This study evaluates three distinct observation methods, CRDS, OA-ICOS, and OF-CEAS, in greenhouse gas monitoring equipment for atmospheric CO2 and CH4 concentrations. The assessment encompasses fundamental performance, high-concentration measurement accuracy, calibration methods, and the impact of atmospheric humidity on measurement accuracy. Results indicate that within a range of approximately 500 ppm, all three devices demonstrate high accuracy and linearity. However, beyond 1000 ppm, CO2 accuracy sharply declines (84%), emphasizing the need for caution when interpreting high-concentration CO2 data. An analysis of calibration methods reveals that both CO2 and CH4 measurements achieve high accuracy and linearity through 1-point calibration, suggesting that multi-point calibration is not imperative for precision. In dynamic atmospheric conditions with significant CO2 and CH4 concentration variations, a 1-point calibration suffices for reliable data (99% accuracy). The evaluation of humidity impact demonstrates that humidity removal devices significantly reduce air moisture levels, yet this has a negligible effect on dry CO2 concentrations (less than 0.5% relative error). All three observation method instruments, which have integrated humidity correction to calculate dry CO2 concentrations, exhibit minor sensitivity to humidity removal devices, implying that additional removal devices may not be essential. Consequently, this study offers valuable insights for comparing data from different measurement devices and provides crucial information to consider in the operation of monitoring sites.
비식용 바이오매스로부터 합성액체연료를 생산하기 위해 바이오매스 가스화와 Fisher-Tropsch (FT) 반응을 연계하는 바이오매스 액화(BTL) 공정이 개발되고 있다. 그러나 바이오매스 가스화 내에 포함되어 있는 $H_2S$, COS 및 $CO_2$는 FT 반응의 효율을 저하시키고 촉매를 피독시키는 원인이 된다. 따라서 본 연구에서는 합성가스 내에 포함된 산성가스들의 제거를 위해 lab-scale 메탄올 흡수탑을 제작하여 산성가스 제거 특성을 고찰하였다. 메탄올 흡수탑 내의 온도, 압력, 메탄올 사용량 및 산성가스 농도에 따른 제거 성능의 영향을 고찰하였다. 메탄올 흡수탑은 $H_2S$, COS의 제거와 동시에 이산화탄소를 효율적으로 제거하여 바이오매스 액화 공정에 효율적으로 이용할 수 있음을 확인하였다.
연구목적: 본 연구는 플랜트 시설물의 피난 안전성을 확보하기 위해 제연경계벽의 폭 및 제연설비의 유무와 피난 안전성과의 관계를 분석하고자 한다. 연구방법: 화재 및 피난 시뮬레이션을 활용하여 제연경계 벽의 폭, 수직거리에 따른 급기량, 배기량의 변화를 통해 피난 안전성을 분석 하였다. 연구결과: 가시도의 경우 경계벽 0.6m 만을 사용한 경우 5m 이하로 되는 시점이 가장 짧게 도달하였으며 제연경계 폭 1.2m와 제연설비를 사용한 경우와 비교하여 20%긴 것으로 나타났다. 온도의 경우 제연설비를 사용하지 않고 경계 폭만 사용하였을 때 0.6m 보다 1.2m가 20% 긴 것으로 확인되었다. 결론: 제연 경계벽에서는 온도를, 제연설비에서는 가시도의 영향을 줄일 수 있으나, 반대로 제연 경계벽의 길이를 길게 하였을 때 가시도의 영향을 줄 수 있으며, 제연설비를 설치하였을 때 온도의 영향을 주는 것으로 나타났다. 따라서, 공정 특성을 고려하여 적합한 제연계획과 제연 설비를 설치해야 할 것으로 판단된다.
가연성 폐기물 가스화반응으로 생성되는 합성가스내의 $CO_2$ 제거반응에서 $Li_2ZrO_3$와 알칼리염 첨가제의 효과를 열중량 분석기를 이용하여 그 특성을 연구하였다. $Li_2ZrO_3$는 고체상태의 $ZrO_2$와 $Li_2CO_3$를 합성하여 제조하였고, 반응성향상을 위하여 $K_2CO_3$, $Na_2CO_3$, NaCl, LiCl 등의 알칼리염을 첨가한 후 열처리하여 사용하였다. 첨가한 알칼리염에 따른 반응성 향상은 $K_2CO_3>NaCl>LiCl>Na_2CO_3$ 순으로 나타났고 이는 $Li_2CO_3$의 partial melting에 기인한 것으로 사료된다. 반응 시료의 SEM 분석 결과 용융상태의 존재를 확인할 수 있었고, XRD를 통해 첨가된 알칼리염들의 화학적 성분 변화는 일어나지 않는 것으로 확인되었다. NaCl을 사용한 경우 반응 초기에 60분 정도의 유도시간이 발생하였으며, $Na_2CO_3$가 첨가된 경우 $700{\sim}750^{\circ}C$에서도 $Li_2ZrO_3$의 $CO_2$ 제거반응에 의해 생성된 $Li_2CO_3$의 분해가 유도되지 않아 반응성 감소현상이 나타나지 않았다.
In this study, we evaluated the treatment efficiency of livestock wastewater by altering the current density using boron-doped diamond (BDD) electrodes. As the current density was adjusted from 10 to 35 mA/cm2, the removal efficiency of organic matter increased from 22.2 to 71.5%. Similar to that of organic matter, the removal efficiency of color increased with increasing current density up to 85.7%, indicating a higher removal efficiency for color than that of organic matter. The removal efficiency of ammonia nitrogen increased from 14.6 to 53.3% as the current density increased, but it was lower than that of organic matter. In addition, the removal of organic matter, color, and ammonia nitrogen followed first-order reactions, according to the reaction rate analysis. The energy consumption ranged from 4.87 to 8.33 kWh/kg COD, and it was found that the organic matter removal efficiency was more efficient at high current densities. Based on various analyses, the optimal current density was 20 mA/cm2, and the corresponding energy consumption was 6.824 kWh/kg COD.
본 연구는 방사성 폐액의 처리를 목적으로 화학처리와 한외여과막의 결합공정에 의해서 Cs과 Co이온의 제거 특성을 조사하였다. 실험은 회분식 UF Stirred Cell을 이용하였고, 화학결합제로서 Cs에 대해서는 시안화철구리화합물, 그리고 Co에 대해서는 Polyacrylic Acid(PAA)를 주입하여 Cs이온과 Co이온의 제거 거동을 조사하였다. Cs의 결합특성은 Langmuir Isotherm형태의 식으로 나타내어 평가하였으며, Cs/K$_2$Cu$_3$(Fe(CN)$_{6}$)$_2$의 몰비가 1.5에서 효율적인 조건임을 알 수 있었다. Co의 제거효율은 용액의 pH, PAA및 Co이온의 몰비에 의해서 결정되었다. Co의 제거거동은 리간드와 Co와의 결합,용액의 pH및 Co농도와의 상호작용에 의한 평형관계식에 의해서 평가하였으며, 이때 90%의 제거율을 얻기 위한 조건은 몰비가 2($\beta$=2)이고 pH가 5.6이었다. 이의 결과로부터 Cs과 Co의 동시제거을 위한 화학첨가제의 주입방법에 대한 제거성능을 평가하였다.
This study evaluated the nitrogen oxide (NOx) removal efficiency by air purification concrete blocks with titanium dioxide (TiO2). The concrete in the mixtures had a 30% water:cement ratio, to which TiO2 was added at 0%, 5%, and 10% of cement weight. The compressive strength reduction rate and removal efficiency of NOx were investigated. The result of the compressive strength test in the study indicated that addition rate of TiO2 did not lead to signifcant effect. In terms of the average removal efficiency of NOx, mix No. 1 using a TiO2 mixing ratio of 0% had a removal efficiency of 0.57% on average; thus, the removal effect w as not significant. For the other samples prepared by mixing, the average removal efficiencies for mix No. 2 (5% TiO2) were 58.86% and 62.05% for normal and washing surface treatments, respectively, and those of sample No. 3 (10% TiO2) were 59.94% and 67.61%. mixs No. 4 (5%) and No. 5 (10%), in which TiO2 diluted with distilled water was sprayed onto the block surface, had an average NOx removal efficiency of 61.72% and 68.48%, respectively. In terms of NOx removal efficiency, Mixs No. 3 and No. 5 with 10% TiO2 were better than Mixs No. 2 and No. 4 with 5% TiO2. In addition, analyzing the NOx removal efficiency results from the fixing method, it was capable to apply mixing (washing) and the diluted spray methods. Therefore, it was found that the diluted spray method applied in this study can be employed in any manufacture of air purification concrete blocks.
본 연구에서는 세라믹 중공사 접촉막 모듈을 이용하여 CH4/CO2 혼합가스에서 CO2 분리 실험을 수행하였다. 높은 성능의 접촉막 모듈을 제작하기 위해 고투과성 중공사막의 제조 실험을 진행하였으며, 제조한 중공사막은 N2 기체투과실험을 통해 투과 성능을 평가하였다. 최종적으로 고투과도 중공사막을 이용하여 CH4/CO2 혼합 기체 분리를 위한 Hollow fiber membrane contactor (HFMC)를 제작하였다. 실험에는 CH4/CO2 혼합 기체(34.5% CO2, CH4 balance)와 monoethanolamine (MEA)를 사용하였으며, CO2 제거 효율이 흡수제의 유량에 따라 어떠한 영향을 받는지 평가하였다. CO2 제거 효율은 액체유량이 증가함에 따라 같이 상승하였으며, CO2 흡수 flux 또한 액체유량과 함께 증가하는 결과를 보였다.
Tetraethyl orthosilicate (TEOS) 혹은 1,2-bis(triethyoxysilyl)ethane (BTSE)과 여러 종류의 organosilane들을 공중합하여 유 무기 혼성 메조포러스 물질들을 제조하고, 이들이 공기 중의 휘발성 유기화합물(VOC)들을 흡착 제거하는 능력을, TEOS 만을 사용하여 제조한 친수성 무기 메조포러스물질인 SBA-15와 비교 평가하였다. 유기 구조의 도입에 의한 소수성의 증대는 메조포러스 물질이 VOC를 흡착 제거하는데 긍정적 효과를 줌을 관찰하였다. 특히 BTSE와 phenyl triethoxysilane을 중량비 90:10으로 공중합한 유 무기 혼성 메조포러스 물질의 VOC 제거 능력은 우수하였다. 또, 물속에 분산된 기름 성분을 흡착 제거하는데 유 무기 혼성 메조포러스 물질들을 유용하게 응용할 수 있음도 정성적으로 관찰하였다.
Among various wet cleaning methods, megasonic and jet spray gained their popularity in single wafer cleaning process for the efficient removal of particulate contaminants from the wafer surface. In the present study, we evaluated these two cleaning methods for particle removal efficiency (PRE) and pattern damage on the aluminum layered wafer surface. Also the effect of $CO_2$ dissolved water in jet spray cleaning is assessed by measuring PRE. It is observed that the jet spray cleaning process is more effective in terms of PRE and pattern damage compared to megasonic cleaning and the mixing of $CO_2$ in the water during jet sprays further increases the PRE. We believe that the outcome of the present study is useful for the semiconductor cleaning process engineers and researchers.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.