Characteristics of a Planar Multijunction Thermal Converter

평면형 다중접합 열전변환기의 특성

  • 조현덕 (삼성전자주식회사 반도체연구소) ;
  • 김진섭 (인제대학교 전자정보통신공학부) ;
  • 이종현 (경북대학교 전자전기컴퓨터학부) ;
  • 이정희 (경북대학교 전자전기컴퓨터학부) ;
  • 박세일 (한국표준과학연구원 전자기표준부) ;
  • 권성원 (한국표준과학연구원 전자기표준부)
  • Published : 2001.10.01

Abstract

Six types of planar thermal converters from TC 1 to TC 6 were designed and fabricated for the purpose of being used as practical standards to alternating current. The respective voltage responses in air and in a vacuum of TC 6, which has the smallest thermal loss, were about 4.03mV/mW and about 6.38 mV/mW. Thermal time constant of TC 6, which has also the smallest heater thermal inertia, was about 8 ms. The respective variations of AC-DC voltage and current transfer errors from sample to sample, which were measured by FRDC(fast reversed DC) method, were about $\pm$0.41 ~$\pm$0.85 ppm and about $\pm$0.15~$\pm$1.16 ppm in the frequent range of 40 Hz~10 KHz with appling 1 V and 5 mA rms sine waves to the converters. All converters investigated exhibited sufficiently low AC-DC transfer errors to be used as practical standards.

교류의 실용 표준기로 사용하기 위해 TC 1에서 TC 6까지 6개의 평면형 열전변환기를 설계 및 제작하였다. 공기중 및 진공중의 전압 감응도는 TC 6의 경우 열손실이 가장 작아 약 4.03 mV/mW 및 약 6.38 mV/mW의 가장 큰 값을 나타내었다. 열시정수는 히터의 열관성이 가장 부족한 TC 6을 측정하여 약 8 ms를 얻었다. FRDC(fast reversed DC) 방법에 의한 교류-직류 전압 및 전류 변환오차는 40 Hz∼10 ㎑ 주파수 범위에서 1 V 및 5 mA의 정현파 실효전압 및 실효전류를 인가하였을 때 약 ±0.41∼±0.85 ppm 및 약 ±0.15∼±1.16 ppm으로서 실용표준으로 사용하기에 적합하였다.

Keywords

References

  1. F. J. Wilkins et al., 'Multi-junction thermal converter-accurate d.c./a.c. transfer instrument,' Proc. of the IEE, Vol. 112, No. 4, pp. 794-805, 1965
  2. Barry D. Inglis, 'A method for the determination of ac-dc transfer errors in thermoelements,' IEEE Trans. on Instrumentation and Measurement, Vol. IM-27, No. 4, pp. 440-444, 1978
  3. Manfred Klonz, 'AC-DC transfer difference of the PTB multijunction the rmal converter in the frequency range from 10 Hz to 100 KHz,' IEEE Trans. on Instrumentation and Measurement, Vol. IM-36, No. 2, pp. 320-329, 1987
  4. Manfred Klonz and Thomas Weimann, 'Accurate thin-film multijunction thermal converter on a silicon chip,' IEEE Trans. on Instrumentation and Measurement, Vol. 38, No. 2, pp. 335-337, 1989 https://doi.org/10.1109/19.192301
  5. 김명규 등, '스트레스 균형이 이루어진 $Si_3N_4/SiO_2/Si_3N_4$ 유전체 멤브레인의 제작,' 센서학회지, 제4권, 제3호, pp. 51-59, 1995
  6. 정인식 등, '박막형 크로멜-알루멜 다중접합 열전 변환기,' 전자공학회논문지, 제36권, D편, 제9호, pp. 37-45, 1999
  7. 조현덕 등, '저출력저항의 박막 크로멜-알루멜 다중접합 열전변환기,' 센서학회지, 제9권, 제4호, pp. 288-295, 2000
  8. Manfred Klonz and Thomas Weimann, 'Increasing the time constant of a thin film multijunction thermal converter for low frequency application,' IEEE Trans. on Instrumentation and Measurement, Vol. 40, No. 2, pp. 350-351, 1991 https://doi.org/10.1109/TIM.1990.1032957
  9. Manfred Klonz et al., 'Measuring themoelectric effects in thermal converters with a fast reversed DC,' IEEE Trans. on Instrumentation and Measurement. Vol. 44, No. 2, pp. 379-382, 1995 https://doi.org/10.1109/19.377858
  10. 권성원 등, '교류-직류 변환오차 자동 측정시스템,' 센서학회지, 제7권, 제6호, pp. 401-408, 1998
  11. B.D. Inglis, 'Standards for AC-DC transfer,' Metrologia, Vol. 29, pp. 191-199, 1992 https://doi.org/10.1088/0026-1394/29/2/007
  12. Metrologia v.29 Standards for AC-DC transfer B.D.Inglis