DOI QR코드

DOI QR Code

Evaluation and improvement of external electric blinds through field application

실증 적용을 통한 외부 전동블라인드의 성능 평가 및 개선 방안

  • Received : 2023.04.17
  • Accepted : 2023.05.16
  • Published : 2023.05.31

Abstract

In a typical living space, windows are directly exposed to the external noise environment. The best way to reduce outside noise is to block it from the outside, not the inside. Exterior blinds for blocking sunlight are commercialized in various ways. However, it has not yet been actively utilized in Korea. In the previous study, an experiment was conducted in an accredited laboratory to verify the sound insulation performance of an external motorized blind manufactured for shading. And it was verified that there is a sound insulation performance of 6 dBA compared to the reduction performance of a general window. In this study, we tried to confirm the reduction performance by applying the sound insulation performance of external electric blinds to windows in actual living spaces. In addition, an improvement plan was sought to increase the effective noise reduction performance. As a result of the measurement, the reduction performance of the external motorized blind itself was insufficient at the level of 1 dBA to 3 dBA. However, additional reduction performance of the 2 dBA level was confirmed by filling the gap between the blind slits.

일반적인 거주 공간에서 창호는 외부소음에 직접적으로 노출된다. 외부소음을 가장 효과적으로 저감할 수 있는 방법은 내부가 아닌 외부에서 바로 소음을 차단하는 방법이다. 태양 빛 차단을 위한 외부 블라인드는 다양하게 제품화되어 있지만, 우리나라에서는 아직 적극적으로 활용되지 못하고 있다. 앞선 연구에서는 차광용으로 제작된 외부 전동블라인드의 차음성능을 검증하기 위해 공인 실험실에서 실험하였다. 그 결과 일반창호 저감 성능 대비 6 dBA의 추가 차음성능을 검증하였다. 이 연구에서는 외부 전동블라인드의 차음성능을 실제 거주 공간 창호에 실증 적용하여 저감성능을 확인하고자 하였으며, 효과적인 소음저감 성능 추가확보를 위해 개선방안을 모색하고자 하였다. 실험결과, 외부 전동블라인드 자체의 저감 성능은 기본 창호 대비 1 dBA ~ 3 dBA 수준으로 미미했다. 하지만 블라인드 슬릿 사이의 틈새 충진을 통해 2 dBA 수준의 추가 저감성능을 확인하였다.

Keywords

Acknowledgement

이 연구는 한국연구재단의 정부지원(과학기술정보통신부)으로 진행 되었습니다. NRF-2020R1A2C1015162. 이 논문은 2023년도 정부(교육부)의 재원으로 한국연구재단의 지원을 받아 수행된 기초연구사업임(NRF-2022R1I1A1A01072221).

References

  1. H. J. Lee, K. S. Kwak, and J. S. Kim, "A study on the sound propagation through window in traffic noise regulation areas" (in Korean), J. Korean Soc. Environ. Eng. 26, 21-27 (2004).
  2. C. G. Cho and S. K. Yum, "Comparison of measuring and rating methods of airborne sound insulation of facade window in apartment building" (in Korean), J. KIAEBS, 4, 54-60 (2010).
  3. M. K. Joo, "Investigation of the sound insulation performance of balcony window through field measurement" (in Korean), J. Korea Inst. Ecol. Archit. And Environ. 9, 63-68 (2009).
  4. J. K. Oh, H. K. Kim, and M. J. Kim,"Development and evaluation for improvement of the sound insulation of balcony window in apartment" (in Korean), Proc. Trans. Korean Soc. Noise Vib. Eng. 445-450 (2004).
  5. M. W. Kang, H. D. Lee, and Y. K. Oh. "Improvement of sound insulation performance of windows according to the specifications of the external electric blinds" (in Korean), J. Acoust. Soc. Kr. 41, 621-628 (2022).
  6. KS F 2235, Field Measurements of Sound Insulation of Building Facades and Facade Elements, 2021.
  7. KS F 2862, Rating of Airborne Sound Insulation in Buildings and of Building Elements, 2022.