• 제목/요약/키워드: ${\theta}-P$ curve

검색결과 9건 처리시간 0.023초

악태모형과 측모두부 계측 방사선 사진상 스피만곡 분석에 관한 연구 (A STUDY ON THE ANALYSIS OF THE CURVE OF SPEE ON THE GNATHOLOGICAL CAST AND THE CEPHALOMETRIC RADIOGRAPH)

  • 최아영;김정선;계기성
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.323-335
    • /
    • 1998
  • Clinically, the curve of Spee is widely applied as a determined level of the occlusal curvature when the oral rehabilitation and the reconstruction of the prosthesis is needed at the malalignment dentition due to the missing, extrusion, and the inclination of the teeth. The purpose of this study was to analyze the curve of Spee of the occlusal curvature which influences to the occlusal form and the location three dimensionally, and then was to measure the radius and the degree of curvature of the curve of Spee and also was to investigate the influence to the cuspal inclination according to the change of the inclination of the curve of Spee which was analyzed by AutoCAD R.13 program at the gnathological cast and the cephalometric radiograph. The following results were obtained : 1. The radius of the curve of Spee was the mean of $11.74{\pm}3.64cm$ in the model, $12.75{\pm}4.63cm$ in the radiograph and there was no significant difference statistically between the model and the radiograph(P>0.001). 2. The radius and the degree of curvature of the curve of Spee showed negative correlation(r=-0.80), while the radius and the degree of curvature of the curve of Spee in relation to the length of the curve of Spee did not show correlation. 3. The case of the curve of Spee inclined to the posterior, that is. $Post.M{\theta}$ group showed the mean of $4.73{\pm}3.64$, positive correlation to the P2m, M1mm, M1dm, M2dm, and especially the greatest correlation coefficient to the mesial inclination angle of the mesio-buccal cusp tip of the first molar(r=0.70). 4. The case of the curve of Spee inclined to the anterior, that is, $Ant.M{\theta}$ group showed the mean of $3.28{\pm}3.59$, positive correlation to the P2m, M1mm, and also the greatest correlation coefficient to the mesial inclination angle of the mesio-buccal cusp tip of the first molar(r=0.78

  • PDF

건축용 타워크레인 마스트의 횡방향 지지요소인 월타이 부재력 특성곡선 (Wall Tie Member Force Curve for the Construction Tower Crane)

  • 고광일;오우훈;이은택
    • 한국강구조학회 논문집
    • /
    • 제18권6호
    • /
    • pp.697-706
    • /
    • 2006
  • 타워크레인의 횡방향 지지와 마스트의 횡강성 및 강도를 확보하기 위하여 횡하중 저항요소로서 사용되는 것이 월타이(wall tie)이다. 본 연구에서는 국내에서 가장 많이 사용되고 있는 독일 립헬사의 T형 타워크레인(기종 290HC, 작업반경: 70m, 인양하중: 12tf)을 대상으로 하고 마스트 및 월타이의 사용부재는 H형강보 구조의 구조물을 모델로 선정하여 월타이의 부재력, 월타이의 각도변화 및 각도범위에 따른 부재력의 변화를 분석하여, 실용적이고 안전한 월타이의 각도범위를 제안하여 현장기술자가 최적의 월타이를 배치할 수 있도록 하였다. 본 연구를 통하여 건축용 타워크레인의 훅크양정을 증대시키기 위하여 설치되는 횡방향지지요소인 월타이의 부재력 계산식을 구하고, 이를 프로그래밍하여 마스트 중심과 월타이 브라켓 간 거리를 변화시키면서, 월타이 각도별 월타이 부재력을 반복계산하여 월타이 부재력 특성곡선을 그리고 이를 분석하였다.

비포화 흐름에서 Hysteresis 모델의 비교 연구

  • 박창근;선우중호
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 1991년도 수공학논총 제33권
    • /
    • pp.221-230
    • /
    • 1991
  • Various Models of the moisture content-capillary pressure hysteresie based on the approach of domain concept in porous media are compared with each other, Model III-1(Mualem, 1984) is superio to others as expected. A new model based on Model III-1 is proposed of which asuumption is the linearization of P$$($\theta$) accounting for the pore blockage effect against air-entry. The feature of this model is that only one branch of boundary curve is needed to calibrate it, which is the advantage to Model III-1. The prediction of boundary drying curve from boundary wetting curve using this model is better than that using Model I-1, II-1 compared with the experimental data. This model is to simulate scanning curves, while Model I-1, II-1 is not.

  • PDF

선박용 디젤 엔진의 구조진동에 의한 방사소음 해석 (Radiated Noise Analysis of Marine Diesel Engine from Structural Vibration)

  • 김대환;정의봉;박정근;홍진숙
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.26-34
    • /
    • 2008
  • This paper summarizes a design procedure of radiated noise from engine blocks of marine engines. This air-borne noise is one of the significant noise contributors including the aeroacoustic noise due to intake and exhaust and the re-radiation due to structure-borne noise. Excitation forces by engine operations are evaluated taking into account the power generation mechanism from the burning process to the subsequence motion of internal parts; piston, connecting rod, and crank shaft. The acoustic transfer vector method is incorporated to effectively simulate the radiated noise field under the various operation conditions. A contribution analysis for the various excitations to the radiated noise is conducted. It is found that the firing pressure is the main source of the radiated noise, and so the structure of the cylinder can be modified to significantly reduce the radiated noise from the engine block.

관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석 (ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease)

  • 이경한;최윤호;이범우;문대혁;궁성수;정준기;이명철;고창순
    • 대한핵의학회지
    • /
    • 제23권2호
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF

Application of Quadratic Algebraic Curve for 2D Collision-Free Path Planning and Path Space Construction

  • Namgung, Ihn
    • International Journal of Control, Automation, and Systems
    • /
    • 제2권1호
    • /
    • pp.107-117
    • /
    • 2004
  • A new algorithm for planning a collision-free path based on an algebraic curve as well as the concept of path space is developed. Robot path planning has so far been concerned with generating a single collision-free path connecting two specified points in a given robot workspace with appropriate constraints. In this paper, a novel concept of path space (PS) is introduced. A PS is a set of points that represent a connection between two points in Euclidean metric space. A geometry mapping (GM) for the systematic construction of path space is also developed. A GM based on the 2$^{nd}$ order base curve, specifically Bezier curve of order two is investigated for the construction of PS and for collision-free path planning. The Bezier curve of order two consists of three vertices that are the start, S, the goal, G, and the middle vertex. The middle vertex is used to control the shape of the curve, and the origin of the local coordinate (p, $\theta$) is set at the centre of S and G. The extreme locus of the base curve should cover the entire area of actual workspace (AWS). The area defined by the extreme locus of the path is defined as quadratic workspace (QWS). The interference of the path with obstacles creates images in the PS. The clear areas of the PS that are not mapped by obstacle images identify collision-free paths. Hence, the PS approach converts path planning in Euclidean space into a point selection problem in path space. This also makes it possible to impose additional constraints such as determining the shortest path or the safest path in the search of the collision-free path. The QWS GM algorithm is implemented on various computer systems. Simulations are carried out to measure performance of the algorithm and show the execution time in the range of 0.0008 ~ 0.0014 sec.

Implementation of High Carrier Mobility in Al-N Codoped p-Type ZnO Thin Films Fabricated by Direct Current Magnetron Sputtering with ZnO:Al2O3 Ceramic Target

  • Jin, Hujie;Xu, Bing;Park, Choon-Bae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권4호
    • /
    • pp.169-173
    • /
    • 2011
  • In this study, Al-N codoped p-type zinc oxide (ZnO) thin films were deposited on Si and homo-buffer layer templates in a mixture of $N_2$ and $O_2$ gas with ceramic ZnO:(2 wt% $Al_2O_3$) as a sputtering target using DC- magnetron sputtering. X-ray diffraction spectra of two-theta diffraction showed that all films have a predominant (002) peak of ZnO Wurtzite structure. As the $N_2$ fraction in the mixed $N_2$ and $O_2$ gases increased, field emission secondary electron microscopy revealed that the surface appearance of codoped films on Si varied from smooth to textured structure. The p-type ZnO thin films showed carrier concentration in the range of $1.5{\times}10^{15}-2.93{\times}10^{17}\;cm^{-3}$, resistivity in the range of 131.2-2.864 ${\Omega}cm$, and mobility in the range of $3.99-31.6\;cm^2V^{-1}s^{-1}$ respectively.

Evidence of Spin Reorientation by Mössbauer Analysis

  • Myoung, Bo Ra;Kim, Sam Jin;Kim, Chul Sung
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.126-129
    • /
    • 2014
  • We report the crystallographic and magnetic properties of $Ni_{0.3}Fe_{0.7}Ga_2S_4$ by means of X-ray diffractometer (XRD), a superconducting quantum interference device (SQUID) magnetometer, and a M$\ddot{o}$ssbauer spectroscopy. In particular, $Ni_{0.3}Fe_{0.7}Ga_2S_4$ was studied by M$\ddot{o}$ssbauer analysis for evidence of spin reorientation. The chalcogenide material $Ni_{0.3}Fe_{0.7}Ga_2S_4$ was fabricated by a direct reaction method. XRD analysis confirmed that $Ni_{0.3}Fe_{0.7}Ga_2S_4$ has a 2-dimension (2-D) triangular lattice structure, with space group P-3m1. The M$\ddot{o}$ssbauer spectra of $Ni_{0.3}Fe_{0.7}Ga_2S_4$ at spectra at various temperatures from 4.2 to 300 K showed that the spectrum at 4.2 K has a severely distorted 8-line shape, as spin liquid. Electric quadrupole splitting, $E_Q$ has anomalous two-points of temperature dependence of $E_Q$ curve as freezing temperature, $T_f=11K$, and N$\acute{e}$el temperature, $T_N=26K$. This suggests that there appears to be a slowly-fluctuating "spin gel" state between $T_f$ and $T_N$, caused by non-paramagnetic spin state below $T_N$. This comes from charge re-distribution due to spin-orientation above $T_f$, and $T_N$, due to the changing $E_Q$ at various temperatures. Isomer shift value ($0.7mm/s{\leq}{\delta}{\leq}0.9mm/s$) shows that the charge states are ferrous ($Fe^{2+}$), for all temperature range. The Debye temperature for the octahedral site was found to be ${\Theta}_D=260K$.

오염수계 내 세슘 제거를 위한 대나무 활성탄의 흡착효율 규명 (Sorption Efficiency of the Bamboo Charcoal to Remove the Cesium in the Contaminated Water System)

  • 안정필;이민희
    • 자원환경지질
    • /
    • 제51권2호
    • /
    • pp.87-97
    • /
    • 2018
  • 세슘은 물속에서 고상보다는 이온이나 착염 등 용존 형태로 존재하는 특성이 강하여, 오염 수계로부터 세슘 제거가 어려운 것으로 알려져 있다. 최근 많은 연구들이 수계 내에서 세슘의 제거효율이 높은 흡착제를 개발하는데 집중하고 있다. 본 연구에서는 대나무 활성탄을 흡착제로 사용하여 수계 내에 존재하는 세슘을 효과적으로 제거하는 실내실험을 실시하였다. 수용액으로부터 대나무 활성탄의 세슘 제거효율을 측정하고, 최적의 세슘 제거능을 가지는 흡착 조건을 도출하고자 다양한 조건에서 흡착 배치실험을 수행하였다. 국내에서 유통되고 있는 5 종류의 대나무 활성탄의 표면 특성을 SEM-EDS와 XRD 분석으로 규명하였으며, 이 중에서 비표면적이 큰 3 종류의 대나무 활성탄을 대상으로 세슘 제거 배치실험을 실시하였다. 다양한 초기 세슘 농도를 가지는 인공수(0.01~10 mg/L 범위)를 대상으로 대나무 활성탄에 의한 수용액 내 세슘 제거량을 측정하여 제거효율을 계산하였고, 두 종류의 흡착 등온식들을 흡착 배치실험 결과에 대응시켜 흡착 상수값을 결정함으로서, 대나무 활성탄의 세슘 흡착 특성을 규명하였다. FE-SEM 분석 결과, 대나무 활성탄은 표면이 다수의 기공을 포함하는 대나무의 섬유질 조직을 그대로 유지하는 입자들로 구성되어, 이들 섬유질 조직 내 다양한 형태의 기공들과 엽상조직 표면들이 주요 세슘 흡착공간인 것으로 밝혀졌다. 흡착 배치실험 결과, C type 대나무 활성탄의 세슘 제거효율이 가장 높았는데, 특히 수용액의 세슘 초기 농도가 1.0 mg/L 이하인 경우에도 75 % 이상(최고 82 %)을 나타내어, 원전사고 등에 의해 오염된 현장 지하수나 지표수(해수 포함)의 세슘농도가 대부분 1.0 mg/L 이하임을 고려하면, 실제 오염수 정화 가능성이 높을 것으로 밝혀졌다. 수용액의 온도는 $5-15^{\circ}C$ 범위, pH는 3-11 범위에서 높은 세슘 제거효율이 일정하게 유지되는 것으로 나타나 다양한 오염수에 적용할 수 있을 것으로 판단되었다. 흡착 배치실험 결과는 Langmuir 흡착모델과 유사하였으며, C type 대나무 활성탄의 최대흡착농도($q_m:mg/g$)값은 63.4 mg/g으로 기존의 상용화된 흡착제 값보다 높았고, 수용액의 초기 세슘 농도가 1.0 mg/L이하인 경우 표면흡착률(surface coverage) 값도 낮게 유지되어, 적은 양의 세슘으로 오염된 수계를 효과적으로 정화할 수 있음을 입증하였다.