• Title/Summary/Keyword: $Cr^{+6}$

Search Result 2,919, Processing Time 0.038 seconds

C2H5OH Sensor Using Porous Cr2O3 Nano-Hexaprisms (다공성 Cr2O3 나노육각기둥을 이용한 C2H5OH 센서)

  • Jeong, Hyun-Mook;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.451-455
    • /
    • 2012
  • Dense Cr-precursor nano-hexaprisms were prepared by heating the Cr-nitrate aqueous solution containing Hexamethylenetetramine and polyvinylpyrrolidone, which were converted into porous $Cr_2O_3$ nano-hexaprisms containing nanoparticles by heat treatment of Cr-precursors at $600^{\circ}C$ for 2 h in air atmosphere. At the sensor temperature of $300^{\circ}C$, porous $Cr_2O_3$ nano-hexaprism showed the high response ($R_g/R_a$, $R_g$: resistance in gas, $R_a$: resistance in air) to 100 ppm $C_2H_5OH$ ($R_g/R_a=69.8$) with negligible cross-responses to 100 ppm CO and 5 ppm $C_6H_6$. The sensitive and selective detection of $C_2H_5OH$ in porous $Cr_2O_3$ nano-hexaprism were discussed in relation to the morphology of nanostructures.

High Temperature Stability for Refractories of the System $Al_2O_3-CaO-Cr_2O_3$ ($Al_2O_3-CaO-Cr_2O_3$ 계 내화물의 고온 안정성)

  • 이홍립
    • Journal of the Korean Ceramic Society
    • /
    • v.17 no.1
    • /
    • pp.8-12
    • /
    • 1980
  • CaO was added to the $MgAlCrO_4$ spinel, a main component of the mag-chro refractroies, by 0, 1, 5 and 10 mol% before sintering at 135$0^{\circ}C$ in air. The X-ray diffraction analysis produced an additional X-ray diffraction pattern of 8CaO.$6Al_2O_3$.$2CrO_3$ besides that of $MgAlCrO_4$. The formation of 8CaO.$6Al_2O_3$.$2CrO_3$ was interpreted as due to the presence of CaO.8CaO.$6Al_2O_3$.$2CrO_3$ was unstable and easily vaporized. It was concluded that formation of the unstable pollutant 8CaO.$6Al_2O_3$.$2CrO_3$ could be prevented in reducing atmospheres. It was found that the basic refractories containing $Al_2 O_3 -CaO-Cr_2 O_3$ system would be more stable and much less toxic in reducing at mospheres than in oxidizing stmosphere.

  • PDF

Ferroelectric Properties of Substituted Aurivillius Phases SrBi2Nb2-xMxO9 (M=Cr, Mo)

  • Moon, S.-Y.;Choi, K. S.;Jung, K. W.;Lee, H.;Jung, D.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.10
    • /
    • pp.1463-1482
    • /
    • 2002
  • Partially doped Aurivillius phases SrBi2N$b_{2-x}M_xO_9$ (M=Cr and Mo) were successfully synthesized and characterized. The extent of the substitution was limited at ~20 mole % because of the size differences between $Nb^{5+}$ and $Cr^{6+}$, and between $Nb^{5+}$ and $Mo^{6+}$. When the amount of substitution exceeded ~20 mole%, the phases began to collapse and the second phases were made. The dielectric constants of substituted compounds were enlarged nevertheless Cr or Mo is substituted. The increment is bigger in the Mo substituted compound than in the Cr doped one although the Nb(Cr)$O_6$ octahedra could be more strongly distorted than the Nb(Mo)$O_6$ octahedra since the ionic size difference between $Nb^{5+}$ and of $Cr^{6+}$ is much bigger than that between $Nb^{5+}$ and $Mo^{6+}$. Consequently, the dielectric constant of the substituted Aurivillius phase $Bi_2$A_{n-1}B_{n-x}M_xO_{3n+1}$$ depends on the extent of distortion of the B$O_6$ octahedra and more strongly on the polarizability of the metal.

Estimation of Glomerular Filtration Rate using Chromium-51 EDTA (Cr-51 EDTA GFR 검사 결과의 분석 및 의의)

  • Lim, Soo-Yeon;Moon, Hyoung-Ho;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.98-103
    • /
    • 2009
  • Purpose: Correct estimation of Glomerular filtration rate (GFR) is very important for an accurate clinical assessment of the kidney function. This study compares four GFR markers, a serum creatinine-based estimation using MDRD formula, Cystatin-C, Cr-51 EDTA 2 samples and 6 samples. Materials and Methods: Serum creatinine concentrations, Cystatin-C serum concentrations and Cr-51 EDTA clearance are measured in 43 patients who received or donated kidney. Results: The correlation coefficient between serum based estimated GFR (MDRD) and Cr-51 EDTA 6 samples was 0.817 (p<0.01). The correlation coefficient between Cystatin-C based GFR and EDTA 6 samples was 0.7322 (p<0.01). Regression analysis showed a statistically significant correlation between Cr-51 EDTA 2 samples and 6 samples (r=0.971, p<0.01). Mean value and ${\pm}2SD$ for the difference between Cr-51 EDTA 2 samples and 6 samples were 4.7 mL/min and ${\pm}9.3$ respectively. Conclusions: The estimation of two samples Cr-51 EDTA showed that the method can be simplified by reducing blood samples without losing its high accuracy.

  • PDF

Microstructure and Mechanical Properties of Cr-Mo Steels for Nuclear Industry Applications

  • Kim, Sung-Ho;Ryu, Woo-Seong;Kuk, Il-Hiun
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.561-571
    • /
    • 1999
  • Microstructure and mechanical properties of five Cr-Mo steels for nuclear industry applications have been investigated. Transmission electron microscopy, energy dispersive spectrometer, differential scanning calorimeter, hardness, tensile, and impact test were used to evaluate the Cr and W effect on the microstructure and mechanical properties. Microstructures of Cr-Mo steels after tempering are classified into three types : bainitic 2.25Cr-lMo steel, martensitic Mod.9Cr-lMo, HT9M, and HT9W steels, and dual phase HT9 steel. The majority of the precipitates were found to be M$_{23}$C$_{6}$ carbides. As minor phases, fine needle-like V(C,N), spherical NbC, fine needle-like Cr-rich Cr$_2$N, and Cr-rich M$_{7}$C$_3$were also found. Addition of 2wt.% W in Cr-Mo steels retarded the formation of subgrain and dissolution of Cr$_2$N precipitates. Hardness and ultimate tensile strength increased with increasing Cr content. Though Cr content of HT9W steel was lower than that of HT9 steel, the hardness of HT9W was higher due to the higher W content. W added HT9W steel had the highest ultimate tensile strength above $600^{\circ}C$. But impact toughness of W added steel (HT9W) and high Cr steel (HT9) was low.w.w.

  • PDF

Sonochemical Synthesis of Fullerene Oxides $[C_{70}O_n](n=1{\sim}2)$ Using Metal Hexacarbonyl Complexes $M(CO)_6$ (M=Cr, Mo, W) Under Air Atmosphere (공기 중에서 금속 헥사카르보닐 착물 $M(CO)_6$ (M=Cr, Mo, W)를 이용한 폴러렌 산화물 $[C_{70}O_n](n=1{\sim}2)$의 초음파화학 합성)

  • Ko, Weon-Bae;Park, Young-Hwan
    • Elastomers and Composites
    • /
    • v.40 no.3
    • /
    • pp.174-180
    • /
    • 2005
  • Sonochemical synthesis of fullerene oxides $[C_{70}O_n](n=1{\sim}2)$ by fullerene$[C_{70}]$ and metal hexacarbonyl complexes $M(CO)_6$(M=Cr, Mo, W) took place under air atmosphere. The reactivity of fullerene$[C_{70}]$ and several metal hexacarbonyl complexes $M(CO)_6$(M=Cr, Mo, W) under same ultrasonic condition increased in the order of $Mo(CO)_6$ > $W(CO)_6$ > $Cr(CO)_6$. The MALDI-TOF-MS, UV-visible spectra, and HPLC analysis confirmed that the products of sonochemical reaction were $[C_{70}O_n](n=1{\sim}2)$.

Toxic Effects of Arsenic and Chromium on the Fertilization and Embryo Development Rates in the Sea Urchin (Hemicentrotus pulcherrimus) (말똥성게(Hemicentrotus pulcherrimus)의 수정 및 배아 발생률에 대한 비소와 크롬의 독성영향)

  • Hwang, Un-Ki;Ryu, Hyang-Mi;Yu, Jun;Kang, Han-Seung
    • Korean Journal of Environmental Biology
    • /
    • v.31 no.2
    • /
    • pp.69-77
    • /
    • 2013
  • Toxic effects of arsenic (As) and chromium (Cr) has been investigated using the sea urchin (Hemicentrotus pulcherrimus) germ cell and pluteus-larvae. The gametotoxic and embryotoxic effects of As and Cr on H. plucherrimus were each investigated at 6.25, 12.5, 25, 50, 100. Spawning was induced by 0.5 M KCl solution and the normal fertilization and embryogenesis rates were performed for 10 min and 64 hrs after fertilization, respectively. The normal fertilization and embryogenesis rates in the control condition (not including As and Cr) were greater than 94% and 93%, respectively. The fertilization rate was not significantly changed compared with control but embryogenesis rate was significantly decreased with concentration-dependent manner. As and Cr reduced normal embryogenesis rates and a significant reduction occurred at concentration greater than 6.25 ppb (P<0.01) and 25 ppb (P<0.05), respectively. The lowest-observedeffect- concentration (LOEC) of normal embryogenesis rate in As and Cr were each 6.25 and 25 ppb, respectively. From these results, normal embryogenesis rate of H. pulcherrimus have toxic effect at greater than the 6.25 ppb concentration of As and 25 ppb concentration of Cr in marine ecosystems. These results suggest that the normal embryogenesis rates of H. pulcherrimus are very useful test method for the toxicity assessment of heavy metal as As and Cr in marine ecosystems.

Adsorption Characteristics of Chromium Ion at Low Concentration Using Oxyfluorinated Activated Carbon Fibers (함산소불화 활성탄소섬유를 이용한 저농도 크롬이온의 흡착 특성)

  • Kim, Min-Ji;Jung, Min-Jung;Choi, Suk Soon;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.26 no.4
    • /
    • pp.432-438
    • /
    • 2015
  • In this work, activated carbon fibers (ACFs) were oxyfluorinated and their adsorption ability for the low concentration of hexavalent chromium in an aqueous solution was investigated. The pore structure and surface properties of ACFs were examined by BET and X-ray Photoelectron Spectroscopy (XPS), respectively. Due to the oxyfluorination treatment, the content of (C-O) bond on ACFs surface which influences the adsorption capacity for heavy metal ions increased largely, resulting that $Cr^{6+}$ adsorption equilibrium reached quickly within 10 min. In addition, the maximum removal efficiency at the initial $Cr^{6+}$ concentration of 20 ppm was observed, which is a 100% improvement compared to that of non-treated ACFs. These results suggest that the oxyfluorination of ACFs can be applied as a good surface treatment for the effective adsorption of the low concentration of $Cr^{6+}$.

Reduction of hexavalent chromium (Cr(VI)) under acidic conditions during its determination in cement (시멘트 6가 크롬 (Cr(VI))정량분석법에 관한 고찰 - 분석과정에서 Cr(VI) 의 환원에 따른 오차제어-)

  • Moon, Se-Heum;Jeong, Jae-Hong;Lee, Seung-Hoon;Lee, Seung-Heun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.897-900
    • /
    • 2008
  • Some substances of cement could make underestimate concentration of hexavalent chromium(Cr(VI)) as they reduce Cr(VI) to Cr(III) in acidic condition during the determination of Cr(VI) content in cement. The reduction of Cr(VI) increased with elapsed time after acidification in this study. The reduction rate varied with various cements. From our result, we can conclude that simultaneous additions of acid and DPC were required for the accurate measurement of Cr(VI) in cement. The high recovery rate of 94.3 to 106.7% with the simultaneous acid-DPC addition method can also support our conclusion.

  • PDF

Tribology and Phase Evolution of Cr-Mo-N Coatings with Different Interlayer Condition (중간층 조건에 따른 Cr-Mo-N 막의 상형성 및 마찰마모 거동 연구)

  • Yang, Young-Hwan;Lyo, In-Woong;Park, Sang-Jin;Im, Dae-Sun;Oh, Yoon-Suk
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.6
    • /
    • pp.269-276
    • /
    • 2011
  • Phase evolution and tribological behavior of Cr-Mo-N multi compositional films with different interlayer were investigated. The films were deposited by hybrid PVD (Physical Vapor Deposition) system consisted of dc unbalanced magnetron (UBM) sputtering and arc ion plating (AIP) sources. A pure molybdenum (Mo) was used as sputtering target and also a pure Cr was used as AIP target to form the Cr-Mo-N films. Various growth planes were found, no textured surface, in all of the multi composition films. Maximum value of microhardness was measured in Cr-Mo-N film with Mo interlayer as 29 GPa. Composition film was mainly showed the aspect of the adhesive wear than CrN film. The friction coefficient was decreased from 0.6 for pure CrN coating to 0.35 for Cr-Mo-N film with Mo interlayer. This result may come from the formation of metal oxide tribo-layer which is known as solid lubricant during the wear test.