참고문헌
- Diller, T. E., "Advances in Heat Flux Measurements-In Advances in Heat Transfer, Vol. 23," Elsevier, pp. 279-368, 1993
- Eminoglu, S., Tezcan, D. S., Tanrikulu, M. Y. and Akin, T., "Low-cost uncooled infrared detectors in CMOS process," Sensors and Actuators A: Physical, Vol. 109, No. 1-2, pp. 102-113, 2003 https://doi.org/10.1016/j.sna.2003.08.013
- Matsumiya, M., Shin, W., Izu, N. and Murayama, N., "Nano-structured thin-film Pt catalyst for thermoelectric hydrogen gas sensor," Sensors and Actuators B: Chemical, Vol. 93, No. 13, pp. 309-315, 2003 https://doi.org/10.1016/S0925-4005(03)00223-5
- Buchner, R., Rohloff, K., Benecke, W. and Lang, W., "A high-temperature thermopile fabrication process for thermal flow sensors," Sensors and Actuators A: Physical, Vol. 130-131, pp. 262-266, 2006 https://doi.org/10.1016/j.sna.2006.02.009
- Oh, S. H., Jeon, J. C., Kim, M. H. and Lee, S. S., "The micro Heat flux sensor using electroplated copper layers," J. of the KSPE, Vol. 17, No. 7, pp. 226-231, 2000
- Kim, J. H., Kim, B. S., Cho, H. H. and Kim, Y. J., "Fabrication and evaluation of a micro heat flux sensor using thermopile," Proc. of the KSPE Spring Conference, pp. 1210-1213, 2005
- Han, E. K., Choi, G. C., Rho, B. O., Park, T. W. and Lee, M. H., "Development of heat flux sensor using adhesive type film gauge for measuring temperature," J. of the KSPE, Vol. 9, No. 2, pp. 52-60, 1992
- Zhang, Y. and Tadigadapa S., "Calorimetric biosensors with integrated microfluidic channels," Biosensors and Bioelectronics, Vol. 19, No. 12, pp. 1733-1743, 2004 https://doi.org/10.1016/j.bios.2004.01.009
- Baier, V., Fodisch, R., Ihring, A., Kessler, E., Lercher, J., Wolf, G., Kohler, J. M., Nietzsch, M. and Krugel, M., "Highly sensitive thermopile heat power sensor for micro-fluid calorimetry of biochemical processes," Sensors and Actuators A: Physical, Vol. 123-124, pp. 354-359, 2005 https://doi.org/10.1016/j.sna.2005.05.018
- Dehe, A., Fricke. K. and Hartnagel, H. L., "Infrared thermopile sensor based on AlGaAs-GaAs micromachining," Sensors and Actuators A: Physical, Vol. 47, No. 1, pp. 432-436, 1995 https://doi.org/10.1016/0924-4247(94)00936-C
- Johannessen, E. A., Weaver, J. M. R., Cobbold, P. H. and Cooper, J. M., "A Suspended Membrane Nanocalorimeter for Ultralow Volume Bioanalysis," IEEE Trans. on Nanobioscience, Vol. 1, No. 1, pp. 29-36, 2002 https://doi.org/10.1109/TNB.2002.806935
- Kemp, R. B. and Guan, Y., "Heat flux and the calorimetric-resirometric ratio as measures of catabolic flux in mammalian cells," Thermochimica Acta, Vol. 300, No. 1-2, pp. 199-211, 1997 https://doi.org/10.1016/S0040-6031(96)03125-5
- Kim, J. K., Kim, T. H., Cho, S. C., Shin, S. M. and Lee, S. K., "Modeling and fabrication of thin film thermopile sensor," J. of Va. Sci. Technol. B, Vol. 27, No. 3, pp. 1466-1472, 2009 https://doi.org/10.1116/1.3046152
- Granda, J. J, "The role of bond graph modeling and simulation in mechatronics systems:An integrated software tool: CAMP-G, MATLAB-SIMULINK," Mechatronics, Vol. 12, No. 9, pp. 1271-1295, 2002 https://doi.org/10.1016/S0957-4158(02)00029-6
- JEDEC, "EIA/JEDEC Standard No. 51-1, Integrated Circuits Thermal Measurement Method-Electrical Test Method (Single Semiconductor Devices)," JEDEC, pp. 3- 24, 1995