• 제목/요약/키워드: $CO_2$ response

검색결과 1,580건 처리시간 0.025초

A Study on Risk Response against Ship Fire using Robot

  • Park, Dea-Woo;Park, Young-Suk;Nam, Jae-Min
    • Journal of information and communication convergence engineering
    • /
    • 제9권2호
    • /
    • pp.230-234
    • /
    • 2011
  • It is endeavoring for sea safety and fire[1] at sea prevention solidifying control of standard technology and safety supervision aspect in IMO[2] but sea accident and ship fire are happening continuously. Because using Robot in artistic talent of ship in this treatise, studied that correspond to Risk and manage. Attach fire perception sensor for Robot's Risk confrontation, and because using infrared rays sensor, TOUCH SWITCH, sound perception sensor, gas perception sensor, light perception sensor that is threaded in Robot and is achieved, controlled Robot, and establish Low-High value the speed of sound output use and DC MOTOR and COM SEN of when indicate Risk confrontation to Robot and establish Robot's Risk confrontation administration action.

Pharmacokinetic-Pharmacodynamic Modeling of a Direct Thrombin Inhibitor, Argatroban, in Rats

  • Park, Eun-Hye;Shin, Beom-Soo;Yun, Chi-Ho;Lee, Mann-Hyung;Yoo, Sun-Dong
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권5호
    • /
    • pp.373-379
    • /
    • 2009
  • This study was conducted to develop a pharmacokinetic-pharmacodynamic (PK/PD) model of a direct thrombin inhibitor, argatroban to predict the concentration-effect profiles in rats. Argatroban was i.v. injected to rats at 0. 2, 0.8 and 3.2 mg/kg doses (n = 4-5 per dose), and plasma drug levels were determined by a validated LC/MS/MS assay. The pharmacokinetics of argatroban was linear over the i.v. dose range studied. The thrombin time (TT) and the activated partial thromboplastin time (aPTT) were measured in rat plasma and they were found to linearly increase with increasing the dose. A 2-compartment pharmacokinetic model linked with an indirect response pharmacodynamic model was successfully utilized to evaluate the drug concentration-response relationship.

Polymeric Acetate-Selective Electrodes Based on meso-(α,α,α,α)-Tetrakis-[(2-arylphenylurea)phenyl]porphyrins: Electormic and pH Effects

  • Lee, Hyo-Kyoung;Song, Ki-ju;Seo, Hyung-Ran;Jeon, Seung-won
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권10호
    • /
    • pp.1409-1412
    • /
    • 2002
  • Polymeric membrane electrodes for acetate anion based on meso-(${\alpha}$,${\alpha}$,${\alpha}$,${\alpha}$)-5,10,15,20-tetrakis[2-(penta-fluorophenylurea) phenyl]porphyrin I and similar urea-functionalized porphyrins Ⅱ-Ⅳ as neutral ionophores were prepared. The membrane based on porphyrin I exhibits the best potentiometric properties in pH 6.0 rather than pH 7.0: linear stable response over a wide concentration range (6.0 ${\times}$$10^{-5}$-1.0 ${\times}$$10^{-2}$) with a slope of -59.6 mV/decade and a detection limit of log[CH3CO$O^-$] = -5.32. Selectivity coefficients obtained from the matched potential method (MPM) in pH 6.0 indicate that interferences of hydrophobic anions are very small for the membranes of porphyrins I and II having the strong withdrawing group. The electronic effect of urea-functionalized porphyrins and pH effect of buffer solutions are discussed on the potentiometric response.

유압 안정화시스템의 강인제어에 관한 연구 (A Study on the Robust Control of Hydraulic Stabilizing System)

  • 조택동;서송호;양상민
    • 한국군사과학기술학회지
    • /
    • 제2권2호
    • /
    • pp.226-233
    • /
    • 1999
  • A transmitting antenna mounted on the naval vessels can be easily exited by exogenous disturbances such as wave and impact. Gimbal system need for the controller to maintain the robust performance against various modeling uncertainties and disturbances. PI controller, however, cannot supply good robust performance under situation. Thus a robust $H_{\infty}$ control scheme is used to ensure a specified dynamic response under above conditions. Gimbal system controlled simplified as 2 DOF system that ignored coordinate co-relations of each direction and hydraulic system is linearly modelled. In this paper, we compared those of simulation to the results of experiment and H$_{\infty}$ controller, proposed, showed the good response and stability than PI controller.

  • PDF

COVID-19 Therapeutics: An Update on Effective Treatments Against Infection With SARS-CoV-2 Variants

  • Bill Thaddeus Padasas;Erica Espano;Sang-Hyun Kim;Youngcheon Song;Chong-Kil Lee;Jeong-Ki Kim
    • IMMUNE NETWORK
    • /
    • 제23권2호
    • /
    • pp.13.1-13.24
    • /
    • 2023
  • The coronavirus disease 2019 (COVID-19) pandemic is one of the most consequential global health crises in over a century. Since its discovery in 2019, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continues to mutate into different variants and sublineages, rendering previously potent treatments and vaccines ineffective. With significant strides in clinical and pharmaceutical research, different therapeutic strategies continue to be developed. The currently available treatments can be broadly classified based on their potential targets and molecular mechanisms. Antiviral agents function by disrupting different stages of SARS-CoV-2 infection, while immune-based treatments mainly act on the human inflammatory response responsible for disease severity. In this review, we discuss some of the current treatments for COVID-19, their mode of actions, and their efficacy against variants of concern. This review highlights the need to constantly evaluate COVID-19 treatment strategies to protect high risk populations and fill in the gaps left by vaccination.

CO2농도 및 온도 상승이 하천변 잠재자연식생인 졸참나무와 갈참나무 잎의 형태학적 반응에 미치는 영향 (Effects of Elevated CO2 and Temperature on the Leaf Morphological Responses of Quercus serrata and Quercus aliena, Potential Natural Vegetation of Riverine)

  • 조규태;김해란;정헌모;유영한
    • 한국습지학회지
    • /
    • 제15권2호
    • /
    • pp.171-177
    • /
    • 2013
  • 한반도의 참나무 중 하천변 잠재자연식생인 졸참나무와 갈참나무를 대상으로 지구온난화의 핵심 요소인 $CO_2$농도와 온도를 상승시킬 때 잎의 형태학적 반응이 어떻게 일어나는지 알아보고자 유리온실 내에서 대기 중의 $CO_2$농도를 그대로 반영한 대조구와 이보다 $CO_2$농도는 약 1.6배와 온도는 $2.2^{\circ}C$상승시킨 온난화처리구에서 실험하여 관찰하였다. 그 결과, 졸참나무와 갈참나무는 $CO_2$농도와 온도의 상승으로 인하여 잎폭 길이, 잎몸 무게 그리고 엽면적이 증가하고 잎 수와 비엽면적은 감소하는 경향을 나타냈다. 졸참나무는 잎폭 길이, 잎몸 길이, 잎몸 무게, 잎 수, 엽면적 그리고 비엽면적 모두 대조구와 온난화처리구 간에 차이가 없었다. 그러나 갈참나무는 잎폭 길이와 잎몸 무게의 증가, 비엽면적의 감소가 뚜렷하였다. 이상의 잎의 형태학적 반응으로 볼 때, 갈참나무는 $CO_2$농도와 온도에 대하여 졸참나무 보다 민감하게 반응한다는 것을 알 수 있다. 주성분분석 결과, 두 종은 요인 1과 2에 의해 대조구와 온난화처리구에서 배열에 차이가 있었고, 온난화처리에 대한 변화는 졸참나무보다 갈참나무에서 명확히 구별되었다.

연소배가스 모니터링을 위한 $SnO_{2}$계 CO센서의 검지특성 (Sensing Characteristics of $SnO_{2}$ type CO sensors for combustion exhaust gases monitoring)

  • 김일진;한상도;임한조;손영목
    • 센서학회지
    • /
    • 제6권5호
    • /
    • pp.369-375
    • /
    • 1997
  • $SnO_{2}$$V_{2}O_{5}/ThO_{2}/Pd$를 도핑하여 제조된 센서는 약 $500^{\circ}C$의 높은 센서 온도에서 CO에 대해 우수한 선택도와 안전성 및 빠른 응답특성을 보였다. 특히, $V_{2}O_{5}$를 약 3.0 wt.% 첨가하여 선택도에 있어서 CO 감도에 대해 $NO_{x}$, $C_{3}H_{8}$, $CH_{4}$$SO_{2}$같은 많은 간섭가스들의 영향이 적음을 알았다. 센서 제조는 $V_{2}O_{5}$(3.0 wt.%), $ThO_{2}$(1.5wt.%), Pd(1.0 wt.%)의 촉매물질과 함께 기존에 잘 알려진 후막기술을 이용하였다. 일반적으로 연소배가스처럼 $NO_{x}$와 CO가 혼합되어 있는 복합가스의 경우, $SnO_{2}$계 반도체 센서로는 CO만의 검지는 $NO_{x}$ 간섭 때문에 대단히 어렵다. 본 센서는 공연비제어를 요하는 자동차나 보일러 시스템의 연소배가스의 측정과 감시에 사용할 수 있을 것이다.

  • PDF

실내 공기질 향상을 위한 비분산 적외선 이산화탄소 가스센서 (NDIR CO2 Gas Sensor for Improving Indoor Air Quality)

  • 이승환;박정민;박영환;한승오
    • 한국전기전자재료학회논문지
    • /
    • 제18권7호
    • /
    • pp.628-634
    • /
    • 2005
  • We have simulated and proposed novel optical cavity, which has two elliptical mirrors, for NDIR gas sensor module and have tested it from 0 ppm to 2,000 ppm $CO_2$ concentration. The proposed sensor module shows the maximum peak voltage at 500 ms pulse modulation time, however, it shows a maximum voltage changes at 200 ms pulse duration with 18,000 times amplification gain. From 0 ppm to 2,000 ppm, the voltage difference of sensor module $({\Delta}V)$ shows 360 mV at 200 ms pulse duration and 3 sec turn-off time. The response time of designed sensor module is about 30 seconds.

Quasi-Solid-State Hybrid Electrolytes for Electrochemical Hydrogen Gas Sensor

  • Kim, Sang-Hyung;Han, Dong-Kwan;Hong, SeungBo;Jeong, Bo Ra;Park, Bok-Seong;Han, Sang-Do;Kim, Dong-Won
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권3호
    • /
    • pp.294-301
    • /
    • 2019
  • The quasi-solid-state hybrid electrolytes were synthesized by chemical cross-linking reaction of methacrylate-functionalized $SiO_2$ ($MA-SiO_2$) and tetra (ethylene glycol) diacrylate in aqueous electrolyte. A quasi-solid-state electrolyte synthesized by 6 wt.% $MA-SiO_2$ exhibited a high ionic conductivity of $177mS\;cm^{-1}$ at room temperature. The electrochemical $H_2$ sensor assembled with quasi-solid-state electrolyte showed relatively fast response and high sensitivity for hydrogen gas at ambient temperature, and exhibited better durability and stability than the liquid electrolyte-based sensor. The simple construction of the sensor and its sensing characteristics make the quasi-solid-state hydrogen sensor promising for practical application.

SnO2를 이용한 CO 및 NOx 가스 감지 센서 제작 및 특성 연구 (Fabrication and Evaluation of the SnO2 Based Gas Sensor for CO and NOx Detection)

  • 김만재;이유진;안효진;이상훈
    • 한국자동차공학회논문집
    • /
    • 제23권5호
    • /
    • pp.515-523
    • /
    • 2015
  • In this paper, we fabricated and evaluated the gas sensor for the detection of CO gas and $NO_X$ gas among the vehicle exhaust emission gasses. The $SnO_2$ (tin dioxide) layer is used as the detection material, and the thin-film type and the nano-fiber type layers are deposited with various thicknesses using sputtering method and electro spinning method, respectively. The experiments are performed in the chamber where the gas concentration is controlled with mass flow controller. The fabricated devices are applied to the CO and $NO_X$ gas, where the device with the thinner $SnO_2$ layer shows better sensitivity. The nano-fiber has the larger surface area, and the shorter response time and recovery time are obtained. From the experimental results, both types of gas sensors successfully detect CO and $NO_X$ gases, which can be applied to measure those gases from the vehicle emissions.