• 제목/요약/키워드: $AFM_1$

검색결과 982건 처리시간 0.024초

원자힘 현미경을 이용한 이온 주입된 4H-SiC 상의 국소 산화 특성 (Local Oxidation Characteristics on Implanted 4H-SiC by Atomic Force Microscopy)

  • 이정호;안정준;구상모
    • 한국전기전자재료학회논문지
    • /
    • 제25권4호
    • /
    • pp.294-297
    • /
    • 2012
  • In this work, local oxidation behavior in phosphorous ion-implanted 4H-SiC has been investigated by using atomic force microscopy (AFM). The AFM-local oxidation (AFM-LO) has been performed on the implanted samples, with and without activation anneal, using an applied bias (~25 V). It has been clearly shown that the post-implantation annealing process at $1,650^{\circ}C$ has a great impact on the local oxidation rate by electrically activating the dopants and by modulating the surface roughness. In addition, the composition of resulting oxides changes depending on the doping level of SiC surfaces.

공초점현미경과 원자현미경을 이용한 초정밀 가공된 시료 표면의 영상측정 (Analysis of a micro-processed sample surface using SCM and AFM)

  • 김종배;배한성;김경호;남기중;권남익
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.577-580
    • /
    • 2005
  • Surface quality of a micro-processed sample with laser has been investigated by using of scanning confocal microscope(SCM) and atomic force microscope(AFM). Samples are bump electrodes and ITO glass of LCD module used in a mobile phone and a wafer surface scribed by UV laser. A image of $140\times120{\mu}m^2$ is obtained within 1 second by SCM because scan speed of a x-axis and y-axis are 1kHz and 1Hz, respectively. AFM is able to measure correctly hight and width of ITO and scribing depth and width of a wafer with a resolution less than 300 . However, the scan speed is slow and it is difficult to distinguish a surface composed of different nm kinds of materials. Results show that SCM is preferable to obtain a image of a sample composed of different kinds of material than AFM because the intensity of a reflected light from surface is different from each material.

  • PDF

공초점현미경과 원자현미경을 이용한 가공된 시료 표면의 형상측정 (Analysis of a processed sample surface using SCM and AFM)

  • 배한성;김경호;문성욱;남기중;권남익;김종배
    • 한국정밀공학회지
    • /
    • 제23권4호
    • /
    • pp.52-59
    • /
    • 2006
  • Surface qualities of a micro-processed sample with a pulse laser have been investigated by making use of scanning confocal microscope(SCM) and atomic force microscope(AFM). Samples are bump electrodes and ITO glass of LCD module used in a mobile phone and a wafer surface scribed by UV laser. A image of $140{\times}120{\mu}m^2$ is obtained within 1 second by SCM because scan speed of a x-axis and y-axis are 1kHz and 1Hz, respectively. AFM is able to correctly measure the hight and width of ITO, and scribing depth and width of a wafer with a resolution less than 300nm. However, the scan speed is slow and it is difficult to distinguish a surface composed of different kinds of materials. Results show that SCM is preferable to obtain a image of a sample composed of different kinds of material than AFM because the intensity of a reflected light from the surface is different for each material.

Automated measurement and analysis of sidewall roughness using three-dimensional atomic force microscopy

  • Su‑Been Yoo;Seong‑Hun Yun;Ah‑Jin Jo;Sang‑Joon Cho;Haneol Cho;Jun‑Ho Lee;Byoung‑Woon Ahn
    • Applied Microscopy
    • /
    • 제52권
    • /
    • pp.1.1-1.8
    • /
    • 2022
  • As semiconductor device architecture develops, from planar field-effect transistors (FET) to FinFET and gate-all-around (GAA), there is an increased need to measure 3D structure sidewalls precisely. Here, we present a 3-Dimensional Atomic Force Microscope (3D-AFM), a powerful 3D metrology tool to measure the sidewall roughness (SWR) of vertical and undercut structures. First, we measured three different dies repeatedly to calculate reproducibility in die level. Reproducible results were derived with a relative standard deviation under 2%. Second, we measured 13 different dies, including the center and edge of the wafer, to analyze SWR distribution in wafer level and reliable results were measured. All analysis was performed using a novel algorithm, including auto fattening, sidewall detection, and SWR calculation. In addition, SWR automatic analysis software was implemented to reduce analysis time and to provide standard analysis. The results suggest that our 3D-AFM, based on the tilted Z scanner, will enable an advanced methodology for automated 3D measurement and analysis.

가공면미세결함의 나노 인프로세스 측정을 위한 AFM시스템의 개발 (Development of an AFM-Based System for Nano In-Process Measurement of Defects on Machined Surfaces)

  • 권현규;최성대;박무훈
    • 대한기계학회논문집A
    • /
    • 제26권3호
    • /
    • pp.537-543
    • /
    • 2002
  • This paper examines a new in-process measurement system for the measurement of micro-defects on the surfaces of brittle materials by using the AFM (Atomic Force Microscopy). A new AFM scanning stage that can also perform nano-scale bending of the sample was developed by adding a bending unit to a commercially available AFM scanner. The bending unit consists of a PZT actuator and sample holder, and can perform static and cyclic three-point bending. The true bending displacement of the bending unit is approximately 1.8mm when 80 volts are applied to the PZT actuator. The frequency response of the bending unit and the stress on the sample were also analyzed, both theoretically and experimentally. Potential surface defects of the sample were successfully detected by this measurement system. It was confirmed that the number of micro-defects on a scratched surface increases when the surface is subjected to a cyclic bending load.

AFM을 이용한 데이터 저장 소자 연구 (A Study of Data Storage Device Utilizing AFM technology)

  • 최정환;박근형
    • 한국전기전자재료학회논문지
    • /
    • 제19권5호
    • /
    • pp.411-416
    • /
    • 2006
  • A new reading technology for the ultra-high density data storage device utilizing AFM technology was proposed and its experimental results were discussed in this paper. For the experiments, an about $2{\mu}m$ thick conductive polymer layer was spin-coated on the heavily doped n-type Si wafer and an about $0.1{\mu}m$ thick PMMA layer was also been spin-coated on it. After then, the $5{\times}5$ memory way was fabricated by making indents on the surface of the wafer with the heated AFM tip, and the data reading was performed by scanning the surface with the tip biased at 10 V and the measuring the current flowing out at the end of the tip. The experimental results clearly showed that the new data reading technology worked superbly. The current measured was about 0.92 pA at the cell with the indent, and it was not only below 0.31 pA at the cell without the indent, but also at the cell where the indent was erased.

Studies of Effects of Current on Exchange-Bias: A Brief Review

  • Bass, J.;Sharma, A.;Wei, Z.;Tsoi, M.
    • Journal of Magnetics
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2008
  • MacDonald and co-workers recently predicted that high current densities could affect the magnetic order of antiferromagnetic (AFM) multilayers, in ways similar to those that occur in ferromagnetic (F) multilayers, and that changes in AFM magnetic order can produce an antiferromagnetic Giant Magnetoresistance (AGMR). Four groups have now studied current-driven effects on exchange bias at F/AFM interfaces. In this paper, we first briefly review the main predictions by MacDonald and co-workers, and then the results of experiments on exchange bias that these predictions stimulated.

지방산 할로겐화물 유기초박막의 외부자극에 의한 거동 (Behaviors of Externally-Stimulated Organic Ultra Thin Films of Fatty Acid Halides)

  • 박근호;이준호;김덕술
    • 한국응용과학기술학회지
    • /
    • 제26권1호
    • /
    • pp.102-108
    • /
    • 2009
  • Behaviors of saturated fatty acid halides (CI4, C16, C18) were measured by LB method when the molecules were stimulated by pressure. The saturated fatty acid halides were deposited on the indium tin oxide(lTO) glass by the LB method. The average organic ultra thin film size and the surface roughness of the fatty acid halides thin films were investigated using AFM. It was found that AFM images show small surface roughness ($2.5{\sim}5.0\;nm$) and the organic ultra thin film size of $2.5{\sim}12\;nm$. Both aggregations and pin-holes were also seen on the AFM images. However we found that the surface roughness. These effects seem to be reasonable to be related to the increase of the organic ultra thin film size of fatty acid halides.

알루미늄 합금 피로 스트라이에이션의 나노 스케일 관찰 (Nano-Scale Observation of Fatigue Striations for Aluminum Alloy)

  • 최성종;권재도
    • 대한기계학회논문집A
    • /
    • 제25권7호
    • /
    • pp.1047-1054
    • /
    • 2001
  • Atomic Force Microscope (AFM) was used to study cross sectional profiles and dimensions of fatigue striations in 2017-T351 aluminum alloy. Their widths(SW) and heights (SH, SH(sub)h, SH(sub)ι) were measured from the cross sectional profiles of three-dimension AFM images. The following results that will be helpful to understand the fatigue crack growth mechanism were obtained. (1) The relation of SH=$\alpha$(SW)(sup)1.2 was obtained. (2) The ratio of the striation height to its width SH/SW, SH(sub)h/SW and SH(sub)ι/SW did not depend on the stress intensity factor range ΔK and the stress ratio R( =P(sub)min/P(sub)max = K(sub)min/K(sub)max). (3) Effect of precipitate on the morphology of striation was changed by the relative dimensional difference between the striation width SW and the precipitates. From these results, the applicability of the AFM to nano-fractography is discussed.