• Title/Summary/Keyword: $L^1$-convergence

Search Result 660, Processing Time 0.024 seconds

Synthesis of Highly Dispersed and Conductive Graphene Sheets by Exfoliation of Preheated Graphite in a Sealed Bath and its Applications to Polyimide Nanocomposites

  • Hossain, Muhammad Mohsin;Hahn, Jae Ryang;Ku, Bon-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.7
    • /
    • pp.2049-2056
    • /
    • 2014
  • A simple method for exfoliating pristine graphite to yield mono-, bi-, and multi-layers of graphene sheets as a highly concentrated (5.25 mg/mL) and yielded solution in an organic solvent was developed. Pre-thermal treatment of pristine graphite at $900^{\circ}C$ in a sealed stainless steel bath under high pressures, followed by sonication in 1-methyl-2-pyrrolidinone solvent at elevated temperatures, produced a homogeneous, well-dispersed, and non-oxidized graphene solution with a low defect density. The electrical conductivities of the graphene sheets were very high, up to 848 S/cm. These graphene sheets were used to fabricate graphene-polyimide nanocomposites, which displayed a higher electrical conductivity (1.37 S/m) with an improved tensile strength (95 MPa). The synthesized graphene sheets and nanocomposites were characterized by transmission electron microscopy, scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, and Raman spectroscopy.

Preparation of activated carbon incorporated polysulfone membranes for dye separation

  • Ingole, Pravin G.;Sawant, Sandesh Y.;Ingole, Neha P.;Pawar, Radheshyam R.;Bajaj, Hari C.;Singh, Kripal;Cho, Moo Hwan;Lee, Hyung Keun
    • Membrane and Water Treatment
    • /
    • v.7 no.6
    • /
    • pp.477-493
    • /
    • 2016
  • Immediate use of activated carbon incorporated polysulfone membrane application for dye separation was reported in this work. Dimethylformamide (DMF) was used as the solvent for the membrane preparation. The membrane thus prepared were characterized in terms of surface morphology, ATR-FTIR, AFM, experimental results as membrane performance. The resultant nanofiltration (NF) membranes were tested with Congo red dye concentration 200 mg/L. The water permeability was found to be considerably higher than that reported in literature. Experimental results show that the real rejection of the Congo red is 99.57% over the transmembrane pressure 100 psi using 30% activated carbon incorporated membrane. Prepared NF membranes shows the corresponding permeates fluxes were $40Lm^{-2}h^{-1}$ to $82Lm^{-2}h^{-1}$ with different activated carbon percentage incorporated in polysulfone membrane. The present study demonstrated that dye rejection enhanced NF may be a feasible method for the dye wastewater treatment. The overall observations thus indicated that toxic residual dyes can be appreciably separated from the membrane technology, provided that the accompanying polymeric membrane, activated carbon as binding agents and the process parameter levels are astutely selected.

Distribution and Molecular Characteristics of Vibrio vulnificus Isolated from Seawater Along the Gadeok Island Coast (가덕도 연안 해수에서 Vibrio vulnificus의 분포 및 분리균주의 병원성 유전자 특성)

  • Oh, Hee-Kyung;Jeong, Hee-Jin;Kim, Young-Mog
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.5
    • /
    • pp.688-693
    • /
    • 2020
  • Vibrio vulnificus is a Gram-negative marine bacterium known to cause septicemia. This study was conducted to investigate the distribution of V. vulnificus along the coast of Gadeok Island in Korea and to determine the molecular characteristics of isolated strains sampled between March and November 2019 from seawater. The strains were mostly detected between July and September, when the average water temperature and average salinity were 22.2-26.2℃ and 14.2-29.9 psu, respectively. V. vulnificus was not detected in seawater below 15℃. In September, the highest population of V. vulnificus was observed at 2,100 MPN (most probable number)/100 mL, attributable to decreased salinity from heavy rains. In addition, the detection rate of V. vulnificus was higher at the sampling station near the Nakdong River. Virulence-related genes were also identified among the isolates, such as vvhA (97.1%), viuB (44.1%), and vcgC (57.4%). In particular, viuB and vcgC were only observed in V. vulnificus isolated from June to September, when the detection rate was high and water temperature was above 20℃, suggesting the role of seasonal characteristics.

Color Evaluation of Commercial Domestic Hardwoods (I)

  • Park, Byung-Ho;Kim, Nam-Hun
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.3
    • /
    • pp.199-207
    • /
    • 2011
  • Examined the color of ten species of Korean broadleaf trees were experimented based on $L^*a^*b^*$ values and color difference (${\Delta}E^*ab$) between sapwood and heartwood, in order to analyze and determine the color, a critical visual and decorative factor of the broadleaf trees that can be used for making woodcraft and furniture. According to the result, the entire sapwood and heartwood, except the heartwood of Populus tomentiglandulosa, showed positive value in whiteness, redness, and yellowness and therefore contained yellow and red. None of the species showed color difference between sapwood and heartwood that was trace (0~0.5), slight (0.6~1.5), or very much; whereas Populus maximowiczii showed noticeable color difference (1.5~3.0); Salix koreensis, Betula platyphylla var japonica, Carpinus laxiflora, and Castanea crenata, appreciable and Populus tomentiglandulosa, Juglans mandshurica, Betula schmidtii, Alnus japonica, and Quercus variabilis, much. The color characteristics of heartwood and sapwood of the ten Korean broadleaf tree species studied in this research can be used as basic data for woodcraft or furniture production, especially when replacing foreign woods with Korean ones, and also contribute to convergence researches for science, engineering, and design fields.

  • PDF

Analysis on the Effect of Spectral Index Images on Improvement of Classification Accuracy of Landsat-8 OLI Image

  • Magpantay, Abraham T.;Adao, Rossana T.;Bombasi, Joferson L.;Lagman, Ace C.;Malasaga, Elisa V.;Ye, Chul-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.4
    • /
    • pp.561-571
    • /
    • 2019
  • In this paper, we analyze the effect of the representative spectral indices, normalized difference vegetation index (NDVI), normalized difference water index (NDWI) and normalized difference built-up index (NDBI) on classification accuracies of Landsat-8 OLI image.After creating these spectral index images, we propose five methods to select the spectral index images as classification features together with Landsat-8 OLI bands from 1 to 7. From the experiments we observed that when the spectral index image of NDVI or NDWI is used as one of the classification features together with the Landsat-8 OLI bands from 1 to 7, we can obtain higher overall accuracy and kappa coefficient than the method using only Landsat-8 OLI 7 bands. In contrast, the classification method, which selected only NDBI as classification feature together with Landsat-8 OLI 7 bands did not show the improvement in classification accuracies.

Portable Soil pH Sensor Using ISFET Electrode

  • Hong, Youngsin;Chung, Sun-Ok;Park, Jongwon;Hong, Youngki
    • Journal of information and communication convergence engineering
    • /
    • v.20 no.1
    • /
    • pp.49-57
    • /
    • 2022
  • Fertilizers have long been used to increase crop yields; however, farmers are still having difficulties in managing fertilizers for growing crops as well as economic problems. The conventional method of soil sampling and laboratory analysis to determine soil pH is time consuming and costly; therefore, a portable pH sensor is developed to characterize spatial or temporal variability within fields via rapid and dense data acquisition. The portable pH sensor comprises an electrode unit, a portable console, and a USB connector. The soil water content (SWC) and electrical conductivity (EC) affect the electrical resistance of soil. An artificial test soil is performed to evaluate the effect of SWC and EC on soil pH. The test results show that stable pH measurements are achieved at SWCs greater than 20 mL (16.3%). Regardless of the SWC, the electric potential difference (EPD) remains at 2.5 g of NaCl. As the EC increases in the soil samples, the EPD increases.

Numerical investigation of water-entry characteristics of high-speed parallel projectiles

  • Lu, Lin;Wang, Chen;Li, Qiang;Sahoo, Prasanta K.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.450-465
    • /
    • 2021
  • In this study, an attempt has been made to investigate the water-entry characteristics of the high-speed parallel projectile numerically. The shear stress transport k-𝜔 turbulence model and the Zwart-Gerber-Belamri cavitation model based on the Reynolds-Averaged Navier-Stokes method were used. The grid independent inspection and grid convergence index is carried out and verified. The influences of the parallel water-entry on flow filed characteristics, trajectory stability and drag reduction performance for different values of initial water-entry speed (𝜈0 = 280 m/s, 340 m/s, 400 m/s) and clearance between the parallel projectiles (Lp = 0.5D, 1.0D, 2.0D, 3.0D) are presented and analyzed in detail. Under the condition of the parallel water-entry, it can be found that due to the intense interference between the parallel projectiles, the distribution of cavity is non-uniform and part of the projectile is exposed to water, resulting in the destruction of the cavity structure and the decline of trajectory stability. In addition, the parallel projectile suffers more severe lateral force that separates the two projectiles. The drag reduction performance is impacted and the velocity attenuation is accelerated as the clearance between the parallel projectiles reduces.

Application of Montmorillonite as Capping Material for Blocking of Phosphate Release from Contaminated Marine Sediment (해양오염퇴적물 내 인산염 용출차단을 위한 피복소재로서의 몬모릴로나이트 적용)

  • Kang, Ku;Kim, Young-Kee;Hong, Seong-Gu;Kim, Han-Joong;Park, Seong-Jik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.554-560
    • /
    • 2014
  • To investigate the applicability of montmorillonite to capping material for the remediation of contaminated marine sediment, adsorption characteristics of $PO{_4}{^{3-}}$ onto montmorillonite were studied in a batch system with respect to changes in contact time, initial concentration, pH, adsorbent dose amount, competing anions, adsorbent mixture, and seawater. Sorption equilibrium reached in 1 h at 50 mg/L but 3 h was required to reach sorption equilibrium at 300 mg/L. Freundlich model was more suitable to describe equilibrium sorption data than Langmuir model. The $PO{_4}{^{3-}}$ adsorption decreased as pH increased, due to the $PO{_4}{^{3-}}$ competition for favorable adsorption site with OH- at higher pH. The presence of anions such as nitrate, sulfate, and bicarbonate had no significant effect on the $PO{_4}{^{3-}}$ adsorption onto the montmorillonite. The use of the montmorillonite alone was more effective for the removal of the $PO{_4}{^{3-}}$ than mixing the montmorillonite with red mud and steel slag. The $PO{_4}{^{3-}}$ adsorption capacity of the montmorillonite was higher in seawater than deionized water, resulting from the presence of calcium ion in seawater. The water tank elution experiments showed that montmorillonite capping blocked well the elution of $PO{_4}{^{3-}}$, which was not measured up to 14 days. It was concluded that the montmirillonite has a potential capping material for the removal of the $PO{_4}{^{3-}}$ from the aqueous solutions.

Comparison of breast volume change between oncoplastic breast-conserving surgery with radiation therapy and a simultaneous contralateral balancing procedure through the inverted-T scar technique

  • Kim, Min Wook;Oh, Won Seok;Lee, Jae Woo;Kim, Hyun Yul;Jung, Youn Joo;Choo, Ki Seok;Nam, Kyung Jin;Bae, Seong Hwan;Kim, Choongrak;Nam, Su Bong;Joo, Ji Hyeon
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.583-589
    • /
    • 2020
  • Background Reduction mammoplasty or mastopexy is performed as an additional balancing procedure in patients with large or ptotic breasts who undergo breast-conserving surgery (BCS). Radiation therapy on breasts that have undergone surgery may result in changes in the volume. This study presents a comparative analysis of patients who received post-BCS balancing procedures to determine whether volume changes were larger in breasts that received radiation therapy than on the contralateral side. Methods Thirty-six participants were selected among patients who received BCS using the inverted-T scar technique between September 2012 and July 2017, were followed up for 2 or more years, and had pre-radiation therapy computed tomography images and post-radiation therapy images taken between 12 and 18 months after completion. The average age of the participants was 53.5 years, their average body mass index was 26.62 kg/㎡. Results The pre- and post-radiation therapy volumes of the breasts receiving BCS were 666.08±147.48 mL and 649.33±130.35 mL, respectively. In the contralateral breasts, the volume before radiation therapy was 637.69±145.72 mL, which decreased to 628.14±166.41 mL after therapy. The volume ratio of the affected to the contralateral breasts was 1.05±0.10 before radiation therapy and 1.06±0.12 after radiation therapy. Conclusions The ratio of the volume between the two breasts immediately after surgery and at roughly 18 months postoperatively was not significantly different (P=0.98). For these reasons, we recommend a simultaneous single-stage balancing procedure as a reasonable option for patients who require radiation therapy after BCS without concerns regarding volume change.

Influence of Acid and Heat Treatment on the Removal of Fluoride by Red Mud (Red Mud의 산처리 및 열처리가 불소 제거에 미치는 영향)

  • Kang, Ku;Nyakunga, Expedito;Kim, Young-Kee;Park, Seong-Jik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.210-217
    • /
    • 2015
  • Fluoride removal by acid and heat treated red mud were studied in batch and column system regarding contact time, initial concentration, pH, adsorbent dose, and filter depth. The results showed that acid treated with 0.8 M HCl, had highest adsorption capacity of fluoride and adsorption capacity decreased as heat treatment temperature increased. Sorption equilibrium reached in 30 min at a initial concentration of 50 mg-F/L but 1 h was required to reach the sorption equilibrium at the initial concentration of 500 mg-F/L by 0.8 M acid treated red mud (0.8 M-ATRM). Equilibrium adsorption data were fitted well to Langmuir isotherm model with maximum fluoride adsorption capacity of 23.162 mg/g. The fluoride adsorption decreased as pH increased due to the fluoride competition for favorable adsorption site with $OH^-$ at higher pH. Removal percentage was increased but the amount of adsorption per unit mass decreased by adding the amount of 0.8 M-ATRM. It was concluded that the 0.8 M-ATRM could be used as a potential adsorbent for the fluoride removal from aqueous solutions because of its high fluoride adsorption capacity and low cost.