• Title/Summary/Keyword: $CO_2$ generator

Search Result 215, Processing Time 0.029 seconds

Carbon Emission Analysis Considering Demand Response Effect in TOU Program (TOU 프로그램의 DR 효과를 고려한 탄소 배출 분석)

  • Kim, Young-Hyun;Kwag, Hyung-Geun;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1091-1096
    • /
    • 2011
  • Currently, the concern about the environment is the issue all over the world, and in particular, carbon emissions of the power plants will not be able to disregard from the respect of generation cost. This paper proposes DR (demand response) as a method of reducing carbon emissions and therefore, carbon emissions cost. There are a number of studies considering DR, and in this paper, the effect of DR is focused on the side of carbon emission reduction effect considering Time-Of-Use (TOU) program, which is one of the most important economic methods in DSM. Demand-price elasticity matrix is used in this paper to model and analyze DR effect. Carbon emissions is calculated by using the carbon emission coefficient provided by IPCC (Intergovernmental Panel on Climate Change), and generator's input-output characteristic coefficients are also used to estimate carbon emission cost as well as the amount of carbon emissions. Case study is conducted on the RBTS IEEE with six buses. For the TOU program, it is assumed that parameters of time period partition consist of three time periods (peak, flat, off-peak time period).

Field study of 5kW class PEMFC system (5kW급 고분자전해질 연료전지 시스템 실증연구)

  • Lee, SooJae;Choi, Dae Hyun;Jun, HeeKwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • The residential Fuel Cell system has high efficiency of 85% with transferring natural gas to electrical power and heat, directly and it is a friendly environmental new technology in that $CO_2$ emission can reduce 40% compared with conventional power generator and boiler. The residential fuel cell system consists of two main parts which have electrical and hot storage units. The electrical unit contains a fuel processor, a stack, an inverter, a control unit and balance of plant(BOP), and the cogeneration unit has heat exchanger, hot water tank, and auxiliaries. 5kW class fuel process was developed and tested from 2009, it was evaluated for long-term durability and reliability test including with improvement in optimal operation logic. Stack development was crried out through improvement of design and evaluation protocol. Development of system controller was successfully accomplished through strenuous efforts and original control logic was optimized in 5kW class PEMFC system. In addition, we have been focused on development of system process and assembly technology, which bring about excellent improvement of reliability of system. The 5kW class PEMFC system was operated under dynamic conditions for 1,000 hours and it showed a good performance of total efficiency and durability.

  • PDF

Recent Insights from the International Common-Cause Failure Data Exchange Project

  • Kreuser, Albert;Johanson, Gunnar
    • Nuclear Engineering and Technology
    • /
    • v.49 no.2
    • /
    • pp.327-334
    • /
    • 2017
  • Common-cause failure (CCF) events can significantly impact the availability of safety systems of nuclear power plants. For this reason, the International Common Cause Data Exchange (ICDE) project was initiated by several countries in 1994. Since 1997 it has been operated within the Organisation for Economic Co-operation and Development (OECD)/Nuclear Energy Agency (NEA) framework and has successfully been operated over six consecutive terms (the current term being 2015-2017). The ICDE project allows multiple countries to collaborate and exchange CCF data to enhance the quality of risk analyses, which include CCF modeling. As CCF events are typically rare, most countries do not experience enough CCF events to perform meaningful analyses. Data combined from several countries, however, have yielded sufficient data for more rigorous analyses. The ICDE project has meanwhile published 11 reports on the collection and analysis of CCF events of specific component types (centrifugal pumps, emergency diesel generators, motor operated valves, safety and relief valves, check valves, circuit breakers, level measurement, control rod drive assemblies, and heat exchangers) and two topical reports. This paper presents recent activities and lessons learnt from the data collection and the results of topical analysis on emergency diesel generator CCF impacting entire exposed population.

An Experimental Study for Drawing of Optimal Process Condition in the SLS Process (SLS 공정에서 최적 공정 조건 도출을 위한 실험적 연구)

  • Bae, Sung-Woo;Yoo, Seong-Yeon;Kim, Dong-Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.516-524
    • /
    • 2012
  • Selective Laser Sintering(SLS) system consists of various element technologies. Main components of the system include a position control system, a speed control system of the roller, and nitrogen atmosphere furtherance for the powdered sintering. Other systems which make the core of the SLS system are build room and the feed room for powder epitaxial, a temperature control system, and a scan path generator for the laser. The powder material for laser sintering is necessary to produce prototypes in Solid Freeform Fabrication(SFF) based on SLS process. This powder material is sintered in powder room using $CO_2$ laser after spreading evenly using roller to reproduce mold via SFF. This study addresses an SFF system by using the SLS process which applies single laser system to enable manufacturing of 3D shape. And to evaluate applicability of the single laser system, experiments were conducted with optimal fabricating process.

Testing a Commercial Gas Engine using Synthetic Biogas (합성 바이오가스를 이용한 상용 가스엔진 발전기의 구동 특성)

  • Shim, Jae-Hoon;Hong, Seong-Gu;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.592-597
    • /
    • 2005
  • Biogas is widely accepted as one of renewable energy. Raw biogas can be used in internal combustion engines either spark ignition or diesel engines. Since the gas has relatively low calorific values, engine power also is lower than rated power values. Modified engines or biogas-specific engines have been utilized in order to increase efficiency. Recently, gas engine/generators are provided for various purposes. They are mostly for LPG or natural gas. When biogas is fueled to the gas engines, de-rating is inevitable due to its lower calorific values. Meanwhile, massively produced commercial gas engines are more competitive in terms of initial investment for engines, compared to biogas-specific engines. Then, the characteristics of the commercial engine and power generation should be understood for better operation. A 5kW gas engine/generator(natural gas) was tested for determining an allowable maximum concentration of $CO_2$ in synthetic biogas, with respect to engine stating, power generation. Experimental results indicated that about 65% of methane concentration is required to start the gas engine. At this condition, the power generated was about 3 kW. It is about 60% of the nominal power, which is similar to the ratio of calorific values.

  • PDF

The Study of Effect of Steam on Partial Oxidation for Model Biogas using 3D Matrix Reformer (3D 매트릭스 개질기를 활용한 모사 바이오가스 부분산화 및 수증기 영향 연구)

  • Lim, Mun-Sup;Chun, Young-Nam
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.772-779
    • /
    • 2011
  • New type of syngas generator based on the partial oxidation of biogas in volumetric permeable matrix reformers was suggested as an effective, adaptable and relatively simple way of syngas and hydrogen production for various low-scale applications. The use of biogas as an energy source reduces the chance of possible emission of two greenhouse gases, $CH_4$ and $CO_2$, into the atmosphere at the same time. Its nature of being a reproducible energy source makes its use even more attractive. Parametric screening studies were achieved as air ratio, biogas component ratio, input gas temperature, Steam/Carbon ratio. As the air ratio was low, the production of the hydrogen and carbon monoxide increased in the condition that 3D matrix reformer maintains the stable driving. As it was the simulation biogas in which the carbon dioxide content is high, the flammable range became narrow. And the flammable range was extended if the injected gas was preheated. The stable driving was possible in the low air ratio. The amount of hydrogen production was increased as S/C ratio increased.

Development of a Moving Body Type Wave Power Generator using Wave Horizontal Motions and Hydraulic Experiment for Electric Power Production (파의 수평운동을 이용한 가동물체형 파력발전장치의 개발과 전력생산에 관한 수리실험)

  • Hwang, Seong Su;Lee, Dong Soo;Yang, Kyong Uk;Byun, Jung Hwan;Park, Il Heum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.2
    • /
    • pp.73-80
    • /
    • 2016
  • To reduce the mechanical energy loss and to get the high energy efficiency, an apparatus of wave power generation inducing a consistent one way rotating motion from the wave reciprocation motions was developed and the hydraulic experiments for the real electric power production were conducted and the results were discussed. In the experiments for the shape of the buoyant tank, the efficiency of the fixed 9 cm diameter type enduring the wave plate weight was 14.6% and this was the best result for all shapes. But although the free sliding type was expected to represent a high efficiency, the experiments did not show a good result as 8.5% efficiency. Therefore, the shape of buoyant tank was decided as the fixed 9 cm diameter type in the next all tests. In the experiments for the various incident waves, when the water depth was 90 cm, the average efficiencies were measured as 3.9% in the 2nd gear, 4.9% in the 3rd gear, 4.9% in the 4th gear, 12.0% in the 5th gear, 10.0% in the 6th gear, 3.1% in the 7th gear, and 3.0% in the 8th gear. Also, when the water depth was 80 cm, the average efficiency was shown as 15.0% with 5th gear condition. Therefore the high average efficiency as 13.5% was given with 80~90 cm water depth and the 5th gear in the model.

Effect on Quality Change of Cherry Tomato by $CO_2$ Concentration of Flushed Gas and Storage Period (충전가스의 $CO_2$ 함량 및 노출기간의 변화가 방울토마토의 품질변화에 미치는 영향)

  • Lee, Seung Yuan;Lee, Seung Jae;Choi, Dong Soo;Hur, Sun Jin
    • Culinary science and hospitality research
    • /
    • v.20 no.6
    • /
    • pp.200-210
    • /
    • 2014
  • The purpose of this study was to investigate the quality changes and contamination of microorganisms such as Escherichia coli, mold and yeast in cherry tomatoes during storage at different temperatures, gas composition and periods(7 and 14 days). This study determined pH, color change and the growth pattern of microorganisms in cherry tomato during storage at $5^{\circ}C$, $10^{\circ}C$ and $15^{\circ}C$. According to the results, pH level was a little raised with storage period. On average, $L^*$, $a^*$ and $b^*$ value of cherry tomato were irregular value of increase and decrease of all gas packaging with storage period. In regard of the types of microorganism, aerobic count plate, coliform count, mold and yeast were detected when cherry tomatoes were stored at $5^{\circ}C$, $10^{\circ}C$ and $15^{\circ}C$ during storage for 14 days. Equally, all microorganisms of cherry tomato were irregular with storage period and complex gas packaging. However, this study determined that packaging with a higher $CO_2$ concentration than $O_2$ concentration can reduce growth of microorganism. These studies can be used as primary data for determining the optimal complex gas to storage enlargement.

Reduction and Decomposition of Hazardous NOx by Discharge Plasma with $TiO_2$ ($TiO_2$ 촉매를 이용한 플라즈마반응에 의한 NOx의 분해)

  • Park, Sung-Gug;Woo, In-Sung;Hwang, Myung-Whan
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.54-60
    • /
    • 2008
  • The objective of this study is to obtain the optimal process condition and the maximum decomposition efficiency by measuring the decomposition efficiency, electricity consumption, and voltage in accordance with the change of the process variables such as the frequency, maintaining time period, concentration, electrode material, thickness of the electrode, the number of windings of the electrode, and added materials etc. of the harmful atmospheric contamination gases such as NO, $NO_2$, and $SO_2$ etc. with the plasma which is generated by the discharging of the specially designed and manufactured $TiO_2$ catalysis reactor and SPCP reactor. The decomposition efficiency of the NO, the standard samples, is obtained with the plasma which is being generated by the discharge of the combination effect of the $TiO_2$ catalysis reactor and SPCP reactor with the variation of those process variables such as the frequency of the high voltage generator($5{\sim}50kHz$), maintaining time of the harmful gases($1{\sim}10.5sec$), initial concentration($100{\sim}1,000ppm$), the material of the electrode(W, Cu, Al), the thickness of the electrode(1, 2, 3mm), the number of the windings of the electrode(7, 9, 11turns), basic gases($N_2$, $O_2$, air), and the simulated gas($CO_2$) and the resulting substances are analyzed by utilizing FT-IR & GC.

Improvement of Water Quality by Corona Discharge Plasma-activated Water in a Tilapia Recirculating Aquaculture System (코로나 방전-플라즈마 처리수의 틸라피아 순환여과양식시스템 수질 개선 효과)

  • You, Jin Ho;Mun, Seong Hee;Oh, Hyeon Ji;Park, Tae Sup;Kwon, Joon Yeong
    • Journal of Marine Life Science
    • /
    • v.5 no.2
    • /
    • pp.51-57
    • /
    • 2020
  • Disinfection and maintenance of rearing water in aquaculture is an essential element for the prevention of fish diseases. This is especially important in recirculating aquaculture systems (RAS) in which fish are reared at high density using recycled water. In this study, tilapia was reared in two different RAS (one with plasma generator - PW system, another without plasma generator - No PW system). In plasma treated group, UVT% of water was improved clearly, and the number of heterotrophic bacteria decreased significantly after 40 days. Total weight gain of tilapia in PW system was significantly higher, and other growth indicators were also relatively higher although not statistically significant. In addition, the fish in PW system had a 100% survival rate, and there were no histological differences between fish from both systems. Fish did not seem to be affected by the toxicity of ROS. In conclusion, it is expected that plasma water can effectively deactivate fish pathogens and improve the quality of rearing water.