• Title/Summary/Keyword: $\Delta$f

Search Result 828, Processing Time 0.029 seconds

Nasal Continuous Airway Pressure Titration Unmasks Periodic Limb Movements in Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증에서 지속적 상기도 양압술에 따른 주기성 사지운동증의 표출)

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.5 no.1
    • /
    • pp.103-110
    • /
    • 1998
  • Objectives : High co-morbidity of periodic limb movements during sleep(PLMS) and obstructive sleep apnea syndrome(OSAS) is well known and their incidences tend to increase in the elderly. Previous studies have inconsistently rep0l1ed increase or no change of periodic limb movement index(PLMI) by nasal continuous positive airway pressure(CPAP) in OSAS without analyzing possible variables affecting PLMI. We attempted to examine PLMI change evoked during CPAP titration and also factors affecting it in OSAS. Methods : Twenty-nine OSAS patients(M:F=26:3, mean age: $51.6{\pm}10.6\;yrs$) without other sleep disorders except for PLMS were selected, based on the nocturnal (baseline) polysomnograhy. Another night of noctumal polysomnography was performed for CPAP pressure titration. We compared between those two nights PLMI, mean and lowest $SaO_2$, and sleep variables. We also calculated PLMI differences between baseline and CPAP nights, named as delta PLMI (value of CPAP night PLMI minus value of baseline night PLMI). Correlations were calculated between delta PLMI and factors such as age, body mass index, applied CPAP pressure, baseline night values of respiratory disturbance index, mean and lowest $SaO_2$, and sleep parameter differences between baseline and CPAP nights. Results : Decrease of RDI(p<.01) and increase in mean and lowest $SaO_2$ (p<.05, p<.01) were observed during CPAP night. No sleep parameters showed significant change except for the decrease of total stage 1 sleep%(p<.01) during CPAP night. Ten out of 29 patients showed PLMI increase, while the other 19 patients showed either no change(n=14) or even PLMI decrease(n=5) during CPAP night. The 10 patients showing PLMI increase during CPAP night showed a significant positive correlation between delta PLMI and baseline night RDI(p<.05), which meant that PLMI increase was found to be more prominent in higher RDI patients than in lower RDI ones. There were no significant correlations between delta PLMI and other factors in the other 19 patients. Conclusions : We suggest that during the baseline night PLMS would have been underscored and/or masked due to the overlapping of PLMS and apneas/hypopneas or the arousals induced by apneas/hypopneas. Despite its still unknown mechanism, the CPAP application may unmask PLMS and increase PLMI in a subgroup of OSAS patients. It needs to be evaluated further whether the chronic CPAP use sustains the above finding.

  • PDF

TEC VARIATIONS OVER KOREAN PENINSULA DURING MAGNETIC STORM (남쪽방향 행성간 자기장에 의해 발생한 자기 폭풍 동안 한반도 상공의 총 전자수 함유량 변화)

  • Ji, E.Y.;Choi, B.K.;Kim, K.H.;Lee, D.H.;Cho, J.H.;Chung, J.K.;Park, J.U.
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.1
    • /
    • pp.33-42
    • /
    • 2008
  • By analyzing the observations from a number of ground- and space-based instruments, including ionosonde, magnetometers, and ACE interplanetary data, we examine the response of the ionospheric TEC over Korea during 2003 magnetic storms. We found that the variation of vertical TEC is correlated with the southward turning of the interplanetary magnetic field $B_z$. It is suggested that the electric fields produced by the dynamo process in the high-latitude region and the prompt penetration in the low- latitude region are responsible for TEC increases. During the June 16 event, dayside TEC values increase more than 15%. And the ionospheric F2-layer peak height (hmF2) was ${\sim}300km$ higher and the vertical $E{\times}B$ drift (estimated from ground-based magnetometer equatorial electrojet delta H) showed downward drift, which may be due to the ionospheric disturbance dynamo electric field produced by the large amount of energy dissipation into high-latitude regions. In contrast, during November 20 event, the nightside TEC increases may be due to the prompt penetration westward electric field. The ionospheric F2-layer peak height was below 200km and the vertical $E{\times}B$ drift showed downward drift. Also, a strong correlation is observed between enhanced vertical TEC and enhaaced interplanetary electric field. It is shown that, even though TEC increases are caused by the different processes, the electric field disturbances in the ionosphere play an important role in the variation of TEC over Korea.

A Study on Effects of Axial Gas Flow in the Gap and Fuel Cracking on Fission Gas Release under Power Ramping (출력 감발 조건하에서 핵분열 기체 생성물의 방출에 대한 축방향 기체 유동과 핵연료 파손의 영향에 관한 연구)

  • Han, Jin-Kyu;Yoon, Young-Ku
    • Nuclear Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.116-127
    • /
    • 1990
  • The fission gas release model used In the SPEAR-BETA fuel performance code was modified by use of effective thermal conductivity for cracked fuel and by laking Into account axial fission-gas mixing between the fuel-clad gap and the plenum. With use of this modified model the fission gas release was analyzed under various power ramping conditions of P$_{max}$ and $\Delta$.fP. Effective fuel thermal conductivity that accounts for the effect of fuel tracking was used in calculation of the fuel temperature distribution and the Internal gas pressure under power ramping conditions. Mixing and dilution effects due to axial gas flow were also considered in computing the width and the thermal conductivity of the gap. The effect of axial gas flow w3s solved by the Crank-Nicholson method. The finite difference method was used to save running time in the calculation. The present modified fission-gas release model was validated by comparing its predicted results with experimental data from various lamping tests In the literature and calculated results with use of the models used In the SPEAR-BETA and FEMAXI-IV codes. Results obtained with use of the present modified model showed better agreement with experimental data reported in the literature than those results with use of the latter codes. The fuel centerline temperature calculated with introduction of effective thermal conductivity for centerline temperature calculated with Introduction of effective thermal conductivity for cracked fuel was 200 higher fission gas release predicted with use of the modified model was nearly 6% larger on the average than that calculated by use of the unmodified model used in the SPEAR-BETA code.e SPEAR-BETA code.e.

  • PDF

Evaluation of periopathogenic bacteria of peri-implantitis using real-time PCR in Koreans: pilot study (한국인의 임플란트 주위 질환에서 real time PCR법을 이용한 치주세균 평가: pilot study)

  • Lee, Mun-Young;Kwon, Eun-Young;Kim, Hyun-Joo;Lee, Ju-Youn;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.186-195
    • /
    • 2018
  • Purpose: We performed quantitative and qualitative analysis of typical periodontal bacteria using real time PCR method to investigate the microbiological difference according to the severity of peri-implant disease in Koreans. Materials and Methods: Total of 60 implants were divided into three groups (healthy group, peri-implant mucositis group, peri-implantitis group) through periapical radiographs and clinical indices. The evaluated clinical parameters were pocket depth, plaque index, suppuration and bleeding on probing. Using a sterilized curette instrument, microbial samples were collected from the subgingival plaque and real-time PCR was performed on five periodontal bacteria. The relative expression levels of microorganisms were compared by comparative delta-CT method. Results: The relative expression levels of E. corrodens and T. denticola were significantly higher in the peri-implantitis group (P < 0.017). On the other hand, the relative expression level of F. nucleatum and P. gingivalis was relatively high in the healthy implant group regardless of the severity of disease. P. intermedia was significantly lower in the healthy implant group (P < 0.017). Conclusion: Periodontal bacteria were detected in Koreans with peri-implant diseases, but there was no microbiological distribution similar to periodontitis.

A Study on Properties of a Near-Field Microwave Microscope Using a Waveguide Resonator (도파관 공진기를 이용한 마이크로파 근접장 현미경의 특성에 관한 연구)

  • Kim, Hyun;Kim, Song-Hui;Kim, Joo-Young;Lee, Kie-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.16-24
    • /
    • 2008
  • Near-field scanning microwave microscope (NSMM) has been used to characterize the electromagnetic properties of samples based on a cavity perturbation technique. We used a NSMM using a waveguide cavity to couple a metallic probe tip as a point like evanescent field emitter. We explained the quality of our NSMM system by applying the cavity perturbation theory. First, to make a shape perturbation, we inserted linear and loop probes in the waveguide resonator. To check up electric and magnetic field distribution inside the waveguide resonator by shape perturbation, we confirmed the field distribution by using a HFSS simulation. Second, to make material perturbation, we located a dielectric sample in front of the probe tip and measured reflection coefficient $(S_{11})$. We found that the resonance frequency$(f_r)$ was changed linearly as the dielectric constant of resonator$({\varepsilon}_r)$ increased when ${\Delta}{\varepsilon}\;and\;{\Delta}{\mu}$ were small.

Use of δ-Aminolevulinic Acid in Swine Diet: Effect on Growth Performance, Behavioral Characteristics and Hematological/Immune Status in Nursery Pigs

  • Mateo, R.D.;Morrow, J.L.;Dailey, J.W.;Ji, F.;Kim, Sung Woo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.1
    • /
    • pp.97-101
    • /
    • 2006
  • Certain amino acids are essential precursors of a variety of important biomolecules in addition to their major function as protein building blocks. ${\delta}$-Aminolevulinic acid (ALA) is synthesized from the condensed form of succinyl-CoA with glycine after decarboxylation catalyzed by ALA synthase. The objective of the study was to determine the effects of ALA supplementation on growth performance, behavioral characteristics and hematological/immune status in nursery pigs. A total of 144 pigs weaned at 21 d of age were allotted to three dietary treatments representing (-) control (w/o antibiotics; NC), (+) control (w/carbadox at 50 mg/kg; PC), and the treatment group with ALA supplementation (0.05%; TA). Each treatment had 6 pens (replicates) with 8 pigs per pen. Pigs were fed phase 1 (21.9% CP, 1.40% Lys) and 2 (20.6% CP, 1.15% Lys) experimental diets for 3 and 2 wks, respectively. Feed intake and weight gain were measured weekly during phase 1 and at the end of phase 2. At the end of phase 2, blood samples were taken and analyzed using an automated hematology analyzer. Skin color and activity of pigs (48 h) from all pens in each treatment were measured at the second week of phase 2. Growth performance was not affected (p>0.05) by the dietary supplementation of ALA during the 5 wk nursery period. Pigs in the TA (6.46) and PC (6.68) had a higher (p<0.05) number of red blood cells ($10^6cell/{\mu}L$) than pigs in the NC (6.15). Pigs in PC (12.16) had a higher (p<0.05) hemoglobin level (g/dL) than pigs in the NC group (11.29) and the TA group (11.47). Pigs in the TA and PC had darker (p<0.05) and less (p<0.05) yellow skin color than pigs in the NC. Pigs in the PC tended (p = 0.081) to be less active than pigs in the other groups. There were no differences in behavioral characteristics between the NC and the TA. The data suggest that ALA supplementation has no adverse effects on growth performance of nursery pigs. Moreover, ALA supplementation increased red blood cell counts which may be beneficial to pigs.

Tooth whitening effect of toothpaste containing hydrogen peroxide (과산화수소가 배합된 제제의 치아미백효과에 관한 연구)

  • Ahn, Jae-Hyun;Kim, Ji-Hye;Kim, Jong-Hoon;Jang, Jong-Hwa;Oh, Yoon-Jong;Park, Yong-Duk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.1
    • /
    • pp.101-108
    • /
    • 2014
  • Objectives : The purpose of this study was to evaluate the tooth whitening effect of 0.74% and 2.80% hydrogen peroxide toothpastes and safety on tooth and gingival tissue. Methods : Toothpastes containing 0.74% and 2.80% hydrogen peroxide were evaluated. In in-vitro test, some additives (sodium metaphosphate, sodium pyrophosphate and titanium dioxide) were added to the toothpastes. Hydroxyapatite specimens (HAPs) were made and stained using modified Stookey's methods. HAPs were treated for 1 hour at shaking incubator and brushed for 1,000 times as 250 gF with each diluted toothpaste. Before and after color was measured by colorimeter. Using double blind method, 99 Korean with natural maxillary anterior teeth were selected and the initial brightness (baseline) was measured by SHADEEYE-EX. Based on this measurement they were crossly distributed into control group (0% hydrogen peroxide), test 1 (0.74% hydrogen peroxide) and test 2 (2.80% hydrogen peroxide). After 2 weeks, people of each group were provided toothpaste and told to use 3 times a day right after every meal for 3 minutes. The brightness of teeth was measured 3 times for every one month. Results : ${\Delta}L$ was statistically significant among three groups in shaking test. ${\Delta}L$ of two test groups was statistically significant compared with control group but not between each test group in brushing test. After using toothpaste for 3 months, test 1 group and test 2 group were 15.89% and 31.23% more whitened compared with control group respectively (p<0.05). Rate of more whitened person of each test group was 24.2% and 40.5% more than control group respectively (p<0.05). There was no difference in the hypersensitivity during 3 months using toothpastes and no side effect on teeth or gums. Conclusions : Toothpastes containing 0.74% and 2.80% hydrogen peroxide showed tooth whitening effect and both were safe enough to use for tooth whitening.

Separation and Elution Behavior of Some Iron(Ⅲ)porphyrin Complexes by Reversed-Phase Liquid Chromatography (역상 액체 크로마토그래피에 의한 Iron(Ⅲ)porphyrin 착화합물들의 분리 및 용리거동에 관한 연구)

  • Chang Hee Kang;In Whan Kim;Won Lee
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.12
    • /
    • pp.1035-1046
    • /
    • 1993
  • Some iron(III)porphyrin complexes were prepared, and identified by the spectroscopic methods. Elution behavior of iron(III)porphyrin complexes was investigated by reversed-phase HPLC. The optimum conditions for the separation of iron(III)porphyrin complexes were examined with respect to flow rate and mobile phase strength. These complexes were successfully separated on NOVA-PAK $C_{18}$ column using methanol / water(95/5) for $[T_pCF_3PP)Fe(R)]$ and methanol / water (98/2) for $[(P)Fe(C_6F_5)]$ as a mobile phase. It was found that these complexes were largely eluted in an acceptable range of capacity factor value ($0{\leq}logk'{\leq}1$). The dependence of the capacity factor (k') on the volume fraction of water in the binary mobile phase as well as the dependence of k' on the liquid-liquid extraction distribution ratio$(D_c)$ in methanol-water / n-pentadecane extraction system showed a good linearity. It means that the retention of iron(III)porphyrin complexes on NOVA-PAK $C_{18}$ column is largely due to the solvophobic effect. Also, there was a good linear dependence of the capacity factor(k') on the column temperature and enthalpy calculated by van't Hoff plot. From these results, it was confirmed that the retention mechanism of iron(III)porphyrin complexes in reversed-phase liquid chromatography was invariant under the condition of various temperature, and the solvophobic binding process exhibited isoequilibrium behavior.

  • PDF

The Study on the Additives and Magnetic Property of YIG Ferrites for Circulator/Isolator (서큘레이터/아이솔레이터용 YIG 페라이트의 첨가제와 자기적 특성 연구)

  • 윤휘영;유승규;이수형;윤종남;김정식
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.12
    • /
    • pp.1155-1161
    • /
    • 2001
  • Yittrium Iron Garnet(YIG) has been used as an important material in the circulator/isolator which is used in RF communication system, mobile phone, adn satellite broadcasting, etc. In this study, we investigated the microstructural and magnetic properties of YIG ferrites with the sintering temperature and additives. We fabricated the YIG ferrites substituted with Ca, In, V by the traditional ceramic sintering method at 1250$\^{C}$, 1275$\^{C}$, 1300$\^{C}$ and 1325$\^{C}$. Powders were granulated by using a spray dryer. Crystallographic and microstructural properties were measured by using XRD and SEM. Magnetic properties were measured by using a VSM for saturation magnetization (4$\pi$M$\_$s/) and FMR (Ferromagnetic Resonance) experiment for ferromagnetic resonance line width (△H). The YIG ferrite, Y$\_$1.6/Ca$\_$1.4/Fe$_4$V$\_$0.7/In$\_$0.3/O$\_$12/, sintered at 1300$\^{C}$, showed higher saturation magnetization and lower ferromagnetic resonance line width than any other sintering temperatures.

  • PDF

Mössbauer Studies of CoGa0.1Fe1.9O4 Nanoparticles (나노분말 CoGa0.1Fe1.9O4의 Mössbauer 분광학적 연구)

  • Lee, Seung-Wha
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.2
    • /
    • pp.144-148
    • /
    • 2006
  • $CoGa_{0.1}Fe_{1.9}O_4$ nanoparticles have been prepared by a sol-gel method. The structural and magnetic properties have been investigated by XRD, SEM, VSM and $M\ddot{o}ssbauer$ spectroscopy. $CoGa_{0.1}Fe_{1.9}O_4$ powder that was annealed at $250^{\circ}C$ has spinel structure and behaved superparamagnetically. The estimated size of superparammagnetic $CoGa_{0.1}Fe_{1.9}O_4$ nanoparticle is around 10 nm. The hyperfine fields at 4.2 K f3r the A and B patterns were found to be 518 and 486 kOe, respectively. The blocking temperature $(T_B)$ of superparammagnetic $CoGa_{0.1}Fe_{1.9}O_4$ nanoparticle is about 250 K. The magnetic anisotropy constant of $CoGa_{0.1}Fe_{1.9}O_4$ nanoparticle was calculated to be $3.0X10^5\;ergs/cm^3$. $CoGa_{0.1}Fe_{1.9}O_4$ nanoparticle was annealed at $250^{\circ}C$ will be used to candidate for biomedicine applications as magnetic carriers.