• 제목/요약/키워드: $1^{st}$-order measurement

Search Result 93, Processing Time 0.024 seconds

THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS (타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화)

  • Hwang Yun-Tae;Lee Sung-Bok;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

A Study on the Co-flow Diffusion Flame Temperature Measurement at Various Fuel Flows Rate Using the Rapid Insertion Technique (급속삽입법을 이용한 연료 유량에 따른 동축류 확산화염에서의 온도 측정에 관한 연구)

  • Han Yongtaek;Lee Kihyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.51-59
    • /
    • 2005
  • Co-flow laminar diffusion flames' temperature has been studied experimentally for ethylene$(C_2H_4)$ using a co-flow burner in order to investigate the characteristics of diffusion flame's temperature distribution. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple. The measurement area was divided into three zones. 1st area was expect to created PAH zone, Il nd area was expect to form soot zone, which is known to generate most soot volume fraction, and III rd area was expect to from soot oxidization zone. Also The temperature along the flame y-axis as a fuel quantity was measured. As a results, we have measured temperature neglecting the effect of soot particles attached to the thermocouple junction, which is close to the nozzle and upstream zone has a unstable flow in co-flow diffusion flame and acquires that the flame y-axis temperature has a uniform temperature in the generated soot volume fraction zone(II nd).

Soot Measurement in an Optically Accessible Diesel Engine Using Laser Sheet 1st report : The Development of Optically Accessible Diesel Engine and Photography of 2D Soot Images Using Laser Sheet (레이저시트광을 이용한 가시화 디젤엔진에서의 Soot 계측 제1보 : 가시화 디젤엔진의 제작 및 레이저를 이용한 Soot의 2D 화상촬영)

  • 이명준;박태기;하종률;정성식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.2
    • /
    • pp.64-71
    • /
    • 2000
  • In order to clarify the characteristics of soot formation and oxidation in-cylinder of a diesel engine, it is necessary to diagnose accurately for combustion of in-cylinder. The past techniques for soot measurement have limitations in providing the characteristics of soot in a diesel engine, whereas, laser-based 2D imaging diagnostics have the potential to provide better temporally and spatially resolved measurements of the soot distribution. We rebuilt an optically accessible diesel engine which is similar to the conditions of a conventional engine and tried to measure soot distribution in a cylinder of the diesel engine using laser induced scattering(LIS) and laser induced incandescence(LII). Some results were acquired in this study. LIS and LII signal that show soot distribution of a in-cylinder were taken by ICCD properly. The signal of LIS was intenser than that of LII. Although they have some differences of signal intensity in early combusion period, both of signals show that they are generally similar in late combustion period, after ATDC 50 degree.

  • PDF

Investigation on Freezing in the Freezing Compartment of a Side by Side Refrigerator (양문형 냉장고 냉동실 결빙원인해석 및 최소화 방안)

  • Kim, Y.K.;Jung, H.Y.;Choi, Y.H.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.34-39
    • /
    • 2010
  • A side by side refrigerator is popularly used one among electric home appliances according to the rise of the customer's living standard. But the frost problem in freezing compartment comes out whenever we develop the high quality refrigerator. In this research, internal flow simulation and temperature measurement were carried out by using CFD and T-type thermocouple respectively in order to understand freezing mechanism. It was revealed that the amount of frost beneath the 1st and 2nd shelves is approximately 40% of total frost and the cause of frost generation is due to bad circulation of low speed cold flow. Using this analysis, the shapes of outlets under shelves are modified. So, the amount of frost in this modified model decreases 6% comparing to original one.

What is sensory and consumer science? ('감각·소비자과학'이란?)

  • Lee, Hye-Seong
    • Food Science and Industry
    • /
    • v.52 no.1
    • /
    • pp.2-10
    • /
    • 2019
  • Sensory and consumer science is one of the four core sciences in food science training. In early years, this field of studies are focused on providing food technologists information of sensory attributes of food for quality control and product optimization, and referred as sensory evaluation or sensory science interchangeably. Yet, during the last decades, its scope has been much broadened looking at sensory properties of food not just as product attributes but consumer-perceived properties, emphasizing human experience. Attentions are increased for sensory fundamentals(sensory psychology and physiology) and multidisciplinary integration of theories and measurement methods for improving satisfaction of consumers' sensory experience and promoting healthy eating and wellbeing. The Sensory Evaluation(SE) division of Korean Society of Food Science and Technology(KoSFoST) has recently changed its name to Sensory and Consumer Science(SCS) division in order to address such evolution of the field and sensory professional's role.

Normal Range of Shoulder Motion and Fluoroscopic Analysis of Motion Fraction (정상인의 견관절 운동범위 및 방사선 투시기를 이용한 운동분율측정)

  • Choi Chang-Hyuk;Yun Gi-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.221-229
    • /
    • 1998
  • We measured, with manual goniometer, the active and passive arc of motion of the shoulder in 31 healthy male subjects who were right-hand dominant and who ranged in age from twenty to thirty-one years. Among ten directions through the four motion plane, the range of motion on the dominant side were significantly smaller than those on the non-dominant side in the motion of six directions. We also measured the motion fraction of the glenohumeral and scapulothoracic movement using fluoroscope in 30-degree intervals of arm elevation in the scapular plane. The ratio of glenohumeral to scapulothoracic movement(θGH/θST) was 1.6 for the full range of motion in scapular plane. At the lower angles of abduction, scapulothoracic movement was slight compared with glenohumeral movement. The motion fraction of scapulothoracic joint was increased from 60-degree to 150 degree of arm angle especially between 120 to 150 degree. During arm elevation, scapula was also extended from 42 degrees to 20 degrees tilting as well as internal rotation. The measuring technique of glenohumeral to scapulothoracic movement(θGH/θST) with fluoroscopy could be applied to the simple radiographic measurement at the out-patient clinic in order to identify the pathology and recovery of shoulder motion after treatment.

  • PDF

The Effects of Ultrasound Imaging Visual Feedback During Toe-Spread-Out Exercise in Subjects With Hallux Valgus (엄지발가락가쪽휨증의 발가락벌리기 운동 시 초음파 영상을 이용한 시각적 피드백의 효과)

  • Kang, Sun-young;Choung, Sung-dae;Shim, Jae-hoon
    • Physical Therapy Korea
    • /
    • v.23 no.3
    • /
    • pp.21-28
    • /
    • 2016
  • Background: The toe-spread-out (TSO) exercise has been introduced as a strengthening exercise for the abductor hallucis muscle in subjects with hallux valgus. Visual biofeedback using ultrasound imaging during exercise, may increase the ability to selectively contract the abductor hallucis muscle, compared with exercise alone. Objects: The aim of this study was to investigate the effects of ultrasound imaging visual feedback during the TSO exercise with respect to its influence on the angle of the first metatarsophalangeal joint (1st MPJ) and the cross-sectional area (CSA) of the abductor hallucis muscle in subjects with hallux valgus. Methods: Twenty-five healthy young subjects with a mean average age of 22.5 years, and a standard deviation of 2.3 years, were recruited for this study. Hallux valgus was defined as an angles greater than $15^{\circ}$ angle of 1st MPJ. Goniometric measurement was used to determine the angle of 1st MPJ. In addition, an ultrasound system was used to collect the CSA of the abductor hallucis muscle in each foot. The angle of the 1st MPJ and CSA of the abductor hallucis were measured in three positions; the resting position, during TSO exercise, and during TSO exercise in conjunction with real-time ultrasound imaging feedback. All data analyzed using a repeated analysis of variance with Bonferroni correction in order to compare the dependent variables in all three positions. Statistical level of significance was set up as p<.05. Results: The angle of the 1st MPJ was noted to be significantly reduced and the CSA of the abductor hallucis to be significantly greater during TSO exercise used in conjunction with ultrasound imaging visual feedback, compared to when the values were recorded during TSO exercise alone (p<.05). Conclusion: Based on these findings, it can be concluded that the application of ultrasound imaging visual feedback during TSO exercise is more effective in contracting selectively the abductor hallucis than the use of exercise alone.

A Study on the Evaluation Methods of Residual Flux Cleaning Ability by Alternative Semi-Aqueous Cleaners Using Metal Test Tools After Soldering with Solder Paste (솔더페이스트로 솔더링 후 잔류 플럭스 오염물에 대한 준수계 세정제의 금속치구를 이용한 세정성능 평가방법 연구)

  • Lee, Dong-Kee
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.103-109
    • /
    • 2008
  • In this study, in order to develop evaluation method of the cleaning efficiency of residual flux which remains on the surface after soldering with solder paste, a specially designed metal tool is used to reduce spread uncertainty of flux while soldering. Using this tool, the measurement of cleaning efficiency of flux after soldering for some typical alternative semi-aqueous cleaners and 1,1,1-TCE by weighing method was conducted. As the test result of cleaning efficiency for each cleaner at several different cleaning times, the precision of the data is confirmed to within about 4% relative standard deviation (RSD) range. So, it is considered that this would be a good evaluation method for evaluating the cleaning efficiency of the residual flux which remains after solder paste soldering in the alternative cleaning. The results of this test method shows that the cleaning efficiency of ST 100SX and Neozal 750H in the cleaning of residual flux was better than other semi-aqueous cleaners, but its cleaning efficiency was clearly inferior to 1,1,1-TCE.

  • PDF

Residual Stress Prediction in Multi-layer Butt Weld Using Crack Compliance Method (컴플라이언스법에 의한 다층 맞대기 이음의 잔류응력 추정)

  • Kim, Yooil;Lee, Jang Hyun
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.74-79
    • /
    • 2012
  • It depends on the joint configuration, dimensions and constraints of the joint whether the residual stress at the root of single-sided butt weld is tensile or not. Therefore, recommendation is generally made that high R ratio should be used in the fatigue test of welded joint in order to prevent excessively long life caused by compressive residual stress. In this research, the residual stress profile in butt weld joint was obtained through compliance method, using successive extension of a slot and measurement of the variation of strain during the slot extension. The residual stress profile was firstly assumed to be the linear summation of Legendre polynomials up to 9th order excluding 0th and 1st order. Strain variation on the surface was measured while the slot was being extended by cutting to find out the 8 unknown coefficients of each polynomial term. The cut was made by the electric discharge machine. It was concluded that the residual stress near the surface is positive valued, however, it turned into the negative value as soon as it passed through 2 or 3 mm of the depth.

Measurement of Soil Organic Matter Using Near Infra-Red Reflectance (근적외선 반사도를 이용한 토양 유기물 함량 측정)

  • 조성인;배영민;양희성;최상현
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.475-480
    • /
    • 2001
  • Sensing soil organic matter is crucial for precision farming and environment friendly agriculture. Near infra-red(NIR) was utilized to measure the soil organic matter. Multivariate calibration methods, including stepwise multiple linear regression(MLR), principal components recession(PCR) and partial least squares regression(PLS), were applied to soil spectral reflectance data to predict the organic matter content. The effect of soil particle size and water content was studied. The range of soil organic matter contents was from 0.5 to 11%. Near infrared (NIR) region from 700 to 2,500nm was applied. For uniform soil particle size, result had good correlation (R$\^$2/ = 0.984, standard error of prediction= 0.596). The effect of soil particle size could be eliminated with 1st order derivative of the NIR signal. However. moist soil had a little lower correlation. R$\^$2/ was 0.95 and standard error of prediction was 0.94% using the PLS method. The results showed the possibility of soil organic matter measurement using NIR reflectance on the field.

  • PDF