• Title/Summary/Keyword: $m_v$ method

Search Result 2,704, Processing Time 0.03 seconds

THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS (타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화)

  • Hwang Yun-Tae;Lee Sung-Bok;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

The Effects of Hypercapnia and High Flow on Cerebral Metabolism During Cardiopulmonary Bypass (심폐바이패스 시 고탄산분압과 고관류법이 뇌대사에 미치는 영향)

  • 강도균;최석철;윤영철;최국렬;정신현;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.472-482
    • /
    • 2003
  • Recent studies have demonstrated that cerebral desaturation during rewarming period of CPB was associated with postoperative neurologic dysfunction. The prevention of cerebral desaturation during CPB may reduce the incidences of neurologic and neuropsychological complications. The present study was prospectively undertaken to compare the clinical effects between two strategies (hypercapnic CPB and high flow CPB) to prevent cerebral desaturation for establishing a proper CPB technique. Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized into either hypercapnic (Pa$CO_2$ 45~50mmHg, n=18) or high flow group (flow rate 2.75 L/ $m^2$/min and Pa$CO_2$ 35~40mmHg, n=18) during rewarming period of CPB. In each patient, middle cerebral artery blood flow velocity ( $V_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v) $O_2$), modified cerebral metabolic rate for oxygen (MCMR $O_2$), cerebral oxygen transport rate ( $T_{E}$ $O_2$), incidence of cerebral desaturation (internal jugular bulb blood oxygen saturation $\leq$ 50%), increased rate of S-100 $\beta$ concentration, and arterial and internal jugular bulb blood gas were measured during the five phases of the operation; Pre-CPB, CPB-10 min (steady-state CPB, nasopharyngeal temperature 29~3$0^{\circ}C$), Rewarm-1 (rewarming phase, nasopharyngeal temperature 33$^{\circ}C$), Rewarm-2 (nasopharyngeal temperature 37$^{\circ}C$), and CPB-off. Incidence of postoperative delirium and duration were assessed in all patients. All variables were compared between the two groups. Result: $V_{MCA}$ (157.88$\pm$10.87 vs 120.00$\pm$6.18%, p=0.006), internal jugular bulb $O_2$ saturation (68.01$\pm$2.75 vs 61.28$\pm$2.87%, p=0.03) and $O_2$ tension (41.01$\pm$2.25 vs 32.02$\pm$ 1,67 mmHg, p=0.03), and $T_{E}$ $O_2$(110.84$\pm$7.41 vs 81.15$\pm$8.11%, p=0.003) at rewarming periods were higher in the hypercapnic group than in the high flow group. C(a-v) $O_2$ (4.0$\pm$0.30 vs 4.84$\pm$0.38 mg/dL, p=0.04), COE (0.36$\pm$0.03 vs 0.42$\pm$0.03, p=0.04), increased rate of S- 100$\beta$ (391.67$\pm$23.40 vs 940.0$\pm$17.02%, p=0.003), and incidence of cerebral desaturation (2 vs 4 patients, p=0.04) at rewarming periods, and duration of postoperative delirium (18 vs 34 hr, p=0.02) were low in the hypercapnic group compared to the high flow group. Conclusion: These results indicate that hypercapnic CPB may provide relatively diminished cerebral injury and beneficial effects for cerebral metabolism relatively compared to high flow CPB.low CPB.

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF

An Equation to Estimate Steady-State Seepage Rate of Rockfill Dam (사력댐의 정상상태 침투량 예측식)

  • Lee, Jong-Wook;Lim, Heui-Dae
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.10
    • /
    • pp.69-80
    • /
    • 2011
  • In this study unsaturated seepage analysis of 8 large rockfill dam managed by Korea Water Resources Corporation, were carried out, and the seepage rate of rockfill dam was analyzed by changing reservoir water level, shape, saturated and unsaturated seepage properties of core zone to present an equation to estimate steady-state seepage rate of rockfill dam. This equation considers unsaturated seepage flow and is applicable to domestic large scale Rockfill dam with the height of more than 50m. Estimated values by the proposed equation are greater than those by the method of Sakamoto (1998), which does not consider unsaturated seepage flow. The difference of estimated values increases with the lower reservoir water level and decreases with the higher reservoir water level. We can be sure that the comparison between the measured seepage rate and the estimated seepage rate by the proposed equation for the existing rockill dam was well-matched. The proposed equation is close to the actual phenomenon compared with the existing equations (Sakamoto, 1998; Chapuis and Aubertin, 2001) because it is based on the results of unsaturated seepage analysis of dams, has upstream and downstream slopes in the range of 1Vertical: (0.2~0.3)Horizontal.

A Study on Catalytic Activity of Oxygen Reduction Reaction and Performance of PEMFC using Pt/C Synthesized by Modified Polyol (수정된 폴리올법으로 합성된 Pt/C를 이용한 산소환원반응성 및 고분자전해질 연료전지 성능 연구)

  • Yang, Jongwon;Chu, Cheonho;Kwon, Yongchai
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.157-162
    • /
    • 2014
  • In this research, we investigate electrical performance and electrochemical properties of carbon supported Pt (Pt/C) that is synthesized by polyol method. With the Polyol_Pt/C that is adopted for oxygen reduction reaction (ORR) as cathode of proton exchange membrane fuel cells (PEMFCs), their catalytic activity and ORR performance and electrical performance are estimated and compared with commercial Pt/C(Johnson Mattey) catalyst. Their electrochemically active surface (EAS) area are measured by cyclic voltammetry (CV), respectively. On the other hand, regarding ORR activity and electrical performance of the catalysts, (i) linear sweeping voltammetry by rotating disk electrode and (ii) PEMFC single cell tests are used. The CV measurement demonstrate EAS of Polyol_Pt/C is compared with commercial JM_Pt/C. In case of Polyol_Pt/C, its half-wave potential, kinetic current density are excellent. Based on data obtained by half-cell test, when PEMFC single cell tests are carried out, current density measured at 0.6V and maximum power density of the PEMFC single cell employing Polyol_Pt/C are better than those employing commercial Pt/C. Conclusively, Polyol_Pt/C synthesized by modified polyol process shows better ORR catalytic activity and PEMFC performance than other catalysts.

Roadside Landslide and Ditch Erosion in Mountain Forest Road (산악지림도(山岳地林道)의 노견(路肩) 사면붕괴(斜面崩壞)와 측구침식(側溝浸蝕)에 관(關)한 연구(硏究))

  • Ma, Sang Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.76 no.2
    • /
    • pp.161-168
    • /
    • 1987
  • Forest road (10 Km) constructed for the demonstrational purpose by Forest Work Training Center (F.T.C.) in 1984 was partly damaged through the roadside landside and ditch erosion by the typhoon in 1986. The causes were investigated to apply for protecting against the damage of mountain forest road. The damaging length caused by roadside landside is around 3% out of total length of 10 Km forest road, and mostly coming from the curve road filled up more than 10 m slope length on the concave mountain slope, partly from the foot of fillslope along the ever-following valley and from the both side of fillslope under the outlet of culvert with ever-flowing water. In case of ditch erosion, the big damage at V-type ditch is coming from the overflow of valley water flowing down along the inside slope. Other problem is also showing in the steepness of longitudial gradient, which is felt as a problem in road to be constructed under more than 10 persent of gradient. Other cause of ditch erosion is coming from the bury of sand basin (water collecting wall) by the debris in small diameter culvert zone, namely less than 400mm, in diameter and by the soil mass slumped down from steep wall slope. From above results the causes of F.T.C. model road damage is showing to come from no-following the general guide or little experience to protect against the forest road damage. When improved above mentioned mistakes, F.T.C. Method of mountain forest road type could be developed as a model of Mountain forest road.

  • PDF

Classification and Stand Characteristics of Subalpine Forest Vegetation at Hyangjeukbong and Jungbong in Mt. Deogyusan (덕유산 향적봉 및 중봉 아고산대의 산림식생유형분류와 임분 특성)

  • Han, Sang Hak;Han, Sim Hee;Yun, Chung Weon
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.1
    • /
    • pp.48-62
    • /
    • 2016
  • This study was conducted to classify forest vegetation structure and stand feature of Mt. Deogyusan National Park from Hyangjeukbong to Jungbong, 48 plots were surveyed. The type classification of the vegetation structure was performed with Z-M phytosociological method. As a result, Quercus mongolica community group was classified into the Picea jezoensis community, Carpinus cordata community and Tilia amurensis community in community unit. P. jezoensis community was subdivided into Deutzia glabrata group and Viburnum opulus var. calvescens group in group unit. D. glabrata group was subdivided into Acer mandshuricum subgroup and Ribes mandshuricum subgroup and V. opulus var. calvescens group was subdivided into Hemerocallis dumortieri subgroup and Prunus padus subgroup in subgroup unit. In the result of estimating the importance value, it constituted Q. mongolica (23.9%), Abies koreana (14.7%), Taxus cuspidata (10.2%), P. jezoensis (8.2%) and Betula ermanii (7.4%) in tree layer. It constituted Acer komarovii (18.6%), Acer pseudosieboldianum (18.4%) and Q. mongolica (8.9%) in subtree layer. It constituted Rhododendron schlippenbachii (20.7%), A. pseudosieboldianum (17.4%) and Symplocos chinensis (8.5%) in shrub layer. Indicator species analysis of vegetation unit 1 was consisted of Hydrangea serrata, Fraxinus mandshurica and D. glabrata that species prefer moist valley in subalpine or rocks. In the results of analyzing the species diversity, vegetation unit 1, 4 and 5 represented that there were different and complex local distributions. As in the similarity between the vegetation units, the vegetation units 1, 2, 3 and 4 represented high with 0.5 or above. It represented that there wasn't no differences on composition species in vegetation units.

Survey of Manager's Perception of Slaughter House for Poultry Grading (닭고기 품질등급제에 대한 도계장 관리자 설문 조사)

  • Chae H. S.;Yoo Y. M.;Ahn C. N.;Ham J. S.;Jeong S. G.;Lee J. M.;Choi Y. I.
    • Korean Journal of Poultry Science
    • /
    • v.32 no.2
    • /
    • pp.107-112
    • /
    • 2005
  • This study was conducted to establish a comprehensive grading guideline for poultry. Guidelines for sampling size and grading were determined on the basis of survey data obtained from chicken processing house. Results were summarized as follows : For application unit, most chicken processing house preferred lot unit to farm unit. Most processing house did not want the total survey method, but selection sampling. At the beginning of the grading system, chicken processing house wanted to apply the system to a particular lots for which the company requests. There were much suggestions for grading not only portion meat, but also whole chicken. Bigger processing house preferred no. $8\~12$ to be graded. Most of large-scale processing houses used more than 81 volts for stunning and cooling tanks by soaking. For shipping chicken, Large-scale processing houses used both individual and box packing while small ones only used box packing.

Manual Liquid Based Cytology in Primary Screening for Cervical Cancer - a Cost Effective Preposition for Scarce Resource Settings

  • Nandini, N.M.;Nandish, S.M.;Pallavi, P.;Akshatha, S.K.;Chandrashekhar, A.P.;Anjali, S.;Dhar, Murali
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3645-3651
    • /
    • 2012
  • Conventional pap smear (CPS) examination has been the mainstay for early detection of cervical cancer. However, its widespread use has not been possible due to the inherent limitations, like presence of obscuring blood and inflammation, reducing its sensitivity considerably. Automated methods in use in developed countries may not be affordable in the developing countries due to paucity of resources. On the other hand, manual liquid based cytology (MLBC) is a technique that is cost effective and improves detection of precursor lesions and specimen adequacy. Therefore the aim of the study was to compare the utility of MLBC with that of CPS in cervical cancer screening. A prospective study of 100 cases through MLBC and CPS was conducted from October 2009 to July 2010, in a Medical College in India, by two independent pathologists and correlated with histopathology (22 cases). Morphological features as seen through MLBC and CPS were compared. Subsequently, all the cases were grouped based on cytological diagnosis according to two methods into 10 groups and a subjective comparison was made. In order to compare the validity of MLBC with CPS in case of major diagnoses, sensitivity and specificity of the two methods were estimated considering histological examination as the gold standard. Increased detection rate with MLBC was 150%. The concordance rate by LBC/histopathology v/s CPS/histopathology was also improved (86% vs 77%) The percentage agreement by the two methods was 68%. MLBC was more sensitive in diagnosis of LSIL and more specific in the diagnosis of inflammation. Thus, MLBC was found to be better than CPS in diagnosis of precursor lesions. It provided better morphology with increased detection of abnormalities and preservation of specimen for cell block and ancillary studies like immunocytochemistry and HPV detection. Therefore, it can be used as alternative strategy for cervical cancer prevention in limited resource settings.

Divalent Cation-dependent Inactivation of N-type Calcium Channel in Rat Sympathetic Neurons (쥐 교감신경 뉴론 N형 칼슘통로의 2가 양이온의존성 비활성화)

  • Goo Yong-Sook
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.96-104
    • /
    • 2006
  • Experiments from several groups Including ours have demonstrated that $Ca^{2+}$ can enhance the inactivation of N-type calcium channels. However, it is not clear if this effect can be ascribed to a 'classic' $Ca^{2+}$-dependent inactivation (CDI) mechanism. One method that has been used to demonstrate CDI of L-type calcium channels is to alter the intracellular and extracellular concentration of $Ca^{2+}$. In this paper we replaced the external divalent cation to monovalent ion ($MA^+$) to test CDI. In the previous paper, we could separate fast (${\tau}{\sim}150ms$) and slow (${\tau}{\sim}2,500ms$) components of inactivation in both $Ba^{2+}$ and $Ca^{2+}$ using 5-sec voltage step. Lowering the external divalent cation concentration to zero abolished fast inactivation with relatively little effect on slow inactivation. Slow inactivation ${\tau}$ correspond very well with provided the $MA^+$ data is shifted 10 mV hyperpolarized and slow inactivation ${\tau}$ decreases with depolarization voltage in both $MA^+\;and\;Ba^{2+}$, which consistent with a classical voltage dependent inactivation (VDI) mechanism. These results combined with those of our previous paper lead us to hypothesize that external divalent cations are required to produce fast N-channel inactivation and this divalent cation-dependent inactivation is a different mechanism from classic CDI or VDI.

  • PDF