• Title/Summary/Keyword: $m_v$ method

Search Result 2,710, Processing Time 0.034 seconds

Characteristics of a Planar Multijunction Thermal Converter (평면형 다중접합 열전변환기의 특성)

  • Jo, Hyeon-Deok;Kim, Jin-Seop;Lee, Jong-Hyeon;Lee, Jeong-Hui;Park, Se-Il;Gwon, Seong-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.10
    • /
    • pp.699-705
    • /
    • 2001
  • Six types of planar thermal converters from TC 1 to TC 6 were designed and fabricated for the purpose of being used as practical standards to alternating current. The respective voltage responses in air and in a vacuum of TC 6, which has the smallest thermal loss, were about 4.03mV/mW and about 6.38 mV/mW. Thermal time constant of TC 6, which has also the smallest heater thermal inertia, was about 8 ms. The respective variations of AC-DC voltage and current transfer errors from sample to sample, which were measured by FRDC(fast reversed DC) method, were about $\pm$0.41 ~$\pm$0.85 ppm and about $\pm$0.15~$\pm$1.16 ppm in the frequent range of 40 Hz~10 KHz with appling 1 V and 5 mA rms sine waves to the converters. All converters investigated exhibited sufficiently low AC-DC transfer errors to be used as practical standards.

  • PDF

The comparisons of three scatter correction methods using Monte Carlo simulation (몬테카를로 시뮬레이션을 이용한 산란보정 방법들에 대한 비교)

  • 봉정균;김희중;이종두;권수일
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.73-81
    • /
    • 1999
  • Scatter correction for single photon emission computed tomography (SPECT) plays an important role to improve image quality and quantitation. The purpose of this study was to investigate three scatter correction methods using Monte Carlo simulation. Point source and Jaszack phantom filled with Tc-99m were simulated by Monte Carlo code, SIMIND. For scatter correction, we applied three methods, Compton window (CW) method, triple window (TW) method, and dual photopeak window (DPW) method. Point sources located at various depths along the center line within a 20-cm phantom were simulated to calculate the window ratios and corresponding scatter fractions by evaluating the polynomial coefficients for DPW method. Energy windows were located in W$_1$=92-125 keV, W$_2$=124-126 keV, W$_3$=136-140 keV, W$_4$=140-141 keV, and W$_{5}$=154-156 keV. The results showed that in Jaszack phantom with cold sphere and hot sphere, the TW gave the closest contrast and percentage recovery to the ideal image, respectively, while CW overestimated and DPW underestimated the contrast of ideal one. All three scatter correction methods showed an improved image contrast. In conclusion, scatter correction is essential for improving image contrast and accurate quantification. The choice of scatter correction method should be made on the basis of accuracies and ease of implementation.

  • PDF

A Comparison of Dose in Changed Technique Factor Using X-ray Imaging System (X-선 장치의 기술적 인자의 변화에 따른 선량 비교 평가)

  • Han, Dong-Kyoon;Ko, Shin-Gwan;Seon, Jong-Ryul;Yoon, Seok-Hwan;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • With the recent development of diagnosis using radiation and increasing demand of the medical treatment, we need to minimize radiation exposure dose. So, This is the method which reduce patient dose by measuring surface dose of radiographic change factor and by comparing theoretical and actual dose, when we take an X-ray which is generally used. By changing the factor of kV, mAs, FSD, whose range is 60 to 120 kV, 20 to 100 mAs, 80 to 180 cm, we compared theoretical surface dose with actual surface dose calculated by the simple calculation program, Bit system, and NDD-M method As a result, when kV and mAs were higher, theoretical surface dose and actual surface dose were more increased. but the higher FSD was, the more decreased surface dose was. According to this, the error were measured about 0.1 to 0.2 mGy in low dose part and about 0.7 to 1.5 mGy in high dose part. Therefore, this shows that theoretical surface dose calculation method is more correct in low dose part than in high dose part. In conclusion, we will have to make constant efforts which can reduce patient and radiographer's exposure dose, studying methods which can predict patient's radiation exposure dose more exactly.

  • PDF

Production of Monoclonal Antibodies against Vibrio parahaemolyticus and Development of High Sensitive Immuno-Selective Filtration Method (Vibrio parahaemolyticus에 대한 단클론성 항체 개발과 고감도 면역선택여과법의 개발)

  • Kim, Jeong-Sook;Choi, Young-Dong;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.1
    • /
    • pp.21-27
    • /
    • 2016
  • The objectives of this study are to produce monoclonal antibodies (MAbs) against Vibrio parahaemolyticus and to develop an immuno-selective filtration (ISF) method for the rapid and sensitive detection of V. parahaemolyticus. The characterization of the MAb produced from HKVP 4H9-9 hybridoma cell was validated by enzyme-linked immunosorbent assay (ELISA) and western blot. The produced MAb was specific to V. parahaemolyticus and showed weak cross-reaction to V. alginolyticus, V. vulnificus and Staphylococcus aureus. After optimization of the method, $5{\times}10^1cell/mL$ of V. parahaemolyticus in a pure culture could be detectable. Although weak cross-reactivity to V. vulnificus, V. alginolyticus and Staphylococcus aureus was observed, the ISF was confirmed to be highly specific to V. parahaemolyticus. Especially, the ISF showed the most sensitivity compared to the immunoassays currently reported is easier to perform and quicker than ID-ELISA.

Flatness Characteristics Analysis Technique of Attenuator Using Thermal Voltage Converter and AC Measurement Standard (열전압변환기와 교류측정표준을 사용한 감쇠기 평탄도 특성 분석 기법)

  • Cha, Yun-bae;Kim, Boo-il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.330-337
    • /
    • 2018
  • This paper proposes a technique to analyze the flatness characteristics of the attenuator at 10Hz to $50\text\tiny{MHz}$ on the basis of $1\text\tiny{kHz}$ using a Thermal Voltage Converter and AC measurement standard. In the proposed technique, the input voltage of the attenuator for each measuring frequency is supplied at the same rate as $1\text\tiny{kHz}$ using TVC, and the flatness characteristics of the attenuator are analyzed by the voltage variation indicated in the AC measurement standard. The results of the analysis of the attenuator flatness characteristics show that the maximum uncertainty of $866{\mu}V/V$ can be measured from $10\text\tiny{dB}$ to $70\text\tiny{dB}$ and the uncertainty is reduced by about 37% compared to $2.31\text\tiny{mV}$/V using the network measurement method. The improved attenuator flatness characteristic values can be applied to the frequency flatness calibration from 2.2V to 2.2mV at the low voltage of the AC measurement standard.

A Simple and Sensitive High Performance Liquid Chromatography-Electrospray Ionization/Mass Spectrometry Method for the Quantification of Ethyl Pyruvate in Rat Plasma

  • Kim, Hyun-Ji;Kim, Seung-Woo;Lee, Ja-Kyeong;Yoon, Sung-Hwa
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1221-1227
    • /
    • 2011
  • Ethyl pyruvate (EP) is known as a scavenger of reactive oxygen species (ROS) in the body through its role in the donation of diketone groups to metals to form an EP-metal complex. In order to develop a method for the quantification of EP in biological media, a sensitive and specific, high-performance liquid chromatographyelectrospray ionization-mass spectrometry (HPLC-ESI/MS) method is used to determine the EP-alkali metal ion binding species. The analyte was separated on a ZORBOX SB-C8 ($3.5{\mu}m$, $30mm{\times}2.1mm$ I.D.) column and analyzed in selected ion monitoring (SIM) mode with a positive ESI interface using the m/z 255 $[2M + Na]^+$ ion. The method was validated over the concentration range of $0.5-60.0\;{\mu}g$/mL under 1/9 (v/v) of acetonitrile/methanol solvent system with flow rate 0.05 mL/min. The limit of quantification (LOQ) was $0.5{\mu}g$/mL.

Clinical Experiences about Correction of Web Space Contracture and Syndactyly using V-M Plasty (V-M 성형술을 이용한 지간구축 및 합지증의 교정 임상례)

  • Kim, Eui-Sik;Park, Sang-Ryul;Hwang, Jae-Ha;Kim, Kwang-Seog;Lee, Sam-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.46-51
    • /
    • 2010
  • Purpose: The loss of web space is caused by congenital syndactyly or acquired burn injury, trauma or surgery. Numerous surgical procedures have been described for restoration of the web space. Local flaps are usually preferred because of the easiness to perform and tolerable postoperative outcome. Among the various local flaps, the authors introduce V-M plasty for correction of web space contracture and syndactyly. Method: From March 2007 to Jun 2008, 4 patients underwent V-M plasty for correction of web space contracture and syndactyly. V-M plasty consists of 3 distinct triangular flaps. One triangular flap is designed next to the web region on the dorsal site of the hand, whereas the remaining 2 triangular flaps are placed on the volar site. The dorsal triangular flap is then placed between the volar adjacent triangular flaps. At the end of the operation, the involved fingers or toes are positioned in abduction to avoid kinking of the triangular flaps. Result: All the patients gained web functions with good esthetic appearance without any recurrence or complications. Mean follow-up was 8 months. Conclusion: V-M plasty is a safe, easy and rapid procedure to design and apply by using local tissues without the needs for a skin graft or risk of linear scarring and recurrence. The authors advise this versatile technique both in primary and recurrent cases of web space contracture and syndactyly.

Simple and Quantitative Analysis Method for Lactic Acid by TLC (젖산의 빠른 정량적 분석을 위한 TLC 최적 조건)

  • 최미화;조갑수;강희경;윤종선;서은성;류화원;장세효;윤승헌;김도만
    • KSBB Journal
    • /
    • v.18 no.1
    • /
    • pp.70-73
    • /
    • 2003
  • TLC condition was developed for its simple separation and quantitative analysis of lactic acid. Rapid and clear separation of lactic acid by silica gel TLC plate was obtained by using nitromethane : 1-propanol : $H_2O$ (2 : 5 : 1.5, v/v/v) and a suitable dipping solution of 40 mg bromocresol purple in 100 mL 5% ethanol (pH 10.0). The lactic acid was shown as a bright yellow spot on a light cinnabar background. The quantitatively detectable concentration range of lactic acid was between 0.5 and 4% with 99.4%, confidence. Quantitative TLC analysis result was confirmed with HPLC and with enzymatic Quantitative analysis methods (by using lactate dehydrogenase).

Site Characterization using Shear-Wave Velocities Inverted from Rayleigh-Wave Dispersion in Chuncheon, Korea (레일리파 분산을 역산하여 구한 횡파속도를 이용한 춘천시의 부지특성)

  • Jung, JinHoon;Kim, Ki Young
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • To reveal and classify site characteristics in densely populated areas in Chuncheon, Korea, Rayleigh-waves were recorded at 50 sites including four sites in the forest area using four 1-Hz velocity sensors and 24 4.5-Hz vertical geophones during the period of January 2011 to May 2013. Dispersion curves of the Rayleigh waves obtained by the extended spatial autocorrelation method were inverted to derive shear-wave velocity ($v_s$) models comprising 40 horizontal layers of 1-m thickness. Depths to weathered rocks ($D_b$), shear wave velocities of these basement rocks ($v_s^b$), average velocities of the overburden layer ($\bar{v}_s^s$), and the average velocity to a depth of 30 m ($v_s30$), were then derived from those models. The estimated values of $D_b$, $v_s^b$, $\bar{v}_s^s$, and $v_s30$ for 46 sites at lower altitudes were in the ranges of 5 to 29 m, 404 to 561 m/s, 208 to 375 ms/s, and 226 to 583 m/s, respectively. According to the Korean building code for seismic design, the estimated $v_s30$ indicates that the lower altitude areas in Chuncheon are classified as $S_C$ (very dense soil and soft rock) or $S_D$ (stiff soil). To determine adequate proxies for $v_s30$, we compared the computed values with land cover, lithology, topographic slope, and surface elevation at each of the measurement sites. Due to a weak correlation (r = 0.41) between $v_s30$ and elevation, the best proxy of them, applications of this proxy to Chuncheon of a relatively small area seem to be limited.

Finite Element Method Analysis for Temperature Profile of a Planar Multijunction Thermal Converter (유한 요소법에 의한 평면형 다중접합 열전변환기의 온도분포 해석)

  • Hwang, Chan-Soon;Cho, Hyun-Duk;Kwon, Jae-Woo;Lee, Jung-Hee;Lee, Jong-Hyun;Kim, Jin-Sup;Park, Se-Il;Kwon, Sung-Won
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.196-206
    • /
    • 2001
  • Real temperature profiles of a planar chromel-alumel mutli-junction thermal converter(TC 1) were measured by thermal image. Temperature profiles as a function of input power of thermal converters(TC 1${\sim}$TC 6) were simulated by 3-dimensional ANSYS program based on finite element method. Temperature difference between the hot junction and the cold junction for TC 1 was smallest and largest for TC 6 and correspondingly, he voltage response for TC 1 and TC 6 showed the smallest value of 3.09 mV/mW and the largest value of 4.03 mV/mW, respectively.

  • PDF