• Title/Summary/Keyword: $CO_2$ Absorbent

Search Result 131, Processing Time 0.025 seconds

Preparation of Honeycomb Carbon Dioxide Adsorbent Impregnated $K_2CO_3$ and Its Characterization ($K_2CO_3$를 담지시킨 고체 허니컴 이산화탄소 흡수제의 제조 및 이의 특성 평가)

  • Lee, Dong-Chul;Kim, Jin-Bae;You, Yoon-Jong
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.624-629
    • /
    • 2012
  • To capture and recover carbon dioxide ($CO_2$), we impregnated honeycomb made of ceramic paper with $K_2CO_3$ and its absorption characteristics of $CO_2$ were investigated. The absorption amount of $CO_2$ on the honeycomb absorbent impregnated with $K_2CO_3$ was 13.8 wt% at a constant temperature ($70^{\circ}C$) and relative humidity (66%) condition. Because the absorption amount of $CO_2$ achieved almost the same loading ratio of $K_2CO_3$ (17.6 wt%), the absorption reaction of $CO_2$ by $K_2CO_3$ on the honeycomb absorbent seems to be going smoothly. In addition, $CO_2$ absorption breakthrough characteristics of the honeycomb absorbent were analyzed at the temperature range of $50{\sim}80^{\circ}C$, and the water vapor was fed to an absorption column before the feeding of $CO_2$ or simultaneously with $CO_2$. As a result, the absorption capacity of $CO_2$ was more enhanced using the water vapor supplying before $CO_2$ than that of simultaneous supplying. It was confirmed by temperature programmed desorption analysis that the $KHCO_3$ produced by the absorption reaction of $K_2CO_3$ and $CO_2$ is regenerated by the desorption of $CO_2$ at a temperature of about $128^{\circ}C$.

Hydrodynamic Characteristics of Absorbent and Catalyst for Pre-combustion CO2 Capture (연소 전 이산화탄소 회수를 위한 흡수제 및 촉매의 수력학적 특성)

  • Ryu, Ho-Jung;Yoon, Joo-Young;Lee, Dong-Ho;Shun, Dowon;Park, Jaehyeon;Park, Yeong-Seong
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.437-445
    • /
    • 2013
  • To develop SEWGS (sorption enhanced water gas shift) system using dry $CO_2$ absorbent for pre-combustion $CO_2$ capture, hydrodynamic characteristics of $CO_2$ absorbents were measured and investigated. The minimum fluidization velocity of $CO_2$ absorbent was measured and the effects of the operating conditions were investigated to operate the system at bubbling fluidized bed condition. The minimum fluidization velocity decreased as pressure and temperature increased. Moreover, the minimum fluidization velocity decreased as column diameter increased. The effects of operating conditions on the solid circulation rate were measured and investigated to select appropriate operating conditions for continuous $CO_2$ capture and regeneration. The measured solid circulation rates were ranged between 10 and 65 kg/h and increased as the solid injection velocity, gas velocity in the regeneration reactor, and solid height increased.

Post-combustion CO2 capture with potassium L-lysine (Potassium L-lysine을 이용한 연소 후 이산화탄소 포집)

  • Lim, Jin Ah;Yoon, Yeo Il;Nam, Sung Chan;Jeong, Soon Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4627-4634
    • /
    • 2013
  • Carbon dioxide is one of the main causes of global warming. In order to develop a novel absorbent, the characteristics of amino acid salts solution as a solvent for $CO_2$ capture in continuous process were investigated. The cost of $CO_2$ capture is almost 70% of total cost of CCS (carbon dioxide capture and storage). In the carbon dioxide capture process, process maintenance costs consist of the absorbent including the absorption, regeneration, degradation, and etc. It is very important to study the characteristics of absorbent in continuous process. In this study, we have investigated the properties of potassium L-lysine (PL) for getting scale-up factors in continuous process. To obtain optimum condition for removal efficiency of $CO_2$ in continuous process by varying liquid-gas (L/G) ratio, concentration of $CO_2$ and absorbent (PL) were tested. The stable condition of absorber and regenerator (L/G) ratio is 3.5. In addition, PL system reveals the highest removal efficiency of $CO_2$ with 3.5 of L/G and 10.5 vol% $CO_2$ ($1.5Nm^3/h$).

Reaction Characteristics of WGS Catalyst with Fraction of Catalyst in a Batch Type Fluidized Bed Reactor (회분식 유동층 반응기에서 촉매함량 변화에 따른 WGS 촉매의 반응특성)

  • Ryu, Ho-Jung;Hyun, Ju-Soo;Kim, Ha-Na;Hwang, Taek-Sung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.465-473
    • /
    • 2011
  • To find the optimum mixing ratio of WGS catalyst with $CO_2$ absorbent for SEWGS process, water gas shift reaction tests were carried out in a fluidized bed reactor using commercial WGS catalyst and sand (as a substitute for $CO_2$ absorbent). WGS catalyst content, gas velocity, and steam/CO ratio were considered as experimental variables. CO conversion increased as the catalyst content increased during water gas shift reaction. Variations of the CO conversion with the catalyst content were small at low gas velocity. However, those variations increased at higher gas velocity. Within experimental range of this study, the optimum operating condition(steam/CO ratio=3, gas velocity = 0.03 m/s, catalyst content=10 wt.%) to get high CO conversion and $CO_2$ capture efficiency was confirmed. Moreover, long time water gas shift reaction tests up to 20 hours were carried out for two cases (catalyst content = 10 and 20 wt.%) and we could conclude that the WGS reactivity at those conditions was maintained up to 20 hours.

Hydrogen Generation Characteristics of SMART System with Inherent $CO_2/H_2$ Separation ($CO_2/H_2$ 원천분리 SMART 시스템의 수소생산특성)

  • Ryu, Ho-Jung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.4
    • /
    • pp.382-390
    • /
    • 2007
  • To check the feasibility of SMART(Steam Methane Advanced Reforming Technology) system, an experimental investigation was performed. A fluidized bed reactor of diameter 0.052m was operated cyclically up to 10th cycle, alternating between reforming and regeneration conditions. FCR-4 catalyst was used as the reforming catalyst and calcined limestone(domestic, from Danyang) was used as the $CO_2$ absorbent. Hydrogen concentration of 98.2% on a dry basis was reached at $650^{\circ}C$ for the first cycle. This value is much higher than $H_2$ concentration of 73.6% in the reformer of conventional SMR (steam methane reforming) condition. The hydrogen concentration decreased because the $CO_2$ capture capacity decreased as the number of cycles increased. However, the average hydrogen concentration at 10th cycle was 82.5% and this value is also higher than that of SMR. Based on these results, we could conclude that the SMART system can replace SMR system to generate pure hydrogen without HTS (high tempeature shift), LTS (low temperature shift) and $CO_2$ separation process.

Determination and Calculation of Physical Properties for Sodium Glycinate as a CO2 Absorbent (CO2 제거용 흡착제 Sodium Glycinate의 물성측정과 추산)

  • Park, So-Jin;Jang, Gyeong-Ryong;Park, In Hwan
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.277-283
    • /
    • 2006
  • Aqueous solution of sodium glycinate was checked as a suitable $CO_2$ absorbent from the flu gas in the thermal power plant. For this purpose, solubility, vapor pressure, latent heat of vaporization and thermal conductivity were determined for pure and aqueous solution of sodium glycinate. The solubility of sodium glycinate in the solvent, 25 g of $H_2O$, was increased with increasing the temperature and their relation was represented as a first order equation of y = 0.3471x + 20.993. The vapor pressure for 10 wt% to 60 wt% of aqueous sodium glycinate solution were determined and the latent heat of vaporization of each aqueous solution was calculated from measured vapor pressure using Clausius-Clapeyron equation. Besides, thermal conductivity of sodium glycinate powder was also determined and it was $1.0933kcal/m{\cdot}hr{\cdot}^{\circ}C$.

Degradation Characteristics of Carbon Dioxide Absorbents with Different Chemical Structures (상이한 화학적 구조를 가진 이산화탄소 흡수제의 열화특성)

  • Kim, Jun-Han;Lee, Ji-Hyun;Jang, Kyung-Ryong;Shim, Jae-Goo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.883-892
    • /
    • 2009
  • We evaluated the degradation properties of various alkanolamine absorbents (MEA, AMP, DEA, and MDEA) having different chemical structures for $CO_2$ capture. The degradation of $CO_2$ absorbent in general was known to be caused by oxygen which is in flue gas and by heat source, respectively. To analyze the effect of $CO_2$ and $O_2$ on degree of degradation, we conducted a variety of experiments at $30^{\circ}C$ and $60^{\circ}C$ (oxidative degradation) and $130^{\circ}C$ and $150^{\circ}C$ (thermal degradation), respectively. DEA showed the worst property for oxidative degradation in the presence of oxygen among the alkanolamine absorbents. In the case of thermal degradation, the degradation of absorbent was occurred for most of absorbents at $150^{\circ}C$. Among these absorbents, MEA and DEA gave the worst results. As a result, AMP which is a primary amine and having a steric hindrance showed the best result through the degradation test. But, the degradation of absorbent proceeded easily in the case of DEA which is a secondary amine and having 2 OH groups in terminal position. Consequently, we have evaluated the degree of degradation of various absorbents having different chemical structures to give the basic data for the development of alkanolamine absorbent.

A Study on Carbon Dioxide Capture Performance of KOH Aqueous Solution via Chemical Absorption (화학 흡수를 이용한 KOH 수용액의 이산화탄소 포집 성능에 관한 연구)

  • Yoo, Mi-Ran;Han, Sang-Jun;Shin, Ji-Yoon;Wee, Jung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.1
    • /
    • pp.55-62
    • /
    • 2012
  • The present paper investigates the performance of the KOH aqueous solution as an absorbent to capture carbon dioxide ($CO_2$). The chemical absorption was carried out according to consecutive reactions that are generated in the order of $K_2CO_3$ and $KHCO_3$. The overall absorption was completed with following the physical absorption. When the absorption was conducted with the KOH as the limiting reactants in batch a reactor, $K_2CO_3$ production rate was the 1st order reaction for $OH^-$. However, $KHCO_3$ generation reaction was independent of the $CO_3^{2-}$ concentration and the rate was calculated to be $0.18gCO_2/min$ for all KOH absorbents, which is the same value of the reaction rate using $K_2CO_3$ aqueous solution as the absorbents. The overall $CO_2$ capture ratio of the 5% KOH absorbent was estimated to be 19% and the individual value in section 1 and 2 was 57 and 12%, respectively. The amount of $CO_2$ absorbed in the solution was very slightly less than the theoretical value, which was ascribed to the side reaction that produces $K_2CO_3{\cdot}KHCO_3{\cdot}1.5H_2O$ during the reaction and the consequent diminish in $CO_2$ absorption in the KOH solution.

Development of High-Durability Ceramic Hollow Fiber and Performance Evaluation of Contact Membrane Process according to Pressure Conditions (고내구성 세라믹 중공사 개발과 압력 조건에 따른 접촉막 공정의 특성 평가)

  • Lee, Seung Hwan;Jeong, Byeong Jun;Shin, Min Chang;Zhuang, Xuelong;Jung, Jiwon;Lee, Yeon Jun;Won, Dongyeon;Park, Jung Hoon
    • Membrane Journal
    • /
    • v.30 no.6
    • /
    • pp.443-449
    • /
    • 2020
  • In this study, CO2 separation experiment was performed on a CH4/CO2 mixed gas using a ceramic hollow fiber membrane contactor module (HFMC). In order to fabricate high-durability HFMC, a high-durability hollow fiber membrane was prepared and evaluated. HFMC was fabricated using the prepared hollow fiber membrane, and the experiment used a mixture of CH4/CO2 (30% CO2, CH4 balance) and monoethanolamine (MEA). During HFMC operation, the effect of gas and absorbent pressure on the CO2 removal efficiency was evaluated. The CO2 removal efficiency increased as the gas pressure increased, and the CO2 absorption flux also showed a tendency to increase with the liquid flow rate. In addition, when the CO2 absorption rate was less than 40%, LTS-1, a counter-current form where the absorbent enters from the bottom, has higher CO2 removal performance than LTS-2, a countercurrent form in which the absorbent enters from the top. and when the absorption rate was 40% or higher, LTS-2 had higher performance than LTS-1.

A Study on CO2 Removal by Chemical Absorption Using Structured Packing (규칙충전물을 적용한 화학흡수법에 의한 이산화탄소 제거에 관한 연구)

  • K?m, Jae-Hong;K?m, Hyoung-Ho;Kim, Jang-ho
    • Clean Technology
    • /
    • v.9 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • As a result of study on factor affecting absorption efficiency using the structured packing, Mellapak N. 250Y for the chemical absorption of $CO_2$ that cause global warming due to development of industry, it is shown that Mellapak N. 250Y has lower pressure drop and superior efficiency of mass transfer than 25mm Pall ring. Also, in the absorption process, it produces high efficiency in the increase of load and concentration of absorption liquid and produces low efficiency in the increase of temperature. In the effect of overall mass transfer coefficient for 15% MEA on the temperature variation of absorbent, when absorbent temperature for 15% MEA varied as 25, 50, $80^{\circ}C$, overall mass transfer coefficients were shown as 0.83, 1.00, $0.90kmol/m^3-h-kPa$.

  • PDF