• Title/Summary/Keyword: $J_0$ Component

Search Result 210, Processing Time 0.032 seconds

THE 3D BOUSSINESQ EQUATIONS WITH REGULARITY IN THE HORIZONTAL COMPONENT OF THE VELOCITY

  • Liu, Qiao
    • Bulletin of the Korean Mathematical Society
    • /
    • v.57 no.3
    • /
    • pp.649-660
    • /
    • 2020
  • This paper proves a new regularity criterion for solutions to the Cauchy problem of the 3D Boussinesq equations via one directional derivative of the horizontal component of the velocity field (i.e., (∂iu1; ∂ju2; 0) where i, j ∈ {1, 2, 3}) in the framework of the anisotropic Lebesgue spaces. More precisely, for 0 < T < ∞, if $$\large{\normalsize\displaystyle\smashmargin{2}{\int\nolimits_o}^T}({\HUGE\left\|{\small{\parallel}{\partial}_iu_1(t){\parallel}_{L^{\alpha}_{x_i}}}\right\|}{\small^{\gamma}_{L^{\beta}_{x_{\hat{i}}x_{\bar{i}}}}+}{\HUGE\left\|{\small{\parallel}{\partial}_iu_2(t){\parallel}_{L^{\alpha}_{x_j}}}\right\|}{\small^{\gamma}_{L^{\beta}_{x_{\hat{i}}x_{\bar{i}}}}})dt<{{\infty}},$$ where ${\frac{2}{{\gamma}}}+{\frac{1}{{\alpha}}}+{\frac{2}{{\beta}}}=m{\in}[1,{\frac{3}{2}})$ and ${\frac{3}{m}}{\leq}{\alpha}{\leq}{\beta}<{\frac{1}{m-1}}$, then the corresponding solution (u, θ) to the 3D Boussinesq equations is regular on [0, T]. Here, (i, ${\hat{i}}$, ${\tilde{i}}$) and (j, ${\hat{j}}$, ${\tilde{j}}$) belong to the permutation group on the set 𝕊3 := {1, 2, 3}. This result reveals that the horizontal component of the velocity field plays a dominant role in regularity theory of the Boussinesq equations.

A Small group of protostellar objects: L1251C

  • Kim, Jungha;Lee, Jeong-Eun;Choi, Minho
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.66.1-66.1
    • /
    • 2013
  • We present various observational results toward a small group of Young Stellar Objects (YSOs), L1251C. Observations by Spitzer Space Telescope legacy program "From Molecular Cores to Planet Forming Disks" (c2d; Evans et al. 2003) revealed that there are three YSOs within ~15" in L1251C: IRS1 (Class I), IRS2 (Class II), and IRS3 (Class II). In order to understand the molecular environment around these YSOs, we carried out the KVN single-dish observations in $HCO^+$ J=1-0, $H^{13}CO^+$ J=1-0, $N_2H^+$ J=1-0 and HCN J=1-0. $^{12}CO$ J=1-0 was also mapped in L1251C with the TRAO 14m telescope. Integrated intensity maps of high density tracers such as $H^{13}CO^+$ J=1-0, $N_2H^+$ J=1-0 and HCN J=1-0 show similar emission distributions, whose peaks are off the positions of YSOs. A compact $HCO^+$ J=1-0 outflow and an extended $^{12}CO$ J=1-0 outflow were observed, but their outflow axes are not cosistent ($HCO^+$: NW-SE, $^{12}CO$: EW). However, the highest velocity component of the $^{12}CO$ J=1-0 outflow shows similar morphology to the $HCO^+$ J=1-0 outflow, and ~ 23 % of $^{12}CO$ outflow momentum flux is loaded onto this high velocity component. Furthermore, continuum emission has been observed at 350, 450, 850 ${\mu}m$, and 1.3mm. With the KVN single dish, the 22 GHz $H_2O$ maser emission has been also monitored toward L1251C to find variations of the systemic velocity and intensity with time.

  • PDF

Repeatability Assessment of Autorefractor and Accuracy Analysis of Refraction Measurements by Fourier Analysis (자동굴절검사기의 신뢰성 평가 및 Fourier analysis에 의한 정확도 분석)

  • Kim, Tae-Hun;Ye, Ki-Hun;Kim, Jae-Kwang;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.29-36
    • /
    • 2008
  • Purpose: We have evaluated both the reliability and accuracy of refractive measurement from autorefractor by comparing with subjective refraction data. Methods: Measurements of refractive error were performed on 198 eyes of 99 subjects in noncycloplegic condition. Also we analyzed refraction results and evaluated repeatability and accuracy of subjective refraction and autorefraction. Furthermore we analyzed accuracy of autorefractor by Fourier analysis. Results: Reliability coefficient of the autorefraction for the right eye were determined to by 0.993, 0.974 and 0.925 respectively, in the spherical, cylinderical component and cylinderical Axis. Also, the reliability coefficient of the autorefraction for the left eye were found to be 0.991, 0.948 and 0.886, respectively, in the spherical, cylinderical component and cylinderical Axis. From the Fourier analysis no statistically significant differences in $J_{0}$ component were found between the auto and subjective refraction measurements (p>0.05) whereas difference of refractive power of $J_{45}$ component when compared with the subjective refraction were -0.019, -0.164. Conclusions: We conclude that autorefractormeter can be effectively used to measure the refractive power within the error limits.

  • PDF

Circardian rhythm of cardiac nonlinear dynamics in healthy human

  • Yum, M.K.;Kim, N.S.;Oh, J.W.;Kim, C.R.;Lee, J.H.;Kim, S.K.;Lee, J.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.323-326
    • /
    • 1997
  • In this study, we investigated the circardian rhythm of complexity of cardiac dynamics in humans. Dynamic 24-hour electrocardiographic recordings were obtained from 30 healthy ambulant subjects aged 41 to 50 years. or each recordings, normalized low frequency (0.04-0.1 hertz) and high frequency (>0.15 hertz) component are calculated. our different indexes obtained from separate algorithms of nonlinear dynamics - approximate entropy, correlation dimension, Lyapunov exponent and fractal dimension - were calculated. During early morning, low frequency component rose rapidly with concomitant withdrawl of high frequency component. All the our indexes of nonlinear dynamics showed remarkably same circardian rhythm: an early morning dip preceded by a steep decline during late night, a gradual recovery during evening and a peak around midnight. These data indicate that the simultansous losses of all of the our different mechanisms of nonlinear control of heart rate during early morning, concomitent with the surge of symapathetic activity and reduction of vagal activity, may contribute to the increased incidence of cardiovascular events during morning hours.

  • PDF

Sensing method of multi-component forces and moments using a column structure (기둥을 이용한 다축 힘/모멘트 감지 방법에 관한 연구)

  • Shin, H.H.;Kang, D.I.;Park, Y.K.;Kim, J.H.;Joo, J.W.;Kim, O.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.837-841
    • /
    • 2001
  • The column-type sensing element in building and mechanical construction parts was designed as three forces and three moments sensor by attaching strain gages approximately. Compared to conventional multi-component sensor, the designed sensor can solve the problem about low stiffness and high cost. The radius of the column was designed analytically and compared with finite element analysis. The coupling errors between components were minimized by using addition and subtraction procedure of signals. The fabricated sensor was tested by using a deadweight force standard machine and a six-component force calibration machine in Korea Research Institute of Standards and Science(KRISS). The calibration showed that the multi-component force/moment sensor had coupling error less than 19.8 % between $F_x$ and $M_y$ components, and 9.0 % in case of other components.

  • PDF

ON THE STRUCTURE OF GRADED LIE TRIPLE SYSTEMS

  • Martin, Antonio Jesus Calderon
    • Bulletin of the Korean Mathematical Society
    • /
    • v.53 no.1
    • /
    • pp.163-180
    • /
    • 2016
  • We study the structure of an arbitrary graded Lie triple system $\mathfrak{T}$ with restrictions neither on the dimension nor the base field. We show that $\mathfrak{T}$ is of the form $\mathfrak{T}=U+\sum_{j}I_j$ with U a linear subspace of the 1-homogeneous component $\mathfrak{T}_1$ and any $I_j$ a well described graded ideal of $\mathfrak{T}$, satisfying $[I_j,\mathfrak{T},I_k]=0$ if $j{\neq}k$. Under mild conditions, the simplicity of $\mathfrak{T}$ is characterized and it is shown that an arbitrary graded Lie triple system $\mathfrak{T}$ is the direct sum of the family of its minimal graded ideals, each one being a simple graded Lie triple system.

Clinical Study on Measurement Accuracy of Astigmatic Components (난시성분의 측정 정확도에 관한 임상적 연구)

  • Yoo, Jong-Sook;Sung, A-Young;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • Clinical evaluation by Astigmatic Components of autorefractors was performed to examine validity and accuracy compared with subjective refraction. The mean cylindrical powers of Astigmatic Components of Subjective Refraction, Closed-view and Open-view were found to be $-0.689{\pm}0.516D$, $-0.691{\pm}0.530D$, $-0.470{\pm}0.507D$, respectively. The Difference of cylindrical Components between Subjective Refraction and Closed, Open-view were found to be $0.002{\pm}0.191D$, $0.015{\pm}0.137D$, respectively. Approximately 85% of Closed-view and Open-view autorefractor measurements were within ${\pm}20^{\circ}$ range of the difference of cylindrical axis with subjective refraction. The mean $J_0$ Components of Astigmatic Components of subjective refraction, Closed-view and Open-view were found to be $-0.155{\pm}0.332D$, $-0.004{\pm}0.178D$, $-0.001{\pm}0.156D$, respectively. The mean $J_{45}$ Components of Astigmatic Components, Closed-view and Open-view were found to be $-0.023{\pm}0.227D$, $-0.026{\pm}0.172D$, $-0.014{\pm}0.182D$, respectively. Both of the Closed-view and Open-view refractor showed available accuracy in measuring astigmatic components.

  • PDF

Fabrication of Nano-sized Titanate Powders by an Ethylene Glycol Solution Route

  • Lee, S.J.;Lee, M.J.;Yoon, Y.S.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.440-441
    • /
    • 2006
  • Several titanate powders ($Al_2TiO_5,\;SrTiO_3$, etc.) were synthesized by an ethylene glycol solution route. Titanium isopropoxide and nitrate salts were dissolved in stoichiometric proportions in liquid-type ethylene glycol without any precipitation. The parent precursor sols were dried to porous gels, and then the gels were calcined and crystallized. All synthesized titanate powders had stable crystallization behavior at low temperature and high specific surface area after a simple ball-milling process. A three-component PZT $(Pb(Zr_{0.52}{\cdot}Ti_{0.48})O_3)$ powder was also synthesized successfully by the ethylene glycol method. In this study, the characteristics of the multi-component titanate powders by the ethylene glycol method are examined.

  • PDF

A Study on Heart Rate Variabilities during Graded Head-up Tilt (점증적 틸트 각도 변화에 대한 심박변동에 관한 연구)

  • Jeong, K.S.;Shin, K.S.;Lee, J.W.;Choi, S.J.;Ahn, J.;Chon, J.S.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.406-409
    • /
    • 1997
  • In this paper, the power spectral analysis and fractral dimension analysis of heart rate variability(HRV) were performed to evaluate effects of orthostatic stress with head-up tilt on autonomic nervous system(ANS) for 24 young and healthy subjects(age: $24{\pm}5yr$.). The ECG and respiration signals were recorded at the tilt angle of $0^{\circ},\;15^{\circ},\;30^{\circ},\;45^{\circ},\;70^{\circ}$ and $90^{\circ}$ successively for 5 minutes per each stage under the condition of frequency controlled respiration (0.25Hz). Heart rate(HR) gradually increased as the angle increased. Similarly, according to the increment of angle, normalized low frequency(LF) component(0.05-0.15Hz) gradually increased, whereas normalized high frequency(HF) component (0.20-0.30Hz) was reduced. From these results it is speculated that orthostatic stress, head-up tilt, results in the prevalence of sympathetic tone in autonomic balance with the increment of sympathetic tone and the decrement of parasympathetic tone, which seems to mean that autonomic nervous system plays a major role in compensating for disturbances of cardiovascular system due to it.

  • PDF

Evaluation on Hearing Conservation Program in the Noisy Industries (소음발생 산업장에서의 청력보존프로그램 평가)

  • Kwak, M.S.;Lee, J.T.;Kim, J.H.;Urm, S.H.;Kim, D.H.;Shon, B.C.;Lee, C.H.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.815-829
    • /
    • 1997
  • This study was performed to assist the employer to establish the effective program for hearing conservation of noisy industry. The study subjects were health care managers of an industry and the study industries were devided into two groups(Group I, 37 industries; have the workers diagnosed as noise-induced hearing loss, Group II, 41 industries; not have the workers diagnosed as noise-induced hearing loss) and the question method carried out through the face to face interview. The contents of questionnaire for OSHA's hearing conservation program(HCP) consisted of seven components: 5 questions of monitoring of employee noise exposures(component 1), 6 questions of the institution of engineering, work practice, and administrative controls for excessive noise(component 2), 8 questions of the provision of each overexposed employee with an individually fitted hearing protector with an adequate noise reduction rating(component 3), 14 questions of employee training and education regarding noise hazards and protection measures(component 4), 9 questions of baseline and annual audiometry(component 5), 3 questions of procedures for preventing further occupational hearning loss by an employee whenever such an event has been identified(component 6), and 1 question of recording keeping(component 7), thus total numbers of questions was 46. The numbers of statistially significant difference(p<0.05) between two groups were 2(25.0%) among 8 questions of component 3, 10(71.4%) among 14 questions of component 4, 3(33.3%) among 8 questions of component 5, 2(6.7%) among 3 questions of component 6, and 17(37.0%) among total 46 questions of questionnaire. Above results showed that the level of HCP acceptance in group I was lower than in group II. Thus employer's understanding about HCP should be precede for the effective hearing conservation program of employee and the adequate hearing protector, training and education, baseline and annual audiometry, and procedures for preventing further occupational hearning loss for hearing conservation would be more emphasized.

  • PDF