초록
A pair of connectors for transferring torque is widely used in various types of a mechanical system. By the repetition of mechanical contact between a pair of connector, wear occurs easily. This kind of defect sometimes can cause a serious problem of health in case of the connector is used in a refrigerator. In this work, the material combination of connectors was experimentally studied to reduce the amount of wear; for the combination of connectors, various types of engineering materials including polyacetal, polycabonate, stainless steel (STS-304), NiP coated STS-304, and STS-310 were evaluated to check each wear behavior. Also an effective method of wear test was suggested for precise controlling of wear conditions such as contact area, contact force, and relative motion speed. From the test results, it was found out that a pair of polyacetal to STS-304 and STS-310 showed the lowest specific wear rates among other pairs.