• Title/Summary/Keyword: $\mu$-TAS

Search Result 37, Processing Time 0.025 seconds

Oxytocin Ameliorates Remote Liver Injury Induced by Renal Ischemia-Reperfusion in Rats

  • Hekimoglu, Askin Tas;Toprak, Gulten;Akkoc, Hasan;Evliyaoglu, Osman;Ozekinci, Selver;Kelle, Ilker
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.17 no.2
    • /
    • pp.169-173
    • /
    • 2013
  • Renal ischemia-reperfusion (IR) causes remote liver damage. Oxytocin has anti-inflammatory and antioxidant effects. The main purpose of this study was to evaluate the protective function of oxytocin (OT) in remote liver damage triggered by renal IR in rats. Twenty four rats were randomly divided into four different groups, each containing 8 rats. The groups were as follows: (1) Sham operated group; (2) Sham operated+OT group (3) Renal IR group; (4) Renal IR+OT group. OT ($500{\mu}g/kg$) was administered subcutaneously 12 and 24 hours before and immediately after ischemia. At the end of experimental procedure, the rats were sacrificed, and liver specimens were taken for histological assessment or determination of malondialdehyde (MDA), total oxidant status (TOS), total antioxidant status (TAS), paraoxonase (PON-1) activity and nitric oxide (NO). The results showed that renal IR injury constituted a notable elevation in MDA, TOS, Oxidative stress index (OSI) and significantly decreased TAS, PON-1 actvity and NO in liver tissue (p<0.05). Additionally renal IR provoked significant augmentation in hepatic microscopic damage scores. However, alterations in these biochemical and histopathological indices due to IR injury were attenuated by OT treatment (p<0.05). These findings show that OT ameliorates remote liver damage triggered by renal ischemia-reperfusion and this preservation involves suppression of inflammation and regulation of oxidant-antioxidant status.

Visualization for the mixing state of a batch-type ultrasonic mixer for its application to the microdevice (마이크로믹서에의 응용을 위한 batch type 초음파믹서의 혼합 상태 가시화)

  • Heo, Pil-Woo;Yoon, Eui-Soo;Koh, Kwang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.47-51
    • /
    • 2005
  • An active ${\mu}$-mixer is important in Bio-MEMS and ${\mu}$-TAS. The mixing state depends on some kinds of factors including the intensity of ultrasonic radiation. We have visualized the mixing state of the mixing chamber with radiation time and presented the influence of the driving voltage in this research. It will be possible to compare the performances of the ultrasonic radiation parts used in the active ${\mu}$-mixer using this method.

Synthesis and In Vitro Cytotoxicity of 1,3-Dioxoindan-2-Carboxylic Acid Arylamides

  • Jung, Jae-Kyung;Ryu, Jin-Hyeong;Yang, Sung-Il;Cho, Jung-Sook;Lee , Hee-Soon
    • Archives of Pharmacal Research
    • /
    • v.27 no.10
    • /
    • pp.997-1000
    • /
    • 2004
  • A series of 1,3-dioxoindan-2-carboxylic acid arylamides were synthesized and evaluated for in vitro cytotoxicity against four human cancer cell lines (HOP62, SK-OV-3, MD-MB-468 and T- 47D). The most active was compound 3e (1.2 ${\mu}M$ against SK-OV-3 cell line) bearing a 4- methyl substituent.

Fabrication of Micro-reactor by 3D Printing Machine (3D 프린터를 이용한 마이크로 리액터 가공에 관한 연구)

  • Choi, Hae Woon;Yoon, Sung Chul;Ma, Jae Kwon;Bang, Dae Wook
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.218-222
    • /
    • 2014
  • A 3D printer was used to fabricate a micro-TAS system for biomedical applications. A polymeric medical device fabrication based on a 3D printer can be performed at atmospheric conditions. A CAD- and CAM-based system is a flexible method to design medical components, and a 3D printer is a suitable device to perform this task. In this research, a 100-micron-wide fluidic channel was fabricated with a high-aspect ratio. A cross-sectional SEM image confirmed its possible usage in a micro-reactor using 3D printers. CNC-machined samples were compared to 3D printer-fabricated samples, and the advantages and disadvantages were discussed. Based on the SEM images, the surface roughness of the 3D printed reactor was not affected by wet or dry conditions due to its manufacturing principle. An aspect ratio of 5 to 1 was achievable with 100-${\mu}$ m-wide fluid channels. No melting was found, and the shape of channels was straight enough to be used for micro reactors.

Characteristic Analysis of Electrowetting on Dielectric Layer (절연층에 따른 액적의 전기습윤 특성 분석)

  • Choi, Jin Ho;Kim, Gyu man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.8
    • /
    • pp.38-43
    • /
    • 2019
  • Electrowetting on dielectric (EWOD) is a unique method of shape control of small-volume droplets in microfluidic biochips that relies on modification of surface wetting characteristics using electrical methods. In this study, the droplet shape control on various dielectric surfaces by the EWOD and the effect of droplets on the contact angle as well as the shape were investigated. The droplet used in the experiment was on a sample substrate with $5{\mu}l$ of de-ionized water (DIW) using a micropipette, and wettability was measured with a contact angle meter. This study is expected to be helpful for the development of various micro-total-analysis-systems (${\mu}TAS$) and microfluidic systems with MEMS technology.

Fabrication of the Optical Fiber-Photodiode Array Module Using Si v-groove (실리콘 v-groove를 이용한 광섬유-광검출기 어레이 모듈 제작)

  • 정종민;지윤규;박찬용;유지범;박경현;김홍만
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.88-97
    • /
    • 1994
  • We describe the design, fabrication, and performance of the optical fiber-photodiode 1$\times$12 arry module using mesa-type InS10.53T GaS10.47TAS/INP 1$\times$12 PIN photodiode array. We fabricated the PIN PD array for high-speed optical fiber parallel data link optimizing quantum efficiency, operating speed sensitivity from the PIN-FET structure, and electrical AC crosstalk. For each element of the array, the diameter of the photodetective area is 80 $\mu$m, the diameter of the p-metal pad is 90 $\mu$m, and the photodiode seperation is 250 $\mu$m to use Si v-groove. Ground conductor line is placed around diodes and p-metal pads are formed in zigzag to reduce Ac capacitance coupling between array elements. The dark current (IS1dT) is I nA and the capacitance(CS1pDT) is 0.9 pF at -5 V. No signifcant variations of IS1dT and CPD from element to element in the array were observed. We calulated the coupling efficiency for 10/125 SMF and 50/125 GI MMF, and measured the responsivity of the PD array at the wavelength is 1.55 $\mu$ m. Responsivities are 0.93 A/W for SMF and 0.96 A/W for MMF. The optical fiber-PD array module is useful in numerous high speed digital and analog photonic system applications.

  • PDF

Fabrications and Characteristics of Microfluidic Systems Actuated by Thermopneumatic Method (열공압 방식으로 구동되는 매세 유체 제어 시스템의 제작 및 특성)

  • Yoo Jong-Chul;Kang C. J.;Kim Yong-Sang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.2
    • /
    • pp.88-92
    • /
    • 2006
  • We present a microfluidic system with microvalves and a micropump that are easily integrated on the same substrate using the same fabrication process. The fabricated microfluidic system is suitable for use as a disposable device and its characteristics are optimized for use as a micro chemical analysis system (micro-TAS) and lab-on-a-chip. The system is realized by means of a polydimethylsiloxane (PDMS)-glass chip and an indium tin oxide (ITO) heater. We demonstrate the integration of the micropump and microvalves using a new thermopneumatic-actuated PDMS-based microfluidic system. A maximum pumping rate of about 730 nl/min is observed at. a duty ratio of 1 $\%$ and a frequency of 2 Hz with a fixed power of 500 mW. The measured power at flow cut-off is 500 mW for the microvalve whose channel width, depth and membrane thickness were 400 $\mu$m, 110 $\mu$m, and 320 $\mu$m, respectively.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

Nutrient Intake, the Concentrations of Leptin, Adiponectin, Cotisol & Insulin by the Body Fat Content of Women (성인여성의 체지방률에 따른 영양소섭취, 렙틴, 아디포넥틴, 코티졸 및 인슐린농도)

  • Lee, Soon Yei;Bae, Hyun Sook
    • Korean Journal of Community Nutrition
    • /
    • v.17 no.6
    • /
    • pp.714-723
    • /
    • 2012
  • The aim of this study was to compare nutrient intakes, serum hormones (leptin, adiponectin, insulin), salivary cortisol and ${\alpha}$-amylase of middle-aged women by the percentage of body fat (% fat). Subjects were assigned to 3 groups by body fat (%) group I (27.5%), group II (32.5%), group III (37.7%). WHR of group II (0.97) was significantly higher than of group I, III (0.95) (p < 0.05). Nutrient intakes were not different among 3 groups. Serum leptin levels of group III ($16.53{\mu}g/ml$) were higher than in group I ($10.07{\mu}g/ml$), group II ($12.24{\mu}g/ml$) (p < 0.05). Salivary cortisol levels of group II ($0.39{\mu}g/dl$) were higher than in group I ($0.17{\mu}g/dl$) and group III ($0.15{\mu}g/dl$) (p < 0.05). Adiponectin concentrations were negatively correlated with TAS (r = -0.29) and positively correlated with HDL cholesterol (r = 0.27). Insulin levels were negatively correlated with total cholesterol (r = -0.33), Zn intake (r = -0.31) and positively correlated with WHR (r = 0.31). The overall anthropometric indices showed positive relations with leptin levels. Salivary cortisol levels were positively corelated with WHR (r = 0.28), total cholesterol (r = 0.31), MDA (r = 0.29) and intakes of SFA (r = 0.35) and MUFA (r = 0.3). Salivary amylase levels were positively correlated with overall nutrient intakes (energy, CHO, fat, cholesterol. Fe, SFA, MUFA, Zn, Na, vitamin $B_2$, r = 0.24-0.5) and was negatively correlated with HDL cholesterol (r = -0.34). These results suggested that 1) WHR would be a helpful index in the assessment of metabolic risk diseases. 2) Understanding of individual stress exposure should be considered in developing strategies for prevention and treatment of obesity.

Performance Improvement of Peristaltic Micropump Using Various Actuating Signal (다양한 동작신호의 사용에 따른 연동형 마이크로 펌프의 성능 향상)

  • Hong, Pyo-Hwan;Jung, Dong-Geon;Pyo, Dae-Seong;Lee, Jong-Hyun;Cho, Chan-Seob;Kim, Bonghwan
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.428-432
    • /
    • 2013
  • This paper described the development of electrostatically driven peristaltic micropump. The proposed micropump consists of a flexible membrane and a single chamber which electrodes are inserted. The single chamber is divided into smaller cells by the electrodes. The fabricated micropump was operated with four electrodes in the membrane and a various phase sequencing actuation. We studied the changes in the flow rate corresponding to the actuating signal applied to the micropump under the zero hydraulic pressure difference between lnlet port and outlet port. The pump was operated from 60 to 130 V. Whereas the maximum flow rate in basic actuating signal is about 83 ${\mu}1/min$ at 15 Hz, the maximum flow rate in optimized actuating signal is about 114 ${\mu}l/min$ at 10 Hz.