References
- J. F. Zhang, Y. M. Dong, C. J. Yang, Y. Geng, Y. Chen, and T. Yang, "5-Link model based gait trajrctory adaption control strategies of the gait rehabilitation exoskeleton for post-stroke patients", Mechatronics, Vol. 20, No. 3, pp. 368-376, 2010. https://doi.org/10.1016/j.mechatronics.2010.02.003
- N. Karavas, A. Ajoudani, N. Tsagarakis, J. Saglia, A. Bicchi, and D. Caldwell, "Tele-impedance based assistive control for a compliant knee exoskeleton", Robotics and Autonomous Systems, Vol. 73, pp. 78-90, 2015. https://doi.org/10.1016/j.robot.2014.09.027
- V. Rajasekaran, J. Aranda, A. Casals, and J. L. Pons, "An adaptive control strategy for postural stability using a wearable robot", Robotics and Autonomous Systems, Vol. 73, pp. 16-23, 2015. https://doi.org/10.1016/j.robot.2014.11.014
- A. Pennycott, K. J. Hunt, L. P. Jack, C. Perret, and T. H. Kakebeeke, "Estimation and volitional feedback control of active work rate during robot-assisted gait", Control Engineering Pracrice, No. 17, pp. 322-328, 2009.
- P. Malcolm, P. Fiers, V. Segers, I. Van Caekenberghe, M. Lenoir, and D. De Clercq, "Experimental study on the role of the ankle push off in the walk-to-run transition by means of a owered ankle-foot-exoskeleton", Gait & Posture, No. 30, pp. 322-327, 2009.
- M. Wu, T. G. Hornby, J. M. Landry, H. Roth, and B. D. Schmit, "A cable-driven locomotor training system for restoration of gait in human SCI", Gait & Posture, No. 33, pp. 256-260, 2011.
- M. M. Martins, C. P. Santos, F. N. Anselmo, and R. Ceres, "Assistive mobility devices focusing on Smart Walkers: Classification and review", Robotics and Autonomous Systems, No. 60, pp. 548-562, 2012.
- J. H. Jung, and G. S. Kim, "Design of Force Sensors of Rehabilitation Robot for Knee Rehabilitation", Journal of Institute of Control, Robotics and Systems (in Korean), Vol. 23, No. 1, pp. 46-52, 2017. https://doi.org/10.5302/J.ICROS.2017.16.0176
- H. S. Kim, and G. S. Kim, "Design of Two-axis Force/Torque Sensor for Hip Joint Rehabilitation Robot", Journal of Institute of Control, Robotics and Systems (in Korean), Vol. 22, No. 7, pp. 524-529, 2016. https://doi.org/10.5302/J.ICROS.2016.16.0067
- S. A. Liu, and H. L. Tzo, "A novel six-component force sensor of good measurement isotropy and sensitivities", Sensors and Actuators A, Vol. 100, pp. 223-230, 2002. https://doi.org/10.1016/S0924-4247(02)00135-8
- A. Song, J. Wu, G. Qin, and W. Huang, "A novel self-decoupled four degree-of-freedom wrist force/torque nsor", Measurement, Vol. 40, pp. 883-891, 2007. https://doi.org/10.1016/j.measurement.2006.11.018
- ATI Industrial Automation, "Multi-axis forcre/torque sensor," ATI Industrial Automation, pp. 4-45, 2014.
- G. S. Kim, and J. W. Yoon, "Development of calibration system for multi-axis force/moment sensor and its uncertainty evaluation", Korean Society Precision Engineering, Vol. 24, No. 10, pp. 91-98, 2007.