• Title/Summary/Keyword: $H_2S$ & $C_3H_8$ Gas

Search Result 189, Processing Time 0.03 seconds

Environmental Isotope Characteristics of $CO_2$-rich Water in the Kangwon Province (강원도지역 탄산수의 환경동위원소적 특성)

  • 최현수;고용권;김천수;배대석;윤성택
    • Economic and Environmental Geology
    • /
    • v.33 no.6
    • /
    • pp.491-504
    • /
    • 2000
  • Environmental isotope $^{18}O$, $^{2}H$, $^{3}H$,$^{13}C$, $^{34}S$and $^{87}Sr/^{86}Sr$) studies on ${CO_2}$-rich waters in the Kangwon Province were carried out to elucidate the origin, residence time, water-rock interaction and mixing process of their. ${\delta}^{18}O$ and ${\delta}D$ data indicate that ${CO_2}$-rich waters were derived from the local meteoric water. It also shows that each type of ${CO_2}$-rich water has distinct isotopic composition and Na-${HCO_3}$ type water (-10.8 to -12.1${\textperthousand}$, ${\delta}^{18}O$ ) is lighter than other type waters. These depleted isotopic values supposedly indicate that, considering the altitude effect of isotope in Korea, the recharge area of Na-${HCO_3}$ type water can be estimated to be relatively higher in elevation than those of Ca-${HCO_3}$ and Ca-Na-${HCO_3}$ type waters. Tritium contents close to zero are observed in the Na-${HCO_3}$ type water, confirming a long residence time and the possibility of a ${CO_2}$ inflow into the aquifer at great depth. These isotope data also show that the Ca-${HCO_3}$ type water has undergone mixing process with surface water during ascending at depth, whereas Na-${HCO_3}$ type water was less mixed with surface waters. The carbon isotope data (-8.8 to +0.8 ${\textperthousand}$ ${\delta}^{13}C$) indicate that dissolved carbon in the ${CO_2}$-rich waters was possibly derived from deep seated ${CO_2}$ gas. The high ${\delta}^{34}S$ values (up to 38.1${\textperthousand}$) of dissolved sulfates suggest that sulfate reduction by microbial activity had occurred at depth. Strontium isotopic data ($^{87}Sr/^{86}Sr$) of ${CO_2}$-rich waters indicate that the chemistry of the ${CO_2}$-rich waters is determined by water-rock (granite) interaction.

  • PDF

Effects of Addition Level and Chemical Type of Propionate Precursors in Dicarboxylic Acid Pathway on Fermentation Characteristics and Methane Production by Rumen Microbes In vitro

  • Li, X.Z.;Yan, C.G.;Choi, S.H.;Long, R.J.;Jin, G.L.;Song, Man K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.1
    • /
    • pp.82-89
    • /
    • 2009
  • Two in vitro experiments were conducted to examine the effects of propionate precursors in the dicarboxylic acid pathway on ruminal fermentatation characteristics, $CH_4$ production and degradation of feed by rumen microbes. Fumarate or malate as sodium salts (Exp. 1) or acid type (Exp. 2) were added to the culture solution (150 ml, 50% strained rumen fluid and 50% artificial saliva) to achieve final concentrations of 0, 8, 16 and 24 mM, and incubated anaerobically for 0, 1, 3, 6, 9 and 12 h at $39^{\circ}C$. For both experiments, two grams of feed consisting of 70% concentrate and 30% ground alfalfa (DM basis) were prepared in a nylon bag, and were placed in a bottle containing the culture solution. Addition of fumarate or malate in both sodium salt and acid form increased (p<0.0001) pH of culture solution at 3, 6, 9 and 12 h incubations. The pH (p<0.0001) and total volatile fatty acids (VFA, p<0.05) were enhanced by these precursors as sodium salt at 3, 6 and 9 h incubations, and pH (p<0.001) and total VFA (p<0.01) from fumarate or malate in acid form were enhanced at a late stage of fermentation (9 h and 12 h) as the addition level increased. pH was higher (p<0.001) for fumarate than for malate as sodium salt at 3 h and 6 h incubations. Propionate ($C_3$) proportion was increased (p<0.0001) but those of $C_2$ (p<0.05) and $C_4$ (p<0.01 - p<0.001) were reduced by the addition of sodium salt precursors from 3 h to 12 incubation times while both precursors in acid form enhanced (p<0.011 - p<0.0001) proportion of $C_3$ from 6h but reduced (p<0.018 - p<0.0005) $C_4$ proportion at incubation times of 1, 3, 9 and 12 h. Proportion of $C_3$ was increased (p<0.05 - p<0.0001) at all incubation times by both precursors as sodium salt while that of $C_3$ was increased (p<0.001) from 6h but $C_4$ proportion was decreased by both precursors in acid form as the addition level increased. Proportion of $C_3$ was higher (p<0.01 - p<0.001) for fumarate than malate as sodium salt from 6 h incubation but was higher for malate than fumarate in acid form at 9 h (p<0.05) and 12 h (p<0.01) incubation times. Increased levels (16 and 24 mM) of fumarate or malate as sodium salt (p<0.017) and both precursors in acid form (p<0.028) increased the total gas production, but no differences were found between precursors in both chemical types. Propionate precursors in both chemical types clearly reduced (p<0.0001 - p<0.0002) $CH_4$ production, and the reduction (p<0.001 - p<0.0001) was dose dependent as the addition level of precursors increased. The $CH_4$ generated was smaller (p<0.01 - p<0.0001) for fumarate than for malate in both chemical types. Addition of fumarate or malate as sodium type reduced (p<0.004) dry matter degradation while both precursors in both chemical types slightly increased neutral detergent fiber degradability of feed in the nylon bag.

Effect of Preparation method and Fermentation Conditions on Microbiological Characteristics of Sikhae (어류를 이용한 식해의 제조 방법에 따른 미생물의 특성변화)

  • Kim, Young-Sook;Oh, Seung-Hee;Kim, Soon-Dong
    • Food Science and Preservation
    • /
    • v.15 no.6
    • /
    • pp.909-914
    • /
    • 2008
  • This study investigated microbial populations and the sensory quality of sikhae including globefish (GLS), flounder (FLS), gastropods (GAS) and whelks (WHS) during storage at 4C for 16 d following fermentation at 10C for 4 d. General bacterial numbers increased to 102 in GLS and FLS, and to 1045 in WHS and GAS after the 20 d fermentation/storage period. Lactic acid bacteria increased to 108 log cycle in GLS and FLS after 10 d ripening time, and reached this level in GAS and WHS after 15 d and 20 d, respectively. After 20 days the number of lactic acid bacteria in each of the four samples was 108. There were 104105 yeast cells/g in each of the four samples after 20 d. The number of Leuconostoc increased to over 108 log cycle after 10 d in GLS and FLS, and 15 days in GAS for WHS the increase was to 107 log cycle. The pH values of GLS, FLS, GAS and WHS 4.42, 4.56, 4.31 and pH 4.26, respectively. The Sikhae acidity for all four samples ranged from 1.551.85%. From the sensory evaluation the overall acceptability was in the order of FLS > GLS > GAS > WHS.

Effect of Dandelion (Traxancum platycarpum D.) Extracts on the Growth of Lactic Acid Bacteria and Gas Formation from Kimchi (민들레 (Traxancum platycarpum D.) 추출물이 젖산균의 생육과 김치의 가스발생에 미치는 영향)

  • Kim, Soon-Dong;Kim, Mee-Hyang;Kim, Duck-Hee
    • Food Science and Preservation
    • /
    • v.7 no.3
    • /
    • pp.321-325
    • /
    • 2000
  • This study was conducted to investigate the effect of the extracts (water, 70% ethanol and ethylacetate) from dandelion (Traxancum platycarpum D.) leaf and root on the inhibitory activities of Leuconostoc mesenteroides, Lactobacillus brevis, Lactobacillus plantarum and Lactobacillus acidophilus. And also, the amounts of gas formation from kimchi with different concentration of the ethylacetate extracts (EE) were analyzed. EE of dandelion leaf inhibited the growth of Leuc. mesenteroides and L. acidophilus, and L. brevis by 50 and 33% at concentration of 0.5%, respectively. But no affected in L. plantarum estimated by pH, acidity, turbidity and clear zone. And no difference was founded in leaf and root. Gas was formed from the soaking day to 5-6 days of fermentation at $20^{\circ}C$, and the accumulated gas volumes were 80 ml/100 g in control, 30 ml/100 g in 0.5% EE, 8 ml/100 g in 1.0% EE.

  • PDF

A Study on Characteristics of Wood Pellet Gasification in Two Stage Gasifier (Two Stage Gasifier에서의 우드펠릿 가스화 특성 연구)

  • Lee, Moon-Won;Choi, Sun-Yong;Kim, Lae-Hyun
    • Journal of Energy Engineering
    • /
    • v.19 no.4
    • /
    • pp.240-245
    • /
    • 2010
  • In this study, characteristics of wood pellet gasification was studied using a Two Stage Gasifier which is consisted of pyrolysis reactor and ultra high temperature reformer. The average yields of $H_2$, $CH_4$, CO, $CO_2$ were 16.7, 11.3, 37.2, 26.6 L/mim, conversion rate from biomass to gas was 65% in pyrolysis reactor and gas yields in reformer were 55.4, 0.8, 120.8, 56.8 L/mim, respectively. The hydrogen flow rate from reformer is obtained 360.1 L/hr. The most of $CH_4$ was decomposed from 12.3 to 0.3 vol.% while $H_2$ is from 18.2 to 23.7 vol.% in reformer by methane dry reforming, Boudouard reaction, oxidation and/or steam reforming. The amount of $H_2O$ generated by hydration reaction from reformer was 1111.8 g, its accelerated conversion of $CH_4$ to other products. The conversion rate from $CH_4$ to other Compounds was 97.2%. Cold gas efficiency was 53.2%.

Performance of a Biofilter for Odor Removal during Manure Composting

  • Park, K.J.;Hong, J.H.;Choi, M.H.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.59-64
    • /
    • 2002
  • Odor generated during composting of livestock manure is mainly due to ammonia emission. Biofiltration is a desirable method to control composting odor. This study was conducted to analyze the efficiency of using fresh compost as a biofilter. A mixture of cattle manure and recycled compost was composted in a bin equipped with a suction-type blower. The exhaust gas was filtered through the fresh compost. Residence time was controlled by the flow rate of exhaust gas and the depth of filtering materials. At the aeration rate of 30 L/min(experiment I), ammonia reduction rate varied from 100% to -15% for biofilter A(residence time 56.5 s) and almost 100% for biofilter B(residence time 113 s). At the aeration rate of 30 L/min, the cumulative ammonia reduction rate was 80.5% for biofilter A and 99.9% for biofilter B. At the aeration rate of 50 L/min(experiment II), the lowest reduction rate showed a negative value of -350% on the 8th and 9th day for biofilter A(residence time 33.9 5), and 50% on the loth day for biofilter B(residence time 67.8s). At the aeration rate of 50 L/min, the cumulative ammonia reduction rate was 82.5% fur biofilter A and 97.4% for biofilter B. Filtering efficiency was influenced by residence time. The moisture content(MC) and total nitrogen(T-N) of the filtering material were increased by absorbing moisture and ammonia included in the exhaust gas, while pH was decreased and total carbon(T-C) remained unchanged during the filtering operation.

  • PDF

$CO_2$ Removal Process Case Studies and Plant Performance Analysis for 300MW IGCC Power Plant (300MW 급 IGCC Power Plant $CO_2$ 제거공정의 Case Studies 및 Plant 성능 영향 분석)

  • Jeon, Jinhee;Yoo, Jeongseok;Paek, Minsu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.71.2-71.2
    • /
    • 2011
  • 300MW 급 태안 IGCC 가스화 플랜트 및 기존 발전소에 CCS 를 설치할 경우에 대해 기술 타당성 검증을 목적으로 CCS 모델링을 수행하였다. CCS Case Studies 는 플랜트 운전부하에 따른 $CO_2$ 제거율, $H_2S$ 제거율, 소모동력 범위 등 플랜트 성능을 예측할 수 있다. Case Studies 결과를 활용하여 설계된 CCS 설비 용량이 운전범위에 적합한지를 판단할 수 있고 과잉 설계되었을 경우 플랜트 건설비를 절감할 수 있다. IGCC 가스화 플랜트에서 생산되는 합성가스의 $CO_2$ 분압, 목표 $CO_2$ 제거율, 경제성을 기준으로 적합한 CCS 공정을 판단한 결과 Selexol 공정이 선정되었다. Selexol 공정은 고압, 고농도의 산성가스 제거에 적합하며 다른 물리적 용매인 Rectisol 공정에 비해 건설비용이 경제적이고 화학 흡수제인 아민과 비교하여 운전 온도 범위가 넓다. CO, $H_2O$$CO_2$, $H_2$ 로 전환하는 Water Gas Shift Reaction (WGSR) 공정은 Co/Mo 촉매 반응기로 구성되었고 Selexol 공정은 $H_2S$ Absorber, $H_2S$ Stripper, $CO_2$ Absorber, $CO_2$ Flash Drum 로 구성되었다. WGSR+Selexol 모델링은 Wet Scrubber 후단의 합성가스 (40.5 bar, $136{\sim}139^{\circ}C$) 를 대상으로 하였다. WGSR+Selexol 공정 운전 조건 변화 [Process Design Case(PDC), Equipment Design Case(EDC), Turndown Design Case(TDC)] 에 따른 플랜트 모델링 결과를 비교분석 하였다. 주요 분석 내용은 WGSR 설비에서의 CO 의 $CO_2$ 전환 효율, Selexol 설비에서 $CO_2$ 제거 효율, $H_2S$ 제거 효율이다. 모델링 결과 WGSR 설비에서의 CO 의 $CO_2$ 로의 전환율 99.1% 이상, Selexol 설비에서 $CO_2$ 제거율은 91.6% 이상, $H_2S$ 제거율 100%이었다. CCS 설비 설치에 따른 플랜트 성능 영향을 분석하기 위해서 CCS 설비의 Chiller, Compressor, Pump 소비동력을 계산하였다. 모델링 결과 Chiller 는 2.6~8.5 MWth, Compressor 는 3.0~9.6 MWe, Pump 는 1.4~3.0 MWe 범위 이었다. 플랜트 로드가 50%인 TDC 소모동력은 플랜트 로드가 100%인 PDC 소모동력의 절반 수준이었다. 합성가스를 WGS+Selexol 공정을 통해 수소가스로 전환시키면 가스터빈 연료가스의 Lower Heating Value (LHV) 값이 평균 11.5% 감소하였다.

  • PDF

A Brief Investigation on the Performance Variation and Shelf Lifetime in Polymer:Nonfullerene Solar Cells

  • Lee, Sooyong;Kim, Hwajeong;Lee, Chulyeon;Kim, Youngkyoo
    • Current Photovoltaic Research
    • /
    • v.7 no.3
    • /
    • pp.55-60
    • /
    • 2019
  • Polymer:nonfullerene solar cells with an inverted-type device structure were fabricated by employing the bulk heterojunction (BHJ) active layers, which are composed of poly[(2,6-(4,8-bis(5-(2-ethylhexyl)thiophene-2-yl)-benzo[1,2-b:4,5-b']dithiophene))-alt-(5,5-(1',3'-di-2-thienyl-5',7-bis(2-ethylhexyl)benzo[1',2'-c:4',5'-c']dithiophene-4,8-dione))] (PBDB-T) and 3,9-bis(6-methyl-2-methylene-(3-(1,1-dicyanomethylene)-indanone))-5,5,11,11-tetrakis(4-hexylphenyl)-dithieno[2,3-d:2',3-d']-s-indaceno[1,2-b:5,6-b']dithiophene (IT-M). The BHJ layers were formed on a pre-patterned indium-tin oxide (ITO)-coated glass substrate by spin-coating using the blend solutions of PBDB-T and IT-M. The solar cell performances were investigated with respect to the cell position on the ITO-glass substrates. In addition, the short-term shelf lifetime of solar cells was tested by storing the PBDB-T:IT-M solar cells in a glovebox filled with inert gas. The results showed that the performance of solar cells was relatively higher for the cells close to the center of substrates, which was maintained even after storage for 24 h. In particular, the PCE of PBDB-T:IT-M solar cells was marginally decreased after storage for 24 h owing to the slightly reduced fill factor, even though the open circuit voltage was unchanged after 24 h.

Thermal stress and Flow Analysis of a Cryogenic Ball Valve (초저온 볼밸브의 열 응력 및 유동해석)

  • Bae, S.K.;Lee, W.H.;Kim, H.S.;Kim, D.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.4
    • /
    • pp.8-13
    • /
    • 2006
  • The high pressure cryogenic ball valve is used to transfer the liquefied natural gas which temperature is $-196^{\circ}C$, supplied pressure is $168kgf/cm^2$. In the present work, the temperature distribution and thermal deformation is calculated numerically. The CAR and CFD methods are useful to predict the thermal matter and the inner flow field of high pressure cryogenic ball valve. For this reason, to optimum design of the cryogenic ball valve, the theological behavior of the supplied LNG in a cryogenic valve has been studied. The governing equations are discredited and solved numerically by the finite-volume method and finite-element method. In this study, we designed the high pressure cryogenic ball valve that accomplishes zero leakage by elastic seal at normal temperature and metal seal at high temperature.

  • PDF

The Effect of SO2 and H2O on the NO Reduction of V2O5-WO3/TiO2/SiC Catalytic Filter (V2O5-WO3/TiO2/SiC 촉매필터의 NO 환원에 SO2와 H2O가 미치는 영향)

  • Ha, Ji-Won;Choi, Joo-Hong
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.688-693
    • /
    • 2014
  • For investigating NO reduction activity of an catalytic filter, the catalytic performance was measured under the presence of $SO_2$ and $H_2O$, respectively or simultaneously in the simulation gas composed of NO, $NH_3$, and air. The catalytic filter was prepared by coating $V_2O_5-WO_3/TiO_2$ catalyst on the pore surface of SiC filter element of which the superior performance for the particulate removal was well known. At the temperature below $260^{\circ}C$, the catalytic activities were enormously decreased under the presence of $SO_2$ and $H_2O$, respectively or simultaneously, compared with those under the cases of the absence of $SO_2$ and $H_2O$. However, the presence of $SO_2$ promoted the performance of the catalytic filter above $320^{\circ}C$ with showing the NO conversion better than 99.8% for the NO inlet concentration of 500 ppm and at the face velocity of 2 cm/s. In particular, the presence of water showed high NO conversion higher than 99% up to high temperature of $380^{\circ}C$. This effect of water was explained by the reason that it retarded the ammonia oxidation which is the main step into the formation of $N_2O$. The initial NO reduction activity of the catalytic filter maintained for the duration of 100 hours in the presence of $SO_2$ and $H_2O$. Therefore, it was concluded that the catalytic filter was promisingly useful for the industrial NOx reduction catalyst in order to treat the particulate and NO simultaneously.