (CAD/CAM-LB [Incognito], Con-LB [7th Generation, 7G], and Con-LB-NBW [STb]) with 3 displacement conditions (no displacement [control], maxillary right lateral incisor with 1-mm palatal displacement [MXLI-PD], and maxillary right canine with 1-mm gingival displacement [MXC-GD]; n = 6/group). While drawing a 0.016-inch copper or super-elastic nickel-titanium archwire with 0.5 mm/min for 5 minutes in a chamber maintained at $36.5^{\circ}C$, SFF and KFF were measured. The Kruskal-Wallis method with Bonferroni correction was performed. Results: The Incognito group demonstrated the highest SFF, followed by the 7G and STb groups ([STb-control, STb-MXLI-PD, Stb-MXC-GD] < [7G-MXC-GD, 7G-MXLI-PD, 7G-control] < [Incognito-MXLI-PD, Incognito-control, Incognito-MXC-GD]; p < 0.001). However, there were no significant differences in SFF among the 3 displacement conditions within each bracket group. Within each displacement condition, the Incognito group demonstrated the highest KFF, followed by the 7G and STb groups ([STb-control, STb-MXLI-PD] < Stb-MXC-GD < 7G-MXLI-PD < [7G-control, 7G-MXC-GD] < [7G-MXC-GD, Incognito-MXLI-PD, Incognito-control] < [Incognito-control, Incognito-MXC-GD]; p < 0.001). MXC-GD exhibited higher KFFs than MXLI-PD in the same bracket group. Conclusions: The slot design and ligation method of the CAD/CAM-LB system should be modified to reduce SFF and KFF during the leveling/alignment stage.

Thermal stability, magnetic and magnetocaloric properties of Gd55Co35M10 (M = Si, Zr and Nb) melt-spun ribbons

  • Jiao, D.L.;Zhong, X.C.;Zhang, H.;Qiu, W.Q.;Liu, Z.W.;Ramanujan, R.V.
    • Current Applied Physics
    • /
    • 제18권12호
    • /
    • pp.1523-1527
    • /
    • 2018
  • The thermal stability, magnetic and magnetocaloric properties of $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) melts-pun ribbons were studied. The relatively high reduced glass transition temperature ($T_{x1}/T_m$ > 0.60) and low melting point ($T_m$) resulted in excellent glass forming ability (GFA). The Curie temperatures ($T_C$) of melt-spun amorphous ribbons $Gd_{55}Co_{35}M_{10}$ for M = Si, Zr and Nb were 166, 148 and 173 K, respectively. For a magnetic field change of 2 T, the values of maximum magnetic entropy change $(-{\Delta}S_M)^{max}$ for $Gd_{55}Co_{35}Si_{10}$, $Gd_{55}Co_{35}Zr_{10}$ and $Gd_{55}Co_{35}Nb_{10}$ were found to be 2.86, 4.28 and $4.05J\;kg^{-1}K^{-1}$, while the refrigeration capacity (RC) values were 154, 274 and $174J\;kg^{-1}$, respectively. The $RC_{FWHM}$ values of amorphous alloys $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) are comparable to or larger than that of $LaFe_{11.6}Si_{1.4}$ crystalline alloy. Large values of $(-{\Delta}S_M)^{max}$ and RC along with good thermal stability make $Gd_{55}Co_{35}M_{10}$ (M = Si, Zr and Nb) amorphous alloys be potential materials for magnetic cooling operating in a wide temperature range from 150 to 175 K, e.g., as part of a gas liquefaction process.

An approach to minimize reactivity penalty of Gd2O3 burnable absorber at the early stage of fuel burnup in Pressurized Water Reactor

  • Nabila, Umme Mahbuba;Sahadath, Md. Hossain;Hossain, Md. Towhid;Reza, Farshid
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3516-3525
    • /
    • 2022
  • The high capture cross-section (𝜎c) of Gadolinium (Gd-155 and Gd-157) causes reactivity penalty and swing at the initial stage of fuel burnup in Pressurized Water Reactor (PWR). The present study is concerned with the feasibility of the combination of mixed burnable poison with both low and high 𝜎c as an approach to minimize these effects. Two considered reference designs are fuel assemblies with 24 IBA rods of Gd2O3 and Er2O3 respectively. Models comprise nuclear fuel with a homogeneous mixture of Er2O3, AmO2, SmO2, and HfO2 with Gd2O3 as well as the coating of PaO2 and ZrB2 on the Gd2O3 pellet's outer surface. The infinite multiplication factor was determined and reactivity was calculated considering 3% neutron leakage rate. All models except Er2O3 and SmO2 showed expected results namely higher values of these parameters than the reference design of Gd2O3 at the early burnup period. The highest value was found for the model of PaO2 and Gd2O3 followed by ZrB2 and HfO2. The cycle burnup, discharge burnup, and cycle length for three batch refueling were calculated using Linear Reactivity Model (LRM). The pin power distribution, energy-dependent neutron flux and Fuel Temperature Coefficient (FTC) were also studied. An optimization of model 1 was carried out to investigate effects of different isotopic compositions of Gd2O3 and absorber coating thickness.

Gadolinium- and lead-containing functional terpolymers for low energy X-ray protection

  • Zhang, Yu-Juan;Guo, Xin-Tao;Wang, Chun-Hong;Lu, Xiang An;Wu, De-Feng;Zhang, Ming
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4130-4136
    • /
    • 2021
  • By polymerization of gadolinium methacrylate (Gd (MAA)3), lead methacrylate (Pb(MAA)2) and methyl methacrylate (MMA), Gd and Pb were chemically bonded into polymers. The X-ray shielding performance was evaluated by Monte Carlo simulation method, and the results showed that the more metal functional organic monomer, the better the shielding performance of terpolymers. When the X-ray energy is 65 keV, Gd (MAA)3-containing polymers have better shielding performance than Pb(MAA)2-containing polymers. Gd could compensate for the weak absorption region of Pb. Therefore, polymers containing both Gd and Pb enhanced shielding efficiency against X-ray in various low-energy ranges. For obtaining terpolymers with uniform monomer compositions, the relationship between the monomer composition of the terpolymers and the conversion level was optimized by calculating the reactivity ratios. The value of reactivity ratios of r (Gd (MAA)3/Pb(MAA)2), r (Pb(MAA)2/Gd (MAA)3), r (Gd (MAA)3/MMA), r (MMA/Gd (MAA)3), r (Pb(MAA)2/MMA) and r (MMA/Pb(MAA)2) was 0.483, 0.004, 0.338, 2.508, 0.255, 0.029. The terpolymers with uniform monomer composition could be obtained by controlling the monomer compositions or conversion levels. The results can provide new radiation protection materials and contribute to the improvement in nuclear safety.

Role of Contrast-Enhanced Ultrasound as a Second-Line Diagnostic Modality in Noninvasive Diagnostic Algorithms for Hepatocellular Carcinoma

  • Hyo-Jin Kang;Jeong Min Lee;Jeong Hee Yoon;Joon Koo Han
    • Korean Journal of Radiology
    • /
    • 제22권3호
    • /
    • pp.354-365
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of contrast-enhanced ultrasound (CEUS) and its role as a second-line imaging modality after gadoxetate-enhanced MRI (Gd-EOB-MRI) in the diagnosis of hepatocellular carcinoma (HCC) among at risk observations. Materials and Methods: We prospectively enrolled participants at risk of HCC with treatment-naïve solid hepatic observations (≥ 1 cm) of Liver Imaging Reporting and Data System (LR)-3/4/5/M during surveillance and performed Gd-EOB-MRI. A total of one hundred and three participants with 103 hepatic observations (mean size, 28.2 ± 24.5 mm; HCCs [n = 79], non-HCC malignancies [n = 15], benign [n = 9]; diagnosed by pathology [n = 57], or noninvasive method [n = 46]) were included in this study. The participants underwent CEUS with sulfur hexafluoride. Arterial phase hyperenhancement (APHE) and washout on Gd-EOB-MRI and CEUS were evaluated. The distinctive washout in CEUS was defined as mild washout 60 seconds after contrast injection. The diagnostic ability of Gd-EOB-MRI and of CEUS as a second-line modality for HCC were determined according to the European Association for the Study of the Liver (EASL) and the Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) guidelines. The diagnostic abilities of both imaging modalities were compared using the McNemar's test. Results: The sensitivity of CEUS (60.8%) was lower than that of Gd-EOB-MRI (72.2%, p = 0.06 by EASL; 86.1%, p < 0.01 by KLCA-NCC); however, the specificity was 100%. By performing CEUS on the inconclusive observations in Gd-EOB-MRI, HCCs without APHE (n = 10) or washout (n = 12) on Gd-EOB-MRI further presented APHE (80.0%, 8/10) or distinctive washout (66.7%, 8/12) on CEUS, and more HCCs were diagnosed than with Gd-EOB-MRI alone (sensitivity: 72.2% vs. 83.5% by EASL, p < 0.01; 86.1% vs. 91.1% by KCLA-NCC, p = 0.04). There were no false-positive cases for HCC on CEUS. Conclusion: The addition of CEUS to Gd-EOB-MRI as a second-line diagnostic modality increases the frequency of HCC diagnosis without changing the specificities.

Gustatory dysfunction in patients with olfactory dysfunction and the associated factors

  • M.-S. Rha;H.-J. Cho;J.-H. Yoon;S.J. Moon;C.-H. Kim
    • Journal of Rhinology
    • /
    • 제60권3호
    • /
    • pp.200-206
    • /
    • 2022
  • Background: Little is known about the occurrence of gustatory dysfunction (GD) in relation to different aetiologies of olfactory dysfunction (OD) as assessed by psychophysical chemosensory tests. The aim of this study was to analyse gustatory function in patients with OD and to investigate clinical factors associated with GD. Methods: A total of 742 individuals who underwent both olfactory and gustatory function tests at a tertiary medical centre from November 2019 to March 2021 were retrospectively enrolled. Olfactory and gustatory function were assessed by the YSK olfactory and gustatory function tests, respectively. Patients with OD were classified into four groups according to the aetiology: sinonasal disease, post-infection OD (PIOD), post-traumatic OD (PTOD), and others. Secondary outcomes included age, sex, smoking history, and alcohol history. Results: Among the 488 patients with OD, 93 (19.1%) showed GD and 395 (80.9%) had normal gustatory function. Only 25 (9.8%) among 254 individuals with normosmia showed GD. Analyses of these frequencies revealed a significant association between OD and GD. In addition, the taste score was significantly lower in patients with OD than individuals with normosmia. The frequency of GD was significantly higher in patients with PTOD (53.6%) than in those with OD of other aetiologies (sinonasal disease, 6.7%; PIOD, 13.0%; others, 24.4%). In the multivariate analysis, age ≥55 years and PTOD were associated with a high frequency of GD among patients with OD. Conclusions: The current study show that GD is significantly associated with OD. In particular, GD is more common in patients with PTOD than in those with OD of other aetiologies.