Abstract
Monochromatic X-ray can make a medical image of high contrast under a low radiation dose and can be easily generated by combining an X-ray tube and a multilayer mirror. A W/C multilayer mirror was optimally designed for a characteristic X-ray generated from a X-ray tube with Mo target. The d-spacing and the thickness ratio in design parameters were determined under the maximum-reflectivity condition. Tolerances for deposition and alignment of the W/C multilayer mirror were calculated. Within a deposition tolerance of 0.2nm and a alignment tolerance of
단색 엑스선은 적은 방사선 피폭으로 대조도가 높은 의료영상을 만들 수 있다. 엑스선 튜브와 다층박막 거울을 결합하면 높은 플루언스의 단색 엑스선을 얻을 수 있다. 몰리브덴(Mo) 타깃을 갖는 엑스선 튜브에서 Mo 특성방사선(17.5keV)을 높은 반사율로 획득하기 위한 W/C 다층박막 거울의 최적화를 수행하였다. 반사율이 최대가 되는 조건에서 두께주기와 두께비를 결정하였다. 최적 설계된 다층박막 거울에 대한 두께주기와 브래그 정렬에 대한 공차를 구하였다. 증착(deposition) 공차 0.2nm와 회전정렬 공차