• Title/Summary/Keyword: 실증실험

Search Result 849, Processing Time 0.038 seconds

Performance Analysis of Hybrid Desiccant Chiller Based on Field Test (실증 실험을 통한 하이브리드 제습냉방 시스템의 성능 분석)

  • Ahn, Joon;Yun, Changho;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.621-627
    • /
    • 2013
  • Field tests of hybrid desiccant cooling systems were conducted from July to August 2011. Data were monitored and transferred in real time over the Internet. The monitored variableswere analyzed to determine the performance characteristics under outdoor conditions. A series of system simulations has been conducted for outdoor conditions of the field tests. The results agree well with the experimental data in general. The system performance has been shown to deteriorate for wetter conditions, as predicted by the simulation.

KMRR의 열수력학적 설계를 위한 실증실험

  • 임인철;김헌일;이보욱;이지복
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.343-352
    • /
    • 1993
  • 다목적연구로(KMRR)는 일반 발전용 원자로와는 매우 다른 특성을 가지고 있으며, 설계 개념 또한 특이하다. 위와 같은 특이한 설계 특성을 파악하기 위하여 열수력 실험을 수행하였으며 시운전 시험도 설계 개념의 입증에 중점을 두고 수행될 예정이다. 실증실험은 크게 설계 자료 생산을 위한 실험, 기기 설계 검증 시험, 시운전 성능 시험으로 나눌 수 있다. 설계 자료 생산을 위한 실험으로 핵연료의 열수력학적 특성을 규명하는 실험, 우회 유동에 의한 노심 출구 냉각수 상승 억제를 입증 또는 해석하기 위한 자료 생산용 실험 등이 이루어졌다. 기기 설계 검증 시험으로는 Pump 특성 시험, Flap valve 특성 시험 등을 들 수 있다. 또한, 시운전 성능 시험으로는 설계 개념을 입증하기 위한 여러 시험들이 행해질 예정이다. 이러한 실험들을 통하여 설계에 필요한 많은 자료들이 생산되었고, 시운전 시험을 통하여 설계를 검증하고 실제 운전에 필요한 많은 자료를 얻을 수 있으리라 기대된다. 본 기고를 통하여 이러한 실험의 중요성 및 내용에 대해 간략하게 기술하고자 한다.

  • PDF

Experiment of Discharge Supply Verification in River Experiment Center (하천실증연구센터 공급 유량 검증 실험)

  • Kim, Jong Min;Lee, Du Han;Kim, Sung Joong;Kim, Hyung Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.77-77
    • /
    • 2018
  • 한국 건설기술연구원의 하천실증연구센터는 기존에 불가능했던 준 실규모 하천실험, 생태실험, 치수분야 대형 모형실험 및 하천관련 기준수립을 위한 치수분야 수요와 하천 구조물의 품질성능평가 등을 목적으로 설립된 대규모 하천실증연구센터이다. 안동 하천실증연구센터는 총면적 $193,051m^2$의 부지에 하천의 일반적인 형상을 갖고 있는 완경사, 급경사, 만곡수로가 있으며, 수리량 측정 실험을 위한 초음파 유속계, 프로펠러 유속계, 전자식 유속계 등의 유속 측정 장비를 보유하고 있고, Total Station, Lidar, RTK-GPS 등 지형 측량에 사용할 수 있는 장비들도 보유하고 있어, 하천관련 실험을 수행하기에 충분한 여건을 보유하고 있다. 하천실증연구센터는 2013년부터 내 외부활용에서 활용할 수 있도록 지원을 수행하였으며, 총 118건의 하천 수리 및 생태분야, 지반분야 등 다양한 토목분야의 연구자들이 하천실증연구센터를 방문하여 실험을 수행하였고, 국내 기관 및 대학뿐만 아니라 미국의 Iowa 대학, Idaho 대학, USGS, 네덜란드 Deltares, 프랑스 Irstea 등 외국의 대학 및 기관에서도 방문하여 실험 및 공동연구를 수행하였다. 안동 하천실증연구센터의 활용 범위와 활용 건수가 지속적으로 증가함에 따라 자체적인 검토 및 외부의 의견에 따라 센터의 실험시설에 대한 개선이 필요한 사항이 발생하게 되었다. 하천실증연구센터의 수로는 기존의 지반위에 성토를 하여 인공적으로 건설하였기 때문에 일반적인 실내의 실험수로와는 다르게 하상에서의 침투가 발생하며, 이에 따라 하류방향으로 흐름이 진행될수록 유량의 변동이 발생하게 된다. 이에 따라 침투로 인해 발생하는 유량의 변동이 하도 유량 공급의 안정화에 미치는 영향에 대한 신뢰성 검증의 필요성이 필요하다고 판단되어 펌프에서의 유량 공급 및 하도내에서의 유량 안정화에 대한 검증 실험을 수행하고자 한다. 유량 공급에 대한 검증 실험은 크게 두 단계로 구성하였다. 첫 번째 단계는 펌프의 유량 공급에 대한 검증실험을 수행하고, 두 번째 단계에서는 동일한 조건내에서 하류의 지하수 수심, 공급수조의 수심, 하도내의 수심과 ADV 및 ADCP로 측정된 유량과의 관계를 통해 하도내의 유량이 얼마나 일정하게 공급되고, 하류방향으로 갈수록 유량 손실의 경향에 대한 실험을 계획하였으며, 전체적인 실험은 장기적으로 각 수로에 대하여 수행하는 것을 목표로 하였으며, 본 실험단계에서는 완경사 수로를 대상으로 하였다.

  • PDF

Analysis of Case Studies on Experimental Research of Gas Generation in Foreign Countries for Low- and Intermediate-level Radioactive Waste Disposal (중.저준위 방사성폐기물 처분을 위한 국외 기체발생 실증실험시설 운영사례 분석)

  • Park, Jin-Beak;Lee, Sun-Joung;Kim, Suk-Hoon;Kim, Ju-Youl
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.229-238
    • /
    • 2010
  • In order to acquire a realistic forecast for the lifetime and post-closure period of the LILW (Low- and Intermediate-Level Radioactive Waste) repository and to establish the overall management plan associated gas issues. it is essential to carry out the long-term experimental research in a similar condition to actual disposal environment. Regarding this, as a part of the following-up actions on a construction and operation license for the first stage of the LILW repository at Gyeongju city, a large-scale in-situ experiment is being planned. For securing basic data on the experiment, the experimental researches related to gas generation previously performed in foreign countries are reviewed in detail. Consequently, it is judged that data on the gas generation experiment in Finland could be practically applied as the benchmark for our large-scale in-situ experiment because the same disposal concept as the Korean repository is adopted and the experiment is performed in a scale large enough to allow the use of regular waste packages.

Empirical experiment to improve the applicability of the formula for time of concentration (홍수도달시간 산정식 적용성 개선을 위한 실증실험)

  • Keum, Ho Jun;Ko, Taekjo;Joo, Jaeseung;Kim, Yerim;Jung, Dojoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.123-123
    • /
    • 2021
  • 도시하천유역이나 복합유역 등 지역적 성향을 고려한 도달시간 산정에 관한 연구는 현재까지도 미흡한 실정이다. 소규모 유역의 홍수량을 산정할 경우 유하시간보다 유입시간 비중이 상대적으로 크다. 그러나 유하시간만을 고려하여 도달시간을 산정할 때, 소규모 유역의 경우 하도가 없고 유역면적이 5km2 내외 또는 하도의 저류 효과를 기대할 수 없는 경우 도달시간이 짧아 홍수량이 과대 산정된다. 이를 극복하고자 재해영향성평가등의 협의 실무지침에서는 도달시간 이외에 매개변수인 저류상수를 인위적으로 증가시키는 방법을 제안하고 있다. 하지만 이 방법 역시 유역의 물리적인 특성을 나타내는 변수를 왜곡한다는 근복적인 문제를 완전히 해결하지 못하였다. 이에 본 연구에서는 기존 중·대규모 하천을 대상으로 수행된 연구결과를 바탕으로 제안된 홍수 도달시간 산정방법의 한계를 극복하고, 유입시간이 지배적인 소규모 복합유역에 적용 가능한 도달시간 산정방안을 제시하고자 한다. 이를 위해 실증실험을 통해 기존 유입시간 산정식을 개선하고, 도시수문 모니터링 시범유역에 적용하여 정확성을 평가하고자 하였다. 먼저, 홍수도달 시간 측정을 위한 강우유출 실내 실험장치를 제작하였다. 실험장치는 본체(길이3m×폭1.2m×높이0.8m)와 경사조절 장치(0~15도)를 포함하고 있다. 본체 전면부를 타공(ø10mm)하고 상·하단에서 지표와 기저유출을 집수하여 티핑버킷으로 유량을 측정하였고, 토체 내에는 토양수분센서를 설치하여 강우유출 발생시간 동안 토양수분 변화를 측정하였다. 본 연구에서는 하도흐름인 유하시간(Kraven 공식)을 계산하여 도달시간을 산정하기 보다 지표면 흐름인 유입시간(Kerby 공식)에 보정계수를 도입하여 도달시간을 산정하는 방안을 검토하였다. 실험 결과, 불투수 면적비율이 증가함에 따라 도달시간은 감소하고, 불투수 유역이 하류에 위치할수록 유출발생시간이 빨라졌다. 실증실험 결과를 바탕으로 도시수문 모니터링 시범유역에 적용하여 기존 유하시간과 저류상수를 보정하는 도달시간 산정방식(연속형 Kraven)과 유입시간을 보정한 도달시간 산정(수정 Kerby)으로 도출된 유출량을 실측 유량과 비교하였다. 그 결과 제안된 홍수도달시간 산정식에서 모의된 홍수량이 기존 방식과 유사하거나 우수한 첨두홍수량을 보였으며, 설계자 임의성이 배제된 일관성있는 해석값을 제시해 줄 것으로 판단된다.

  • PDF

Thermal-Hydro-Mechanical Behaviors in the Engineered Barrier of a HLW Repository: Engineering-scale Validation Test (고준위폐기물처분장 공학적방벽의 열-수리-역학적 거동 연구: 엔지니어링 규모의 실증실험)

  • Lee, Jae-Owan;Cho, Won-Jin
    • Tunnel and Underground Space
    • /
    • v.17 no.6
    • /
    • pp.464-474
    • /
    • 2007
  • An enhancement in the performance and safety of a high-level waste repository requires a validation of its engineered barrier. An engineering-scale test (named "KENTEX") has been conducted to investigate the thermal-hydro-mechanical behaviors in the engineered barrier of the Korean reference disposal system The validation test started on May 31, 2005 and is still under operation. The experimental data obtained allowed a preliminary and qualitative interpretation of the thermal-hydro-mechanical behaviors in the bentonite blocks. The temperature was higher as it became closer to the heater, while it became lower as it was farther away from the heater. The water content had a higher value in the part close to the hydration surface than that in the heater part. The relative humidity data suggested that a hydration of the bentonite blocks might occur by different drying-wetting processes, depending on their position. The total pressure was continuously increased by the evolution of the saturation front in the bentonite blocks and thereby the swelling pressure. Near the heater region, there was also a significant contribution of the thermal expansion of bentonite and the vapor pressure in the pores of the bentonite blocks.

Analysis of Electric Potential Distribution due to Condition of Grounding Environment (접지환경 조건에 따른 지중함의 전위분포 해석)

  • Kim, Chong-Min;Bang, Sun-Bae;Han, Woon-Ki;Kim, Han-Sang;Shim, Keon-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2074-2075
    • /
    • 2007
  • 본 연구에서는 침수된 저압 지중함에서 발생될 수 있는 누전 사고시 지중함내의 접지조건이 주변의 대지전위분포에 미치는 영향을 고찰하였다. 저압 지중함 실증실험장을 설계 구축하였으며 3가지 접지조건의 경우에 대해 대지전위 측정 실험을 실시하였다. case 1과 case2와 같은 실증실험을 통해 저압 지중함에 설치되어 있는 접지선은 저압 지중함에서 대지전위 분포에 거의 영향이 없음을 확인하였으며, case 3과 같은 실증실험을 통해 저압 지중함 철재틀에 접지단자를 본딩 할 경우 저압 지중함 주변의 대지전위 상승이 거의 발생되지 않음을 확인하였다. 따라서 저압 지중함 철재틀에 접지단자를 본딩 할 경우 혹시 발생될 수 있는 지중함의 누전에 의한 감전사고를 매우 효과적으로 방지할 수 있을 것이다.

  • PDF

Verification Experiment and Analysis for 6 kW Solar Water Heating System(Part 1: Verification Experiment) (6kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제1보 실증실험))

  • 김진홍;김성수;최봉수;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.128-134
    • /
    • 2004
  • In order to verify and take measures against a variety of troubles which cannot be predicted in a well-controlled laboratory, it is necessary that solar system should be experimented in an actual situation during a long period. Through this experiment it can be also understood how the load pattern and operational conditions expected in a design process become different to those in the actual running, which can be applied to a new system design. We installed 6 kW solar hot water heating system with a shower facility and operated during 7 months. As a result, average 8.3 persons took a shower a day; solar fraction is 71% and total collector efficiency is 40% during the periods from March to September. We confirmed several troubles encountered in the actual situation and considered practical center-measures.

Engineering-scale Validation Test for the T-H-M Behaviors of a HLW Disposal System (고준위폐기물 처분시스템의 열적-수리적-역학적 거동 규명을 위한 공학적 규모의 실증시험)

  • Lee Jae-Owan;Park Jeong-Hwa;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.197-207
    • /
    • 2006
  • The engineering performance of a high level waste repository is significantly dependent upon the T-H-M behavior in the engineered barrier system. An engineering-scale test facility (KENTEX) was set up to validate the T-H-M behaviors in the buffer of a reference disposal system developed in the 2002. The validation tests started on May 31, 2005 and is now in progress. The KENTEX facility and validation test programme are introduced, and pre-operation calculations are also presented to give information on the sensitive location of sensors and operational conditions. This test will provide information (e.g., large-scale apparatus, sensors, monitoring system etc.) needed for 'in-situ' tests, make the validation of a T-H-M model for the T-H-M performance assessment of the reference disposal system, and demonstrate the engineering feasibility of fabricating and emplacing the buffer of a repository.

  • PDF

Analysis of river flow characteristics for vegetation in real-scale experiment center (실규모 실험장에서의 식생에 따른 하천 흐름특성분석)

  • Kim, Jong Min;Kim, Hyung Suk;Lee, Chan Joo;Kim, Sung Joong;Kim, Dong gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.271-271
    • /
    • 2019
  • 하천에서의 식생은 하천의 조도 및 흐름특성을 변화시키는 요인 중 하나로서 하천 내의 식생밀도 변화로 인하여 발생한 하상변동은 장기적으로 하천내의 하중도가 발생하거나, 식생으로 인해한 방향으로 편중된 흐름으로 인하여 제내지 방향으로의 하천 침식이 발생하고, 이에 따라 구조물의 안정성에 영향을 미치는 등 하천의 중 장기 계획 시 고려해야할 중요한 요인이다. 이에 따라 식생 모형을 이용한 다양한 흐름특성 분석 실험들이 수행되었으나, 대부분의 연구에서는 식생을 단순화하여 모형으로 사용하였기 때문에 실제 식생에 대한 영향성을 보기에는 한계가 존재한다. 건설기술연구원의 하천실증연구센터에서는 이러한 식생의 영향을 분석하기 위하여 네덜란드의 Deltares, 핀란드의 Aalto 대학 등과 함께 다년간 국제공동연구를 수행하였으며, 금번 소개하는 실험에서는 식생밀도에 따른 흐름변화, 하상변동 및 환경 변화 등의 검토를 목적으로 하였다. 실험은 총 2가지 유량 조건에 대하여 수행되었으며, 실험 중 흐름의 안정화를 확인하기 위하여, 유출수조에는 6개의 압력식 수위계를 설치하여 실험기간동안 유출수조에서의 수심변화를 측정하였고, 하도에는 실험구간 상 하류에 SonTek의 SL-1500 및 SL-3000을 이용하여 지속적으로 수심을 측정하고, 이 외에도 하류단에 2개의 압력식 수위 측정장비를 설치하여 수심을 모니터링하였다. 실험에 사용된 식생은 높이 약 1.5m의 2가지 밀도로 폭 2m, 길이 4m의 규모로 설치하였고, 광파기와 3차원 레이저 스캐너를 이용하여 실험 전 후의 식생 주변 및 전 실험구간의 하상을 측량하였다. 흐름특성 분석을 위한 수리 측정은 Nortek사의 Vectrino를 이용하여 측정하였고, 총 24개 측선에 대하여 각 측선별 5 ~ 10개의 유속자료를 측정하였으며, 각 측점별로 90초간 자료를 수집하였다. 흐름특성 분석에 사용된 유속자료는 이상치를 제거한 후 수행되었으며, 이상치의 제거는 표준편차의 3배 이상의 편차를 갖거나, 측정자료의 자기상관도가 70% 이하인 값들은 제거한 후 분석을 수행하였다. 흐름 분석을 위한 측정자료를 이 외에도 캠코더를 이용한 표면유속영상 측정기법과 ADCP를 이용한 측정도 병행하였으나, 본 연구에서는 Vectrino로 측정된 결과만을 소개하고자 한다.

  • PDF