• 제목/요약/키워드: $CO_2$ generator

검색결과 215건 처리시간 0.025초

유도형(誘導型) Pulsed Power 전원을 이용한 CO2 레이저 동작 특성에 관한 연구 (A Study on Operating Characteristics of the CO2 Laser with Inductively Pulsed Power System)

  • 김근용;민병대;김용철;이유수;정현주;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1710-1713
    • /
    • 2002
  • Recently, the pulsed power system has been used to many applications. Such as remediation of environmental hazards, food sterilization, air pollution control E/P (Electrostatic Precipitator), DeNOx/DeSOx power system, ozone generator, high energy physics, and other power source applications. A pulse energy efficiency for load depends on the rising time, peak value. Pulse duration and impedance matching etc. The pulsed power system generally required for short pulse duration and high peak value was forced to consider its volume and economy. In this paper, we investigated operating characteristics of the CO2 laser using an inductively pulsed power system.

  • PDF

초임계 CO2 발전용 파워터빈을 지지하는 틸팅패드 베어링의 열윤활 해석 및 패드 온도 측정 (Thermal Analysis and Temperature Measurement of Tilting Pad Bearings Supporting a Power Turbine for the Supercritical CO2 Cycle Application)

  • 이동현;김병옥;임형수
    • Tribology and Lubricants
    • /
    • 제34권2호
    • /
    • pp.43-48
    • /
    • 2018
  • This paper presents the thermohydrodynamic analysis of tilting journal pad bearings supporting a power turbine rotor applied to a 250 kW super-critical $CO_2$ cycle. In the analysis, the generalized Reynolds equation and 3D energy equation are solved to predict oil film temperature and the 3D heat conduction equation is solved for pad temperature. The power turbine rotor is supported by two tilting pad bearings consisting of five pads with an oil supply block between the pads. Copper backing pads with higher thermal conductivity compared to steel backing pads are adopted to improve thermal management. The predicted maximum pad temperature is around $55^{\circ}C$ which is approximately $15^{\circ}C$ higher than oil supply temperature. In addition, the predicted minimum film thickness is 50 mm at a rotating speed of 5,000 rpm. These results indicate that there is no issue in the thermal behavior of the bearing. An operation test is performed with a power turbine module consisting of a power turbine, a reduction gear and a generator. Thermocouples are installed at the 75% position from the leading edge of the pad to monitor pad temperature. The power turbine uses compressed air at a temperature of $250^{\circ}C$ in its operation. The steady state pad temperatures measured in the test show good agreement with the predicted temperatures.

8kW급 디젤발전기 소음기 내부 유동에 관한 수치해석 (Numerical analysis of the Internal Flow of 8kW Grade Diesel Generator Muffler)

  • 이중섭;이태의;이치우
    • 한국기계가공학회지
    • /
    • 제17권3호
    • /
    • pp.45-50
    • /
    • 2018
  • From the flow analysis of the silencer for 8 kW diesel generators, the following results were obtained. For silencer-1, it was confirmed that the holes formed at the inlet-side portion connect into the exhaust pipe in the chamber. The exhaust pipe installed inside silencer-1 was integrally connected through the holes in the chamber. As a result, it was confirmed that the pressure inside the chamber was kept stable. It was confirmed that the pressure loss generated inside an absorptive type silencer such as silencer-2 was small. The differential pressure of the inlet-outlet of silencer-1 and silencer-2 was confirmed to be 494 Pa at 15 m/s, 859 Pa at 20 m/s, 1326 Pa at 25 m/s, and 1911 Pa at 30 m/s.

WSDL 2.0을 이용한 ETSI 표준 M2M 플랫폼과 이종의 웹 애플리케이션 간의 서비스 차원의 통합 방안 연구 (Research on Service-Level Integration of ETSI M2M Platform with Heterogeneous Web Applications based on WSDL 2.0)

  • 박윤정;민덕기
    • 한국정보통신학회논문지
    • /
    • 제17권8호
    • /
    • pp.1842-1850
    • /
    • 2013
  • ETSI 표준 M2M 플랫폼은 M2M을 위한 공통 서비스를 제공하는 플랫폼으로, 본 논문에서는 WSDL 2.0 표준 문서를 이용하여 ETSI 표준 M2M 플랫폼 서비스를 SOAP, HTTP 및 CoAP 형태의 웹 서비스로 제공 가능하게 함으로 서비스 차원에서 이종의 웹 애플리케이션과 연동하기 위한 방안을 제시하고 있다. 본 논문에서 제안하는 서비스 차원의 통합 방안은 (1) M2M 플랫폼의 서비스 인터페이스를 WSDL 2.0 문서로 기술하는 단계, (2) 제시된 웹 클라이언트 생성기에 따라 WSDL 2.0 문서를 토대로 SOAP, HTTP 및 CoAP 웹 클라이언트를 생성하는 단계, (3) 제시된 웹 프로토콜 변환기로 웹 서비스 실행 시 이종의 프로토콜을 상호 변환하여 주는 단계를 포함하고 있다.

흉부촬영시 피폭선량과 화질에 관한 조사연구 (The Study on the Image Quality and Patient Exposure Dose of Chest Radiography in Korea)

  • 이선숙;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권2호
    • /
    • pp.49-59
    • /
    • 1995
  • Recently, general radiography became to variety because of the continuous development of Inverter type generator and ortho chromatic system. Therefore, we must re-evaluate about patient exposure dose and image quality. I studied about chest radiography which has frequency among general radiography being used during FEB. to AUG., 1994 over 151 medical facilities from medical facilities that are located in Seoul area. The result obtained were as follows ; 1) The rectification method of the generator were employing mainly single phase full wave in 82.8 %, three phase full wave in 11.26 % and Inverter type in 4.64 % and condenser type is 1.32 %. 2) Exposure kV was used below 80 kV in most medical facilities and 21.8 % of the medical facilities was using high tube voltage higher than 120 kV. 3) The exposure time was used below the 0.05 sec in 28.4 %, in 29.8 % of the medical facilities used above 0.1 sec. 4) The usage frequency of the added filter is 15.3 %, and among them compound filter was used only 4 %. 5) Rare earth screen was used in 37.7 %. 6) The average skin entrance dose was 0.25 mSv, the range of dose is $0.05{\sim}0.79\;mSv$ in each medical facilities. 7) The average density of the lung field is 1.76, 0.49 in lung side, 0.30 in mediastinum and 0.37 in heart shadow. Therefore it is required to improve all of these for increasing image quality and reducing patient exposure dose as soon as possible.

  • PDF

반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가 (An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms)

  • 김기철;송근수;김형태;유경훈;신대건;박덕준
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

APR1400 종합진동평가를 위한 배관시스템의 유동유발진동 간이평가 (Screening Method for Flow-induced Vibration of Piping Systems for APR1400 Comprehensive Vibration Assessment Program)

  • 고도영;김동학
    • 한국소음진동공학회논문집
    • /
    • 제25권9호
    • /
    • pp.599-605
    • /
    • 2015
  • U.S. Nuclear Regulatory Commission(NRC), Regulatory Guide(RG) 1.20(Rev.3, 2007년)은 원자로 냉각재계통, 주증기, 주급수 및 복수시스템의 주요 배관 및 기기에 대하여 압력변동 및 진동에 의한 잠재적 유해효과에 대한 평가를 요구한다. 그러나 증기발생기와 연결된 주증기, 주급수 및 복수시스템의 주요 배관 전체에 대하여 상세 해석하는 것은 매우 복잡하여 한계가 있다. 이 논문은 APR1400 원전의 종합진동평가(comprehensive vibration assessment program, CVAP)를 수행하기 위하여 증기발생기에 연결된 2차측 주요 배관의 음향공진과 펌프유발진동을 위한 간이평가 방법에 관한 것이다. 이 논문에서는 이러한 배관시스템의 잠재적 진동 원인이 무엇인지, 음향공진과 펌프유발진동의 가능성을 예방하기 위한 간이평가 방법은 무엇인지를 고찰하고자 한다. 이 논문은 APR1400 원전 증기발생기와 연결된 주증기 및 주급수 배관의 유동유발진동 간이평가를 위해 사용될 것으로 판단된다.

CO2 흡수용 20Nm3/hr급 Vortex tube의 에너지 분리 현상에 관한 해석적 연구 (Computational Study on the Energy Separation of the Vortex Tube for CO2 Reduction)

  • 김창수;정영철;한근희;박성영
    • 한국산학기술학회논문지
    • /
    • 제10권4호
    • /
    • pp.695-701
    • /
    • 2009
  • 고압의 가스를 이용하여 고온 가스와 저온 가스를 분리하거나 입자상 물질의 분리에 사용 할 수 있는 장치인 볼텍스 튜브의 에너지 분리 특성을 적용하여 $CO_2$ 흡수를 위한 장치설계의 기본 설계 자료를 구축하기 위하여 전산유체 해석을 수행하였다. 설계를 위한 기초 자료를 확보하기 위하여, 볼텍스 튜브의 길이, 볼텍스 발생기의 오리피스 직경 및 고온 측과 저온 측의 유량비등이 볼텍스 튜브의 성능에 미치는 영향을 분석하였다. 튜브의 길이가 길어짐에 따라 고온 출구측의 온도는 감소하지만, 저온 출구측의 온도에 미치는 영향은 미미하였다. 볼텍스 발생기의 오리피스 직경이 축소됨에 따라 저온측 온도는 강하하나 고온측 온도의 변화는 미미하였다. 고온 유량비가 증가함에 따라 고온 출구 쪽의 온도가 강하하였다. 본 연구의 결과는 $CO_2$ 흡수 장치의 기본 설계 자료로 응용될 수 있을 것이다.

100마력 고온초전도 모터 제작과 평가(I) (Fabrication and test of 100 hp High Tc Superconducting Motor)

  • 손명환;백승규;이언용;권영길;권운식;문태선;박희주;김영춘;조창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1118-1120
    • /
    • 2004
  • For the first time in Korea, a 100hp high Tc superconducting(HTS) motor has been designed, developed and successfully tested recently. The design was based on 2-dimensional electromagnetic field analysis of cylindrical coordinate. The field winding of rotor was wound with Bi-2223 tapes and tested after assembled with other rotor components. The stator had air-gap type armature windings which allow higher terminal voltage and more sinusoidal voltage waveform than conventional iron cored machines. Steady state open & short-circuit test and resistive load test were conducted also in generator mode. The fabrication and test results of this machine were discussed in this paper.

  • PDF

수력 원통형 터빈 가이드 베어링의 저부하/저편심 성능향상 설계 - 패드 선단 테이퍼의 도입 (Low-Load/Low-Eccentricity Performance Improvement Designs for Hydro Power Application of Cylindrical Turbine Guide Bearings - Introduction of Pad Leading-Edge Tapers)

  • 이안성;장선용
    • Tribology and Lubricants
    • /
    • 제33권2호
    • /
    • pp.65-70
    • /
    • 2017
  • In vertical hydro/hydraulic power turbine-generator applications, traditionally, cylindrical turbine guide bearings (TGBs) are widely used to provide turbine runner shafts with smooth rotation guides and supports. All existing cylindrical TGBs with simple plain pads have drawbacks such as having no pressure generation and film stiffness at the no-load condition and in addition, at the low-load/low-eccentricity condition, having very low film stiffness values and lacking design credibility in the stiffness values themselves. In this paper, in order to fundamentally improve the low-load/low-eccentricity performance of conventional cylindrical TGBs and thus enhance their design-application availability and usefulness, we propose to introduce a rotation-directional leading-edge taper to each partitioned pad, i.e., a pad leading-edge taper. We perform a design analysis of lubrication performance on $4-Pad{\times}4-Row$ cylindrical TGBs to verify an engineering/technical usefulness of the proposed pad leading-edge taper. Analysis results show that by introducing the leading-edge taper to each pad of the cylindrical TGB one can expect a constant high average direct stiffness with a high degree of design credibility, regardless of load value, even at the low-load/low-eccentricity condition and also control the average direct stiffness value by exploring the taper height as a design parameter. Therefore, we conclude that the proposed pad leading-edge tapers are greatly effective in more accurately predicting and controlling rotordynamic characteristics of vertical hydro-power turbine-generator rotor-bearing systems to which cylindrical TGBs are applied.